APPLICATION FOR BUILDING PERMIT REVIS NS
PROJECT INFORMATION ENIS" I%Af j=%N
LOCATION/SITE
ADDRESS:
60 q W►!lows A&
Ad- 5f Luce FL 3gIS.R
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
Chawp;na F2m double re l f 7�6 / /a ylr ol" 300 2
luwer kr a:,372sd Sly s
sand
CONTRACTOR INFORMATION:
STATE of FL REG./CERT.#: CCG!3 3 1K 5l ST.LUCIE CO CERT.#:
BUSINESS NAME: 5for'm Team ear.sbwe-kar►
QUALIFIERS NAME: A)s 11 t rn jFol&UZrd1
ADDRESS: ga5d 05 Mw V 1, ,Su ri 3o 3
CITY: J_u 4er STATE: FL ZIP: 33q7"7
PHONE(DAY IME): 5&1^ 512-5$41 FAX:
OWNER/BUILDER INFORMATION:
NAME: �' l
ADDRESS:
CITY: S A ZIP:
PHONE(DAY ME: .. FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE(DAYTIME): FAX:
SLCCC: 9123109
Revised 06%30/17
FILE COPD
DEC 13 2019
Permitting Department
.tet. Lucie.-COUnty, L .
i
t
MIAMI,DADE
MIAMI-DARE COUNTY
- PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
i T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.ralamldade.eov/economy
CertainTeed Corporation
20 Moores Road
Malvern,PA 19355
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be validafter the expiration date stated below.The Miami-Dade County Product Control Se
(In Miami Dade County)and%or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accep Md
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this accep e,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
I including the High Velocity Hurricane Zone of the Florida Building Code.
i
DESCRIPTION: CertainTeed Underlayment Systems
i
f
j LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and follo
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no c-
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement ofany product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
-INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
® FOR a q ( 1
This NOA revises and renews NOA# 17-0306.07 and consists of pRF-�t� CE
I F C®NjPLIAN
The submitted documentation was reviewed by Freddy Senlilp ®uNTY
r
LU
OCC NOA No.: 19-0506.02 DE Cou B Expiration Date: 11/24/24I Approval Date: 07/25/19FILCOPY
Page 1 of 9
i
1
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Underlayment
Material: SBS
SCOPE:
This approves CertainTeed Underlayment Systems,as described in this Notice of Acceptance;designed to comply with
the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code.
I
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product i Dimensions Specification Description
WinterGuard HT 36"x 65' ASTM D 1970 Modified fiberglass reinforced,bituminous sheet
Manufacturing Location rolls material for use as an underlayment in sloped roof
#1 assemblies. Designed as an ice&rain shield.
fWinterGuard Granular 36"x 65' ASTM D 1970 Granular surfaced modified,fiberglass reinforced,
Manufacturing Location I rolls bituminous sheet material for use as an
f g
#2 underlayment ent in sloped roof assemblies.
; P
Designed as an ice&rain shield.
WinterGuard Sand 36"x 32.5' ASTM D 1970 Embedded sand surfaced modified,fiberglass
Manufacturing Location rolls reinforced,bituminous sheet material for use as an
i #2 underlayment in sloped roof assemblies.
Designed as an ice&rain shield.
Diamond Deck' 48"x 250' ASTM D 226 Synthetic,scrim reinforced underlayment for use
i Manufacturing Location rolls Type II under shake, shingles,slate or metal roofing.
#3, 4,& 6
MetaLay_menC. . _ _ 39 Ya"x 6P ASTM D 1970 A film surfaced,self:adhering.underlayment for__..._.
Manufacturing Location rolls use under metal roofing.
#1
Black Diamond' 39 Ys"x 68' 7" ASTM D 1970 Granular surfaced modified,fiberglass reinforced,
Base Sheet rolls bituminous sheet material for use as an
Manufacturing Location underlayment in sloped roof assemblies.
42 Designed as an ice&rain shield.Norfor use"as
an Anchor Sheet.Direct adhesion to wood deck
not permitted in the HVHZ.
i
NOA No.: 19-0506.02
CMIANDADE COUNTY
..1 0 Expiration Date: 11/24/24
Approval Date: 07/25/19
Page 2 of 9
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product Dimensions Test Product
Specification Description
Flintlastic GTA 1393/8,,x 32' 10" ASTM D 6222 Granule surfaced APP Modified Bitumen
Manufacturing Location rolls Grade G membrane with non-woven polyester mat
#1 Type I reinforcement for torch application.
i
All Weather/Empire '39 3/8"x 65' 10" ASTM D 4601 Asphalt coated fiberglass reinforced base sheet.
Base Sheet rolls Type II
Manufacturing Location
#1
Flintlastic GMS 139_3/8,,x 32'l 0" ASTM D 6164 Granule surfaced SBS Modified Bitumen
Manufacturing Location rolls Grade G membrane with non-woven polyester mat
#I Type I reinforcement for mop application.
Flintlastic SA Cap '39 3/s"x 33'11 TAS 103 Polyester reinforced,self-adhering SBS modified
i
Manufacturing rolls bitumen cap sheet.
Location #1
Roofers'Select 36"x 144'rolls ASTM D226 An asphalt-impregnated,organic felt reinforced
Manufacturing Type I with glass fibers,roofing underlayment.
Location #5
RoofRunner 48"x 250 rolls ASTM D226 Synthetic,scrim reinforced underlayment for use
Manufacturing Type II under asphalt shingles.
Location #6
i MANUFACTURING LOCATION:
1. Little Rock,AR.
2. Shakopee,MN
3. Hangzhou,China
-•---- ---4:—_—Silvassa;India __ __. _____._-..-.-.-------___.... _
5. Shreveport,LA
6. Dadra,India
I
i
I
C
NOA No.: 19-0506.02
DADE COUNTY
Expiration Date: 11/24/24
Approval Date: 07/25/19
Page 3 of 9
i
I ,
i
I
I
i
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
TrinitylERD j 3530.12.05-1-R1 ASTM D1623 10/05/09
C32240.03.10 ASTM D4977 03/04/10
C30890.03.10-1 ASTM D1970 03/17/10
C3500.04.10 TAS 103 04/01/10
j C31860.05.10 ASTM D1623 05/18/10
i
040050.09.12-2 ASTM D 1970 09/28/12
C45240.01.14-1 ASTM 1)1970,TAS 110 01/15/14
C32930.01.11-R2 ASTM D1623 01/20/14
C45240.01.14-2 TAS!103,TAS 110 01/24/14
SC6465.05.14 ASTM D 226 05/29/14
j SC7470.10.14 TAS 114 B 10/21/14
CTR-SC 11145.09-3A ASTM D4601 09/19/16
CTR-SC 11415.11.16 TAS 103 11/28/16
CTR-SC 11505.12.16 ASTM D1623 12/22/16
ACT-SC14110.06.17-1 ASTM D 226 06/29/17
ACT-SC14110.06.17-3 ASTM D 226 06/29/17
f
PRI Construction Materials CTC-071-02-01 ASTM D6222 08/08/11
Technologies,LLC CTC-093-02-01 ASTM D6164 ASTM D4798 08/09/11
CTC-163-02-01 ASTM D6757,ASTM D226, 05/09/13
ASTM D4869
InterTek Testing Services"Ltd. 10103165000Q-002C ASTM D226 08/13/13
101227796COQ-003C ASTM D4798 08/13/13
10103165000Q-005C ASTM D4869 08/13/13
I
QAI Laboratories RJ3502-1 ASTM E108 09/29/14
i I
Nemo/etc. 4S-CTR-18-003.09.18 ASTM D4798 9/21/18
4S-CTR-18-003.03.09.A ASTM D226/TAS 110- --- --03/13/19--
. I
i
I ,
a(A�bDADECOUNTY I NOA No.: 19-0506.02
�� Expiration Date: 11/24/24
Approval Date: 07/25/19
Page 4 of 9
� f
i
l
APPROVED ASSEMBLIES:
Deck Type 1: Wood Non-insulated
Deck Description: 19/32"or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened to deck.
I
Anchor Sheet: (4:12 or Above)One or more plies of Diamond Deck with a minimum 4"headlap and a 6"end
lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at the side lap edge
and in is grid pattern spaced 12"o.c.in the field of the roll.
(2:12 to<4:12)One or more plies of Diamond Deck with a minimum 25"head lap and a 12"
end lap mechanically fastened to deck with approved nails and tin caps 6"o.c.at the side lap
edge and in a grid pattern spaced 12" o.c.in the field of the roll.Vertical joints should be offset
72"nunimum.
i
i
Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes,&shingles,quarry
I slate,and metal roof applications. Must Comply with applicable Roofing Application Standards
and Building Codes
Deck Type 1: Wood,;Non-insulated
Deck Description: 19/,2"or greater plywood or wood plank
System E(2): Anchor sheet mechanically fastened to deck.
Anchor Sheet: (4:12 or Above)A single layer of RoofRunner shall be applied with printed side up,parallel to
j the eaves,overlapping each course with a minimum 4"head lap and a 6"end lap mechanically
fastened to deck with approved nails and tin caps 6"o.c. at the side lap edge and spaced 15"o.c.
vertically and 12"o.c.horizontally in the field of the roll.
Surfacing: Shall be acceptable for use in approved asphaltic shingle applications.Must Comply with
applicable Roofing Application Standards and Building Codes
i
t
j NOA No.: 19-0506.02
MIAMI-DADe COUNTY
Expiration Date: 11124/24
Approval Date: 47/25/19
Page 5 of 9
3
I I
I
I
r
Deck Type 1: Wood,Non-insulated
Deck Description: 19132"or greater plywood or wood plank
System E(3): Anchor sheet mechanically fastened to deck.
Anchor Sheet: (4:12,or Above)Two plies of Roofers' Select with a minimum 4"head lap and a 6"end lap
mechanically fastened to deck with approved nails and tin caps 6"o.c.at the side lap edge and in
a grid pattern spaced 12"o.c. in the field of the roll.
(2:121 to<4:12)Two plies of Roofers' Select with a minimum 19"head lap and a 12"end lap
j mechanically fastened to deck with approved nails and tin caps 6"o.c.at the side lap edge and in
a grid pattern spaced 12"o.c.in the field of the roll. Vertical joints should be offset 72"
minimum.
Surfacing: Shall,be acceptable for use in approved asphaltic shingle applications.Must Comply with
iapplicable Roofing Application Standards and Building Codes
Deck Type 1: Wood,Non-insulated
Deck Description: 19/321'or greater plywood or wood plank
System E(4): Anchor sheet mechanically fastened to deck,membrane adhered.
Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4"headlap and a
6"end lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at the side lap
edge and in a grid pattern spaced 12"o.c. in the field of the roll.
Membrane: One or more plies of Flintlastic GTA torch applied to anchor sheet or WinterGuard HT,
;
WinterGuard Granular,WinterGuard Sand,MetaLayment or Black Diamond Base Sheet self-
adhering membrane adhered to the anchor sheet with a minimum 3"headlap and 6"end lap.
Place the first course of membrane parallel to the cave,rolling the membrane to obtain
i maximum contact.Remove the release membrane as the membrane is applied. Vertical
j strapping of the membrane is acceptable.If membrane is strapped,then anchor sheet must also
be strapped.
ShaIl-be acceptable for use in approved asphaltic shingles,wood shakes &shingles-F,-quar-y-- -
slate,and metal roof applications.Must Comply with applicable Roofing Application Standards
and.Building Codes
i
i
i
i
i NOA No.: 19-0506.02
Miar�bDAD;COU TY Expiration Date: 11/24/24
Approval Date: 07/25/19
Page 6 of 9
i
j
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32"or greater plywood or wood plank
System E(5): Anchor sheet mechanically fastened to deck,membrane adhered.
I
Anchor Sheet: One ply of ASTM D 226 Type I1 organic felt or All Weather/Empire Base mechanically
attached with a minimum 4"side lap and a minimum 6"end lap.Anchor sheet shall be applied
at a right angle(900)to the slope of the deck with approved annular ring shank nails and tin
caps at a fastener spacing of 6"o.c. at the side lap edge and in a grid pattern spaced 12"o.c.in
the field of the roll of the base sheet.
Ply Sheet: (Optional)One or more plies of an ASTM D226 ply sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
I
Membrane: One ply of Flintlastic GMS adhered in a full mopping of Type IV asphalt applied within the
EVT range and at a rate of 20401bs./sq. or Flintlastic GTA torch applied to the preceding sheet
or Flintlastic SA Cap, self-adhering membranes adhered to the preceding sheet with a minimum
4"side lap and 6"end lap.Place the first course of membrane parallel to the eave,rolling the
membrane to obtain maximum contact. Remove the release membrane as the membrane is
applied. Vertical strapping of the membrane is acceptable. If membrane is strapped,then
anchor sheet and ply sheet must also be strapped.
When used in Tile roof systems the cap sheet shall be back nailed to deck with approved
annular ring shank nails and tin caps at a maximum of 12"o.c. at the side laps and 6"o.c.at the
end laps. No nails or tin caps shall be exposed.
Surfacing: *Flintlastic SA Cap,Flintlastic GTA and Flintlastic GMS may be used with any approved roof
the system mechanically fastened as specified in their current NOA.
*Flintlastic SA Cap,Flintlastic GTA and Flintlastic GMS may be used with any approved roof
tiles stem adhered as specified in their current NOA using foam adhesive listed and
Y P g an Y
having a current tile adhesive NOA approval.
Must comply with appropriate Roofing Application Standard RAS 118,RAS 119,RAS 120 and
applicable Building Codes.
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,city,
state and the following statement: "Miami-Dade County Product Control Approved"or the Miami-Dade County
Product Control Seal as shown below.
i
MIAMI-DADE COUNTY
, EM
I
i
i
NOA No.: 19-0506.02
CMIAMMMECOU2 Expiration Date: 11/24/24
Approval Date: 07/25/19
Page 7 of 9
I
y
I
{
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of this material.
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. CertainTeed underlayment roofing systems utilizing Flintlastic GTA, WinterGuard HT, WinterGuard Granular,
WinterGuard Sand, DiamondDeck, MetaLayment or Black Diamond Base Sheet as a cap membrane shall be
acceptable for use in asphaltic shingles, wood shakes, & shingles, quant' slate, and metal roof applications.
CertainTeed underlayment roofing systems utilizing RoofRunner or Roofers' Select shall be acceptable for use in
asphaltic shingles.
3. CertainTeed underlayment roofing systems utilizing Flintlastic SA Cap, Flintlastic GTA or Flintlastic GMS as a
cap membrane shall be acceptable for use in foam adhesive set and mechanically fastened roof tile systems as
specified in the surfacing'option of the approved assemblies.
4. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.,CertainTeed underlayment roofing systems shall be installed in strict compliance with
applicable Building Code.
5. CertainTeed underlayment roofing systems membranes shall be applied to a smooth, clean and dry surface with
deck free of irregularities.
6. CertainTeed underlayment roofing systems membranes shall not be applied over an existing roof membrane as a
recover system but may be applied over an approved roofing Base/Anchor sheet underlayment.
7. WinterGuard HT, WinterGuard Granular, WinterGuard Sand, Black Diamond Base Sheet, Flintlastic SA Cap,
MetaLayment, Diamond Deck, Flintlastic GMS, and Flintlastic GTA shall not be left exposed as a temporary roof
for longer than 180 days of application. RoofRunner and Roofers' Select shall not be left exposed as a temporary
roof for longer than 30 days after application.
8. CertainTeed underlayment products may be used with any approved roof covering Notice of Acceptance listing
CertainTeed underlayment products as a component part of an assembly in the Notice of Acceptance. If
CertainTeed underlayment products are not listed, a request may be made to the Authority Having Jurisdiction
(AHJ) or Miami-Dade County Product Control for approval provided that appropriate documentation is provided
to detail compatibility of the products,wind uplift resistance,and fire testing results.
9. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application.
10. When applying the membrane in the valley, start at the low point and work to the high point,rolling the membrane
from the center outward in both directions.
11. Roll or broom the entire membrane surface so as to have 100%contact with the surface,giving special attention to
overlap areas.
12.-Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance andiapplicable Building Code.
NOA No.: 19-0506.02
MwMi DAD6 COUNTY Expiration Date: 11/24/24
Approval Date: 07/25/19
Page 8 of 9
i LIMITATIONS:
13. The maximum roof slope for use as roof tile underlayment in direct-to-deck tile assemblies shall be as follows.
Use of loading boards or batten strips is required on roof slopes greater than that reported in the Table below to
prevent slippage.
i
I TILE SLIPPAGE LIMITATIONS FOR DIRECT-DE =K TILE ASSEMBLIES
Underlayment Tile Profile Staging Method Maximum Slope
Flintlastic GMS Flat/Lugged Max. 10-tile stack 4:12
Flintlastic GTA Flat/Lugged Max. 10-tile stack 6:12
Max. 6-tile stack(4 over
Flintlastic SA Flat 2) 6:12
Cap Lugged Max. 6-tile stack(4 over 5:12
I 2)
i
I
END OF THIS ACCEPTANCE