To Whom It May Concern:
ST. Lucie County., Perml!t g
As outlined in the Florida Building Code, Extreme Metal Fabricators, LLC.will accept the installation of metal
roofing panels over one layer of shingles or modified roofing, assuming all requirements of "Florida Building
Code 5h Edition (2094) Section 9510 Reroofing, 9590.3 Recovering versus replacement", andlor"Florida
Buiding Code 5°i Edition (2014) Residential Section 905.10 and Reroofing Section 907'have been met.
It is important to ensure the existing substrate is not deteriorated, there is no entrapped moisture, meets all
code requirements, and to install an approved separator underlayment,between the existing roofing and the
metal panels, such as those that comply with ASTM D226 Type I or Type II or ASTM D 1970, or ASTM D
4869.The roofing contractor of record must verify the aforementioned requirements. Having confirmed code
requirements, installation in this manner is approved by Extreme Metal Fabricators, LLC as the manufacturer.
Plywood sheathing must be minimum 15732" CDX'plywood or'/"wood plank, solid decking, fastened per FBC
requirements. The wood substrate must be inspected to ensure that it has not deteriorated and is acceptable
as.a suitable substrate for additional roofing. Fasteners used should penetrate minimum '1" through structural
decking or a minimum of 1" penetration into a thicker wood substrate, to insure pull-out values remain the
same.
Consideration should be given to the unevenness of the underlying shingles,which may telegraph through the
new metal panels. As in all metal roofing, "oil canning" is an inherent condition that can occur in the panels_
Care should be taken during the installation, to observe the metal panels as they are installed, and adjust
installation procedures, if possible, to help to minimize `oil canning". "Oil Canning"is an aesthetic issue not a
structural issue, and not a cause for rejection.
The energy savings that is normally observed after a new metal roof replaces the previously shingled roof, may
be negated due to the underlying shingles holding heat energy much longer than a metal panel installed
without shingles beneath it. REVIEWED FOR
It is important to comply with allrequjrdments of the Florida Building Code, Fir eQi`MKAANGE
code requirements. As always, authorities having jurisdiction, (building depar1rW I rE00 9, Y
approve your demolition and reroof installation methods, prior to beginning work. B®CC
Ffle Cop
Extreme Metal Fabricators, LLC
9 2160 SW Poma Drive Palm City, FL 34990 ©(772) 223-4055 (Phone) w(772)781-7492 (Fax)
EXSTO E
i
�- 'Florida Building Code Online
�g�a `;•s v ����'°d`t��#r4�t�������a�•.i_ '�•"�a .� �„��7�'-�� ��� �*r'�i`��" � �z%*�.ir�z,._ _..,
S,taut _
�i'
SM Hmm S t.og In 1 1.tspr Registration i —TCPI-i Submit$wdwrge 51aes 6 rads i Pubrrt 111 S faC Staff= SM Site Map i Links 't Smrdl
i
Fioiida
uctapprovalR � �xiIOpw:d
usm haft Lisw'
DEC L 6 2019
Product 0.00rmtal Meru>Product w JipaHrB;tian Ssardr>Aaollratinr+List>6yPIi[atlon QCRan
6 x x C a FU0378-R1
Application Type Revision ST. Lucie County, Permitting
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Extreme Metal Fabricators LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City,i9..34990
(772)872-8034
iivalidation@yahoo.com
Authorized Signature Richard McKuhen
fivalidatian@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Prima Drive
Palin City,FL 34990
(772)872-8034
iichard@emfab.net
i
Quality Assurance Representative REVIEWED F O R
Addr*/PhoneiEmatl CODE COMPLIANCE
Category Roofing ST. LUCIE COUNTY
Subcategory Metal Roofing OCC
I
Compliance Method Evaluation Report from a Florida Registered Architect or a Licer sed
I Florida Professional Engineer
Evaluation Report-Hardcopy Received
i
Florida Engineer or Architect Name who developed LOCKE BOWDEN
the Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R.Priest,P.E.
W Validation Checklist-Hardcopy Received
Certificate of independence R20M 111 COI FL 2037a.1 NAILS-T IP 1.0 .032 ALUM sss.ndP
Referenced Standard and Year(of Standard) Mandard Year
TAS 125 2003
UL 1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
ane Copy
httac//www#laridabuildinLy-orF-r/0r/0r a00 dtl.asnx?naram--WGEVXUwtDoua%2flA4Z8n5C_-. 1/312018
1
CREEK
Certificate of Authorization No.28824 '
17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL, SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017)
Manufacturer: ATLAS ROOFING CORPORATION Issued September 30, 2017
2000 Riveredge Parkway, Suite 800 -- — --
Atlanta, GA 30328 RMdEIV� -
0
(770)612-6267
www.atlasroofing.com D EEC 2 6 2019
Quality Assurance: UL LLC(QUA9625) ST. Lucie County, Permitting
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507-1.1, 1518.4, 1523.1.1, 1523.6.5.2.1
Properties: Physical properties
REFERENCES
Eflft Report No. Standard Year
PRI Construction Materials Technologies(TST6049) ATL-033-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) ATL-068-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) ATL-068-02-01 ASTM D 4798 2011(2016)
PRI Construction Materials Technologies(TST6049) ATL-068-02-01 TAS 110 2000
PRI Construction Materials Technologies(TST6049) ATL-069-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) ATL-090-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST6049) ATL-149-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) ATL-164-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) BWR-533-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST6049) BWR-543-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) MSA-004-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) MSA-007-02-01 UL 1897 2012
PRI Construction Materials Technologies(TST6049) MSA-026-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) WRMI-011-02-01 ASTM 1970 2015a
PRI Construction Materials Technologies(TST6049) MSA-007-02-01 UL 1897 2012
PRI Construction Materials Technologies(TST6049) MSA-030-02-01 ASTM D 1970 2015a
UL LLC(TST1740) 02-NK40952 ASTM D&176
UL LLC(TST1740) 02-NK40952
UL LLC(TST1740) 02-NK40952 26 0
UL LLC(TST1740) 02-NK40952 C® D 380�� �
UL LLC(TST1740) 02-NK40952 LUCIE +C �p
B®VC H
File COPY
ATL14001 AA FL17322-R4 Page 1 of 4
This evaluation report[is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation reportidoes not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed;herein.
,
i
i
r ,
����� ATLAS ROOFING CORPORATION
Roofing Underlayments
TECHNICAL SERYICEs,LLC
PRODUCT DESCRIPTION
i
#15 Specification Felt ASTM D 226, Type I asphalt saturated organic felt underlayment for use in the
HVHZ and non-HVHZ.
#30 Organic Saturated Felt ASTM D 4869, Type II asphalt saturated organic felt underlayment for use in the
non-HVHZ only.
#30 Specification Felt ASTM D 226, Type II asphalt saturated organic felt underlayment for use in the
HVHZ and non-HVHZ.
#43 Base Sheet ASTM D 2626 asphalt saturated and coated, non-perforated, organic felt
underlayment for use in the HVHZ and non-HVHZ.
#90 Mineral Surface Roll ASTM D 6380, Class M asphalt-saturated organic roll roofing sheet for use in the
Roofing HVHZ and non-HVHZ.
Gorilla Guard®EVERFELT 30 Asphalt-saturated organic felt underlayment reinforced with glass fiber that meets
the performance requirements of ASTM D 226, Type I for use in the HVHZ and
non-HVHZ.
Slatelfile Underlayment ASTM D 6380, Class M asphalt-saturated organic roll roofing sheet for use in the
HVHZ and non-HVHZ.
WeatherMaster@)Ice and ASTM D 1970 SBS modified, self-adhering underlayment reinforced with a
Water 100 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a release film, which is removed during
installation.
WeatherMaster@)Ice and ASTM D 1970 SBS modified, self-adhering underlayment reinforced with a
Water 200 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a split-release film, which is removed during
installation-
WeatherMaster@)Ice and ASTM D 1970 SBS modified, self-adhering underlayment reinforced with a
Water 216 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a split-release film, which is removed during
installation.
WeatherMasterO Flexible Ice ASTM D 1970 SBS modified, self-adhering underlayment with plastic film surface
and Water for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with is
split-release film,which is removed during installation.
WeatherMaster@)Pro-Grade ASTM D 1970 SBS modified, self-adhering underlayment with a fiberglass mat
Ice and Water reinforcement and a poly-fabric surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a release film, which is removed during
installation.
WeatherMaster@)Tile TAS 103 SBS modified, self-adhering underlayment with a fiberglass mat
reinforcement and a poly-fabric surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a release film, which is removed during
installation.
ATL14001.4A FL17322-R4 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are;not
specifically addressed herein.
I '
ATLAS ROOFING CORPORATION
CREEKRoofing Underlayments
TECHNICAL SERVICES, LLC
APPLICATION METHOD
Installation shall be in,accordance with the published manufacturer's installation instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting
joints.
Exposure of the underlayments shall be limited to a maximum 30 days except as follows:
a) #15 Specification Felt, #30 Specification Felt, and#40 Base Sheet—exposure for than 24 hours may
adversely affect product performance
b) WeatherMaster® Ice and Water 100, WeatherMaster@ Ice and Water 200, and WeatherMaster® Ice
and Water 216—maximum 30 days
c) WeatherMaster® Pro-Grade Ice and Water and WeatherMaster® Flexible Ice and Water—maximum
30 days
d) WeatherMaster® Tile—maximum 90 days
Self-adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
Roof coverings shall be mechanically fastened through the underlayment to the roof deck except as follows (or as
indicated in other current FBC product approval documents):
a) WeatherMaster® Pro-Grade Ice and Water or WeatherMaster® Tile—ICP Adhesives Polyset AH-160
b) Slate/Tile Underlayment or#90 Mineral Surface Roll Roofing — Convenience Products Touch n' Seal
Storm Bond Roof Tile Adhesive, Dow TileBond, or ICP Adhesives Polyset AH-160
Allowable Roof Coverings:
Metal Roof:^. Zompositwor:;. -Wood
Asphalt: Panels and: Photovoltaic 'Shingles and Slate Clay and
Underlayment. Shingles 'Shingles: Shingles Shakes ::Shingles. Concrete Tile`
#15 Specification Felt Y Y Y Y2 Y N
#30 Organic Saturated Felt Y Y Y Y Y N
#30 Specification Felt Y Y Y Y Y Y
#43 Base Sheet Y Y Y N Y Y
#90 Mineral Surface Roll Roofing Y' N N N N Y
Gorilla Guard®EVERFELT 30 Y Y Y YZ Y N
SlateTle Underlayment Y' N N N N Y
WeatherMaster®Ice and Water
100 Y Y Y N Y N
WeatherMastea Ice and Water
200 Y Y Y N Y N
WeatherMasterO Ice and Water Y Y Y N Y N
216
WeatherMasterO Flexible Ice and Y Y Y N Y N
Water
WeatherMaster®Pro-Grade Ice Y Y Y N Y N
and Water
WeatherMaster®Tile Y Y Y N Y Y
Notes: 1)Open valley applications per 1507.2.9.2
2)Wood shingles only
ATL14001.4A FL17322-R4 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
i
GREEK ATLAS ROOFING CORPORATION
Roofing Underlayments
TECHNICAL SERVICES,LLC
WIND RESISTANCE(NON-HVHZ ONLY)
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9.
Underlayment System No.1—WeatherMaster@ Tile only
Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24"o.c.
Underlayment: WeatherMasterS Tile shall be fully adhered to the optionally primed plywood deck.
Maximum Design -52.5 psf
Pressure:
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Roof slope limitations shall be in accordance with FBC requirements.
3) Installation of the evaluated product shall comply with this report,the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Products described within this report may be used as described in other current FBC product approval
documents.
5) Roof coverings shall not be adhered directly to the underlayment unless otherwise approved in this or other
current FBC product approval documents.
6) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest P.E. have demonstrated compliance with the Florida Building
Code, 6►'Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
%,G%XP�G E N' 2 017 09 3 0
' No 74021 /� •2
12:44. 2
7� �= -04'00'
STATE OF :4�
AllO R t p P'NZachary R. Priest, P.E.
Florida Registration No. 21
Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E.does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
i
ATL14001 AA I. FL17322-R4 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are'not
specifically addressed herein.