Loading...
HomeMy WebLinkAboutProduct Approval 12/16/2019 Florida Building Code Online FWMDA WARM=Or Professional Regulation BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge + Stats&Facts I Publications I Contact Us I, BCIS Site Map'I Links I 'Search I a db R M Product Approval f r E - USER.Public User - --"` Product Aoyroyal Menu>Product or AQplication Search>Application List>Application Detail DECC 18 2019 ° FL# FL15279-R5 F Application Type Revision ST. Lucie County, Permitting Code Version 2017 Application Status Approved Comments reapply 11/28/1 A - 'OPY Archived r— I L 1= U Product Manufacturer Clopay Building Products Company Address/Phone/Email 8585 Duke Blvd. Mason,OH 45040. (513)770-6062 mwesterfield@clopay.com Authorized Signature Scott Hamilton shamilton@clopay.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Sectional Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency Intertek Testing Services NA,Inc. Validated By Gary Pfuehler i6 Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year ANSI/DASMA 108 2005 ANSI/DASMA 115 2005 ASTM E1886 2002 ASTM E1996 2002 ASTM E330 2002 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL15279 R5 Equiv 20170809-FBC-DASMA 108 eouiy.Ddf FL15279 R5 Equiv 20170809-FBC-DASMA 115 equiy.Ddf Product Approval Method Method 1 Option A Date Submitted 08/10/2017 https://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgv3yVVKJZIQRAbbA5BZkl9lvxlwrUzbhrVbPy2N%2fxxjpA°/a3d%3d 1/6 12/16/2019 Florida Building Code Online Date Validated 11/29/2017 Date Pending FBC Approval Date Approved 12/05/2017 Summary of Products Go to Page — 0 0 0 Page 4/8 10 FL# Model,Number or Name Description 15279.61 061 W5-16 PANSP-2F156: 76SP, Steel Pan(min. 25 ga.)Double-Car(9'2"to 16'0"wide) 76VSP WINDCODEO W5 Garage Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of Approved for use outside HVHZ:Yes inspectign.pdf Impact Resistant:Yes FLIS279 RS C CAC WS Listing Inter ek_df Design Pressure: +32 PSF/-37 PSF Quality Assurance Contract Expiration Date Other:Solid doors(no glazing)or doors with optional impact- 05/21/2028 resistant glazing are impact-resistant(large missile impact). Installation Instructions FL15279 R5 II 103723-A-Rev08.pdf Verified By: Intertek Testing Services NA,Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.62 062 W5-16 SPO-2F449: Grand Steel Pan(min.24 ga.)with Overlay Double-Car(9'2"up to Harbor,Stone Manor 16'0"wide)WINDCODE@ W5 Garage Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FLIS279 RS C CAC Letter with proof of contract and proof of Approved for use outside HVHZ:Yes inspection.pdf Impact Resistant: N/A FL15279 R5 C CAC W5 Listing Intertek.pdf Design Pressure: +30 PSF/-30 PSF Quality Assurance Contract Expiration Date Other:The OPTIONAL glazing available for this product meets 05/21/2028 the wind load requirements of the building code but DOES NOT Installation Instructions meet the impact resistant requirement for windborne debris FL15279 R5 II 103553-Rev06.pdf regions.The product without glazing DOES comply with the Verified By: Intertek Testing Services NA,Inc. impact resistant requirement for windborne debris regions(ref Created by Independent Third Party: 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.63 063 W5-16 W-1B899: Reserve Reserve Wood Double-Car(9'2"To 16'0"wide)WINDCODE® Collection RHxx W5 Garage Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of Approved for use outside HVHZ:Yes i�ection.pdf Impact Resistant: N/A FL15279 R5 C CAC W5 Listing Intertek.pdf Design Pressure: +30 PSF/-33.5 PSF Quality Assurance Contract Expiration Date Other:The OPTIONAL glazing available for this product meets 05/21/2028 the wind load requirements of the building code but DOES NOT Installation Instructions meet the impact resistant requirement for windborne debris FL15279 R5 II 102536-Rev06.pdf regions.The product without glazing DOES comply with the Verified By: Intertek Testing Services NA,Inc. impact resistant requirement for windborne debris regions(ref Created by Independent Third Party: 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.64 064 W5-16-B AL-11`499: AvanteT" Full View Aluminum Residential WINDCODE@ W5 Sectional Door, 12'3"to 16'2"wide Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FLIS279 RS C CAC Letter with proof of contract and proof of Approved for use outside HVHZ:Yes inspect on.pdf Impact Resistant: N/A FL15279 R5 C CAC WS Listing Intertek.pdf Design Pressure: +30 PSF/-30 PSF Quality Assurance Contract Expiration Date Other:The OPTIONAL glazing available for this product meets 05/21/2028 the wind load requirements of the building code but DOES NOT Installation Instructions meet the impact resistant requirement for windborne debris FL15279 RS II 103447-Rev04.pdf regions.The product without glazing DOES comply with the Verified By: Intertek Testing Services NA,Inc. impact resistant requirement for windborne debris regions(ref Created by Independent Third Party: 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.65 065 W5-16-C AL-IF499: AvanteTM Full View Aluminum Residential WINDCODE®W5 Sectional Door, 12'3"to 16'2"wide Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of Approved for use outside HVHZ:Yes inspection.pdf Impact Resistant: N/A FLIS279 R5 C CAC W5 Listing Intgrtek.pdf Design Pressure:+32 PSF/-32 PSF Quality Assurance Contract Expiration Date Other:The OPTIONAL glazing available for this product meets 05/21/2028 the wind load requirements of the building code but DOES NOT Installation instructions https:/Avm.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZlQRAbbA5BZkl9lvxlwrUzbhrVbPy2N°/`2fxxjpA%3d%3d 2/6 12/16/2019 Florida Building Code Online meet the impact resistant requirement for windborne debris FL15279 R5 II 103446-Rev04.pdf regions.The product without glazing DOES comply with the Verified By: Intertek Testing Services NA,Inc. impact resistant requirement for windborne debris regions(ref Created by Independent Third Party: 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.66 066 W5-16-HY DSIE-IA171: 2050, 1-3/8" Double-skin Insulated EPS(exterior skin 27 ga, min.; 2051,2053,4050,4051,4053,62, interior skin 29 ga. min.) Double-Car(9'2"to 16'0"wide) 64,65,62G,62LG,64G,SDP38, WINDCODE®W5 Garage Door SFL38,SRP38, 134, 135, 136,6130, 6131, 6133 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of Approved for use outside HVHZ:Yes inspection.pdf Impact Resistant: No FL15279 R5 C CAC WS Listinq Intertek.pdf Design Pressure: +32 PSF/-32 PSF Quality Assurance Contract Expiration Date Other:The standard glazing available for this product meets 05/21/2028 the wind load requirements of the building code but DOES NOT Installation Instructions meet the impact resistant requirement for windborne debris FL15279 RS II 102185-13-Rev12.pdf regions. Verified By: Intertek Testing Services NA,Inc. Created by Independent Third Party: Evaluation Reports y Created by Independent Third Party: 15279.67 067 W5-16-HY DSIE-1A171: 2050, 1-3/8" Double-skin Insulated EPS(exterior skin 27 ga. min.; 2051, 2053,4050,4051,4053,62, interior skin 29 ga. min.) Double-Car(9'2"to 16'0"wide) 64,65,62G,62LG, 64G,SDP38, WINDCODE@ W5 Garage Door SFL38,SRP38, 134,135, 136,6130, 6131,6133 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of Approved for use outside HVHZ:Yes inspection.pdf Impact Resistant:Yes FL15279 R5 C CAC W5 Listing Intertek.pdf Design Pressure:+32 PSF/-32 PSF Quality Assurance Contract Expiration Date Other:Solid doors(no glazing)are impact-resistant(large 05/21/2028 missile impact). Installation Instructions FLIS279 R5 II 102185-A-Revl2.pdf Verified By: Intertek Testing Services NA,Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.68 068 W5-16-HY PAN-2F143: 84A,94, Steel Pan(min.24 ga.) Double-Car(9'2"to 16'0"wide) 14RST,4RSF,48,486 WINDCODE@ W5 Garage Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of Approved for use outside HVHZ:Yes inspection.pdf Impact Resistant:Yes FL15279 RS CAC W5 Listinq Intertek.pdf Design Pressure: +34 PSF/-35 PSF Quality Assurance Contract Expiration Date Other:Solid doors(no glazing)or doors with optional impact- 05/21/2028 resistant glazing are impact-resistant(large missile impact). Installation Instructions FL15279 R5 II 101922-A-Rev11.pdf Verified By: Intertek Testing Services NA,Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.69 069 W5-16-HY PAN-2F153: 84A,94, Steel Pan(min. 25 ga.) Double-Car(97"to 16'0"wide) 73,75, 1500,190,4RST,4RSF, WINDCODE@ W5 Garage Door 6RST,6RSF,48,42,55,48B,42B, 55S Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 RS C CAC Letter with proof of contract and proof of Approved for use outside HVHZ:Yes I�ection.pdf Impact Resistant:Yes FL15279 RS C CAC WS Listing Intertek.pdf Design Pressure: +32 PSF/-32 PSF Quality Assurance Contract Expiration Date Other:Solid doors(no glazing)or doors with optional impact- 05/21/2028 resistant glazing are impact-resistant(large missile impact). Installation Instructions FL15279 R5 II 101922-A-Revll.pdf_ Verified By: Intertek Testing Services NA,Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.70 070 W5-16-HY PAN-2F153: 84A,94, Steel Pan(min. 25 ga.) Double-Car(9'2"to 16'0"wide) 73,75, 1500, 190,4RST,4RSF, WINDCODE®W5 Garage Door . 611ST,6RSF,48,42,55,48B,42B, 55S Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 115 C CAC Letter with proof of contract and proof of https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZIQRAbbA5BZklglvxlwrUzbhrVbPy2N%2fxxjpA*/a3d°/a3d 3/6 12/16/2019 Florida Building Code Online Approved for use outside HVHZ:Yes inspedion.pdf Impact Resistant: No FL15279 R5 C CAC W5 Listing Intertek.pdf Design Pressure: +32 PSF/-32 PSF Quality Assurance Contract Expiration Date Other:The standard glazing available for this product meets 05/21/2028 the wind load requirements of the building code but DOES NOT Installation Instructions meet the impact resistant requirement for windborne debris FL15279 R5 II 101922-B-Revll.pdf regions. Verified By: Intertek Testing Services NA,Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.71 071 W5-20 AL-1F499: Avante'" Full View Aluminum Residential WINDCODE®WS Sectional Door, 16'3"to 20'2"wide Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of Approved for use outside HVHZ:Yes inspection.pdf Impact Resistant: N/A FL15279 R5 C CAC WS Listing Intgrtek.pdf Design Pressure: +30 PSF/-30 PSF Quality Assurance Contract Expiration Date Other:The OPTIONAL glazing available for this product meets 05/21/2028 the wind load requirements of the building code but DOES NOT Installation Instructions meet the impact resistant requirement for windborne debris FL15279 R5 II 103448-Rev05.pdf regions.The product without glazing DOES comply with the Verified By:Intertek Testing Services NA,Inc. impact resistant requirement for windborne debris regions(ref Created by Independent Third Party: 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.72 072 W6-09 DSIE-1A171: 2050, 1-3/8"Double-skin Insulated EPS(exterior skin 27 ga. min.; 2051,2053,4050,4051,4053,62, interior skin 29 ga. min.) Single-Car(up to 9'0"wide) 64,65,62G,62LG, 64G,SDP38, WINDCODEO W6 Garage Door SFL38,SRP38, 134, 135, 136,6130, 6131,6133 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of Approved for use outside HVHZ:Yes inspection.pdf Impact Resistant: N/A FL15279 R5 C CAC W6 Listing Intertek.pdf Design Pressure: +37 PSF/-37 PSF Quality Assurance Contract Expiration Date Other:The OPTIONAL glazing available for this product meets 05/21/2028 the wind load requirements of the building code but DOES NOT Installation Instructions meet the impact resistant requirement for windborne debris FL15279 R5 II 101654-Revl3.pdf regions.The product without glazing DOES comply with the Verified By: Intertek Testing Services NA,Inc. impact resistant requirement for windborne debris regions(ref Created by Independent Third Party: 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.73 073 W6-09 DSIE-1F171: 4300,4301, 2"Double-skin Insulated EPS(exterior skin 27 ga. min.; 4310,4400,4401, HDG, HDGL, interior skin 27 ga. min.) Single-Car(up to 9'0"wide) HDGF,66, 66G,67,67G,68,SP200, WINDCODE@ W6 Garage Door with Optional Impact-Resistant SF200,SE200, 6200,6201,6203 Lites Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of Approved for use outside HVHZ:Yes ins ection.pdf Impact Resistant:Yes FL15279 R5 C CAC W6 Listing Intertek.pdf Design Pressure: +37 PSF/-40 PSF Quality Assurance Contract Expiration Date Other:Solid doors(no glazing)or doors with optional impact- 05/21/2028 resistant glazing are impact-resistant(large missile impact). Installation Instructions FL15279 R5 II 101526-A-Revl6.pdf Verified By: Intertek Testing Services NA,Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.74 074 W6-09 DSIE-1F171: 4300,4301, 2"Double-skin Insulated EPS(exterior skin 27 ga. min.; 4310,4400,4401,HDG, HDGL, interior skin 27 ga. min.)Single-Car(up to 9'0"wide) HDGF,66, 66G, 67,67G,68,SP200, WINDCODE@ W6 Garage Door SF200,SE200,6200,6201,6203 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of Approved for use outside HVHZ:Yes inspection.Ddf Impact Resistant: No FL15279 R5 C CAC W6 Listing Intertek.pdf Design Pressure: +37 PSF/-40 PSF Quality Assurance Contract Expiration Date Other:The standard glazing available for this product meets 05/21/2028 the wind load requirements of the building code but DOES NOT Installation Instructions meet the impact resistant requirement for windborne debris FL15279 R5 II 101526-B-Rev16.pdf regions. Verified By: Intertek Testing Services NA,Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.75 075 W6-09 DSIE-1F471: GD2SP, Gallery/Artistry/Expressions: 2"Double-skin Insulated EPS GR2SP,GD2LP,GR2LP,AR2SP, (exterior skin 27 ga. min.; interior skin 27 ga. min.)Single-Car https:/Avww.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZIQRAbbA5BZkl9lvxlwrUzbhrVbPy2N%2fxxjpA%3d%3d 4/6 12/16/2019 Florida Building Code Online AR2LP, ED2SP, ED2LP (up to 9'0"wide)WINDCODE@ W6 Garage Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of Approved for use outside HVHZ:Yes insection.pdf Impact Resistant:Yes FL15279 R5 C CAC W6 Listinq Intertek.pdf Design Pressure:+38 PSF/-42 PSF Quality Assurance Contract Expiration Date Other:Solid doors(no standard glazing)are impact-resistant 05/21/2028 (large missile impact). Installation Instructions FL15279 R5 II 103954-A-Rev03.pdf Verified By: Intertek Testing Services NA,Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.76 076 W6-09 DSIE-1F471: GD2SP, Gallery/Artistry/Expressions: 2"Double-skin Insulated EPS GR2SP,GD2LP, GR2LP,AR2SP, (exterior skin 27 ga. min.; interior skin 27 ga. min.)Single-Car AR2LP, ED2SP, ED2LP (up to 9'0"wide)WINDCODE®W6 Garage Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of Approved for use outside HVHZ:Yes inspection.pdf Impact Resistant: No FL15279 R5 C CAC W6 Listing Intertek.pdf Design Pressure: +38 PSF/-42 PSF Quality Assurance Contract Expiration Date Other:The standard glazing available for this product meets 05/21/2028 the wind load requirements of the building code but DOES NOT Installation Instructions meet the impact resistant requirement for windborne debris FL15279 R5 II 103954-B-Rev03.pdf regions. Verified By: Intertek Testing Services NA,Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.77 077 W6-09 DSIEO-1M479: Double Skin Insulated EPS(exterior skin 27 ga. min.; interior Coachman/Settlers/Affinity skin 27ga. min.)with Overlay Single-Car(up to 9'0"wide) WINDCODE@ W6 Garage Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of Approved for use outside HVHZ:Yes inspection.pdf Impact Resistant:Yes FL15279 R5 C CAC W6 ListingIntertek.pdf Design Pressure:+38 PSF/-42 PSF Quality Assurance Contract Expiration Date Other:Solid doors(no standard glazing)are impact-resistant 05/21/2028 (large missile impact). Installation Instructions FL15279 115 II 103223-A-Revll.pdf Verified By: Intertek Testing Services NA,Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.78 078 W6-09 DSIEO-1M479: Double Skin Insulated EPS(exterior skin 27 ga. min.; interior Coachman/Settlers/Affinity skin 27ga, min.)with Overlay Single-Car(up to 9'0"wide) WINDCODE@ W6 Garage Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of Approved for use outside HVHZ:Yes ins ection.pdf Impact Resistant: No FL15279 R5 C CAC W6 Listing Intertek.pdf Design Pressure: +38 PSF/-42 PSF Quality Assurance Contract Expiration Date Other:The standard glazing available for this product meets 05/21/2028 the wind load requirements of the building code but DOES NOT Installation Instructions meet the impact resistant requirement for windborne debris FL15279 R5 II 103223-B-Revll.pdf regions. Verified By: Intertek Testing Services NA,Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 15279.79 079 W6-09 DSIU-1A171: 9130, Double-skin Insulated PUR(exterior skin 27 ga, min.; interior 9131,9133,HDP13,HDPF13, skin 27 ga. min.)Single-Car(up to 9'0"wide)WINDCODE@ W6 HDPL13,7130,7131,7133,8130, Garage Door 8131,8133 Limits of Use Certification Agency Certificate. Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of Approved for use outside HVHZ:Yes insoection.odf Impact Resistant: N/A FL15279 R5 C CAC W6 Listinq Intertek.pdf Design Pressure:+37 PSF/-37 PSF Quality Assurance Contract Expiration Date Other:The OPTIONAL standard glazing available for this 05/21/2028 product meets the wind load requirements of the building code Installation Instructions but DOES NOT meet the impact resistant requirement for FL15279 R5 II 104180-RevOl.pdf windborne debris regions.The product without standard glazing Verified By: Intertek Testing Services NA,Inc. DOES comply with the impact resistant requirement for Created by Independent Third Party: windborne debris regions(ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 15279.80 1080 W6-09 DSIU-1F171: 9200, Double-skin Insulated PUR(exterior skin 27 ga, min.; interior https://www.floridabuilding.org/pr/pr_app_dtI.aspx?param=wGEVXQwtDgv3yVVKJZ1QRAbbA5BZkl9lvxlwrUzbhrVbPy2N%2fxxjpA%3d%3d 5/6 12/16/2019 Florida Building Code Online 9201,9203,HDP20,HDPF20, skin 27 ga. min.)Single-Car(up to 9'0"wide)WINDCODE@ W6 HDPL20,7200,7201,7203,8200, Garage Door with Optional Impact-Resistant Lites 8201,8203 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of Approved for use outside HVHZ:Yes insigggion.pdf Impact Resistant:Yes FLIS279 R5 C CAC W6 Listing Intgrtek.pdf Design Pressure:+37 PSF/-40 PSF Quality Assurance Contract Expiration Date Other:Solid doors(no standard glazing)or doors with 05/21/2028 optional impact-resistant standard glazing are Impact-resistant Installation Instructions (large missile impact). FL15279 R5 II 104184-A-Rev0l.pdf Verified By: Intertek Testing Services NA,Inc. Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Go to Page _ Page 4/8�. Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1624 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privagy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® W.9 F91A9 M Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yWKJZlQRAbbA5BZkl91vxlwrUzbhrVbPy2N%2fxxjpA%3d%3d 6/6 Imi v a Wm v G rLm v Y 1DIO D=HEIGHT I ff U-BARS THE OPTIONAL GADO SHOWN ON 7HS DRAWING MEET+'THE END REV DATE IES[ABTI[N SECNIINS WIND LOAD REOUIREME?TS OF THE FLORIDA BUMDIND CODE UP T13 7101 4 OR INTERNATIONAL OLIUM CODE BUT DOES EM MEET IHE STILE 07 09/2005 ADDED ROLLER OPTION DD+W bm� I'm� 4m.— 7•B'70 e's' S 0 NPALT RMSTAHF REQUIREMENT FOR WINDBORNE DEBRIS INTER. r0' 1 A•e• B 111 REGIONS REF.CHAPTER fe FM/MCI BD c STILE 08 11/30/07 COMBINED CLOPAY, HOMLES, & IDEAL M N IUAo v'Au1rE6A a"' M•say f112 lar TO tri• 7 14 7IOS DOOR Ems OR EXCEEDS THE oma+LOADS FOR THE 09 10/21/08 ADDED M/N 62G AND 64G,ADDED MPC Erb•70 tar R 16 ULIU E WHO SPENDS ISTD BELOW AeatmOm TO 7HE FUNODA OUTSIDE a"I mm ' w ""'1s4 u'2'TO 15.9' 9 19 WILLING CODE OR THE NTINOONIL MUM CODE(BASED ON HANDLE 10 12/13/10 ADDED IMPACT-RESISTANT CONSTRUCTION NOTE. ASCIET-10)FOR THE IMIDWINO CONDITION&1)ENCLOSED Iso• H) M DWI LWA 2)DOOR HO r OF WIDTH N BUIDNG'S END ZONE. 11 1/26/11 AOOm UPDATED MODEL NUMBERS. NAx sEcrmN HEIGHT. el• ANT ROOF SID'AND 4)TESTING N AaIOlDaCE WITH LOCK BAR 12 01/31/12 REVISED WIND SPEED TABLE FOR A.SCE7-10. 9199 tos DTTF DgMOWC CYDYATIOI9 Br A D9BiIE0 ENGAGES IN PIIOIML wY I2NTER. 8'THICK TRACK ON a7au1E vum OUTSIDE KEYED LOCK EACH SIDE OPTIONAL S A ACRYLIC OR OSB ®OM He 145 1:D ISO En LACK BAR LOCKING 1-3 —I GLASS LRES AVAILABLE OPTIONAL SFOF DOOR. / ACRYLIC GLAZING IS PLASKOLRE OPRX CATEGORYDMSLIRE >t,c,n n,c,a W,c s,c W OR LUCITE CP APPROVED CC2 PLASTIC SLIDE BOLT B IN ACCORDANCE WITH IBC/FBC 26%B WAN ROD'HEIDT B5' t9 a' u• 5r END LOCK ENGAGES 12 GA. GALV.STEEL TOP ROLLER BRACKET. r SEE SECTION B-B a , STILE INTO VERTICAL SHEET MAAKEr TrAC ED WITH (4) 114.5/8- TRACK I 14x5/8'TRACK. ONE LOCK ON EACH SIDE $4 2A OF DOOR. o IENGAGESINSIDE SUDE BOLT SNAP LATCH CK. LOCK OPTION ONTO VERTICAL TRACK. 9 ONE SNAP LATCH ON 1 POUND DENSITY LYST EACH SIDE OF DOOR. EXPANDED POLYSTYRENE 27 GA.STEEL MIN. EXTERIOR FOAM INSULATION LAMINATED INTER.STILE SKIN WITH A INTERIOR SKEIINES. AND BAKED-OD-O N PRIMER AND _ POLYESTER PAINTED TOP COAT. OUTSIDE KEYED ENO HANDLE STILE TONGUE AND GROOVE JOINTS. END HINGE EACH 14 GA. GALV. STEFl. FA5TI7JED TO END STILES W/(4) X INSIDE HANDLE 14x5/8'& (4) 1/4'x3/4'SEF SHEET LOCK POSITION pUT510E KEYED LOCK ETAL SCREWS TAPPING SCREWS.114x5/8'SHEET (BOTH SIOFS) SNAP LATCH LOCK OPTION METAL SCREWS 3'TALL x 20 GA.GALV.STEEL.U-BAR. I WITH K51 YIN.TWO PER SECTION.ATTACHED L 7W0 3'TALL x 20 GA. GNLV. WfIH 7W0 1/4'x34'SELF TAPPING (OPTIONAL OUTSIDE KEYED LOCK POSITION J STEEL U-BARS PER SECTION. SCREWS PER HINGE LOCATION. A*"-" BD KSI MIN. 1/4'x3/4'SELF 29 GA. STEEL MIN. INTERIOR GALV. INSIDE ELEVATION—MAX. DOOR WIDTH - 18'-0' O TAPPING SCREWS D AND ABABAKED ONmPOLYYES PRIMER TOP COAT. '[INSTALLER (TOBYSUITDOOR (SHORT PANEL SHOWN) 13 GA GALV. STEEL BOTTOM vmrx•� TA1ra arAnaExr NWum Wnur ar 2x6 YELLOW PINE JAMB 20 GA.MIN.GALV.STEEL END STILE 14 GA. END HINGES 18 GTL. INTERMEDIATE HINGE 01x5/8'SHEET MET WITH (2) S d'LAO SCREWS ON 24'CENTERS.1-1/p O.D. VIEW B WASLIEIE RBOUNm.LAD SCREWS MAY BE CaONLBtSUNK VIEW C SCREWS. ((RBU0EN Tar REouwEv)ro PRovInE A FlJ15H MOUNTING ALUMINUM EXTRUSION SURFME HORQOMAL.Wes DO NONTRANSFER LOAD. 12 G4 GALV. STET.TRACK &VINYL WFJRHf715TRIP. 0 � BRACKET FASTENED TO WOOD SECTION A-A uN.raFroEr,-reL,x,r,D- JAMB WITH ONE 5/18'x1-5/8' z/e13'SLEEVE A40M=39 ON 14'MUM(2,000 WOOD LAG SCREW PER BRACKET. TxD mFwww AADWTCGoa voWo P9 Mw.coNaaTE).WASFFIS Na11aD xlnR StEfVE 7/11)'I.D. ROUND FA GA MIN. GCEN STEEL INTER. HINGE _ U EACH TO CENTER STILE L SC ULLHORZDKD�DOG"Tari axra etMar ne�a Dao eaw vTIB Toa. DOOR Nmum A�la 2'GALV. K BR TRACK P SHN E FROLLER). EACH 114x5/8'SHEET METAL SCREWS. IxIOe IsrAI1B1 DO wO 1/413'TTPCON SUMS ON 127 CENTERS(2.000 PSI FASTENED TO TRACK BRACKETS. (ONE PER ROLLER). DOas MER If Tui e'tLt DOaits AND 11t"ERR 1@L�p MOR Y cEHLEAs(o-9a BIDCK).f'O.D. EACH BRACKET ATTACHED WITH ONE wA4RF7S REDTNWITH TAPCONS 1/4'x5/8'BOLT&NUT 9$ 14 GA GALV. STEEL ROLIEE7 HI GE is Dt oALv.sTNa FtAO elAa¢r. ) 7W0 1/4'RIVETS. FASTENED TO END STILLS W/ EACH (�ejte�°-0/e tEACH atv SIM�a"� ANCHORS AWHUSFI Y NK NSE FWfaQROHN�JIL� JAMB CONFIGURATION 14x5/8'SHEET METAL.SCERF AND r DAM SIM TWACK (Nate 1-0�WOOD IAO SCREI& PROVIDE DO Tar mAtawn LOAD. 4) 1/4'x3/4'SELF TAPPING SCREWS. TM+�O4cD®aeD'ICL •REFER 70 txvu TDs-f e1. ' 10 BALL SHORT STEM STEEL ROLLER NIi.D 2-1 ti12 DL aEv 7wac OW4W. e TFW"=euaers rtx 10' A 1tcNRsm DF.swN PRGFFSSIORUL MAY ALSO BE WITH STEEL OR NYLON TIRE. BETWEERITSRARpSIDE UP T=a iEal,N IxIOR [OEPLIIRED la APPROVE AL7FJ6EA7E FASTENERS AND/OR NOf TO Da�ID]D'ODT JAMB CONFW77RA7PDW, T � t. E Y aLV.SIEELL TRILTL NPACN=STANN ASSE_Y DEEMS STAN04TD ASSETIBLY DEEMS t.' t1K 7RAd TDILaO1Rs.OeD' DMWIND tOEteS.a ow m As Tozleo.w SECTION B-B ENON-IYPACN RESISTANT CIA2IN0 aPUDNI ORIOWL DMWWOS AE 901ED!I BLUE 7 -FOR DDaD al Dy IIP.2-1/2112 fA GLLV.2mm TRAIX wVORT. N(WON A RAM SEAL lwmOB9} � l2 OONFVJV�g�NDT � (4)��S f4J1 SDE "(COED M "SPAOIO PICA=CDR=la 1 1/r FOR M= F� IMPACT-RFSISrAN4r CONSTRUCTION: �� •W' SOLA DODRS NO GIAZ1N01 A!E TIRADE-A6ISNANr.TFE OEM Daae r B7STALLID w aBa'uANCE Wtn( ESIGN LOADS: +32.0 PSF do-32.0 PSF MWS SECTION MEETS THE WIND TEST LOADS: +48.0 PSF&-48.0 PSF THE FIORDA BIIIDNO CODE AND DEfammoN4. OPTIONAL DSB OR 1 e'ACYROC LUES AVNUBIE BU LIKHO CODE ALL3)®a IRE WAON-RESISTANT VDaLMO IN77NG NAIL Det S� HEn�m+1s RF.cHunRn 1e tec aPnaEw Aamtc No Is PIAKaIIE oPIIX OR MPC(DSIE-HAITI 16'W x 16'H UITI a'APP. CC2 PLASTIC O ABODE Wm1 C 2BD<.S C opay �� 4,20,2000 w5 THE' DOOR •NSNAl1ID w CaYRRANCE NTLI THIS SECTION MEETS THE WIND LOAD REOueE»rTNNrs of THE NDRIDA BUILDING CODE OR 65115 DUKE BLVD. 2050/4050/4053, 16'W, f32PSF RNIFANAIONEU.NUl1MN0 COOT BUN YEkT IGD ENGINEER:#8 MILK WES�ETT'-P.E Building Products MASON,ON 45040 ORAVN 3" MWW THE WPAOr kloUWL NT REVONFLERT DBORNE FLORIDA P.E 149496. (513)770-4600 ORAVD1f EAIa[7c VE1b DEBRIS REMS REF.CHAPTER 1e FBC NOITEP.P.E.197613 CORD On CFECIIED ELY DC a.M CoTaretim M RgWt.R. & B 102165 - A/B O D p p FRUDUCT p D D D O p o , , . ` mtertek Testing Services NA,Inc. Tel+1-608-836-4400 N� 0te� te k mumv�h o�e m�+�o��ae�7�� mm Middleton,WI 52562 vmww'/mertek.mm Total Quality.Assured. Issue Date:October 4` 2O17 Letter Report No: 10324267W4|D-001a Mr.Scott Hamilton, P.E. OmpayBuilding Products Company Em/ai|:shammikon@dopaycorn QSOSDuke boulevard Mason,OH4S040 Sybiect: Intertek Listings that support FL 15279 for compliance with the Sixth Edition of the Florida Building Code(2017) Dear Mr.Hamilton, This|etternepresentstheresu|tsofintartek'srevewmfthe|ntertekLbtn8sthatcurrentlysupport[1opay FL15279product approval. |ntertekaffirms that the|nterteh Listed products included in Florida Product Approval FL 15279 maintains compliance with the Sixth Edition ofthe Florida Building Code (3Ol7). Intertek has verified that the referenced certification documents are currently under surveillance services with |ntertehfor the Florida Building Code. Attached isthe current Certification Agreement between |ntertekand Clopay Building Products. This agreement also may be referenced as a QA contract that bears no expiration date and as such does not expire except upon it's termination and is valid indefinitely. Sincerely, UNTERTGK TESTING SERVICES NA,INC. Reported by: Reviewed by: John Schachtner ~ |Kooner, P.En8' Project Engineer-Evaluation Services Oirector—Ena|uabonSenviceu Inmertek Inmermek mterteu This report is for the exclusive use of InterleWs Client and Is provided pursuant to the agreement between Intertek and its Client Intertelft responsibility and liability are limited to the terms and conditions of the agreement Intertek assumes no liability to any parly�other than to the Client In accordance with the agreement,for any loss,expense or damage occasioned by the use of this report.Only the Client is authorized to permit copying or distribution of this report and then only in its entirely. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,product or service must fast he approved In writing by Intertek. The observations and test results in this report are relevant only the sample tested. This report by itself does not Imply that the material,product or service is or has ever been under an Intertek certification program. Version:O2August IO17 Page 1of1 SFT-BC-OP-19b 0. 8431 Murphy Drive Middleton,Wl 53562 Intertek Telephone: +1 608 836 4400 L Facsimile: +1608 8319279' www.Intertelcoom MMUFACTUREWS CERTIFICATION AGREEMENT THIS AGREEMENT made the 12th day ofrua between INTERTEK _Egk—_M,2010, by and TESTING SERVICES NA INC.having offices at 8431 Murphy Drive,Middleton,WI USA(nintertek!')and Clopay Building products Company,Inc. having offices at (Manufacturer Company Name) 1400 W.Market Street,Tr6y,OH 46373 USA {"Client"). (Manufacturer Company Address including Country) RECITALS Intertek provides a service for evaluating whether products provided by the Manufacturer comply with designated standards or specified requirements, Subject to the terms of this Certification Agreement, Products found to be in compliance by Intertek may be eligible for inclusion on a list maintained by Intertek for Products to display a Certification Mark owned by Intertek. Another party (the "Client") desires to submit or has submitted to Intertek certain devices, equipment, materials, or systems manufactured by the Manufacturer for the Client for evaluation in order that the product may be considered for Listing and Labeling by Intertek. If the submitted product is found to be eligible for Listing, Labeling, and Follow-up Service, this Certification Agreement shall be executed by Intertek and the Manufacturer setting forth the terms and conditions to which the parties hereto must adhere. NOW THEREFORE, for and in consideration of the mutual covenants herein expressed and other lawful and valuable consideration,the parties hereto agree as follows-, 1 DEFINITIONS 1.1 Authorization to Mark.The term Authorization to Mark ("AW) shall mean a written document from Intertek that authorizes the Client and/or Clients Manufacturer to apply an Intertek certification mark to a specific product. 1.2 Certification Mark. The term Certification Mark("Mark")shall refer to any common law or registered trademark owned by Intertek,or its affiliates,used in the certification of Product 1.3 Follow-up Service. The term Follow-up Service shall refer to the process of monitoring the Manufacturer's compliance with the Intertek Requirements. 1.4 Intertek Requirements. The term Intertek Requirements shall mean(a)the requirements contained in the Listing Report, (b) the standard(s), if any, applicable to the Product (c) the terms of this Certification Agreement and(d)any requirements separately applied as a condition of the Listing. 1.6 Labeling. The term Labeling shall refer to the process of applying the Mark to the Product, whether the Mark is applied to the Product by a separable label, directly on the product, or by other media as authorized by Intertek. 1.6 Listing. The term Listing shall mean the process of preparing and including the Product in the published directory of Intertek certified products. Jo� <@> VvTS/mm 11109109 8D 16.3.40(1119/09)Mand ftWek Intertek Intertek Intertek Intertek Intertek 1.7 Listing Report, The term Listing Report shall mean the document prepared by Intertek, also known as Factory Audit Manuel(FAM),which identifies the Client,the Manufacturer and the Product, and specifies Intertek Requirements for the Product including the type and form of Mark which must be used on or in connection with the Product and related Information. 1.8 product The term Product("Product') shall mean a Clienrs device, equipment, material, or system manufactured by the Manufacturer,that has been submitted for testing or evaluation,found to be in compliance with Intertek Requirements and approved for Listing. 2. CERTIFICATION 2.1 Work Authorization, Except to the extent Intertek shall reasonably deem necessary in order-to.respond to an allegation that a cedlfi@_d Product in the marketplace Is non-compliant or in the ordinary course of follow up service that are required for continued listing, Intertek shall not perform any services under this 6greement unless and until authorized byClient pursuant to a propose pertaining to a particular Product that contains a scope'of work, pricing and other terms agreed by the oartles, and signed by an authorized representative of each party 22 Testing and Evaluation. Intertek Is an independent laboratory providing testing and evaluation services to determine whether representative samples of a Product comply with designated national and international standards, specifications, and/or codes. Intertek does not publish standards, specifications, and/or codes, and, therefore, does not warrant to the Client or the Manufactfirer that the standard used for the evaluation is adequate. The Client and the Manufacturer understand and agree that Intertek has only tested or evaluated the submitted Product samples and does not guarantee or warrant the quality or compliance of all units of the Product manufactured or produced by the Manufacturer. The Manufacturer further acknowledges that as an independent laboratory, Intertek assumes no responsibility for the production of the Product. 7-3 Client Obligations. The Manufacturer understands Its obligailons pursuant to this Certification Agreement In order to maintain eligibility for Listing, and warrant's that it shall comply with the following provisions: (a) The Manufacturer agrees that If the Client or Manufacturer wishes to modify or change the Product such that the Product no longer meets the requirements of the Listing Report for the Product the dient or Manufactdrer must first either obtain the approval of Intertek or discontinue use of the Mark. The Product may no longer be eligible for Listing if it has been modified or changed by the Client or Manufacturer after InterteWs testing or evaluation, (b) Upon request the Manufacturer agrees that it shall retain or make sample a available of the a certified product from the most current production. (c) The Manufacturer agrees to notify Intertek in writing of any reports that it receives of serious personal Injury or property damage Involving the Product. (d) The Manufacturer shall notify intertek of any labeled Product which has left the control of the Manufacturer that does not comply with Intertek Requirements. (e) The Manufacturer warrants that a quality control program is, or will be, established and maintained to ensure Product compliance with the Intertek Requirements. 2.4 Reservation of Rights. Intertek reserves the right,upon reasonable written notice to the Client,to re-evaluate the Product at the Clients expense. This re-evalubtion may be the result of Follow-up Service,a revision ofthe applicable standard, new information regarding the characteristics of the material used in the Product,or other information that raises a question concerning the conformance of the Product to Intertek Requirements. 2.5 Revision or Withdrawal of the Intertek Requirements. Intertek reserves the right upon reasonable notice to the Client, to revise or withdrew the Intertek Requirements. If the Intertek Requirements are revised, the Client and the Manufacturer shall be entitled to continue Listing and Labeling of the Product upon a demonstration to the satisfaction of Intertek that the Product compries with the revised Intertek Requirements. If the Intertek Requirements are withdrawn, the Clients and the Manufacturer's right to the Listing and Labeling of the Product shall terminate pursuant to the terms of WTS/mm 11109/09 Page 2 of 5 SD 16.$Ae(1119109)Mandatory Article 6 of this Certification Agreement In the case of a revision or withdrawal of Intertek Requirements, Intertek shall provide a notice specifying a date by which the Product'must meet the revised Intertek Requirements or for such termination. 3. LISTING AND LABELING 3.1 Ownership of the Mark. Ownership of the Mark and all trademark rights In the Mark remain in Intertek, even if it Is used on the Product. The Mark shall only be applied to a Product that complies With the Intertek Requirements and such Mark shall be applied as specified In.the Listing Report. The Mark may be applied only to those models and brands that are specificiilly named In the Listing Report at the factory receiving active Follow-up Service and as noted on the Authorization to Mark. Except as provided herein and as indicated in Article 3.2, any other use of the Mark, or the lntert�k name, on the Product is wcVressly prohibited. 3.2 Follow up Service. As a part of the Listing and Labeling of the Product,the Manufacturer shall cooperate with the Intertek representatives who conduct Follow-up Service. Follow-up Service may include factory audits at any time during business houri and such Intertek representatives shall have free, unannounced, and immediate access to the Manufacturer's premises wherein the Product or components thereof, may be fabricated, processed, finished, stored, or located. Intertek-representatives shall comply with factory policies as required while on premises. Follow-up Service Is intended to allow Intertek to monitor the Manufacturer's compliance with maintaining continuing conformity of the Product to the Intertek Requirements, and to control the use of Intertek's Marks.The fia'atory audits are not intended to satisfy or otherwise replace Manufacturer's responsibility to maintain its quality'control program and to ensure that the Product remains in the compliance with the Intertek Requirements, Follow-up Service may also include Manufacturer questionnalre,13, and/or the Manufacturer's warranty of conformity. Intertek has the right to perform'a final factory inspection to record final production status and to recover all unused Intertek Certification Marks upon notification of termination of th6 Authorization to Mark. Fees for a final inspection will be Willed in accordance With Article 7.3 of this Certification Agreement. 4. INDEMNIFICATION AND LIABILITY 4.1 Indemnification. The Manufacturer agrees to hold Intertek harmless and to defend and Indemnify Intertek against any liability,-loss,or damage from claims,demands, costs(including legal fees), or judgments arising out of any negligent or intentional acts of the Manufacturer relating to the Product or arising from the use of the Mark. 4.2 Liability. Intertek will not under any circumstances, be liable to the Manufacturer for any indirect, special, punitive, or consequential damages, or any third party claims which may arise as a result of the services provided in this Certification Agreement 6. FA16ge To commy wrrH INTERTEK REQUIREMENTS 6.1 Remedial Action. In the event that Interiek detects any deviation or variance in the Product from Intertek Requirements,or Improper or unauthorized use of the Mark or Intertek name, upon written notice to the Client Intertek reserves the right in Its sole discretion,to take such action as it deems necessary,including but not limitdd to: (a) Requiring the Client, at its own expense, to undertake corrective action to ensure that the Product complies with Intertek requirements, (b) Suspension or revocation of the Listing and the right to label the Product (a) Withdrawal of the supply of labels and removal of the Mark from non-conforming products; (d) Removal of the Product from the Intertek Directory of Listed Products; -(e) Termination of this Certification Agreement pursuant to Article 6; VVTS/mm 1'1109109 Page 3 of 5 SD 16,3.4o(11/9M)Mandatory Notification of regulatory authorities and the public; (9) Compliance with any applicable statutes,rules,or regulations, 6.2 Injunctive Relief. The Manufacturer acknowledges that the manufacture, sale, delivery, shipment,distribution,or promotion of the Product utilizing a Mark w6uld mislead or endanger the public if such Product is not eligible to use the Mark or does not comply with v the Intertek Requirements.- The Manufacturer further acknowledges that a breach of this Certification Agreement can not be adequately compensated by money damages. The ManActurer agrees that in the event of a breach of'the Certification Agreement Intertek shall have the right to obtain a temporary restraining order without prior notice to the Manufacturer, together with an action for a preliminary and permanent injunction, and such other and further relief as may be provided by law, Said injunction shall prohibit the Manufacturer from further use of the Mark and shall require the Manufacturer to comply With the provisions in Article 6.3 of this Certification Agreement 6.3 Suspension. Up6n a Clients or a Manufacturer's failure to comply with any of the requirements of this Certification Agreement or Listing Report, Intertek may issue a letter of suspension which shall no*the Client of the nature of the failure and the period of suspension of the Clients right of Labeling. In the event that the Client falls to take corrective action to resolve the cause of suspension,this Certification Agreement shall be terminated'pursuant to Article 6. 6.4 Public Notice. In the event that Intertek has confirmed evideh ce that the.Product duct in the marketplace has a significant non-conformity, Intertek will contact the Client and act in support-of remedial steps taken by the Client to address the non-conformity, Including, if necessary, public notification and/or a product recall undertaken by the Client. In the event-that the Client does not take action to address a significant non-conformity related to the Product, Intertek reserves the right lo contact appropriate government agencies,other parties In the supply chain and/or issue public notifications advising of the non- conformity pursuant to Article 6.1(Q above. 6. TERMINATION OF THE AGREEMENT 6.1 Termination By Either Party. Either -party may, for any reason, terminate this Certification Agreement, as to any Product, upon not less than sixty (60) days written notice to the other party. Suchnotice shall designate a termination date and the notice period-shall be deemed to commence upon.the date of mailing of the notice to the other party by registered or certified mail, return receipt requested or by courier with confirmed delivery. ► 6.2 Intertek Right To Terminate. Intertek may terminate this Certification Agreement as to any Product, without prejudice to any other rights or remedies that Intertek may have, upon either of the following: (a) Immediately upon written notice, If Intertek determines that the Product falls to comply with the Intertek.Requirements or the Client is in default pursuant to Article 7.3; (b) Thirty (30) days after the Client receives written notice in the event of (i) the filing of a voluntary or involuntary petition In bankruptcy, (il) the making of any arrangement or composition with creditors by the Client (111)the appointment of a receiver for the Client, or(iv)the voluntary or involuntary liquidation of the business of the Client 6.3 Obligations Upon Termination. Upon termination of this Certification Agreement the Client and the Manufacturer shall: (a) Discontinue the use of the Mark on the Product or Clients promotional material or advertising. (b) Promptly return to Intertek all Marks, Labeling material,and the Listing Report and warrant in writing the date of last use of the Mark. VVTS1mm 11109/09 Page 4 of 5 80 16.$,4e(I V9/09)Mandatory FEW (c) Continue to honor the terms of Article 4: of this Certification Agreement concerning indemnification and liability,which terms shall survive the termination of this Certification Agreement. (d) Pay any remaining outstanding charges owing to Intertek. 7. ADMINISTRA-WE PBgYLSIONS 7.1 Confidentiality. Without written authorization from the Manufacturer, Intertek will not voluntarily disclose to third parties confidential and proprietary information which the Manufacturer provides to Intertek This obligation shall not'apply to Information which Is already available to the public, or acquired from other sources without confidentiality restrictions,or Is required to be disclosed by Intertek to Regulatory Authorities responsible for the acceptance of the Product Intertek agrees that this obligation to maintain confidentiality shall survive the termination of this Certification Agreement. 7.2 Subpoena. If Intertek Is served with a Subpoena, Court Order, or similar document requesting the disclosure of confidential or proprietary information supplied to Intertek by the Manufacturer, Intertek shall promptly notify the Manufacturer. In the event that the Manufacturer chooses to contest the request, Intertek shall cooperate with the Manufacturer. The responsibility for contesting the request shall rest sot*with the Manufacturer. If the Manufacturer declines to contest the request or Is not successful in contesting the request Intertek will provide the requested information. Any costs incurred by Interlek In responding to the request Including reasonable attorney's fees, shall be reimbursed by the Manufacturer Immediately upon invoicing by Intertek. 7.3 Fees. Certification fees for maintaining the Listing,conducting the Follow-up Service,and licensing of the Certification Mark will be prepaid or billed to the Client or a designated payor. Payment shall be due upon presentation of Invoices and the Client shall be considered in default If the charges are not paid within thirty(30)days, Certification fees are non-refundable. 7.4. No Assignment. The rights running to the Manufacturer under this Certification Agreement may not be assigned to or acquired by any other person or corporation without Intertek's written authorization. 7.6 Tenn. This Certification Agreement shall continue In effect for a period of one year from the date first above written and shall automatically be renewed thereafter for periods of one year, unless the termination rights provided for In this Certification Agreement are exercised, 7.6 Jurisdiction. This Certification Agreement shall be interpreted in accordance with and governed by the laws of the Jurisdiction within which the Intertek office stated in the opening'paragraph is located. Intertek Test g rvlces NA Inc. Accepted By:C!2pay Building Products Company,Inc. pany Name) By. By: (Signature o Intertek Individual) (Proprietor,Penner air rued Officer-Signature) By. Sob Davison BY: )VIq (Name of Authorized Individual-Printed) Title: 01tregor dVMI Cord A&�'IVF V11V Certification Title' V I eA Date Signed: Date Signed: 2-/Z, WTS/mm 11/09/09 Page 5 of 5 8D 16.3.4e 011.9/09)mandatory Report prepared for:Scott Hamilton(Clopay Building Products Co.,Inc.(CBPC))on 5/29/2014 10:56:59 AM Q —'�PecDRECT POWEIREDBY rim -1e;k L -A LISTING INFORMATION OF Clopay WINDCODE@ W5 Sectional Doors SPEC ID' 32639 Clopay Building Products Co., Inc. (CBPC) 8585 Duke Blvd. Mason, ON 45040 This report is for the exclusive use of InterteWs Client and is provided pursuant to the agreement between'Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party, other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this report.Only the Client is authorized to permit copying or distribution of this report and then only in its entirety.Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek.The observations and test results in this report are relevant only to the sample tested.This report by itself does not imply that the material, product,or service is or has ever been under an Intertek certification program. Clopay Building Products Co.,Inc.(CBPC)132639 1 Rev:Oct 16 2013 12:5 IPM I Uncontrolled Copy Page I of 4 Report prepared for:Scott Hamilton(Clopay Building Products Co.,Inc.(CBPC))on 5/29/2014 10:56:59 AMS r. POWEREDBYM WIND RESISTANT DOORS Clopay WINDCODE@ W5 Sectional Doors Clopay WINDCODE@ W5 Sectional J Doors Impact Max. Design Design Rating Width Pressure Pressure Pos. Neg. Single Car Double Skin EPS N/A +30 PSF -32 PSF lGallery/Artistry/ Expressions ISingle Car Double Skin EPS with Overlay N/A +33 PSF -37 PSF Single Car Double Skin PUR N/A 9,-0tf +30 PSF -32 PS jSingle Car Double Skin PUR with 91-0.1 N/A 0.1 +30 PSF 1 -32 PSF7 036 Singler Car Steel Pan I Yes +30 PSF -32 PSF 037 Singler Car Steel Pan No +30 PSF -32 PS 03.8 Singler Car Steel Pan N/A 91-01, +30 PSF -32 PSF Gallery/Artistry/ Expressions 039 Singler Car Steel Pan No +32 PSF -37 PSFLI 040 Singler Car Steel Pan Yes +32 PSF_ -37 PSF 041 Singler Car Steel Pan with 9--o- 30 PSF w-32 PSF [single-car Reserve Wood N/A 9,_01. +32 PSF -36 PSF Double Car Reserve Wood N/A 16'-0" 0 PSF -33.5 PSF Full View Aluminum 12,'2" r712_2'-]l +32 PS -32 PS IFull View Aluminum-16'2" N/A 16-2" +30 PSF] -30 PSF Full View Aluminum(2) 16'2" N/A 1 +32 PS -32 PSE] Full View Aluminum 20'2" N/A 20-2" 0PSF_�F � -30 PSF Double Car Double Skin EPS No 16'-0" +30 PSF -30 PS Double Car Double Skin EPS Yes 16'-0" +30 PSF—r -3-0 PS Double Car Double Skin EPS (46) N/A +30 PSF -30 PSF Gallery/Artistry/ Expressions Double Car Double Skin EPS (47) 2" N/A =16-0' +30 PSF -30 PSF Gallery/Artistry/ Expressions Double Car Double Skin EPS with N/A 16'-0" +30 PSF -30 PSF Overlay (48) Clopay Building Products Co.,Inc.(CBPC)132639 1 Rev:Oct 16 2013 12:51PM J Uncontrolled Copy Page 2 of Report prepared for:Scott Hamilton(Clopay Building Products Co.,Inc.(CBPC))on 5/29/2014 10:56:59 A 4Sp c'DllREcT P& qu sy Double Car Double Skin EPS with N/A 16'-0" +30 PSF -30 PSF Overlay (49) 2" _ Double Car Double Skin PUR N/A 116'-0" +32 PSF -32 PSF Double Car Double Skin PUR with N/A 16'-0" +30 PSF -30 PSF Overlay 052 Double Car Steel Pan Yes 16'-0" +30 PSF -30 PSF 053 Double Car Steel Pan No 16'-0" +30 PSF -30 PSF 054 Double Car Steel Pan No 16'-0" +30 PSF -30 PSF 055 Double Car Steel Pan Yes 16'-0" +30 PSF -30 PSF Double Car Steel Pan Gallery/Artistry/Expressions N/A 16'-0" +30 PSF -30 PSF 058 Double Car Steel Pan I Yes 16'-0" +32 PSF -37 PSF 059 Double Car Steel Pan I No 16'-0" +32 PSF -37 PSF 060 Double Car Steel Pan No 16'-0" +32 PSF -37 PSF 061 Double Car Steel Pan Yes 16'-0" 1 +32 PSF -37 PSF 062 Double Car Steel Pan with Overlay I N/A 16'-0" +30 PSF -30 PSF -T IDouble Car Double Skin EPS I No 16'-0" +32 PSF -32 PSF Double Car Double Skin EPS IF Yes 16'-0" +32 PSF -32 PSF 068 Double Car Steel Pan Yes 16'-0" 1 +34 PSF -35 PSF 069 Double Car Steel Pan Yes 16'-C- +32 PSF -32 PSF 070 Double Car Steel Pan ! No 16'-0" +32 PSF -32 PSF Single Car Double Skin PUR N/A 9'-0" +30 PSF -32 PSF Gal lery/Artistry/Expressions Dobule Car Double-skin PUR (1-3/8") N/A 16'-0" +30 PSF -30 PSF Gallery/Artistry/Expressions Double Car Double-skin PUR (2") N/A 16'-0" +30 PSF -30 PSF Gallery/Artistry/Expressions Attribute Value Criteria ASTM E330 (2002) Criteria ASTM E1886 (2002) Criteria ASTM E1996 (2002) CSI Code 08 30 00 Specialty Doors and Frames Intertek Services Certification Listed or Inspected LISTED Clopay Building Products Co.,Inc.(CBPC)132639 1 Rev:Oct 16 2013 12:51PM I Uncontrolled Copy Page 3 of 4 Report prepared for:Scott Hamilton(Clopay Building Products Co.,Inc.(CBPC))on 5/29/2014 10:56:59 AMQnE?,,DIRECT POWERED By Listing Section WIND LOAD RESISTANT DOORS Report Number 100487442MID-002, 101196252MID-001 SpeclD 32639 Static Load Test- Design See Table Pressure Test Original Issue Date 2012-01-26 Clopay Building Products Co.,Inc.(CBPC)132639 1 Rev:Oct 16 2013 12:51PM Uncontrolled Copy Page 4 of 4