Loading...
HomeMy WebLinkAboutHome Center of Port St. Lucie 37102r' t STATE OF FLORIDA DEPARTMENT_ OF HEALTH AND REHABILITATIVE SERVICES APPLICATION FOR SEPTIC TANK PERMIT AND FINAL INSPECTION FORM •,, •,.� Authority: Chapter 381, 386, 387, FS A Chapter IOD-6,FAC DATE ---ReeeMber 6, 1984 Permit Number Name of Applicant Ronald) Kutschinski Telephone No. _567-2310 Mailing Address of Applicant 955 7th Avenue, Suite 16, Vero_Beach, Florida 32960 To Be Installed At: (Give Street Address)' U.S. Highwa 1, Port St. LucieZ Florida _ Lot No. * Block No. Subdivision plat Book Page Size of Lot: 4. 93 Ac -By__ No. Living Units No. Bedrooms No. People -- — Type of BusinessShopping C�PfbVets No. Wash Basins _— No. Employees Total Square Feet in Building 44,000 sq. ,ft.j ____ 'Note. Attach Site Location Map and Other Suppor_ tive Documents LLILA * See attached legal description Signature of Applicant rye SITE INFORMATION Distance to Sanitary Sewer None Distance to Stream, Lake. Canal _ _ N. A. Distance to Public Water Supply At Site Distance to Private Wells) Rainfall Data: None Is Area Subject to Flooding ? No Does Site have Good Natural Drainage? Yes Which Way Does Lot Drain 7 West Any Perimeter Ditches? No Depth of Ditches N. A. Is there Standing Water in Ditches? No Depth of Water in Ditches N. A. Distance to Nearest Residence (North -- East -- South 75 r'±' West -- ) Are Buildings in t!'is Area on: Septic Tanks xx Sand Filters Other Any Known Drainfield Failures in this Area No sz" SOIL PROFILE AND PERCOLATION DATA Water Table At inches N jzs„ SEE ATTACHED Hard Pan At Inches W ,T Clay At Inches z a n^ Muck At Inches - n Other At Inches N'g,. Soil Classification: Class II Group GC so• Percolation Rate: IN TA LATION SPECIFICATIONS Septic Tank Capacity: 777-7 Drain Tile (Linear Ft.): Vt Dosing Tank Capacity: Sand Filter Size: (Sq.FL) Grease Trap Capacity: Absorbtion Bed Size: (Sq.Ft.) Perforated Pipe: (Linear Ft.) Lateral Drainfield Size: (Sq.Ft.) Other Specifications: O - - RECOMMENDATION: Approval -,w, Disapproval❑ Date Processed / Signatureof Sanitarian County Health Department ✓ FINAL INSPECTION DATA - Date and Time of Inspection Type of Tank(Concrete, Fiberglass, Etc.)_ Sae Tank Installed grainfield Size No. Tile Feet Dosing Tank Size _Grease Trap Size Sand Filter Size Who Made installation RECOMMENDATION: Approval ®Disapproval HRS-H FORM 4016. Aug 76 (Rpbw lam-4261 Signature of Sanitarian _ v;7z•.t vJ5%�n�,o dE /NS%GLCC f3CC'G�G SIC 7'6 C���6irtJ�L-.�G� .f�CSic✓✓ - SEPTIC TANK CONSTRUCTION PERMIT (a) Instal6ttion must tre in accord with •cquitements of Chapter 10 D • G, Florid, Administrative Cotle. (b) Final inspection required nefore work is covered. (c) Permit void it not us0 within one year. (d) Approved Installation dues lint guarantee performance. (0) Other __.. • 7-1 5Td ��T �vciE11J BUILDING PLAN CHECK ' ST. LUCIE COUNTY -FORT PIERCE FIRE PREVENTION BUREAU r FORT PIERCE, FLORIDA 33450. TELEPHONE 465-6655 PLAN NUMBER #1164 DATE RECEIVED 1/8/85 CONTRACTOR: AnchorPHONE NUMBER: ARCHITECT: Jack Borger PHONE NUMBER: OWNER: Fred Morgan & Ronkutschinski LOCATION: South U.S. #1 - PSL TYPE OF OCCUPANCY: Mercantile TYPE OF CONSTRUCTION: IV SIZE OF BUILDING: 44,000 sq. ft. NUMBER QF FLOORS: REQUIREMENTS To COUNTY BUILDING OFFICIAL' 1. Tenant separation shall run continuous from floor to under side of roof deck. 2. Electrical outlets shall be staggered on one (1) hour fire rated tenant separating walls. 3. Portable fire extinguishers: One 2A10BC minimum every 75 ft. of travel distance 4. Emergency lighting. Every Class A or B store required. Class C stores. (recommended 5. Illumination of means of egress. 6. Marking of means of egress. 7. Exit requirements shall comply with Class of store in NFPA 101. 8. Interior finish A or B. 9. Any class A or B shall be equipped with a manual fire alarm system. (3,000 or more) a 10. Plans reviewed for building shell only. CONTRACTORS RESPONSIBILITY TO NOTIFY BUREAU ON ALL INSPECTIONS REVIEWED BY: � G�•-� C�� DATE GRATE_- ENERAL NOTt DISCHARGE EL. = /1.9 BEVELED EDGES: ALL EXPOSED CORNERS AND EDGES TO BE CHAMFERED 3/4 , ' V -NOTCH EL. I L O FL. /2.25 2/ "X /5 "CMP T ev i +� 2" Ca . r a = 4 BARS )2"aC{� f ' FOUNDATION MATERIAL: WHERE MATERIAL UNSATISFACTORY- FOR FOUNDATION IS ENCOUNTERED AT FLOW LINE, OMIT FLOOR AND CARRY WALLS DOWN TO SATISFACTORY FOUNDATION. BACKFILL TO FLOW LINE WITH CLEAN SAND. " /B/9" /B or 20 EL. l/.0 B" 6 d B" GRATES: GRATES SHALL BE HEAVY DUTY -SUITABLE FOR TRUCK TRAFFIC. I 4 L 2" � 4 I_ 4 y it li l 45° I II 2- 3 Bars, 5=60Long ?6' 2 Holes for No.4 Na 5 Bars, 18 "Long (2) Embedded )n Pavement lB' or 20' T.I SECTION B"COMPACTED SUBGRADE 9501,AASNTO T-99 SEE GENERAL NOTES n I TF'a i Iq TRiTIC TURF DE TAIL T YP/CA L PA VEMEN T SECTION �s 2/"x/5"CMP� { ' 4„ 4„ 2 11 R. ° Frl 2 R. to CURB DE TA /L /0,_ PA .,. t -JIM VACANT --- - R/W - U S,---_ _HIGHWAY NQONE /moo'" T.aA- A4N0 `/!L!/E SE,Q[/ICE TiLP /mac,'X w" Lf/ET z;l I .SE,Q✓ICE TQO .SE.fY/CE L/At/E To Ai(ETF.GA _� �.. � .✓N,p ifi(ETE,C c4Y G'FNE.P.0 L IJEIiEG oPiifE.vT !c0'-�o'"iOIJCT/LE /.QO�t/ �O'" to"aVCT/LE ' ,��Z AAi1//ITE.e .L1ETE,Q I i ✓' 2" W.arE,e .SE,e vic6 I N H H H H H H \ RETAIL SHOPPING CENTER GCL,eA19 0011 C EA s"EAoT/C T.d.vK REVISIONS PORT ST. LUCI£ MEDICA L PLAZA C F S AND ASSOCIATES, INC. HOME CENTER OF CONSULTING ENGINEERS and PORT ST. LUCIE LAND SURVEYORS WATER AND SEWER PLAN FT. PIERCE,FLORIDA DESIGNED DRAWN DATE SCALE FILE NO. J08 NO. SHEET B. C. D. F. //-28-84 /"= 30 842/ 2 / of 2 4 !; :f{3 s a t zn nA y� e S_ .i5 "�_`� - 3�f •' I "�"A} 9^ � � 1 �.n,.i.^ 'i "bx Y. Y �/aFYdu' y'�> 2 At IF 4r2 = O 3 •• i?VC. /if/FG G/E�c/T /JpUUJT,GBG E- //.SL //E BOX ABSORPTION BED -PLAN VIEW 1 p L� A B�•GKF/G L \ B� • • P. I o o a ABSORPTION BED - SECTION SEPTIC SYSTEM SPECIFICATIONS 1. Tank shall be provided with a suitable legend cast or stamped into the wall at the inlet end, and within 6" of the top of the wall identifying the manufacturer, the year the tank was manufactured, and the effective liquid capacity of the tank. 2. Minimum concrete compressive strength to be 3,500 p.s.i. after 28 days curing. 3. P.V.C. pipe shall be schedule 40. 4. Filter material shall consist of washed and screened gravel, stone, slag or similar material meeting Florida Department of Transportation Specifications under Section 901, "Standard Specifications for Road and Bridge Construction, 198211. Filter material may vary in size from 1/411 to 211 and shall be free from excessive fines. All filter material shall meet the standards of Florida Department of Health and Rehabilitative Services Chapter IOD-6, F.A.C. 5. Filter material in place shall be protected from infiltration by earth backfill by an effective barrier of building paper, polyester bonded filament or other approved materials. OUTLETS LEETT S WELL COMPACTED FILL DRAIN HOLES V MUST BE CLEAR �k% 0eo 0 1 • °o r .� ' eepooe De. r.o000o rOo !/I'ROQT °e°Goo DRANT (36 MIN.BURY) COLOR TO BE STANDARD A.W.WA. YELLOW OR PER LOCAL REGULATIONS —PUMPER CONNECTION FACING STREET mlt i N STRAP RNG LUGS I 6"HYDRANT CONNECTOR COVER MARKED 'WATER ,FINISHED GRADE VALVE BOX ADJUSTABLE SCREW TYPE S VAS DIA. SNAP OR PVC LINER, 6 M. J. TEE OR M 1 REDUCING TEE SIS [0 ACCORDING TO MAIN T"MST BLO ,P I WATER MAN \ 6,M J. GATE VALVE (RESILIENT SEAT) 6. Perforated draintile shall be 411 diameter and shall meet Chapter 1OD-9, F.A.C., and shall have a minimum perforated area of 1.5 square inches per lineal foot located in the bottom half of the pipe. 7. Draintile shall be graded downward from the header pipe at 1/411 of fall per ten (10) feet of length. 8. Control Panel shall contain the following: a. Panel shall be NEMA III and consist of stainless steel b. An interior duplex receptacle shall be provided. c. A high level alarm bell and exterior silencer shall be provided. d. An automatic pump alternator shall be provided. e. Lightning arrestors shall be provided. f. A hand -off -auto switch shall be provided for each pump to provide for manual control. 9. Panel shall be mounted on two (2) galvanized poles with a minimum diameter of 211 which shall be set a minimum of three (3) feet in the ground and concrete encased. The bottom of the panel shall be a minimum of three (3) feet above the finish grade. All hardware to mount the panel shall be stainless steel. UNDISTURBED SOIL d� v• .a" 6 P'o• —2000 P.S.F. CO NC. THRUST BLOCK �+ ,• v ° Q' WITH 13.4 S.F. BEARING AREA rfl Ib 0 Y aL ni I "-EXISTING 1611 D.I. WATER MAIN TAPPING SLEEVE TAPPING VALVE 6" DUCTILE IRON TYP. TAPPING VAVLE AND SLEEVE U S F NO. /7o F/Z<( lrt E co r/E,e, �40.o sr S � •O/dG. o.v 4 °SioEs ,B.P/C,•� To G.Q�OE rere. /2e-7' S CCDT//` TA A//! D/ A A/ I//j'U/ USF t/G7- /70 00!/Ef ��DO "W.5- so, ON 4e S/OES .oE.rf,BOOY .4 NO IBA- •e NES �TiIO�EG .-�>' 21' .QGGESS fll.G,tcE .G NO � D!/E/� - tIc•TU.a G iG(.CSO.v,�y OMEN/.t/� �,Pic,4� TD GQ-Q•� 2¢ 2�%1.• 3G3/mot •, 6 6- h a � d •• O. C. DFF / #- 4f C- -x SEPTIC TANK SECTION VIEW REVISIONS iji1E,000.QY fG OQT / sw/Tc.� co.vr2oG �2J C F S AND ASSOCIATES, INC. CONSULTING ENGINEERS and LAND SURVEYORS FT. PIERCE,FLORIDA Z'�'3'� /�t/c•?E6SE,e ,BEO co�.vo�u/r C�FGO,s7' GO.VT.2DG To CO.t/T,000 �sft/EG ,S'-EE C0.2NE.2 .OETA/G �fEG O W CORNER DETAIL /�Es�sjQOy 4''.9.•L,P(/ES .LlDOEG /Y22 �d v o GO t/E.e °#S4f 3"o1Yc ra .�GSD.2PT/o.c/ �E�J G'F/E'G�Y `a c uE 2 —.oE"sL.y00Y B6-•�NCS /2 ,�Eao.) illooEG SE4// FIRE HYDRANT DETAIL DESIGNED DRAWN DATE SCALE B. C. D. F. 11- 2B -B4 — THAT PORTION OF LOTS 5, 6, AND 7 OF BLOCK 3, SECTION 26, TOWNSHIP 36 SOUTH, RANGE 40 EAST, PLAT N0,1 OF ST. LUCIE GARDENS AS RE- CORDED IN PLAT BOOK 1 AT PAGE 35 OF THE PUBLIC RECORDS LUCIE COUNTY. FLfoRIDA, DESCRIBED AS FOLLOWS: COMMENCE AT THE POINT OF INTERSECTION OF THE WESTERLY RIGHT OF AY LINE OF FLORIDA STATE ROAD N0. 5 (U.S. 1) AND THE NORTH LINE OF \ / ". " SAID LOT 6: THENCE SOUTH 27031'40" EAST ALONG SAID WESTERLY RIG T IL " OF WAY LINE OF LORIDA STATE ROAD N0. 5(U.S. 1) FOR 465.00 FEET; THENCE SOUTH 62 28'20" WEST FOR 350 FEET TO THE POINT OF BEGINNING. THENCE CONTINUE SOUTH 62028'20" WEST FOR 87.03 FEET TO A POINT OF \ CURVATURE OF A 272.87 FOOT RADIUS CURVE LEADING TO THE RIGHT; TH64N SOUTHWESTERLY ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 24 '+9'54" FOR AN ARC OF 118.26 FEET TO A POINT OF INTERSECTION1 V�1� WITH THE EASTERLY RIGHT OF WAY LINE OF A.T. & T. COMPANY, AS RE- CORDED IN DEED BOOK 136 AT PAGE 304 OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA; THENCE NORTH 31013'28" WEST ALONG SAID EASTERLY RIGHT OF WAY LINE OF A.T. & T, COMPANY FOR 280.07 EET; 1' THENCE NORTH 62 28'20" EAST FOR 13.88 FEET; THENCE NORTH 00600, i % 19" EAST ALONG A LINE PARALLEL TO THE WEST LINE OF SAID LOT 6 FOR 401.16 FEET TO A POINT OF INTERSECTION ON THE NORTH LINE OF SAID 0� �` X9 LOT 6; THENCE SOUTH 89042'28" EAST ALONG THE NORTH LINE OF SAID I 0� LOT 6 FOR 60.00 FEET; THENCE SOUTH 00800'19" WEST FOR 70,73 FEET, THENCE SOUTH 27031'40" EAST, FOR 569.71 FEET TO THE POINT OF BE- / GINNING; SUBJECT TO THE NORTH 15 FEET AND THE SOUTHEASTERLY 30 ;�€T FOR ROAD, UTILITY AND DRAINAGE PURPOSES.v. ` e B /79. Z At kR" x.. J . 'F�asp:• A'yyC iP 4 9` \� i IB' GRASS MEDIAN 25'ASPHALr / ° 31' 40„ 4.45 ACRES y d X E NO../ i i i � s i �—AN17N011 h BILL BOARD \ 35 \ 28007';y°� V, •x ��•'2 l x °pp4 M N p. C o S 31 A5,s, �� d" �..miC.f ¢ SURVEYORS CERTIFICATE REVISIONS JOB NO. SHEET TITLE BLDBOO / HEREBY CERTIFY THAT THE PARCEL SHOWN HEREON /S A BY DATE DESCRIPTION FIELD BOOK: BOUNDARY TOPOGRAPHIC E TRUE AND CORRECT REPRESENTAT/ON OF A SURVEY, MADE UN0.�R PSL—/9 MY SUPERVISION AND DIRECTION AND THAT SAID SURVEY IS AiPRO✓ECT RM / / CONTOURS ATE TO THE BEST OF Al KNOWLEDGE AND BELIEF AND THAT THERE RM PARCEI n - n FILE NO: ANCHOR BUILDING CONTRACTOA ARE NO ABOVE GROUND ENCROACHMENTS EXCEPT AS SHOWN. / - SURVEYO ,1 SEAL SEALED H D li SHEET P K. OU/L L EN _ - - DRAWN BY CHE011 BY: LAND SURVEYOR, INC. OF: ✓OHN K. OUIL L EN RM PROFESSIONAL LAND SURVEYOR PORT Sr LUCIE, FLORIDA STATE OF FLORIDA, NO. 3267 DA7F: SCALE: (305) 335-4466 811184 40 1 Moo nr; � y t s. I 0 { C _ _ 1 . .......... a N S Y � .V i { ( � �1W.KY.J^'!ad rr /i .� X GS tr . ',.' ✓ Est r" a e $ i ^ d k'a k4 s flI(NTEO ON NG r i F S j.1 { 4 r h r F , so) 4 +- 19 i tz N { t4'• 5'z" Lo � 4 , 1 ' ` FO EEC T t ca ► t (-' z ST LUCIE COUNTY . - BUILDING DIVISION ,. : ,.. :. ---l3EVIEWED h A. ����� /„ � I >, ,z 1 4lPa✓n oe