HomeMy WebLinkAboutProduct Approval 12/16/2019 Florida Building Code Online
FWMDA WARM=Or
Professional Regulation
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge + Stats&Facts I Publications I Contact Us I, BCIS Site Map'I Links I 'Search I
a
db
R M Product Approval
f r E - USER.Public User - --"`
Product Aoyroyal Menu>Product or AQplication Search>Application List>Application Detail
DECC 18 2019
° FL# FL15279-R5
F Application Type Revision ST. Lucie County, Permitting
Code Version 2017
Application Status Approved
Comments reapply 11/28/1
A - 'OPY
Archived r— I L 1= U
Product Manufacturer Clopay Building Products Company
Address/Phone/Email 8585 Duke Blvd.
Mason,OH 45040.
(513)770-6062
mwesterfield@clopay.com
Authorized Signature Scott Hamilton
shamilton@clopay.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Sectional Exterior Door Assemblies
Compliance Method Certification Mark or Listing
Certification Agency Intertek Testing Services NA,Inc.
Validated By Gary Pfuehler
i6 Validation Checklist-Hardcopy Received
Referenced Standard and Year(of Standard) Standard Year
ANSI/DASMA 108 2005
ANSI/DASMA 115 2005
ASTM E1886 2002
ASTM E1996 2002
ASTM E330 2002
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL15279 R5 Equiv 20170809-FBC-DASMA 108 eouiy.Ddf
FL15279 R5 Equiv 20170809-FBC-DASMA 115 equiy.Ddf
Product Approval Method Method 1 Option A
Date Submitted 08/10/2017
https://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgv3yVVKJZIQRAbbA5BZkl9lvxlwrUzbhrVbPy2N%2fxxjpA°/a3d%3d 1/6
12/16/2019 Florida Building Code Online
Date Validated 11/29/2017
Date Pending FBC Approval
Date Approved 12/05/2017
Summary of Products
Go to Page — 0 0 0 Page 4/8 10
FL# Model,Number or Name Description
15279.61 061 W5-16 PANSP-2F156: 76SP, Steel Pan(min. 25 ga.)Double-Car(9'2"to 16'0"wide)
76VSP WINDCODEO W5 Garage Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspectign.pdf
Impact Resistant:Yes FLIS279 RS C CAC WS Listing Inter ek_df
Design Pressure: +32 PSF/-37 PSF Quality Assurance Contract Expiration Date
Other:Solid doors(no glazing)or doors with optional impact- 05/21/2028
resistant glazing are impact-resistant(large missile impact). Installation Instructions
FL15279 R5 II 103723-A-Rev08.pdf
Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.62 062 W5-16 SPO-2F449: Grand Steel Pan(min.24 ga.)with Overlay Double-Car(9'2"up to
Harbor,Stone Manor 16'0"wide)WINDCODE@ W5 Garage Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FLIS279 RS C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant: N/A FL15279 R5 C CAC W5 Listing Intertek.pdf
Design Pressure: +30 PSF/-30 PSF Quality Assurance Contract Expiration Date
Other:The OPTIONAL glazing available for this product meets 05/21/2028
the wind load requirements of the building code but DOES NOT Installation Instructions
meet the impact resistant requirement for windborne debris FL15279 R5 II 103553-Rev06.pdf
regions.The product without glazing DOES comply with the Verified By: Intertek Testing Services NA,Inc.
impact resistant requirement for windborne debris regions(ref Created by Independent Third Party:
1609.1.4 FBC). Evaluation Reports
Created by Independent Third Party:
15279.63 063 W5-16 W-1B899: Reserve Reserve Wood Double-Car(9'2"To 16'0"wide)WINDCODE®
Collection RHxx W5 Garage Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes i�ection.pdf
Impact Resistant: N/A FL15279 R5 C CAC W5 Listing Intertek.pdf
Design Pressure: +30 PSF/-33.5 PSF Quality Assurance Contract Expiration Date
Other:The OPTIONAL glazing available for this product meets 05/21/2028
the wind load requirements of the building code but DOES NOT Installation Instructions
meet the impact resistant requirement for windborne debris FL15279 R5 II 102536-Rev06.pdf
regions.The product without glazing DOES comply with the Verified By: Intertek Testing Services NA,Inc.
impact resistant requirement for windborne debris regions(ref Created by Independent Third Party:
1609.1.4 FBC). Evaluation Reports
Created by Independent Third Party:
15279.64 064 W5-16-B AL-11`499: AvanteT" Full View Aluminum Residential WINDCODE@ W5 Sectional
Door, 12'3"to 16'2"wide
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FLIS279 RS C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspect on.pdf
Impact Resistant: N/A FL15279 R5 C CAC WS Listing Intertek.pdf
Design Pressure: +30 PSF/-30 PSF Quality Assurance Contract Expiration Date
Other:The OPTIONAL glazing available for this product meets 05/21/2028
the wind load requirements of the building code but DOES NOT Installation Instructions
meet the impact resistant requirement for windborne debris FL15279 RS II 103447-Rev04.pdf
regions.The product without glazing DOES comply with the Verified By: Intertek Testing Services NA,Inc.
impact resistant requirement for windborne debris regions(ref Created by Independent Third Party:
1609.1.4 FBC). Evaluation Reports
Created by Independent Third Party:
15279.65 065 W5-16-C AL-IF499: AvanteTM Full View Aluminum Residential WINDCODE®W5 Sectional
Door, 12'3"to 16'2"wide
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant: N/A FLIS279 R5 C CAC W5 Listing Intgrtek.pdf
Design Pressure:+32 PSF/-32 PSF Quality Assurance Contract Expiration Date
Other:The OPTIONAL glazing available for this product meets 05/21/2028
the wind load requirements of the building code but DOES NOT Installation instructions
https:/Avm.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZlQRAbbA5BZkl9lvxlwrUzbhrVbPy2N°/`2fxxjpA%3d%3d 2/6
12/16/2019 Florida Building Code Online
meet the impact resistant requirement for windborne debris FL15279 R5 II 103446-Rev04.pdf
regions.The product without glazing DOES comply with the Verified By: Intertek Testing Services NA,Inc.
impact resistant requirement for windborne debris regions(ref Created by Independent Third Party:
1609.1.4 FBC). Evaluation Reports
Created by Independent Third Party:
15279.66 066 W5-16-HY DSIE-IA171: 2050, 1-3/8" Double-skin Insulated EPS(exterior skin 27 ga, min.;
2051,2053,4050,4051,4053,62, interior skin 29 ga. min.) Double-Car(9'2"to 16'0"wide)
64,65,62G,62LG,64G,SDP38, WINDCODE®W5 Garage Door
SFL38,SRP38, 134, 135, 136,6130,
6131, 6133
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant: No FL15279 R5 C CAC WS Listinq Intertek.pdf
Design Pressure: +32 PSF/-32 PSF Quality Assurance Contract Expiration Date
Other:The standard glazing available for this product meets 05/21/2028
the wind load requirements of the building code but DOES NOT Installation Instructions
meet the impact resistant requirement for windborne debris FL15279 RS II 102185-13-Rev12.pdf
regions. Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
y Created by Independent Third Party:
15279.67 067 W5-16-HY DSIE-1A171: 2050, 1-3/8" Double-skin Insulated EPS(exterior skin 27 ga. min.;
2051, 2053,4050,4051,4053,62, interior skin 29 ga. min.) Double-Car(9'2"to 16'0"wide)
64,65,62G,62LG, 64G,SDP38, WINDCODE@ W5 Garage Door
SFL38,SRP38, 134,135, 136,6130,
6131,6133
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant:Yes FL15279 R5 C CAC W5 Listing Intertek.pdf
Design Pressure:+32 PSF/-32 PSF Quality Assurance Contract Expiration Date
Other:Solid doors(no glazing)are impact-resistant(large 05/21/2028
missile impact). Installation Instructions
FLIS279 R5 II 102185-A-Revl2.pdf
Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.68 068 W5-16-HY PAN-2F143: 84A,94, Steel Pan(min.24 ga.) Double-Car(9'2"to 16'0"wide)
14RST,4RSF,48,486 WINDCODE@ W5 Garage Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant:Yes FL15279 RS CAC W5 Listinq Intertek.pdf
Design Pressure: +34 PSF/-35 PSF Quality Assurance Contract Expiration Date
Other:Solid doors(no glazing)or doors with optional impact- 05/21/2028
resistant glazing are impact-resistant(large missile impact). Installation Instructions
FL15279 R5 II 101922-A-Rev11.pdf
Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.69 069 W5-16-HY PAN-2F153: 84A,94, Steel Pan(min. 25 ga.) Double-Car(97"to 16'0"wide)
73,75, 1500,190,4RST,4RSF, WINDCODE@ W5 Garage Door
6RST,6RSF,48,42,55,48B,42B,
55S
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 RS C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes I�ection.pdf
Impact Resistant:Yes FL15279 RS C CAC WS Listing Intertek.pdf
Design Pressure: +32 PSF/-32 PSF Quality Assurance Contract Expiration Date
Other:Solid doors(no glazing)or doors with optional impact- 05/21/2028
resistant glazing are impact-resistant(large missile impact). Installation Instructions
FL15279 R5 II 101922-A-Revll.pdf_
Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.70 070 W5-16-HY PAN-2F153: 84A,94, Steel Pan(min. 25 ga.) Double-Car(9'2"to 16'0"wide)
73,75, 1500, 190,4RST,4RSF, WINDCODE®W5 Garage Door .
611ST,6RSF,48,42,55,48B,42B,
55S
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 115 C CAC Letter with proof of contract and proof of
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZIQRAbbA5BZklglvxlwrUzbhrVbPy2N%2fxxjpA*/a3d°/a3d 3/6
12/16/2019 Florida Building Code Online
Approved for use outside HVHZ:Yes inspedion.pdf
Impact Resistant: No FL15279 R5 C CAC W5 Listing Intertek.pdf
Design Pressure: +32 PSF/-32 PSF Quality Assurance Contract Expiration Date
Other:The standard glazing available for this product meets 05/21/2028
the wind load requirements of the building code but DOES NOT Installation Instructions
meet the impact resistant requirement for windborne debris FL15279 R5 II 101922-B-Revll.pdf
regions. Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.71 071 W5-20 AL-1F499: Avante'" Full View Aluminum Residential WINDCODE®WS Sectional
Door, 16'3"to 20'2"wide
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant: N/A FL15279 R5 C CAC WS Listing Intgrtek.pdf
Design Pressure: +30 PSF/-30 PSF Quality Assurance Contract Expiration Date
Other:The OPTIONAL glazing available for this product meets 05/21/2028
the wind load requirements of the building code but DOES NOT Installation Instructions
meet the impact resistant requirement for windborne debris FL15279 R5 II 103448-Rev05.pdf
regions.The product without glazing DOES comply with the Verified By:Intertek Testing Services NA,Inc.
impact resistant requirement for windborne debris regions(ref Created by Independent Third Party:
1609.1.4 FBC). Evaluation Reports
Created by Independent Third Party:
15279.72 072 W6-09 DSIE-1A171: 2050, 1-3/8"Double-skin Insulated EPS(exterior skin 27 ga. min.;
2051,2053,4050,4051,4053,62, interior skin 29 ga. min.) Single-Car(up to 9'0"wide)
64,65,62G,62LG, 64G,SDP38, WINDCODEO W6 Garage Door
SFL38,SRP38, 134, 135, 136,6130,
6131,6133
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant: N/A FL15279 R5 C CAC W6 Listing Intertek.pdf
Design Pressure: +37 PSF/-37 PSF Quality Assurance Contract Expiration Date
Other:The OPTIONAL glazing available for this product meets 05/21/2028
the wind load requirements of the building code but DOES NOT Installation Instructions
meet the impact resistant requirement for windborne debris FL15279 R5 II 101654-Revl3.pdf
regions.The product without glazing DOES comply with the Verified By: Intertek Testing Services NA,Inc.
impact resistant requirement for windborne debris regions(ref Created by Independent Third Party:
1609.1.4 FBC). Evaluation Reports
Created by Independent Third Party:
15279.73 073 W6-09 DSIE-1F171: 4300,4301, 2"Double-skin Insulated EPS(exterior skin 27 ga. min.;
4310,4400,4401, HDG, HDGL, interior skin 27 ga. min.) Single-Car(up to 9'0"wide)
HDGF,66, 66G,67,67G,68,SP200, WINDCODE@ W6 Garage Door with Optional Impact-Resistant
SF200,SE200, 6200,6201,6203 Lites
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes ins ection.pdf
Impact Resistant:Yes FL15279 R5 C CAC W6 Listing Intertek.pdf
Design Pressure: +37 PSF/-40 PSF Quality Assurance Contract Expiration Date
Other:Solid doors(no glazing)or doors with optional impact- 05/21/2028
resistant glazing are impact-resistant(large missile impact). Installation Instructions
FL15279 R5 II 101526-A-Revl6.pdf
Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.74 074 W6-09 DSIE-1F171: 4300,4301, 2"Double-skin Insulated EPS(exterior skin 27 ga. min.;
4310,4400,4401,HDG, HDGL, interior skin 27 ga. min.)Single-Car(up to 9'0"wide)
HDGF,66, 66G, 67,67G,68,SP200, WINDCODE@ W6 Garage Door
SF200,SE200,6200,6201,6203
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.Ddf
Impact Resistant: No FL15279 R5 C CAC W6 Listing Intertek.pdf
Design Pressure: +37 PSF/-40 PSF Quality Assurance Contract Expiration Date
Other:The standard glazing available for this product meets 05/21/2028
the wind load requirements of the building code but DOES NOT Installation Instructions
meet the impact resistant requirement for windborne debris FL15279 R5 II 101526-B-Rev16.pdf
regions. Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.75 075 W6-09 DSIE-1F471: GD2SP, Gallery/Artistry/Expressions: 2"Double-skin Insulated EPS
GR2SP,GD2LP,GR2LP,AR2SP, (exterior skin 27 ga. min.; interior skin 27 ga. min.)Single-Car
https:/Avww.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZIQRAbbA5BZkl9lvxlwrUzbhrVbPy2N%2fxxjpA%3d%3d 4/6
12/16/2019 Florida Building Code Online
AR2LP, ED2SP, ED2LP (up to 9'0"wide)WINDCODE@ W6 Garage Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes insection.pdf
Impact Resistant:Yes FL15279 R5 C CAC W6 Listinq Intertek.pdf
Design Pressure:+38 PSF/-42 PSF Quality Assurance Contract Expiration Date
Other:Solid doors(no standard glazing)are impact-resistant 05/21/2028
(large missile impact). Installation Instructions
FL15279 R5 II 103954-A-Rev03.pdf
Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.76 076 W6-09 DSIE-1F471: GD2SP, Gallery/Artistry/Expressions: 2"Double-skin Insulated EPS
GR2SP,GD2LP, GR2LP,AR2SP, (exterior skin 27 ga. min.; interior skin 27 ga. min.)Single-Car
AR2LP, ED2SP, ED2LP (up to 9'0"wide)WINDCODE®W6 Garage Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant: No FL15279 R5 C CAC W6 Listing Intertek.pdf
Design Pressure: +38 PSF/-42 PSF Quality Assurance Contract Expiration Date
Other:The standard glazing available for this product meets 05/21/2028
the wind load requirements of the building code but DOES NOT Installation Instructions
meet the impact resistant requirement for windborne debris FL15279 R5 II 103954-B-Rev03.pdf
regions. Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.77 077 W6-09 DSIEO-1M479: Double Skin Insulated EPS(exterior skin 27 ga. min.; interior
Coachman/Settlers/Affinity skin 27ga. min.)with Overlay Single-Car(up to 9'0"wide)
WINDCODE@ W6 Garage Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes inspection.pdf
Impact Resistant:Yes FL15279 R5 C CAC W6 ListingIntertek.pdf
Design Pressure:+38 PSF/-42 PSF Quality Assurance Contract Expiration Date
Other:Solid doors(no standard glazing)are impact-resistant 05/21/2028
(large missile impact). Installation Instructions
FL15279 115 II 103223-A-Revll.pdf
Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.78 078 W6-09 DSIEO-1M479: Double Skin Insulated EPS(exterior skin 27 ga. min.; interior
Coachman/Settlers/Affinity skin 27ga, min.)with Overlay Single-Car(up to 9'0"wide)
WINDCODE@ W6 Garage Door
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes ins ection.pdf
Impact Resistant: No FL15279 R5 C CAC W6 Listing Intertek.pdf
Design Pressure: +38 PSF/-42 PSF Quality Assurance Contract Expiration Date
Other:The standard glazing available for this product meets 05/21/2028
the wind load requirements of the building code but DOES NOT Installation Instructions
meet the impact resistant requirement for windborne debris FL15279 R5 II 103223-B-Revll.pdf
regions. Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
15279.79 079 W6-09 DSIU-1A171: 9130, Double-skin Insulated PUR(exterior skin 27 ga, min.; interior
9131,9133,HDP13,HDPF13, skin 27 ga. min.)Single-Car(up to 9'0"wide)WINDCODE@ W6
HDPL13,7130,7131,7133,8130, Garage Door
8131,8133
Limits of Use Certification Agency Certificate.
Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes insoection.odf
Impact Resistant: N/A FL15279 R5 C CAC W6 Listinq Intertek.pdf
Design Pressure:+37 PSF/-37 PSF Quality Assurance Contract Expiration Date
Other:The OPTIONAL standard glazing available for this 05/21/2028
product meets the wind load requirements of the building code Installation Instructions
but DOES NOT meet the impact resistant requirement for FL15279 R5 II 104180-RevOl.pdf
windborne debris regions.The product without standard glazing Verified By: Intertek Testing Services NA,Inc.
DOES comply with the impact resistant requirement for Created by Independent Third Party:
windborne debris regions(ref 1609.1.4 FBC). Evaluation Reports
Created by Independent Third Party:
15279.80 1080 W6-09 DSIU-1F171: 9200, Double-skin Insulated PUR(exterior skin 27 ga, min.; interior
https://www.floridabuilding.org/pr/pr_app_dtI.aspx?param=wGEVXQwtDgv3yVVKJZ1QRAbbA5BZkl9lvxlwrUzbhrVbPy2N%2fxxjpA%3d%3d 5/6
12/16/2019 Florida Building Code Online
9201,9203,HDP20,HDPF20, skin 27 ga. min.)Single-Car(up to 9'0"wide)WINDCODE@ W6
HDPL20,7200,7201,7203,8200, Garage Door with Optional Impact-Resistant Lites
8201,8203
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL15279 R5 C CAC Letter with proof of contract and proof of
Approved for use outside HVHZ:Yes insigggion.pdf
Impact Resistant:Yes FLIS279 R5 C CAC W6 Listing Intgrtek.pdf
Design Pressure:+37 PSF/-40 PSF Quality Assurance Contract Expiration Date
Other:Solid doors(no standard glazing)or doors with 05/21/2028
optional impact-resistant standard glazing are Impact-resistant Installation Instructions
(large missile impact). FL15279 R5 II 104184-A-Rev0l.pdf
Verified By: Intertek Testing Services NA,Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
Go to Page _ Page 4/8�.
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1624
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privagy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
® W.9 F91A9 M
Credit Card
Safe
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yWKJZlQRAbbA5BZkl91vxlwrUzbhrVbPy2N%2fxxjpA%3d%3d 6/6
Imi v a Wm v G rLm v Y 1DIO D=HEIGHT I ff U-BARS THE OPTIONAL GADO SHOWN ON 7HS DRAWING MEET+'THE END REV DATE IES[ABTI[N
SECNIINS WIND LOAD REOUIREME?TS OF THE FLORIDA BUMDIND CODE
UP T13 7101 4 OR INTERNATIONAL OLIUM CODE BUT DOES EM MEET IHE STILE 07 09/2005 ADDED ROLLER OPTION
DD+W bm� I'm� 4m.— 7•B'70 e's' S 0 NPALT RMSTAHF REQUIREMENT FOR WINDBORNE DEBRIS INTER.
r0' 1 A•e• B 111 REGIONS REF.CHAPTER fe FM/MCI
BD c STILE 08 11/30/07 COMBINED CLOPAY, HOMLES, & IDEAL M N
IUAo v'Au1rE6A a"' M•say f112 lar TO tri• 7 14 7IOS DOOR Ems OR EXCEEDS THE oma+LOADS FOR THE 09 10/21/08 ADDED M/N 62G AND 64G,ADDED MPC
Erb•70 tar R 16 ULIU E WHO SPENDS ISTD BELOW AeatmOm TO 7HE FUNODA OUTSIDE
a"I
mm ' w ""'1s4 u'2'TO 15.9' 9 19 WILLING CODE OR THE NTINOONIL MUM CODE(BASED ON HANDLE 10 12/13/10 ADDED IMPACT-RESISTANT CONSTRUCTION NOTE.
ASCIET-10)FOR THE IMIDWINO CONDITION&1)ENCLOSED
Iso• H) M DWI LWA 2)DOOR HO r OF WIDTH N BUIDNG'S END ZONE. 11 1/26/11 AOOm UPDATED MODEL NUMBERS.
NAx sEcrmN
HEIGHT.
el• ANT ROOF SID'AND
4)TESTING N AaIOlDaCE WITH LOCK BAR 12 01/31/12 REVISED WIND SPEED TABLE FOR A.SCE7-10.
9199 tos DTTF DgMOWC CYDYATIOI9 Br A D9BiIE0 ENGAGES IN
PIIOIML wY I2NTER. 8'THICK
TRACK ON
a7au1E vum OUTSIDE KEYED LOCK EACH SIDE
OPTIONAL S A ACRYLIC OR OSB ®OM He 145 1:D ISO En LACK BAR LOCKING 1-3 —I
GLASS LRES AVAILABLE OPTIONAL SFOF DOOR. /
ACRYLIC GLAZING IS PLASKOLRE OPRX CATEGORYDMSLIRE
>t,c,n n,c,a W,c s,c W
OR LUCITE CP APPROVED CC2 PLASTIC SLIDE BOLT
B IN ACCORDANCE WITH IBC/FBC 26%B WAN ROD'HEIDT B5' t9 a' u• 5r END LOCK ENGAGES 12 GA. GALV.STEEL TOP ROLLER BRACKET.
r SEE SECTION B-B a , STILE INTO VERTICAL SHEET MAAKEr TrAC ED WITH (4) 114.5/8-
TRACK I
14x5/8'TRACK. ONE
LOCK ON
EACH SIDE
$4 2A OF DOOR.
o IENGAGESINSIDE SUDE BOLT
SNAP LATCH CK. LOCK OPTION
ONTO VERTICAL TRACK.
9 ONE SNAP LATCH ON 1 POUND DENSITY
LYST
EACH SIDE OF DOOR. EXPANDED POLYSTYRENE
27 GA.STEEL MIN. EXTERIOR FOAM INSULATION LAMINATED
INTER.STILE SKIN WITH A INTERIOR SKEIINES. AND
BAKED-OD-O N PRIMER AND
_ POLYESTER PAINTED TOP COAT.
OUTSIDE KEYED ENO
HANDLE STILE TONGUE AND GROOVE JOINTS. END HINGE EACH 14 GA. GALV. STEFl.
FA5TI7JED TO END STILES W/(4)
X INSIDE HANDLE 14x5/8'& (4) 1/4'x3/4'SEF SHEET
LOCK POSITION pUT510E KEYED LOCK ETAL SCREWS TAPPING SCREWS.114x5/8'SHEET
(BOTH SIOFS) SNAP LATCH LOCK OPTION METAL SCREWS 3'TALL x 20 GA.GALV.STEEL.U-BAR.
I WITH
K51 YIN.TWO PER SECTION.ATTACHED
L 7W0 3'TALL x 20 GA. GNLV. WfIH 7W0 1/4'x34'SELF TAPPING
(OPTIONAL OUTSIDE KEYED LOCK POSITION J STEEL U-BARS PER SECTION. SCREWS PER HINGE LOCATION.
A*"-" BD KSI MIN. 1/4'x3/4'SELF 29 GA. STEEL MIN. INTERIOR GALV.
INSIDE ELEVATION—MAX. DOOR WIDTH - 18'-0' O TAPPING SCREWS D AND ABABAKED ONmPOLYYES PRIMER
TOP COAT.
'[INSTALLER (TOBYSUITDOOR
(SHORT PANEL SHOWN) 13 GA GALV. STEEL BOTTOM
vmrx•� TA1ra arAnaExr NWum Wnur ar 2x6 YELLOW PINE JAMB 20 GA.MIN.GALV.STEEL END STILE 14 GA. END HINGES 18 GTL. INTERMEDIATE HINGE 01x5/8'SHEET MET WITH (2)
S d'LAO SCREWS ON 24'CENTERS.1-1/p O.D. VIEW B
WASLIEIE RBOUNm.LAD SCREWS MAY BE CaONLBtSUNK
VIEW C SCREWS.
((RBU0EN Tar REouwEv)ro PRovInE A FlJ15H MOUNTING ALUMINUM EXTRUSION
SURFME HORQOMAL.Wes DO NONTRANSFER LOAD. 12 G4 GALV. STET.TRACK &VINYL WFJRHf715TRIP.
0 � BRACKET FASTENED TO WOOD SECTION A-A
uN.raFroEr,-reL,x,r,D- JAMB WITH ONE 5/18'x1-5/8'
z/e13'SLEEVE A40M=39 ON 14'MUM(2,000 WOOD LAG SCREW PER BRACKET. TxD mFwww AADWTCGoa voWo
P9 Mw.coNaaTE).WASFFIS Na11aD xlnR StEfVE 7/11)'I.D. ROUND FA GA MIN. GCEN STEEL INTER. HINGE _
U EACH
TO CENTER STILE L SC ULLHORZDKD�DOG"Tari axra etMar ne�a Dao eaw vTIB Toa. DOOR
Nmum
A�la 2'GALV. K BR TRACK P SHN E FROLLER). EACH 114x5/8'SHEET METAL SCREWS. IxIOe IsrAI1B1 DO wO
1/413'TTPCON SUMS ON 127 CENTERS(2.000 PSI FASTENED TO TRACK BRACKETS. (ONE PER ROLLER). DOas MER If Tui e'tLt DOaits AND 11t"ERR
1@L�p MOR Y cEHLEAs(o-9a BIDCK).f'O.D. EACH BRACKET ATTACHED WITH ONE
wA4RF7S REDTNWITH TAPCONS 1/4'x5/8'BOLT&NUT 9$ 14 GA GALV. STEEL ROLIEE7 HI GE is Dt oALv.sTNa FtAO elAa¢r.
) 7W0 1/4'RIVETS. FASTENED TO END STILLS W/ EACH (�ejte�°-0/e tEACH
atv SIM�a"�
ANCHORS AWHUSFI Y NK NSE FWfaQROHN�JIL� JAMB CONFIGURATION 14x5/8'SHEET METAL.SCERF AND r DAM SIM TWACK (Nate 1-0�WOOD IAO SCREI&
PROVIDE DO Tar mAtawn LOAD.
4) 1/4'x3/4'SELF TAPPING SCREWS. TM+�O4cD®aeD'ICL
•REFER 70 txvu TDs-f e1. ' 10 BALL SHORT STEM STEEL ROLLER NIi.D 2-1 ti12 DL aEv 7wac OW4W.
e TFW"=euaers rtx 10'
A 1tcNRsm DF.swN PRGFFSSIORUL MAY ALSO BE WITH STEEL OR NYLON TIRE. BETWEERITSRARpSIDE UP
T=a iEal,N IxIOR
[OEPLIIRED la APPROVE AL7FJ6EA7E FASTENERS AND/OR NOf TO Da�ID]D'ODT
JAMB CONFW77RA7PDW,
T � t. E Y aLV.SIEELL TRILTL
NPACN=STANN ASSE_Y DEEMS STAN04TD ASSETIBLY DEEMS t.' t1K 7RAd TDILaO1Rs.OeD'
DMWIND tOEteS.a ow m As Tozleo.w
SECTION B-B ENON-IYPACN RESISTANT CIA2IN0 aPUDNI ORIOWL DMWWOS AE 901ED!I BLUE 7 -FOR DDaD al Dy IIP.2-1/2112 fA GLLV.2mm TRAIX wVORT.
N(WON A RAM SEAL lwmOB9} � l2 OONFVJV�g�NDT � (4)��S f4J1 SDE
"(COED M "SPAOIO
PICA=CDR=la 1 1/r FOR M= F�
IMPACT-RFSISrAN4r CONSTRUCTION: �� •W'
SOLA DODRS NO GIAZ1N01 A!E TIRADE-A6ISNANr.TFE
OEM Daae r B7STALLID w aBa'uANCE Wtn( ESIGN LOADS: +32.0 PSF do-32.0 PSF
MWS SECTION MEETS THE WIND TEST LOADS: +48.0 PSF&-48.0 PSF
THE FIORDA BIIIDNO CODE AND DEfammoN4. OPTIONAL DSB OR 1 e'ACYROC LUES AVNUBIE
BU LIKHO CODE ALL3)®a IRE WAON-RESISTANT VDaLMO IN77NG NAIL Det S�
HEn�m+1s RF.cHunRn 1e tec aPnaEw Aamtc No Is PIAKaIIE oPIIX OR MPC(DSIE-HAITI 16'W x 16'H
UITI a'APP. CC2 PLASTIC O ABODE
Wm1 C 2BD<.S C opay �� 4,20,2000 w5
THE' DOOR •NSNAl1ID w CaYRRANCE
NTLI THIS SECTION MEETS THE WIND LOAD
REOueE»rTNNrs of THE NDRIDA BUILDING CODE OR 65115 DUKE BLVD. 2050/4050/4053, 16'W, f32PSF
RNIFANAIONEU.NUl1MN0 COOT BUN YEkT IGD ENGINEER:#8 MILK WES�ETT'-P.E Building Products MASON,ON 45040 ORAVN 3" MWW
THE WPAOr kloUWL NT REVONFLERT DBORNE FLORIDA P.E 149496. (513)770-4600 ORAVD1f EAIa[7c VE1b
DEBRIS REMS REF.CHAPTER 1e FBC NOITEP.P.E.197613 CORD On CFECIIED ELY DC
a.M CoTaretim M RgWt.R. & B 102165 - A/B
O D p p FRUDUCT
p D D D O p o
,
, .
`
mtertek Testing Services NA,Inc. Tel+1-608-836-4400
N� 0te� te k mumv�h o�e m�+�o��ae�7�� mm Middleton,WI 52562 vmww'/mertek.mm
Total Quality.Assured.
Issue Date:October 4` 2O17 Letter Report No: 10324267W4|D-001a
Mr.Scott Hamilton, P.E.
OmpayBuilding Products Company Em/ai|:shammikon@dopaycorn
QSOSDuke boulevard
Mason,OH4S040
Sybiect: Intertek Listings that support FL 15279 for compliance with the Sixth Edition of the Florida Building
Code(2017)
Dear Mr.Hamilton,
This|etternepresentstheresu|tsofintartek'srevewmfthe|ntertekLbtn8sthatcurrentlysupport[1opay
FL15279product approval.
|ntertekaffirms that the|nterteh Listed products included in Florida Product Approval FL 15279 maintains
compliance with the Sixth Edition ofthe Florida Building Code (3Ol7).
Intertek has verified that the referenced certification documents are currently under surveillance services with
|ntertehfor the Florida Building Code. Attached isthe current Certification Agreement between |ntertekand
Clopay Building Products. This agreement also may be referenced as a QA contract that bears no expiration
date and as such does not expire except upon it's termination and is valid indefinitely.
Sincerely,
UNTERTGK TESTING SERVICES NA,INC.
Reported by: Reviewed by:
John Schachtner ~ |Kooner, P.En8'
Project Engineer-Evaluation Services Oirector—Ena|uabonSenviceu
Inmertek Inmermek mterteu
This report is for the exclusive use of InterleWs Client and Is provided pursuant to the agreement between Intertek and its Client Intertelft responsibility and liability
are limited to the terms and conditions of the agreement Intertek assumes no liability to any parly�other than to the Client In accordance with the agreement,for any
loss,expense or damage occasioned by the use of this report.Only the Client is authorized to permit copying or distribution of this report and then only in its entirely.
Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,product or service must fast he approved In writing by Intertek.
The observations and test results in this report are relevant only the sample tested. This report by itself does not Imply that the material,product or service is or has
ever been under an Intertek certification program.
Version:O2August IO17 Page 1of1 SFT-BC-OP-19b 0.
8431 Murphy Drive
Middleton,Wl 53562
Intertek
Telephone: +1 608 836 4400
L
Facsimile: +1608 8319279'
www.Intertelcoom
MMUFACTUREWS CERTIFICATION AGREEMENT
THIS AGREEMENT made the 12th day ofrua between INTERTEK
_Egk—_M,2010, by and
TESTING SERVICES NA INC.having offices at 8431 Murphy Drive,Middleton,WI USA(nintertek!')and
Clopay Building products Company,Inc. having offices at
(Manufacturer Company Name)
1400 W.Market Street,Tr6y,OH 46373 USA {"Client").
(Manufacturer Company Address including Country)
RECITALS
Intertek provides a service for evaluating whether products provided by the Manufacturer comply
with designated standards or specified requirements, Subject to the terms of this Certification Agreement,
Products found to be in compliance by Intertek may be eligible for inclusion on a list maintained by Intertek
for Products to display a Certification Mark owned by Intertek.
Another party (the "Client") desires to submit or has submitted to Intertek certain devices,
equipment, materials, or systems manufactured by the Manufacturer for the Client for evaluation in order
that the product may be considered for Listing and Labeling by Intertek.
If the submitted product is found to be eligible for Listing, Labeling, and Follow-up Service, this
Certification Agreement shall be executed by Intertek and the Manufacturer setting forth the terms and
conditions to which the parties hereto must adhere.
NOW THEREFORE, for and in consideration of the mutual covenants herein expressed and other
lawful and valuable consideration,the parties hereto agree as follows-,
1 DEFINITIONS
1.1 Authorization to Mark.The term Authorization to Mark ("AW) shall mean a written
document from Intertek that authorizes the Client and/or Clients Manufacturer to apply an Intertek
certification mark to a specific product.
1.2 Certification Mark. The term Certification Mark("Mark")shall refer to any common law or
registered trademark owned by Intertek,or its affiliates,used in the certification of Product
1.3 Follow-up Service. The term Follow-up Service shall refer to the process of monitoring
the Manufacturer's compliance with the Intertek Requirements.
1.4 Intertek Requirements. The term Intertek Requirements shall mean(a)the requirements
contained in the Listing Report, (b) the standard(s), if any, applicable to the Product (c) the terms of this
Certification Agreement and(d)any requirements separately applied as a condition of the Listing.
1.6 Labeling. The term Labeling shall refer to the process of applying the Mark to the Product,
whether the Mark is applied to the Product by a separable label, directly on the product, or by other media
as authorized by Intertek.
1.6 Listing. The term Listing shall mean the process of preparing and including the Product in
the published directory of Intertek certified products.
Jo�
<@>
VvTS/mm 11109109 8D 16.3.40(1119/09)Mand ftWek Intertek Intertek Intertek Intertek Intertek
1.7 Listing Report, The term Listing Report shall mean the document prepared by Intertek,
also known as Factory Audit Manuel(FAM),which identifies the Client,the Manufacturer and the Product,
and specifies Intertek Requirements for the Product including the type and form of Mark which must be
used on or in connection with the Product and related Information.
1.8 product The term Product("Product') shall mean a Clienrs device, equipment, material,
or system manufactured by the Manufacturer,that has been submitted for testing or evaluation,found to be
in compliance with Intertek Requirements and approved for Listing.
2. CERTIFICATION
2.1 Work Authorization, Except to the extent Intertek shall reasonably deem necessary in
order-to.respond to an allegation that a cedlfi@_d Product in the marketplace Is non-compliant or in the
ordinary course of follow up service
that are required for continued listing, Intertek shall not
perform any services under this 6greement unless and until authorized byClient pursuant to a propose
pertaining to a particular Product that contains a scope'of work, pricing and other terms agreed by the
oartles, and signed by an authorized representative of each party
22 Testing and Evaluation. Intertek Is an independent laboratory providing testing and
evaluation services to determine whether representative samples of a Product comply with designated
national and international standards, specifications, and/or codes. Intertek does not publish standards,
specifications, and/or codes, and, therefore, does not warrant to the Client or the Manufactfirer that the
standard used for the evaluation is adequate. The Client and the Manufacturer understand and agree that
Intertek has only tested or evaluated the submitted Product samples and does not guarantee or warrant the
quality or compliance of all units of the Product manufactured or produced by the Manufacturer. The
Manufacturer further acknowledges that as an independent laboratory, Intertek assumes no responsibility
for the production of the Product.
7-3 Client Obligations. The Manufacturer understands Its obligailons pursuant to this
Certification Agreement In order to maintain eligibility for Listing, and warrant's that it shall comply with the
following provisions:
(a) The Manufacturer agrees that If the Client or Manufacturer wishes to modify or change the
Product such that the Product no longer meets the requirements of the Listing Report for the
Product the dient or Manufactdrer must first either obtain the approval of Intertek or
discontinue use of the Mark. The Product may no longer be eligible for Listing if it has been
modified or changed by the Client or Manufacturer after InterteWs testing or evaluation,
(b) Upon request the Manufacturer agrees that it shall retain or make sample a available of the
a
certified product from the most current production.
(c) The Manufacturer agrees to notify Intertek in writing of any reports that it receives of serious
personal Injury or property damage Involving the Product.
(d) The Manufacturer shall notify intertek of any labeled Product which has left the control of the
Manufacturer that does not comply with Intertek Requirements.
(e) The Manufacturer warrants that a quality control program is, or will be, established and
maintained to ensure Product compliance with the Intertek Requirements.
2.4 Reservation of Rights. Intertek reserves the right,upon reasonable written notice to the
Client,to re-evaluate the Product at the Clients expense. This re-evalubtion may be the result of Follow-up
Service,a revision ofthe applicable standard, new information regarding the characteristics of the material
used in the Product,or other information that raises a question concerning the conformance of the Product
to Intertek Requirements.
2.5 Revision or Withdrawal of the Intertek Requirements. Intertek reserves the right upon
reasonable notice to the Client, to revise or withdrew the Intertek Requirements. If the Intertek
Requirements are revised, the Client and the Manufacturer shall be entitled to continue Listing and
Labeling of the Product upon a demonstration to the satisfaction of Intertek that the Product compries with
the revised Intertek Requirements. If the Intertek Requirements are withdrawn, the Clients and the
Manufacturer's right to the Listing and Labeling of the Product shall terminate pursuant to the terms of
WTS/mm 11109/09 Page 2 of 5 SD 16.$Ae(1119109)Mandatory
Article 6 of this Certification Agreement In the case of a revision or withdrawal of Intertek Requirements,
Intertek shall provide a notice specifying a date by which the Product'must meet the revised Intertek
Requirements or for such termination.
3. LISTING AND LABELING
3.1 Ownership of the Mark. Ownership of the Mark and all trademark rights In the Mark
remain in Intertek, even if it Is used on the Product. The Mark shall only be applied to a Product that
complies With the Intertek Requirements and such Mark shall be applied as specified In.the Listing Report.
The Mark may be applied only to those models and brands that are specificiilly named In the Listing Report
at the factory receiving active Follow-up Service and as noted on the Authorization to Mark. Except as
provided herein and as indicated in Article 3.2, any other use of the Mark, or the lntert�k name, on the
Product is wcVressly prohibited.
3.2 Follow up Service. As a part of the Listing and Labeling of the Product,the Manufacturer
shall cooperate with the Intertek representatives who conduct Follow-up Service. Follow-up Service may
include factory audits at any time during business houri and such Intertek representatives shall have free,
unannounced, and immediate access to the Manufacturer's premises wherein the Product or components
thereof, may be fabricated, processed, finished, stored, or located. Intertek-representatives shall comply
with factory policies as required while on premises. Follow-up Service Is intended to allow Intertek to
monitor the Manufacturer's compliance with maintaining continuing conformity of the Product to the Intertek
Requirements, and to control the use of Intertek's Marks.The fia'atory audits are not intended to satisfy or
otherwise replace Manufacturer's responsibility to maintain its quality'control program and to ensure that
the Product remains in the compliance with the Intertek Requirements, Follow-up Service may also include
Manufacturer questionnalre,13, and/or the Manufacturer's warranty of conformity. Intertek has the right to
perform'a final factory inspection to record final production status and to recover all unused Intertek
Certification Marks upon notification of termination of th6 Authorization to Mark. Fees for a final inspection
will be Willed in accordance With Article 7.3 of this Certification Agreement.
4. INDEMNIFICATION AND LIABILITY
4.1 Indemnification. The Manufacturer agrees to hold Intertek harmless and to defend and
Indemnify Intertek against any liability,-loss,or damage from claims,demands, costs(including legal fees),
or judgments arising out of any negligent or intentional acts of the Manufacturer relating to the Product or
arising from the use of the Mark.
4.2 Liability. Intertek will not under any circumstances, be liable to the Manufacturer for any
indirect, special, punitive, or consequential damages, or any third party claims which may arise as a result
of the services provided in this Certification Agreement
6. FA16ge To commy wrrH INTERTEK REQUIREMENTS
6.1 Remedial Action. In the event that Interiek detects any deviation or variance in the
Product from Intertek Requirements,or Improper or unauthorized use of the Mark or Intertek name, upon
written notice to the Client Intertek reserves the right in Its sole discretion,to take such action as it deems
necessary,including but not limitdd to:
(a) Requiring the Client, at its own expense, to undertake corrective action to ensure that the
Product complies with Intertek requirements,
(b) Suspension or revocation of the Listing and the right to label the Product
(a) Withdrawal of the supply of labels and removal of the Mark from non-conforming products;
(d) Removal of the Product from the Intertek Directory of Listed Products;
-(e) Termination of this Certification Agreement pursuant to Article 6;
VVTS/mm 1'1109109 Page 3 of 5 SD 16,3.4o(11/9M)Mandatory
Notification of regulatory authorities and the public;
(9) Compliance with any applicable statutes,rules,or regulations,
6.2 Injunctive Relief. The Manufacturer acknowledges that the manufacture, sale, delivery,
shipment,distribution,or promotion of the Product utilizing a Mark w6uld mislead or endanger the public if
such Product is not eligible to use the Mark or does not comply with v the Intertek Requirements.- The
Manufacturer further acknowledges that a breach of this Certification Agreement can not be adequately
compensated by money damages. The ManActurer agrees that in the event of a breach of'the
Certification Agreement Intertek shall have the right to obtain a temporary restraining order without prior
notice to the Manufacturer, together with an action for a preliminary and permanent injunction, and such
other and further relief as may be provided by law, Said injunction shall prohibit the Manufacturer from
further use of the Mark and shall require the Manufacturer to comply With the provisions in Article 6.3 of this
Certification Agreement
6.3 Suspension. Up6n a Clients or a Manufacturer's failure to comply with any of the
requirements of this Certification Agreement or Listing Report, Intertek may issue a letter of suspension
which shall no*the Client of the nature of the failure and the period of suspension of the Clients right of
Labeling. In the event that the Client falls to take corrective action to resolve the cause of suspension,this
Certification Agreement shall be terminated'pursuant to Article 6.
6.4 Public Notice. In the event that Intertek has confirmed evideh ce that the.Product
duct in the
marketplace has a significant non-conformity, Intertek will contact the Client and act in support-of remedial
steps taken by the Client to address the non-conformity, Including, if necessary, public notification and/or a
product recall undertaken by the Client. In the event-that the Client does not take action to address a
significant non-conformity related to the Product, Intertek reserves the right lo contact appropriate
government agencies,other parties In the supply chain and/or issue public notifications advising of the non-
conformity pursuant to Article 6.1(Q above.
6. TERMINATION OF THE AGREEMENT
6.1 Termination By Either Party. Either -party may, for any reason, terminate this
Certification Agreement, as to any Product, upon not less than sixty (60) days written notice to the other
party. Suchnotice shall designate a termination date and the notice period-shall be deemed to commence
upon.the date of mailing of the notice to the other party by registered or certified mail, return receipt
requested or by courier with confirmed delivery.
► 6.2 Intertek Right To Terminate. Intertek may terminate this Certification Agreement as to
any Product, without prejudice to any other rights or remedies that Intertek may have, upon either of the
following:
(a) Immediately upon written notice, If Intertek determines that the Product falls to comply with
the Intertek.Requirements or the Client is in default pursuant to Article 7.3;
(b) Thirty (30) days after the Client receives written notice in the event of (i) the filing of a
voluntary or involuntary petition In bankruptcy, (il) the making of any arrangement or
composition with creditors by the Client (111)the appointment of a receiver for the Client,
or(iv)the voluntary or involuntary liquidation of the business of the Client
6.3 Obligations Upon Termination. Upon termination of this Certification Agreement the
Client and the Manufacturer shall:
(a) Discontinue the use of the Mark on the Product or Clients promotional material or
advertising.
(b) Promptly return to Intertek all Marks, Labeling material,and the Listing Report and warrant
in writing the date of last use of the Mark.
VVTS1mm 11109/09 Page 4 of 5 80 16.$,4e(I V9/09)Mandatory
FEW
(c) Continue to honor the terms of Article 4: of this Certification Agreement concerning
indemnification and liability,which terms shall survive the termination of this Certification
Agreement.
(d) Pay any remaining outstanding charges owing to Intertek.
7. ADMINISTRA-WE PBgYLSIONS
7.1 Confidentiality. Without written authorization from the Manufacturer, Intertek will not
voluntarily disclose to third parties confidential and proprietary information which the Manufacturer provides
to Intertek This obligation shall not'apply to Information which Is already available to the public, or
acquired from other sources without confidentiality restrictions,or Is required to be disclosed by Intertek to
Regulatory Authorities responsible for the acceptance of the Product Intertek agrees that this obligation to
maintain confidentiality shall survive the termination of this Certification Agreement.
7.2 Subpoena. If Intertek Is served with a Subpoena, Court Order, or similar document
requesting the disclosure of confidential or proprietary information supplied to Intertek by the Manufacturer,
Intertek shall promptly notify the Manufacturer. In the event that the Manufacturer chooses to contest the
request, Intertek shall cooperate with the Manufacturer. The responsibility for contesting the request shall
rest sot*with the Manufacturer. If the Manufacturer declines to contest the request or Is not successful in
contesting the request Intertek will provide the requested information. Any costs incurred by Interlek In
responding to the request Including reasonable attorney's fees, shall be reimbursed by the Manufacturer
Immediately upon invoicing by Intertek.
7.3 Fees. Certification fees for maintaining the Listing,conducting the Follow-up Service,and
licensing of the Certification Mark will be prepaid or billed to the Client or a designated payor. Payment
shall be due upon presentation of Invoices and the Client shall be considered in default If the charges are
not paid within thirty(30)days, Certification fees are non-refundable.
7.4. No Assignment. The rights running to the Manufacturer under this Certification
Agreement may not be assigned to or acquired by any other person or corporation without Intertek's written
authorization.
7.6 Tenn. This Certification Agreement shall continue In effect for a period of one year from
the date first above written and shall automatically be renewed thereafter for periods of one year, unless
the termination rights provided for In this Certification Agreement are exercised,
7.6 Jurisdiction. This Certification Agreement shall be interpreted in accordance with and
governed by the laws of the Jurisdiction within which the Intertek office stated in the opening'paragraph is
located.
Intertek Test g rvlces NA Inc. Accepted By:C!2pay Building Products Company,Inc.
pany Name)
By. By:
(Signature o Intertek Individual) (Proprietor,Penner air rued Officer-Signature)
By. Sob Davison BY: )VIq
(Name of Authorized Individual-Printed)
Title: 01tregor dVMI Cord A&�'IVF V11V
Certification Title' V I eA
Date Signed:
Date Signed: 2-/Z,
WTS/mm 11/09/09 Page 5 of 5 8D 16.3.4e 011.9/09)mandatory
Report prepared for:Scott Hamilton(Clopay Building Products Co.,Inc.(CBPC))on 5/29/2014 10:56:59 AM Q
—'�PecDRECT POWEIREDBY
rim
-1e;k
L -A
LISTING INFORMATION OF Clopay WINDCODE@ W5 Sectional Doors
SPEC ID' 32639
Clopay Building Products Co., Inc. (CBPC)
8585 Duke Blvd.
Mason, ON 45040
This report is for the exclusive use of InterteWs Client and is provided pursuant to the agreement between'Intertek and its Client.
Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,
other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this report.Only
the Client is authorized to permit copying or distribution of this report and then only in its entirety.Any use of the Intertek name or one
of its marks for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek.The
observations and test results in this report are relevant only to the sample tested.This report by itself does not imply that the material,
product,or service is or has ever been under an Intertek certification program.
Clopay Building Products Co.,Inc.(CBPC)132639 1 Rev:Oct 16 2013 12:5 IPM I Uncontrolled Copy Page I of 4
Report prepared for:Scott Hamilton(Clopay Building Products Co.,Inc.(CBPC))on 5/29/2014 10:56:59 AMS r. POWEREDBYM
WIND RESISTANT DOORS
Clopay WINDCODE@ W5 Sectional Doors
Clopay WINDCODE@ W5 Sectional J
Doors
Impact Max. Design Design
Rating Width Pressure Pressure
Pos. Neg.
Single Car Double Skin EPS N/A +30 PSF -32 PSF
lGallery/Artistry/ Expressions
ISingle Car Double Skin EPS with Overlay N/A +33 PSF -37 PSF
Single Car Double Skin PUR N/A 9,-0tf +30 PSF -32 PS
jSingle Car Double Skin PUR with 91-0.1
N/A 0.1 +30 PSF 1 -32 PSF7
036 Singler Car Steel Pan I Yes +30 PSF -32 PSF
037 Singler Car Steel Pan No +30 PSF -32 PS
03.8 Singler Car Steel Pan N/A 91-01, +30 PSF -32 PSF
Gallery/Artistry/ Expressions
039 Singler Car Steel Pan No +32 PSF -37 PSFLI
040 Singler Car Steel Pan Yes +32 PSF_ -37 PSF
041 Singler Car Steel Pan with 9--o- 30 PSF w-32 PSF
[single-car Reserve Wood N/A 9,_01. +32 PSF -36 PSF
Double Car Reserve Wood N/A 16'-0" 0 PSF -33.5 PSF
Full View Aluminum 12,'2" r712_2'-]l +32 PS -32 PS
IFull View Aluminum-16'2" N/A 16-2" +30 PSF] -30 PSF
Full View Aluminum(2) 16'2" N/A 1 +32 PS -32 PSE]
Full View Aluminum 20'2" N/A 20-2" 0PSF_�F
� -30 PSF
Double Car Double Skin EPS No 16'-0" +30 PSF -30 PS
Double Car Double Skin EPS Yes 16'-0" +30 PSF—r -3-0 PS
Double Car Double Skin EPS (46) N/A +30 PSF -30 PSF
Gallery/Artistry/ Expressions
Double Car Double Skin EPS (47) 2" N/A =16-0' +30 PSF -30 PSF
Gallery/Artistry/ Expressions
Double Car Double Skin EPS with N/A 16'-0" +30 PSF -30 PSF
Overlay (48)
Clopay Building Products Co.,Inc.(CBPC)132639 1 Rev:Oct 16 2013 12:51PM J Uncontrolled Copy Page 2 of
Report prepared for:Scott Hamilton(Clopay Building Products Co.,Inc.(CBPC))on 5/29/2014 10:56:59 A 4Sp c'DllREcT P& qu sy
Double Car Double Skin EPS with N/A 16'-0" +30 PSF -30 PSF
Overlay (49) 2"
_ Double Car Double Skin PUR N/A 116'-0" +32 PSF -32 PSF
Double Car Double Skin PUR with N/A 16'-0" +30 PSF -30 PSF
Overlay
052 Double Car Steel Pan Yes 16'-0" +30 PSF -30 PSF
053 Double Car Steel Pan No 16'-0" +30 PSF -30 PSF
054 Double Car Steel Pan No 16'-0" +30 PSF -30 PSF
055 Double Car Steel Pan Yes 16'-0" +30 PSF -30 PSF
Double Car Steel Pan Gallery/Artistry/Expressions N/A 16'-0" +30 PSF -30 PSF
058 Double Car Steel Pan I Yes 16'-0" +32 PSF -37 PSF
059 Double Car Steel Pan I No 16'-0" +32 PSF -37 PSF
060 Double Car Steel Pan No 16'-0" +32 PSF -37 PSF
061 Double Car Steel Pan Yes 16'-0" 1 +32 PSF -37 PSF
062 Double Car Steel Pan with Overlay I N/A 16'-0" +30 PSF -30 PSF
-T IDouble Car Double Skin EPS I No 16'-0" +32 PSF -32 PSF
Double Car Double Skin EPS IF Yes 16'-0" +32 PSF -32 PSF
068 Double Car Steel Pan Yes 16'-0" 1 +34 PSF -35 PSF
069 Double Car Steel Pan Yes 16'-C- +32 PSF -32 PSF
070 Double Car Steel Pan ! No 16'-0" +32 PSF -32 PSF
Single Car Double Skin PUR N/A 9'-0" +30 PSF -32 PSF
Gal lery/Artistry/Expressions
Dobule Car Double-skin PUR (1-3/8") N/A 16'-0" +30 PSF -30 PSF
Gallery/Artistry/Expressions
Double Car Double-skin
PUR (2") N/A 16'-0" +30 PSF -30 PSF
Gallery/Artistry/Expressions
Attribute Value
Criteria ASTM E330 (2002)
Criteria ASTM E1886 (2002)
Criteria ASTM E1996 (2002)
CSI Code 08 30 00 Specialty Doors and Frames
Intertek Services Certification
Listed or Inspected LISTED
Clopay Building Products Co.,Inc.(CBPC)132639 1 Rev:Oct 16 2013 12:51PM I Uncontrolled Copy Page 3 of 4
Report prepared for:Scott Hamilton(Clopay Building Products Co.,Inc.(CBPC))on 5/29/2014 10:56:59 AMQnE?,,DIRECT POWERED By
Listing Section WIND LOAD RESISTANT DOORS
Report Number 100487442MID-002, 101196252MID-001
SpeclD 32639
Static Load Test- Design See Table
Pressure
Test Original Issue Date 2012-01-26
Clopay Building Products Co.,Inc.(CBPC)132639 1 Rev:Oct 16 2013 12:51PM Uncontrolled Copy Page 4 of 4