Loading...
HomeMy WebLinkAboutEngineering RECEME PAUL WELCH INC. DEC 2 3 2019 MECHANICAL ELECTRICAL CIVIL ENGINEERING ST., Lucie County., Permitting 1984 S.W. Bil-TMORE ST -#1 14 PORT ST. LUCIE, FL 34984 (772) 785-9888 E-MAIL: PWELCHINC@)AOL.COM DECEMBER 20, 2019 RE: CASE RE-ROOF 2092 NETTLES BLVD. JENSEN BEACH,FL SCOPE OF WORK: INSTALL NEW METAL ROOF(EXTREME METAL FABRICATORS, LLC. "5-V CRIMP" FL# 17022.6) AT ABOVE REFERENCED ADDRESS OVER NEW UNDERLAYMENT,AND EXISTING PLY-WOOD SHEATHING. DESIGN CRITERIA: l ZID FBC 2017 ASCE?-1 0 j;EVIEWED FOR PROJECT DATA: BUILDING HEIGHT = 12-0" CODE COMPUANCE A= 3 E COUNTY MEAN ROOF HEIGHT = <23' ST. LUCI ROOF ANGLE = 5:12 BOCC 11�0 SHAPE = Hip f 'A ADJUSTMENT FACTOR = 1.00 IMPORTANCE ACTOR = 1.00 WIND VELOCITY V ULT = 165 MPH WIND VELOCITY V ASD = 128 MPH EXPOSURE = D FILE COPY ENCLOSURE CLASS = ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT=-0.1 8 APPLIED UPLIFT DESIGN PRESSURE PER ASCE(PSF): ZONE I (FIELD) =-40.3 ZONE 2 (PERimETER/RiDGE) ^-68.0 ZONE 3 (CORNERS) -99.8 PAUL WELCH INC. PAUL WELCH, P.E. FL. REG. NO.29945 DECEMBER 20, 2019 2092 NETrLEs BLVD JENSEN BEACH,FL 1 bF3. METAL ROOFING ATTACHMENT REQUIREMENTS: METAL ROOFING TO BE ATTACHED WITH CORROSION RESISTANT HEX-HEAD WOOD SCREWS #10 X 1 1/2"MINIMUM WITH WEATHER SEALING WASHERS(MINIMUM 3/16"PENETRATION THROUGH DECK). FASTENERS SHALL BE PLACED THROUGH THE PANEL RIBS AT 12" O.C. ACROSS PANEL WIDTH AND SPACING ALONG RIBS AS FOLLOWS: ZONE 1 (FIELD): FASTENERS SPACING = 6" O.C. ZONE 2 (PERIMETER/RIDGE): FASTENER SPACING 6" O.C. ZONE 3 (CORNERS): = FASTENER SPACING 6" O.C. DESIGN UPLIFT PRESSURE FOR ATTACHMENTS AS PER ABOVE: PRODUCT DESIGN PRESSURE: ZONES 1, 2, &3:-101 PSF UNDERLAYMENT: UNDERLAYMENT SHALL BE TRI-BUILT ROOFING PRODUCTS FL# 16048-R6. "TRI-BUILT S/A HT TU". WHILE PRIMING IS OPTIONAL,TRI-BUILT RECOMMENDS PRIMING THE DECK IF THE FINAL ROOF COVER IS NOT SLATED FOR INSTALLATION WITHIN 24 HOURS. APPLY SHEET PARALLEL TO ROOF EDGE. ROLL OUT APPROXIMATELY 10 FT OF MEMBRANE AND PEEL BACK THE FIRST 3 FT OF RELEASE FILM. ADHERE THE EXPOSED PART TO THE SUBSTRATE AND UNROLLTHE REMAINING MEMBRANE AS FAR AS POSSIBLE. ONCE THE ENTIRE LENGTH OF MEMBRANE IS IN PLACE, PEEL OFF THE RELEASE FILM DIAGONALLY WHILE HOLDING THE MEMBRANE TIGHT. FIRMLY ROLL THE MEMBRANE INTO PLACE TO ACHIEVE A BOND. HORIZONTAL SEAMS SHOULD BE MINIMUM 3-INCHES, CONFIGURED TO SHED WATER. VERTICAL SEAMS SHOULD BE 6-INCHES AND STAGGERED NOT LESS THAN 2-FEET FROM VERTICAL SEAMS IN THE COURSE BELOW. ALL OVER-GRANULE END-LAPS SHALL BE SEALED USING EITHER HEAT-WELDING OR HOT AIR WELDING TECHNIQUES. FOR VALLEYS AND RIDGES: CUT UNDERLAYMENT INTO 4 TO 6 FOOT LENGTHS. PEEL THE RELEASE PAPER AND CENTER SHEET OVER THE VALLEY OR RIDGE IN EACH DIRECTION. DRAPE AND PRESS SHEET INTO PLACE,WORKING FROM THE CENTER OF THE VALLEY OR RIDGE IN EACH DIRECTION. FOR VALLEYS, APPLY THE SHEET STARTING AT THE LOWEST POINT AND WORK UPWARD. DECK INSTALLATION: RE-NAIL ALL PLYWOOD SHEATHING(15/32"THICK MINIMUM)WITH 8-D RING-SHANK NAILS AT 4"O.C. PERIMETER AND 6" O.C. FIELD FOR ALL ZONES. ALL WORK TO BE IN COMPLIANCE WITH PRODUCT APPROVAL (FL# 1 7022.6), FL# 16048-R6), MANUFACTURER'S SPECIFICATIONS,AND THE FLORIDA BUILDING CODE 2017. PAUL WELCH INC. PAUL WELCH, P.E. FL. REG. NO.29945 DECEMBER 20, 2019- 2092 NETTLES BLVD JENSEN BEACH, FL _ 2-OF 3. } o a 7 7 i i b � Y f J i f J ol (D 9;oz (D s ROOF ZO E 1 L A N V,02 (D— SONE D,L'-MrX4 M..'f I ypjt 4L1 NOTE: PROVME LAP SEALANT FOR ALL ROOF PANEL LAWS FOR ROOF SLOPES 1.''DFR 3 "vERT. :12 FIORZ- PAUL WELCH INC. PAUL WELCH, P.E. FL. REG. NO.29945 DECEMBER 20;2019 2092 NETTLES BLVD JENSEN BEACH,FL - n 3.OF 3.