HomeMy WebLinkAboutWind Load Calculation Y
STORM License a cho ee Blvd,
1
4047 Okeechobee Blvd,Ste 106,
West Palm Beach, 33409
Phone(561)229-00404 8SMART
www.StormSmartSE.com
of Southeast Florida
Property Information Building Information
Owner: Catherine Crimley Wind Zone: 160 MPH.
Address: 103 Camelot Drive Exposure Category: D
Fort Pierce,FL 34946 Minimum Building Dimension: 4 ft.
Mean Roof Height: 15 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device FDevice Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
2 Int 74 50 7 38.1 -41.6
3 End 54 39 7 39.6 -52.4
4 Int 37 43 7 40.4 -43.8
5 Int 37 43 7 40.4 -43.8
6 End 37 43 7 40.4 -53.9
7 Int 27 43 7 40.6 -44.1
8 Int 74 43 7 38.5 -42.0
9 Int 37 43 7 40.4 -43.8
10 End 24 30 7 40.6 -54.4
11 Int 53 31 7 40.3 -43.7
12 End 71 83 7 36.9 -47.0
13 Int 74 39 7 38.8 -42.2
Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of 1