Loading...
HomeMy WebLinkAboutProduct Approval � ' "'� '. SX.� l�w"33C�� 6�""a'� ,z�}'�k'�,t 'N—=t• 7: < '�.��'L.a`.i p%,-��*#snp,.. � .n ��'i}°kP ._ Y s kktF5Y�4 wri 3+ `- � 41�•° �� �`'at� .„£e�y�.� B1�} rf BCIS Home Log In i User Registration Hot Topics Submit surcharge `. Stats&Facts ' Publications Contact Us reCiS Site Map links i Search b a - d -1 1■/► Product Approval 1 .-V.. USER:Public User - - Product Approval Menu>Product or AppliWtion Search>gppl Canon Llst>App11o0tion Detail rl_-ta.;}.tu1 rte.. Application Type Revision _ Code Version 2017 — Application Status Approved s s mC7 ov Comments 3 Archived . m Product Manufacturer Drexel Metals,Inc. Address/Phone/Email 204 Railroad Drive Ivyland,PA 18974 (502)303-1511 jshumate@drexmet.com Twp Authorized Signature ]shun Shumate jshumate@drexmet.com {� REVIEWED FOR Technical Representative CODE COMPLIANCE Address/Phone/Email " Quality Assurance Representative _ ST. LU 9 V9 E CO U t Address/Phone/Email B®CC Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Reglstered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R.Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity Architectural Testing,Inc.,an Inteitek Company Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden P.E. 'v Validation Checklist-Hardcopy Received Certificate of Independence FL17678 R6 COI DRX15001.6 2017 FBC Evaluation Report NonHVHZ fnal.pd Referenced Standard and Year(of Standard) Standard Year ASTM B 117 2016 ASTM G155 2005 TAS 100 1995 TAS 110 2000 TAS 125 2003 UL 580 2006 UL1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method I Option D Date Submitted 10/09/2018 Date Validated 10/09/2018 Date Pending FBC Approval 10/21/2018 Date Approved 12/11/2018 Summary of Products FL# Model,Number or Name Description 17678.1 Drexel Metal Roofing Systems DMC 100NS,DMC 150SL,DMC 154SS,DMC 1755,DMC 20DS, DMC 450,DMC 5V&DMC Corrugated Limits of Use Installation Instructions Approved for use in HV#iZ;No FL1 7678 R6 IIRD X15001.6 2017 FBC Eyaluatlon Rep-Qrt Approved for use outside HVHZ,Yes NonHYHZ final.pd Impact Resistant. N/A Verified By. Zachary R.Priest PE-74021 Design Pressure.+0/-180 Created by Independent Third Party:Yes Other:See evaluation report for lirnits of use Evaluation Reports EL17678 R6 AF DRX15001.6 2017 FBG.Evaluation Report NonHVHZ final.pd Created by independent Third Party!Yes contact Us::2501 III&Stone Road.Tallahassee FL 3 o Phone:85Q:jL7-I8?4 The State OF Florida is an AA/EEO employer.CQpvliaht 9007-2013 atate of Florida, privasy,statement I.:ACcessIbIlIN Statement Refund Statement under Florida law,email addresses are public records.If you do not want your e-mall address released in response to a public-records request do not send electronic mail to this er)W.Instead,contact the office by phone or by traditional mail.If you have arty questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,20I2,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click tigre. Product Approval Accepts; M RUN K Credit Card safe ` � Certificate of Authorization No.25824 zx CREEK " 17520 Edinburgh Dr a Tampa,FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,a EDITION(2017) Manufacturer: DREXEL METALS,INC. Issued October 9,2098 1234 Gardiner Lane Louisville,KY40213 (502)716-7143, www.drexmet.com Manufacturing: Drexel Metals Association of Regional Manufacturers(DM-ARM) Quality Assurance: Architectural Testing,Inc.(QUA1844) SCOPE Category: Roofing Subcategory: Metal Roofing Code Sections: 1504.3 Properties: Wind Resistance REFERENCES Entity Retort No. Standard Year Architectural Testing(TST1558) 56840.02-122-18 TAS 100 1995 Architectural Testing(TST1558) 58389.01-122-44 UL 580 2006 Architectural Testing(TST1558) 58459.01-122-44 UL 580 2006 Architectural Testing(TST1558) -58461.01-122-44 TAS 125 2003 Architectural Testing(TST1558) 82776.01-10944 UL 580 2006 UL 1897 2012 Architectural Testing(TSTi558) 82784.01-109-44 UL 580 2006 UL 1897 2012 Architectural Testing(TST1558) 83296.01-109-44 UL 580 2006 UL 1897 2012 Architectural Testing,Inc(an Intertek Company)(TST1527) 1-13245.01-450-18 • TAS 125 2003 Architectural Testing,Inc(an Intertek Company)(TST1527) H9058.02-450-18 TAS 125 2003 Architectural Testing,Inc(an Intertek Company)(TST1527) H9058.01-450-18 TAS 125 2003 Architectural Testing,Inc(an Intertek Company)(TST1527) 13391.01-450-44 UL 580 2006 Force Engineering&Testing(TST5328) 178-0054T-12 UL 580 2006 Force Engineering&Testing(TST5328) 178-0055T-12 UL 1897 2012UL 580 2006 UL 1897 2012 Hurricane Test Laboratory(TST1527) 0287-0209-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0308-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0311-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0313-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0512-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-070&07 TAS 125 - 2003 PRE Construction Materials Technologies(TST5878) VLS-005-02-01 ASTM B 117 2016 TAS110 2000 PRI Construction Materials Technologies(TST5878) VLS-004-02-01 ASTM G 155 2005a TAS 110 2000 ARI Construction Materials Technologies(TST5878) DMC-004-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) OMC-005-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-006-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-007-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-00&02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-009-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-014-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-016-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-017-02-01 Rev 1 UL 580 2006 UL 1897 2012 DRX15001.6 FL17678-R6 Page 1 of 5 This evaluation report Is provided for State of Florida-product approval under Rule 61G20-3. The•manufacturer sha{!notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not,express nor imply warranty,Installation,recommended use,or other product attnbutes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES,LLC Enti R6port No. Standard Year PRI Construction Materials Technologies(TST5878) DMC-018-02-01 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies(TST5876) DMC-02402-01 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies(TST5878) DMC-033-02-01.1 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies(TST5878) DMC-037-02-01 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies(TST5878) DMC-037-02-02 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies(TST5B76) DMC-038-02-01 UL 580 2006 UL 1897 2012 PRODUCT DESCRIPTION DMC I OONS I in.snap lock seam;Max.16 in.coverage_ Description: Non-structural,snap lock standing seem roof panel with integral perorated nail Material: Min.24 ga.Fluropon@ coated ASTM A792 AZ50,or ASTM A653 G90;FY=min.50 ksi; Shall conform With FBC Section 1507.4.3 DMC 150SL Profile,. 1.5 In.snap lock seam;Max 16 in.coverage Description: Non-structural,snap lock standing seam roof panel Material: Min,24 ga.Fluropon@ coated ASTM A792 AZ50,or ASTM A653 G90;Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3 DRX15001.6 FL17678-R6 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty,Installation,recommended use,or other product atinbutes that are not specifically addressed herein. CREEK � DRExELMETALS,INC. Metal Roofing TECHNICAL SERVICES,LLC DMC 450 Profile: 1.5 in.snap look seam;Max.16 in.coverage Description: Non-structural,snap lock'standing seem roof panel with concealed Material: Min.24 ga.'ASTM A792 or ASTM A653; Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3 Min.0.032 in.Fluropon®coated ASTM B209 aluminum;Fy=min.24 ksi; Shall conform with FBC Section 1507.4.3 _JT 1 Z,. _ I _1 DMC 5V Profile: 3/8 in.ribs;Min.21 in.,Max.24 in.coverage Description: Non-structural,through fastened roof panel Material: Min.26 ga.Fluropon®coated ASTM A792 or ASTM A653 G90;Fy=min.50 ksi; NN Shall conform with FBC Section 1507.4.3 Min.0.032 in.Fluropon®coated ASTM 8209 aluminum;Fy=min.23 ksi; Shall conform with FBC Section 1507.4.3 21"up to 24"Coverage —t. 8 DMC Profile: _ 1/2 in.corrugation;21 in.coverage Corrugated Description: N_on-structure 'through fastened roof panel Material: Min.26 ga.Fluropon®coated ASTM A792 or ASTM A653 G90; Fy=min.40 ksi; Shall conform with FBC Section 1507.4.3 Min.0.032 in.Fluropon®coated ASTM B209 aluminum;Fy=min. 19 ksi; Shall _ conform with FBC Section 1507.4.3 2R 11 7 DRX15001.6 FL17678-R6 Page 4 of 5 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor Imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. METALS,INC. CREEK DREXELMetal Roofing TECHNICAL SERVICES,LLb DMC 150SS Profile: 1.5 in.mechanical seam;Max. 16 in.coverage__ Description: Non-structural,mechanical lock standing seam roof panel Material: Min.0,032 in.Fluropon@,oDated ASTM B209 aluminum;Fy T min- 16 ksi; Shall conform with FBC Section 1507.4.3 rw Min.24 ga,Fluropon@ coated ASTM A792 AZ50,or ASTM A653 G90-,Fy=min. 50 ksi; Shall conform with FBC Section 1507.4.3 1H I � 2 a Mibe—ria-k Min.0.027 in.Zinc;Fy=min. 16 ksi; Shall conform with FBC Section 1507.43 DMC 175S Proflk� n.snap lock seam;Max. 18 in.coverage Description: Non-structural,snap lock standing staT_ro�fanel Material: Min,0.032 in.FlurioponO coated ASTM B209 aluminum;Fy=min.24 ksi; Shall conform with FBC Section 1507.4.3 Min.0.040-inch Fluropon@ coated ASTM B209 aluminum(Fy=min.20 ksi); Shall conform with FBC Section 1507.4.3 Min.24 ga.FluroponO coated ASTM A792 AZ50,or ASTM A653 G90;*FY=min.50 ksi; Shall conform with FBC Section 1507.4.3 T— DMC 200S Profile: 2 in.mechanical seam;Max.16 in.oqvergge Description: Non-structural,mechanical lock standing seam roof panel Material: Min.0.040 in.Fluropon@ coated ASTM 8209 aluminum:Fy=min.20 ksl; Shall conform with FBC Section 1507.4.3 Min.24 ga.Fluropon@ coated ASTM A792 AZ50,or ASTM A653 G90; Fv=min.50 ksi; Shall conform with FBC Section 1507.4.3 r. t STT -T 2" 2" DRX15001.6 FL17678-R6 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein, DREXEL METALS,INC. CREEK Metal Roofing TECHNICAL SERVICES,LLC LIMITATIONS 1. Fire classification is not within the scope of this evaluation. 2. This report is not for use in'the HVHZ. 3, The roof deck and,the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance With FBC requirements. 4. Roof slope shall be in accordance with FBC Section 1607.4.2. 5. Reroofing shall be in accordance with FBC Section 1511. 6. Installation of the evaluated products shall-comply with this report, the FBC and the manufacturer's published application instructions. -Where discrepancies exist between these sources, the more restrictive and FBC compliant installation'detail shall prevail. 7. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 614320-3, COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,6s'Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. ot 'nV C i In E Al 2()18. {3.{)9 No 74021 11 :21 -AA STATE OF -04'00' -.10, A%•• V.-* N Zachary R.Priest,P.E. .... !A Florida Registration No.74021 ttirjrtrrxrr lla� % Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will It acquire,a financial Interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest,P.E.does not have,nor will acquire,a financial Interest In any company manufacturing or distributing products under this evaluation. Zachary R Priest,P.E.does not have,nor will acquire,a financial Interest In any other entity Involved in the approval process of the product. APPENDICES 1) APPENDIX A—Installation(12 pages) 2) APPENDIX B—Approved Roof Systems(8 pages) 3) APPENDIX C—Design Wind Loads(4 pages) DRX15001.6 FL1 7678-R6 Page 5 of 5 This evaluation report Is provided for State of Florida product approval under Rule 6IG20;-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the dufatlon for which this report Is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES,LLC APPENDIX A INSTALLATION Note-Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a selected system. Unless otherwise specified In this report the following installation details shall be met for the named products: Component Product Installation Detail 99-15 HWH wood screw with sealing washer #10-14 HWH wood screw with sealing washer Shall penetrate through the sheathing a minimum 3t8 In, Must be corrosion #10-15 HWH wood resistant In accordance with FBC section 1507.4.4. Fasteners screws with dual threads and sealing washer #10-13 PH wood screw #10-16 DP3 PH self- ddlilng,screw Shall penetrate through the top rib of the steel deck a minimum 3/4 In. Must be #14-13 DP1 PH self-, corrosion resistant In accordance with F13C section 1507.4.4. drilling screw Bearing Plates 18 ga.I Bearing Plate 4B 24 ga.In-seam clip DMC 150SL Clip Clips 24 ga.SS in-seam dlp 24 ga.DMC;150SS Clip 0 C> 2" DRX15001.6 FL17678-R6 Page 1 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein. CREEK - DREXELMETALS,IIUC. Metal Roofing TECHNICAL SERVICES,LLC APPENDIX A Component Product. Installation Detail 24 ga.in-seam clip IVp 1 24 ga.DMC 15OSS Fixed , T 1g Clip o • 0 X21 26 ga.in-seam clip .L 26 ga.DMC 15OSS Fixed Clip ' JJ; 22 ga.SS in-seam clip L Clips{Con#'d} 22 ga.DMC 15OSS Clip 3P T o e o tO P T 22 ga.in-seam clip 22 ga.DMC 15OSS Fixed L Clip 6P • o t7 :: 22 ga.base;24 ga,butterfly in-seam Clip l� DMC 16OSS Butterfly !`y Clip 1616" ^ter>. DRX15001.6 FL17678-R6 Page 2 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall nottfy CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or.other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Rooting TECHNICAL SERVICES,LLC APPENDIX A Component Product. Installation Detail 22 ga,base;24 ga.butterfly in-seam clip /ter DMC 150SS Continuous Butterfly Clip 26 ga.In-seam Glp _ —•.' - DMC 150SS Utility Floating Clip i I 111 ....., f Clips(Cont'd) 18 ga.In-seam clip DMC 175S UL Clip C) 0 22 ga.SS in-seam clip 1 7 i f�" DMC 200S Clip '° T O I 0 o 0 3" DRX15001.6 FL17678-R6 Page 3 of 12 This evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. .' CREEK DREXEL etalR Roofing,Metal Rooting TECHNICAL SERVICES,LLC APPENDIX A Component Product Installation Detail 18 ga.base;22 ga.butterfly in-seam clip;4.5 in.length DMC 2005 Butterfly Clip 18 ga.base;22 ga.butterfly inseam clip;120 in.length;fop slider 12 In.o.c. DMC 2005 Continuous Butterfly Clip Clips(Cont'd) 24 ga.in-seam clip DMC 450 Clip 24 ga.SS In-seam clip DMC 45OSS Clip t,. Sealants Bostik 70 05A Shall be applied in continuous beads along the seam Bostik Chem-Calk 915 d . 'Fastening Details Nomenclature Attachment DMC I DONS PANEL DMC 90QIUS Standard - ' DRX15001.6 FL17678-R6 Page 4 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. M.. .: DREXEL METALS,INC. CREEK Metal Rooting TECHNICAL,SERVICES,LLC APPENDIX A Component I Product 'Installation Detail DMC'IDUDS PANEL BQSTIK 7"SA(2 - 3/16" BEADS) #1U 13 PHW DMC 100NS Enhancer! DMC 1509L PANEL OM0150SL CUP #10-13 PHW(2 Per Cfip) UNDERLAYMENT DMC 150SL Standard _ L DMC 150SS PANEL DMC 15055 CONTINUOUS BUTTERFLY CLIP------------- �'�� (2)#10-13 PHW•---------------- I UNDERLAYMENT- DMC 150SSContinuous SUBSTRATE-} Butterfly t DMC 1508S PANEL DMC 15088 BUTTERFLY CLIP (2)#10-13 PHW ------I '�, UNDERLAYMENT —; DMC 15088 Butterfly SUBSTRATE ii 4 i • 1I r i DRX15001.6 FI-17678-R6 Page 5 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein. t CREEK DREXEL Metal Roofing TECHNICAL SERVICES,LLC APPENDIX A Component- Product, Installation Detail DMC 15pSS PANtIL.--, DMC 1SO$$BUTTERFLY CLIP (2)#14-13 PHDD UNDERPAYMENT 34-1 SGA BEARING PLATE— ��. ` ISO INSULATIQN—t`\1\ �11 METAL DECK DMC 15OSS#14 Butterfly ;.. •; %r DMC 15OSS PANEL--_ 24 GA DMC 150SS FIXED CLIP (2)#10-13 PHW UNDERLAYMENT----, DMC 15OSS Fixed-90 SUBSTRATE ll - srrHE,laer%,mcxELLrAulttis �;•"'-"APPLIED TO H0711 SIM OF CUP :--_......OUC UM PANEL .•_. 244AONC ISM FIMO CUP i!Y DBAO HOH'fIK CNE►i{AL%B' •�--.APPLISO TO GOTH 310E OF CLIP DMC 15OSS#14 Fixed- 90 2 #14-13 DPi PH Screws per clip;Clip installed over 18 ga.bearing late DMC 1SOSS PANEL 24 GA DMC 15OSS CLIP--- — •, (2)#10-13 PHW__..__.-. ...--_. UNDERLAYMENT— DMC 15OSS Standard(Al) SUBSTRATE j r r DRX15001.6 FL17678-R6 Page 6 of 12 This evaluation report is provided for State ofFiorida product approval under Rule 6iG20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not spedficalfy addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES,LLC APPENDIX A Component Product lnstallation•Detail 11W BEAD BOSTIK 7"M DMC 150SS PANEL- _......_ .. .. 22 GA DMC 15088 FIXED CLIP DMC 150SS Fixed (2)#10-13 PHW Enhanced-90 UNDERLAYMENT - —. SUBSTRATE • 4 � ti DMC 150SS PANEL- 22 ANEL 22 GA DMC 15088 FIXED CLIP-­-- .... (2)#10-13 PHW----i . UNDERLAYMENT---� t DMC 150SS Fixed SUBSTRATE -1 y .Enhanced-180 l r 114"BEAD BOSTIK 70-05A--•., DMC 15058 PANEL--� h 22GADMC150SSCLIP (2)010-13 PHj DMC 150SS Enhanced(Al) UNDERLAYMESUBSTRA DRX15001.6 FL17678-R6 Page 7 of 12 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK . Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK��Tr� DREXEt_METALS,INC. �" Metal Roofing TECHNICAL SERVICES,LLC APPENDIX A Component • Product_ installation Detail DMC 15O9S PANEL ' DMC 150S CLIP (2)#10-13 PH Screws UNDERLAYMENT DMC 15044 Zinc SUBSTRATE— s. t _ v DMc 1TSs panel• DMC 1755 UL Qp•-•---_•`_ #1043Screw PH —� - 12)Der relipaND DMC 1755#10 Standard � �� DW175SParw 01AC 1755 UL CUP 1110.13 PH Screw--••—••• ''•. i tperrSo 114"HEAD HDSYM CHEM-CALK .••1 676 MALE LEGANDDOTN 31DE$ of CUP '4 •' lir WADHOSrKCNEM.CALK . DMC 1755#1O Enhanced 4150N FEMALE LEC ' 1 DRX15OO1.6 _ FL17678-R6 Page 8 of 12 This evaluation report Is provided for State of Florida product approval under Rule:61132O-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valld. This evaluation report does not express nor Imply warranty,Installation, recommended use,or other product athilautes that are not specifically addressed herein. _ CREEK DREXEL METALS,INC. }; Metal Roofing TECHNICAL Smvims,LLC APPENDIX A Component Product. Installation Detail DMC 1765 PANEL DMC 1765 UL CLIP ` 114-13DPIPHDD(ZPerCIp) \ 3X3-18GA BEARING PLATE—i , METAL DECKS ISD INSULATION` ' \ I 'l DMC 175S#14 Standard OMC 2005 PANEL•-••-- DMC 200S BUTTERFLY CLIP............ - (2)#10-13 PHW- UNDERLAYMENT 7 SUBSTRATE ..--, DMC 200S Butterfly r DMC 200S PANEL------� DMC 200S BUTTERFLY CLIP #10-1 B DP$ PHD�� \ UNDERLAYMENT METAL DECK DMC 2005 Butterfly(Steel) Use 18 ga,bearing plate over polyisocyanurate insulation DRX15001.6 FL17678-R6 Page 9 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein. �.� CREEK DREXELMETAL5,INC. Metal Roofing TECHNICAL SERVICES,LLC APPENDIX A Component Product Installation Detail DMC ZOOS PANEL DMC 2005 CONTINOUS BUTTERLY CLIP --\ #10 16 DP3 PHD UNDERLAYMENT DMC 2005 Continuous METAL DECK -- Butterfly(Steel) i Use 18 ga.bearing late over pof Isoc anurate insulation DMC 2005 PANEL - DMC 2005 CLIP (2)#10-13 PHW __........ -} UNDERLAYMENT DMC 2005 Fixed SUBSTRATE - 1 r 11411 BEAD BOSTIK 7"SA DMC 2005 PANEL DMC 2005 CLIP DMC 200S Fired (2)010-13 PHW ----� Enhanced UNDERLAYMENT --� SUBSTRATE~ i Y y t DRX15001.6 FL17678-R6 Page 10 of 12 This evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein. G D E E K DRF�CEL METALS,INC. - 1Z [1 Metal Roofing r� TECHNICAL.SERVICES,LLC APPENDIX A Component Product Installation Detail DMC 450 PANEL DMC 450 CLIP------�` #10-13 PHW(2 Per Clip)---� DMC 450 Standard DMC 450 PANEL —, DMC 450 SS #rR10-13 PHW(2 Per Clip).-• ....... DMC 45OSS Standard 44. .9.15 WM WOOD SCREW WITH S:AUNO WASHER DMC 5V Standard #1b-14 DREXMET WOODSCREW --- --� DMC 5V PANEL- METSHIELD HT UNDERLAYMENT----� DMC 5V#10 Standard PLYWOOD 1 � DRX15001.6 FL17678-R6 Page 11 of 12 This evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. ^•�'� CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL.SERVICES,U.0 APPENDIX A Component Product, Installation Detail DMC 5V PANEL #10-1d DREXMET WoomCREW UNDERLAYMENT 7116"OSB MIN.-- DMC 5V Pan Fastening ONLY REQUIREDAT PANEL ENDS - = - 5 .N '-9" COVERAGE #70 lb HWH WOODSCREW(DUALTHREAD) t2"cx. to 36`o.c. MAX.,ROW SPACING DMC Corrr ugated — UNDERtAYMENT 15/32' WN. PLYWOOD DRX15001.6 FL17678-R6 Page 12 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-8. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor Imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. i CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES,LLC APPENDIX B APPROVED ROOF SYSTEMS The foilowing notes shall be observed when using the assembly tables below. 1. Maximum Design Pressure(MDP)was calculated using a 2:1 margin of safety per FBC Section 1504.9. 2. Refer to LIMITATIONS and sections of this evaluation when using the table(s)below. 3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly. 4. The on-center(o.c.)spacing given is the maximum allowable attachment spacing for the rated system. 5. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga(Fy=min.33 ksi)Wide Rib Deck(Type WR) conforming to ANSI/SDI-RD1.0&FBC_ 6. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 15/324nch thick APA Span-Rated plywood sheathing at maximum 244nch span. Roof System Numbers and Definitions 100NS-W# DMC 10ONS over Wood Deck New or Existing) 150SL-W# DMC 150SL over Wood Deck(New or Existing) 150SS_S# DMC 150SS over Steel Deck New or Existin I 150SS-W# DMC 15OSS over Wood Deck New or Exlstin 175S-S# DMC 175S over Steel Deck New or Existing) 175S-W# DMC 1755 over Wood Deck new or Existing) 200S-S# DMC 200S over Steel Deck New or Existing) 200S-W# DMC 200S over Wood Deck New or Existing) 450-W# DMC 450 over Wood Deck New or Existin 5V-W# DMC 5V over Wood Deck New or Existing) COR-W# DMC Corrugated over Wood Deck New or Existing) Approved Systems for DMC 100NS over Wood Deck(New or.Existing) ISystemDeck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf) Min.15/32 OPTIONAL 24 ga.DMC 100NS DMC 100NS Standard attachment 100NS-W1 CDX plywood Versashleld Solo required per FBC Max.16-inch wide with fastener spaced 10.5 in.o.c. -97.5 Min.15/32 OPTIONAL 24 ga.DMC 10ONS DMC 100NS Standard attachment 100NS W2 CDX plywood Versashleld Solo As required per FBC Max.16-Inch wide with fasteners spaced 5.25 In.o.c. -120 Min.15/32 OPTIONAL 24 ga.DMC 10ONS DMC 100NS Enhanced attachment 100NS W3 CDX plywood Versashleld Solo As required per FBC Max.16-inch wide with fasteners spaced 5.251n.o.c. -135 DRX15001.6 FL17678-R6 Page 1 of 8 j This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. DREXEL METALS,INC. , CREEK Metal Roofing TECHNICAL SERVICES,LLC APPENDIX B Approved Systems foe DMC 150SL over Wood Deck(New.or Existing) System Deck Fire Barrier Underla MDF No. yment Roof Panel Panel Attachment (pso 154SL W 1 Min,15132 OPTIONAL As required per FBC 24 ga.DMC 150SL DMC 150SL Standard attachment -552.5 CDX plywood Versashieid Solo Max.164nch.wide with clips spaced 16 In.'o.c; AParoved Systems for DMC 150SS over Steel Deck New or'Existin System : .Deck,- Fire Barrier.. insulation Underlayment -Roof Panel . Panel Attachment MDP No. (W) Min.22 ga. -Min:1 in.Approved 24 ga.DMC 15OSS DMC 15OSS#14 Butterfly attachment 150SS-S1 Type B, As required poiylsocyanurate As required per FSC Max.16MC wide with cites 14 Buff.36 in.ach 41.7 Grade 80 Steel Insulation board Min.22 ga. Min. in.Approved Approved ASTM D 24 ga.DMC 1WSS DMC 15OSS#14 Fixed-90 attachment 150SS-S2 Type B, As required polyisocyanurate 1970 undedayment Max.16-Inch wide with clips spaced 16 In.o.c.• 71 Grade 80 Steel insulation board . Mtn.22 ga. Min.1 In.-Approved. 24 a.DMC 15OSS DMC 150SS#14 Butterfly attachment 150SSv'`3 Type B, As required polylsacyanurate As required per FBC g y -92.4 Grade 80 Steel insulation.board = Max.Winch wide with clips spaced 24 in.o.c. •• Min.22 ga. MIn:1 In.Approved 24 ga.,DMC 15OSS DMC 15OSS 914 Butterfly attachment 150SS-S4 Type B. As required polylsocyanurate As required per FBC Max.16 inch wide with cops spaced 18 in.o.c. •117.8 Grade 80 Steel insulation board Klin:22 ga. Min.1 In.Approved 150SS-S5 Type B, As required poi 'so 24 ga.DMC 150SS DMC.15OSS#14 Bufferfly attachment _.. _ y� cyanurate As required per FBC Max.16-inch wide with s 447.1 . Grade 80'Steel insulation board p$ paced.12 in.o.c. Min.22 ga. Min.1 in.Approved 24g e.DMtt C 150SS DMC 15OSS#14 Bue attachment 150SS S6 Type B, As required polyisocyanurate As required per FBC _168,5 Grade 80 Steel Insulation board Max.16-inch wide with clips spaced 6 in.o.c. DRX15001.6 FL17678-R6 .Page 2 of 8 This evaluation report is provided far Statebf Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality'swurance-changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. METALS,INC. CRDREXEL EEK Metal Roofing TECHNICAL SERVICES,LLC APPENDIX B Approved Systems fdr,DMC ISOSS over Wood Deck(N"or Existing) System Deck Fire Baffler Underlayment Roof Panel MDP No. Panel Attachment (psQ Min.15/32 OPTIONAL Approved ASTM D 0.02T'(0.7mm)Zinc DMC 150SS DMC150SS Zinc attachment 150SS-W1 Max.15.7-4nch wide with DMC 150SS Utility Floating Clips -78.5 CDX plywood Versashleld Solo 1970 undedaymentMax. seem spaced 18 in.o.c. Mn.102 OPTIONAL Approved ASTM D 0.027'(0.7mm)ZJnc DMC 150SS DMC15OSS Zinc attachment 154S5-W2 CDX plywood Versashield Solo 1970 undertayment Max.15.7-inch wide with DMC 150SS Utility Floating Clips -86 1800 seem spaced 6 in.o.c. Min 15/32 OPTIONAL Approved ASTM D 0.027°(0.7mm)Zinc DMC 150SS DMC150SS Zinc attachment 150SS-W3 CDX plywood Versashield Solo 1970 undedayment Max.15.7-inch wide with 26 ga.DMC 150SS Fixed Clips spaced -96 seam 18 In.o.m Min.15/32 OPTIONAL 0.032°AI DMC 15OSS DMC 15OSS Standard(Al)attachment 150SS W4 CDX plywood Versashield Solo As required per FBC Max.16-Inch wide with clips spaced 16 in.o.c. -90 180,seam Min.15132 OPTIONAL 24 ga.DMC 150SS DMC 150SS Fixed-90 attachment 150SS-W5 As required per FBC Max.16-inch wide -00 CDX plywood Versashield Solo goo seam 'with clips spaced 16 in.o.c. Min 15/32 OPTIONAL 24 ga.DMC 15OSS DMC 150SS Butterfly attachment 15055 W6 As required per FBC Max.16-Inch wide -99.25 CDX plywood Versashleld Solo 1800 seam with clips spaced 16 In.o.c. Min 15132 OPTIONAL Approved ASTM D 0.027,(0.7mm)Zinc DMC 15OSS DMC150SS Zinc attachment 150SS-W7 CDX plywood Verseshield Solo 1970 undedayment Max.15.74neh wide with 26 ga.DMC 150SS Fixed Clips spaced 40&5 180*seam 9 In,o.c. 15OSS-W8 Min.15/32 OPTIONAL 24 ga.DMC 150SS DMC 15OSS Continuous Butterfly CDX plywood Versashleld Solo As required per FBC Max.16-Inch wide attachment with fasteners spaced 12 In.o.c. 414.25 180*seam Min.15/32 OPTIONAL 24 ga.DMC 15OSS DMC 150SS Fixed Enhanced-90 15055-W9 CDX plywood Versashield Solo As required per FBC Max.16-inch wide attachment -150 Min.90'seam with clips spaced 12 In.o.c. Min.15/32 OPTIONAL 24 ga.DMC 150SS DMC 150SS Fixed Enhanced-180 ] 15OSS-W10 CDX plywood Versashield Solo As required per FBG Max.16-inch wide attachment 165 Min.180*seam with clips spaced 8 In.o.c. DRX15001.6 FL17678-R6 Page 3 of 8 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty,Installation,recommended use,or other product attributes that are not-specifically addressed herein. i s CREEK' `�D 1►E DREXEL METALS,INC. V i E K Metal Roofing TECHNICAL SERVICES,LLC 'APPENDIX B' Approved Systems for DMC 15058 over Wood Deck'(New or Existing), systeNo. Deck Deck Fire Banter Underlayment Roof Panel .` Panel Attachment �MDP.' I� Min.15132 OPTIONAL 0.03T Al DMC 150SS DMC 150SS Enhanced(At)attachment 150SS-W11 CDX plywood Versashietd Soto As required per FBC Max.164rich wide. -180 1800 seam with blips spabed 8 In.o c: Proved S terns for DMC 1755 over Steel Deck New or Existing) System.. . Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment' MDP No. .(lam Min.1 in.Approved 1758-S1 fin'22 ga' As required polyisocyanurate As required per FBC 24 9a:DMC 1 id DMC with clips #14 Standard attachment -60 Type B Steel Insulation board Max:18 inch wide - ' with clipsspaced 36 in.o.c. Min.1 In.Approved . Mln..22 ga. 0.040'AI DMC 1755 DMC 175S#14 Standard attachment 1755-S2 As requsred polyisocyanurate As required per FBC -88 - _Type B Steel insulation board Max.17.5-Inch wide with clips spaceihl8 in.o.c. Min.1 in.Approved Mln.22 ga. 24 ga DMC 1753 . DMC 175S#14'Standard attachment 175S-S3 As required poiyisocyanurate As required per FBC ` =105 Type B Steel insulation board Max.18-inch wide with clips spaced 6 in.o.c. Min.22-ga. Min.1 in.Approved 0.040"Al DMC 1755 DMC 175S#14 Standard attachment 175S-S4 Type B Steel As required potylsocyanurate As required per FBC 129.25 .insulation boats Max.17.5 inch wide with clips spaced 12 in.o.c. Approved'Systems'for DMC 175S'over Wood Deck(New or Existing) S Ntoem DP Deck Fire Barrier Underlayment Roof Panel_ :'( Panel Attachment p sQ OPTIONAL Min '15/32 0.032 Al DMC 175S DMC 175S#10 Standard attachment 1755-W1 Versashield As required per FSC -52.5 CDX plywood Sola _. Max.�1$-inch wide with clips spaced 24 in.a.c. OPTIONAL MIn.15132 0.032'AI DMC 1755 DMC 175S#10 Standard attachment 1755-W2 CDX plywood Versashiefd As required per FSC Max.1&inch wide with dips spaced 18 in.o.c. -59.4 Sola DRX15001.6 FL17678-R6 Page 4 of 8 This evaluation report is provided for State of Florida product approval under Rule 61020-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor Imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. i I 9"'TEcHNICAL CDriEEK DREXEL METALS,INC. Metal Roofing SEE2VICES,LLC APPENDIX B Approved Systems for DMC 1755 over Wood Deck(Now or Existing) System MDP No: Deck Fire Barrier Underlayment Roof Panel Panel Attachment- (Psi: OPTIONAL 175S--W3 Min.15132 Versashleld As required per FBC 0.032°AI DMC 175S DMC 175S#10 Standard attachment -66 4 CDX plywood Solo Max.IBArich wide with clips spaced 121n.o.c. Min.15132 OPTIONAL 0.032"AI DMC 175S DMC 175S#10 Standard attachment 1755 W4 Versashield As required per FBC -71 CDX plywood Soto Max.18-inch wide with clips spaced 8 in.o.c. Min.15132 OPTIONAL 0.032"AI DMC 175S DMC 175S#10 Enhanced attachment 175S-W5 CDX plywood Versashleld ld Approved ASTM D 1970 underiayment _ Max.118-Inch wide with clips spaced 12 in.o.c. -T1 � Solo - ASTM D 226,Type II roofing felt attached per Min.15132 1518.2.1 with nails and tin caps per 1517.5 0.032'At DMC 175S DMC 175S#10 Standard attachment 175S-W6 CDX plywood followed by Metshield High-Temp Max.18-inch wide with clips spaced 24 in.o.c. -74.75 Underlayment self-adhered to felt Min:15/32 OPTIONAL 0.032°AI DMC 175S DMC 175S#10 Standard attachment 1765 W7 CDX plywood Versashleld As required per FBC Max.14-inch wide with clips spaced 12 In.o.c. -82.5 Solo OPTIONAL Min.15/32 24 ga.DMC 1755 DMC 1755#10 Standard attachment 175S-W8 25 CDX plywood. VerSolo ld As requlred.per FBC Max.18-inch wide with clips spaced 16 in.o.c. " Solo Min.19/32 OPTIONAL 24 ga.DMC 1755 DMC 175S#10 Standard attachment 175S-W9 CDX' Verssashield As required per FBC Max.16-inch wide with clips spaced 25 In.o.c. -97.5 Min 15132 OPTIONAL 0.040"Al DMC 175S DMC 175S#10 Standard attachment Solo 1755-W10 CDX plywood Versashleld As required per FBC Solo Max.17.5-Inch wide with clips spaced 18 In.o.c. -106'75 ! OPTIONAL i Min.15/32 24 ga,DMC 175S DMC 175S#10 Standard attachment 1755-W11 CDX plywood VerSolo ld As required per FBC Max.18-inch wide with clips spaced 8 in.o.c. -121'75 _ Solo ASTM D 226,Type 11 roofing felt attached per Min.15/32 1518.2.1 with nails and tin caps per 1517.5 0.032°AI DMC 175S DMC 175S#10 Standard attachment 175S-W12 CDX plywood followed by Metshield High Temp Max.18-inch wide with clips spaced 6 in.o.c. -131 Underlayment self-adhered to felt Min.19/32 OPTIONAL 24 ga.DMC 175S DMC 175S#10 Standard attachment 175S W13 CDX plywood Versashleld As required per FBC Solo Max.16-inch wide with clips spaced 8 In.o.c. -135 DRX15001.6 FL17678-R6 Page 5 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G203. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein. I 3 DREL METALS,INC.CREEj Metal Roofing TF_CHNlCAL-SERVICES,LLC _ APPENDIX B A raved S erns far DMC 2005 over Steer Deck New or Ex sting) I System - MDP System Peck Fire Battier Insulation Undedayment Roof Panel Panel Attachment (psi Min.t in.Approved 24 ga.,DMC.2005 Min.22 ga. pp g 1 DMC 20t)S Butfertly(Steel)attachment j 2005-S1 As required � polyisocyanurate As required per FBC Max.16-Inch.wide -88 Type B Steel Insulation board 180'seam" with clips spaced 24 in.o.c_ 24 ga.DMC 2005, Min.22 ga. ;DMC 200S Butterfly(Steel)attabhment ' 200S-S2 As required _ None As required per FBC Max.16-inch wide -911.75 j Type B Steel 180,seamwith clips spaced 24 in.o.c. Min:1 In.Approved 24 ga.DMC 2005 200$-S3. Min,22 ga. As required polylsocyanurate As,required per FBC Max..16 Inch wide DMC 2005 Cah6nuous Bu(ferfTy(Sreel) _11211.75 Type B Steel 'insulatibn`board IW,seam- attachment with clips spaced 12.1n.o.c. 24 ga.DMC 2005 Min.22 ga. � DMC 2005 Continuous Butterfly(Steel) 200S-S4 Type B Steel As required None As required per FBC Max.16-Inch wide attachment with clips spaced 121n.o.c. -1511.75 180"seam Approved Systems for DMC 2005 over Wood.Deck(New or Existing) System Deck, Fire Barrier. Underiayment Roof Panel Panel Attachment Psi Min.15132 OPTIONAL 24 ga:DMC,200S DMC 200S Butterfly attachment 2005-W1 As required per FBC `Max.16-inch wide CDX plywood Versasti(eid Solo with dips spaced 24 in.o.c. - 180 seam •, . I Min.15132 OPTIONAL. 0.040'AI DMC 2005 DMC 2005 Butterfly attachment 20gSiW2 - As required per FBC Max.164noh wide 75 CDX plywood Versashield Solo " with clips.spaced 24 in.o.c. 180 seam 0.040'AI DMC 2005 2005 W3 Mtn.19/32 OPTIONAL As required per FBC Max:16-Inch wide DMC 2005Fixed atfachirient _105 CDX plywood , Verseshield Solo 180°seam y clips spaced 16 In.o.c. i 0.040"At DMC 2005 Min.19132 , OPTIONAL DMC 200S Fixed Enhanced attachment 200S-W4: As required per FBC Max.16 inch wide 480 CDX plywood , Versashield Sola 1800 seam wig clips spaced 8 in.o.c. DRX15001.6 FL17678-R6 Page 6 of 8 This evaluation report is provided far State of Florida product approval under Rule 61G20-3. The manufacturer shalt notify CREEK Technical Services,LLC of any product changes or quatity assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein. `FY CREEK DREXEL METALS,INC. ! Metal Roofing i TECHNICAL.SERVicEs,LLC . APPENDIX B Approved-Systems.for-DMC 45.0 over Wood Deck thew or Existing) System` Deck Fire Barrier ,Undedayment Roof Pane! Panel'Attachment ADP No: I (psfl Min:19/32. OPTIONAL 24 ga.DMG 450 DMC 450 Standard attachment 450-W1 As required per FBC .S0 - CDX plywood Versashleld Solo ,Max.16-Inch wide with clips spaced 24 In.o.c. f Min'15132, OPTIONAL 0.032°Al DMC 450 DMC 45OSS Standard attachment 450 W2 AS required per FBC ,45 CDX plywood Versashleld Sola _ Max.16-inch wtde with clips spaced 16 in.o.c. Min.19132 OPTIONAL 24 ga.DMC 450. -,. DMC 480 Standard attachment 450-W3 , CDX plywood Versashleld Solo As required per FBC Max.'16-inch wide with clips spacad 15:5 In."o.c. "67'5 Min.15132 OPTIONAL 0.032'Al DMG 450 DMC 45OSS Standard attachment 450-W4 As required per FBC 75 CDX plywood Versashleld Solo Max:16-inch wide with clips spaced 6,1n.o.c. 450-W5 Min.19132 OPTIONAL As required per FBC 24 ga.DMC 450 DMC 450 Standard attachment -82 5 CDX plywood- Versashield Sola Max.16-Inch wide with clips spaced 6 in.o.c. Approved Systems for DMC 5V over.Wood.Deck(New or Existing) System Fire Barrier/ MDP No. Deck Und6flayment Roof-Panel Panel Attachment (psf) Insulation OPTIONAL ASTM D 226,Type If rooting felt attached per 0.032",'Al DMC 5V DMC 511#10 Standard attachment Min.15/32 1518.2.1 with nails and tin caps par 1517.5. Min.21-inch to 5V W1 CDX plywood Approved fire barrier followed by Metshield High-Temp Max.244nch with HWH woad screws with -58 or insulation Underlayment sett-adhered to felt coverage seallinging washers spaced 18 in.o.c. 26 ga.DMC 5V DMC 5V Standard attachment Min.15132 OPTIONAL Min.21-Inch to 5V-W2 CDX plywood Approved tire taller __ As required per FBC Max 1-in Bch with#9-15 HWH wood screws with. -60 or insulation coverage sealing washers spaced 16 in.o.c. 1 OPTIONAL ASTM D 226,Type 11 roofing felt attached per 26 ga.DMC 5V DMC 511#10 Standard attachment Min.15/32 1518.2.1 with nails and On caps per 1517.5 Min.21-inch to SV-W3 CDX plywood Approved fico barrier or insulation fotiowed by Metshletd High-Temp- Max.24-inch with sealing washers HWH wood screws with -71 i spaced 24 in.a.c. i Underiayment self-adhered to felt coverage DRX15001.6 FL17678-R6 Page 7 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. 4 I r ry I JiCkEEKREXELS,I Metal INC. G TECHNICAL SERVICES,LLC APPENDIX B Approved Systems for DMC 5V over.Wood Deck New.or Existin - System!� l=ire Barrier! MDP. Deck UadeNayment Roof Panel- Panel Attachment No. Insulation. (psf) Min.7116 OSB OPTIONAL Min.21-inch to 26 ga.DMC 5V DMC 5V Pan Fastening attachment 6V W4 plywood Approved fire barrier As required per FBC Max.24-Inch coverage #1 -14 HWH wood screws with -75 or insulation coverage sealing washers spaced 16 In.o.c. OPTIONAL 26 ga.DMC 5V DMC 5V Pan Fastening attachment # 5V W5 Min. wo OSB Approved fire barrier As required per FBC Min.21-inch'to with#10-14 HWH wood screws with -112.5 { plywood or insulation Max.244nch sealing washers spaced 8 in.o.c. { coverage i OPTIONAL 26 ga.DMC 5V DMC 5V Standard attachment 5V-W6 Min.plywood Approved fire barrier As required per FBC Min.214nch to with#9-15 HWH wood screws with 421.75 CDX pllywood or insulation Max.24-inchsealingwashers spaced 8 in.o.c. coverage ASTM D 226,Type it roofing felt attached per 26 ga.DMC 5V or OPTIONAL p per 1517.5 0.032'Ai DMC 5V DMC 5V#10 Standard attachment CDX plywood Approved fire barrier Min.15132 1518.2.1 with nails and fin caps 5V-W7 followed by Metshield High-Temp Min.214nch to with#10-14 HWH wood screws with -206 or insulation Underlayment self-adhered to felt Max.24-Inch sealing washers spaced 6 in.o.c. coverage Approved Systems for DMC Corrugated over Wood Deck(New or Existing) System Fire Barrier/" MDP No. Deck Insulation Underlayment Roof Panel Panel Attachment (psf} OPTIONAL DMC 5V Corrugated attachment Min.i5t32 0.432"Ai DMC Corrugated COR-W 1 CDX plywood Approved fire barrier As required per FBC Max.21-inch coverage �h#10-15 HWH wood screws with dual Threads -60 or insulation and sealing washer spaced 36 in.o.c. Min.15132 OPTIONAL 26 ga.DMC Corrugated DMC 5V Corrugated attachment COR-W2 CDX plywood Approved fire barrier As required per FBC Max.27-inch coverage with#10-15 HWH wood screws with dual threads -60 or insulation and sealing washer spaced 361n.o.c. OPTIONAL DMC 5V Corrugated attachment CDX plywood COR-W3 Min' ywood Approved fire barrier As required per FBC 0.032"Ai DMC Corrugated with#10-15 HWH wood screws with dual threads -135 or insulation M 21-inch coverage and sealing washer spaced 12 in.o.c. Min.15132 OPTIONAL 26 ga.DMC Corrugated DMC 5V Corrugated attachment COR-W4 CDX plywood Approved fire barrier As required per FBC Max.214nch coverage with#10-15 HWH wood screws with dual threads -150 or insulation and sealing washer spaced 12 in.o.c. DRX15001.6 FL17678-R6 Page 8 of 8 This evaluation report Is provided for State of Florida product approvai under Rule 61020-3. The manufacturer shall notify CREEK Technical Services,LEC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. I I I F DREXEL METALS,INC. 5..,4 CREED{ Metal Roofing TECHNICAL SERvICEs, LLC APPENDIX C DESIGN WIND LOADS The following tables provide design wind loads for components and cladding in accordance with Section 1609 of the FBC and ASCE 7-10 under the following provisions: 1. For Flip roofs between 2:12 and5.6:12,Zone 3 shall be treated as Zone 2. 2. Wind speeds for risk category I,II,III,and IV buildings shall be as defined in Section 1609 of the FBC. 3. Exposure B,C,and A shall be as defined in section 1609 of the FBC. 4. Design wind load provided only for gablelhip roofs with roof slopes between 2:12 and 6.1:12 5. All calculations are based on an effective wind area of 10-fe or less. 6. Topographic factors such as escarpments or hills have been excluded from the analysis 7. Overhangs have been excluded-from the analysis. 8. Wind directionality factor,Kd=0.85 9. Wit is shown in the tables below.Design wind loads are calculated using Vwd=V„140.6 per 1609.3.1. 10. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional 11. Zones 1,2,and 3 shall be defined as shown below. Dimension°a'shall be 10%of the least horizontal dimension or{0.4 x Mean Roof Height),whichever is smaller,but not less than either 4%of the least horizontal dimension or 3ft Gable - Hip N a _ 3 2 3 3 2 3 a 3 2 0 a i 2 1 2 2 1 i2 2 1 2 2 1 2 II I i i 1 1 2 H3 3 2 3 a 2 3 I a lal lalal a lal lal DRX15001.6 FL17678-R6 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,Installation,recommended use,or other product attributes that are not specifically addressed herein. f DREXEL METALS,INC. z Y CREEK Metal Roofing TECHNICAL,SERVICES,LLC APPENDIX C Gabletk FZoafs"in ure'B.(Roof between 2.12.and Building. - Mean- BasicVl►ind S eed m ;.. Type Zone Roof. 120 140 150. 16b- 170 180 190 206 -. Hei ht ft 20 -14.2 -16.7 -19.3 -22.2 -25.3 -28.5 -32.0 -35.6 -39.5 25 -14.2 -16.7 -19.3 " -22.2.. -25.3 28.5 -32.0 -3566- 29.5 1 30 -14.2 -16.7 -19.3 --22.2 -25.3. -28.5 -320'" -35.6 -39.5 40 -15A -18.1 -21.0 -24.1 -27.4 -31.0 -34.7 -38.7 -42.9 50 -16.5 -19.3 -22.4. -25.7 -29.2 -33,0 -37.0 -41.2 -45.7 60 =17.3 -20.3 -23.5" -27.0 -30.7 -34:6 _ -38.8 -43.3 -47.9 20 -24.7 29.0 -33,7 -38.7 -44.0 49.7 -55.7 -62.0 -68.7 25 24.7• 29.0 -33.7 -38.7 44.0 49.7 -55.7 -620 -68.7 Enclosed -2 30 24.7 29.0 -33.7 -38.7 -44.0 49.7 -55.7 -620 -68.7 40 -26.9 21.5 -36.6 42.0 -47.8 -53.9 -60.4 -67.3 -74.6 50 -28.6 -33.6 •39A 44.T.- -50.9 -57.5 =64.4 71.8 -79.5 60 -30.0 -35.3 -40.9 -46.9 -514 -60.3 -67.6 -75.3 :83:5 20 -36.6 -42.9 49,8 -57.2 -65.0 -73.4 -82.3 -91.7 -101.6 25 -36.6 -42.9 49.8 -57.2 -65.0 -73.4 -82.3 -91.7 -101:6 3 30 -36.6 112.9 -49.8 -57.2 -65.0 73.4 -82.3 -91.7 -101.6 40 49.7 46.6 --54.1 -62.1 -70.6 -79.7 -69.4 -99.6 -110.3 50 -42.3 149.7 -57.6 -66.2 -75.3 -85.0 -95.3 -106.1 -117.6 60 44:4 --52.1 -60.5 -69.4 -79.0 -89.2 -100.0 -111.4 -123A 20 -19.1 22.4' -26.0 -29.8 - -33.9 -38.3 -42.9 -47.8 -53.0 25 -19.1 -22A -26.0 -29.8 -33.9 -38.3 _ -42.9 -47.8 -53.0 1 30 -19.1 -22.4 -26.0 -29:8 -33.9 -38.3 -42.9 -47.8 -53.0- 40 -20.7 -24.3 -28.2 .32.4 26.8 -41.6 -46.6 -51.9 -57.6 50 -22.1 25.9 - -30.1 :34.5 -39.3 -44.3 -49.7 -55.4 61.3 60 -23.2 27.2 21.5 -36.2- -41.2 -46.5 -52.1 -56.1 -64.4 20 -29.6 -34.8 -40.3 -46.3 -52.6 -59.4 -66.6 -74.2 -82.3 25 -29.6 -34.8 -40.3 -46.3 -52.6 -59.4 -66,6 -74.2 -82.3 Partially - 30 -29.6 -34.8 -40.3 -46.3 -52.6 59.4 -66.6 -74.2 ,-82.3 Enclosed 2 40 -32.2 -37.7 -43.8 -50.2 -57.2 -64.5 72.3 -80.6 -89.3 50 -34.3 -40.2 -46.6 -53.5 - -60.9 -68.8 77.1 -85.9 -95.2 60 -36.0 -42.2- 148.9 -56.2 -63.9 72.2 ' -80.9 -90.1 -99.9 20 -41.5 -48.7 -56.4 -64.8 -73.7 -83.2 -93.3 -103.9 -115.2 25 -41.5 -48.7 -56.4 -64.8 -73.7 -83.2 -93.3 -103.9 -115.2 3 30 -41.5 -48.7 -56.4 -64.8 -73.7 -83.2 -93.3 -103.9 -115.2 40 -45.0 •52.8 -61.3 70.3 -80.0 -90.3 -101.3 -112.8 -125-0 50 -48.0 -56.3 -65.3 -75.0 -85.3 -96.3 -107.9 -120.3 -133.3 60 -50.3 -59.1 -68.5 -78.7 -89.5 -101.0 -113.3 -126.2 -139.8 DRX15001.6 FL17678-R6 Page 2 of 4 This evaluation report is provided for State'of Florida product approval under Rule 61C20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. i }I I y CREEK D��LMETALS, ofing TECHNICAL SERVICES,LLC APPENDIX G Gable/t11Roofs In txposuie C f oaf:slope between 2:92 and 6.1;12 Building Mean i3asib Wirid Speed.(Mph)' -Roof oof Type • H tit ft 120 180 1'40 '150.,.. 160. 170 _. 180. .. 190 :200 20 -18.3 -21.4 -24,9 -28.6 52.5 -36.7 -41.1 -45.8 -50.8 25 -19.1 -22.4 -26.0 -29.8 -33.9 -38.3 -42.9 -47.9 -53.0 30 -19.9 -23.4 -27.1 -31.1 -35.4 -39.9 -44.6 -49.9 -55.3 1 40 -21.1 24.8 1 -28.7 -33.0 -37.5 -42.4 -47.5 -52..9 -56.7 50 -22.1 -26.0 -30.1 -34.6 -39.4 44.4 49.8 -55.5 -61.5 60 -22.9 -26.9 -31.2 -35-9- -40.8 -46.1 51.6 -57.5 -63.7 20 -31.8 -37.3 43.3 -49.7 -56.6 -63.8 -71.6 -79.8 -8&4' 25 88.4- 25 -33.2 -39.0 45.2 51.9 -59.1 -66.7 74.8 -83.3 -92.3 Enclosed 2 30 -34.6 40.7 -47.2 -54.1 -61.6 -69.5 77.9 -86.8 -96.2. 40 -36.8 -43.1 -50.0 -57.4 55.4 -73.8 •82.7 -92.2 402.1 50 -38.5 -45.2 -52.4 -60.2 -68.5 -77.3 -86.7 -96-6 -107.0 60 -39.9 -46.9 -54.4 -62:4 -71.0 -80.2 -89.9 -100.1 -111.0 20 -47.0 -55,2 -64.0 -73.5 -83.6 -94.4 -105,8 -117.9 -130.7 25 -49.1 -57.7 -66.9 -76.8 -87.3 -9$.6 -110.5 -123.2 -136.5 3 30 -512 -60.1 -69.7 -80.0 -91.1 -102.8 -115.3 -128.4 -142.3 40 -54.4 -63.8 - -74.0 -84.9 -96.6 -109.1 -122.3 -136.3 -151.0 50 57.0 -66.9 -77.5- -89.0 -101.3 -114.3 -128.2 -142.8 -158.3 60 -59.1 -69.3 -80.4 -92.3 -105.0 -118.5 -132.9 -148.1 -164.1 20 -24.5 28.8 -33.4 -38.3 -43.6 -49.2 -55.2 -61.5 -68.2 25 -25.6 50.1 -34.9 -40.0 -45.6 -51A -57.7 54'.2 -71.2 1 30 -26.7' -31.4 -36.4 -41.7 -47.5 -53.6 -60.1 -67.0 -74.2 40 28.4 53.3 -38.6 -44.3 -50.4 -56.9 -63.8 -71.1 -78.8 50 29.7 -34.9 -40.5 -46.4 -52.8 -59.6 -66.9 -74.5 -82.5 60 -30.8 56.2 -41.9 -48.1 -54.8 -61.8 -69.3 -77.2 -85.6 20 -38.1 -44.7 -51.8 -59.5 -67.7 -76.4 -85.7 -95.4 -105.8 25 -39.8 46.7 -54.1 -62.1 -70.7 -79.8 -89.5 -99.7 -110.5 Partially 30 -41.5 -48.7 56.4 54.8 -73.7 -832 -93.3 -103.9 -116.2 Enclosed 2 40 44.0 -51.6 -59.9 58.7 -78.2 -88.3 -99.0 -110.3 -122.2 50 -46.1 -54.1 -62.8 -72.0 -82.0 -92.5 -103.8 -115.6 -128.1 60 47.8 56.1 1 -65.1- -74.7 -85.0 -95.9 -107.6 -119.8 -132.8 20 53.3 -62.6 -72.6 -83.3 -94.8 -107.0 -119.9 -133.6 -148.1 25 -55.7' -65.3 -75.8 -87.0 -99.0 -111.7 -125.3 -139.6 -154.6 3 30 -58.0 -68.1 79.0 -90.7 -103.2 -116.5 -130,6 -145.5 . -161.2 40 -61.6 -72.3 -83.8 -96.2 -109.5 -123.6 -138.6 -154.4 -171.1 50 -64.6 75.8 -87,9 -100.9 -114.8 -129.6 -1452 -161.8 -179.3 60 1 -66.9 -78.5 -91.1 A04.6 -119.0 . -134.3 -150.6 -167.8 -185.9 i DRX15001.6 FL1767"6 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G205. The manufacturer shalt notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. w CREEK DREXEL METALS,INC. R K Metal Roofing TEcHNiCAL SERVICES,LLC APPENDIX Cy t;atrfeltii Aoofs'iri Ex "ante D.Rodf.slo"e t�etween'2:12 and 6.1:12: "• . 6ui}itipiten '... - isind S mph)' 'Bas 9- - T . .T . .,: .. Zone He'R�(ft 130 144 154. '166 170 1$0 :790 200. j 20 -21.9 -25.7 -29.9 -34.3 -39.0 -44,0 -19.3 55.0 -60.9 i 25 -22.7 -26.7 -31.0 -35.5 40.4 -45.6 -51.2 -57.0 -63.2 1 30 -23.6 -27.6 -32.1 -36.8 41.9 -47.3 -53.0 -59.1 -65.4 i 40 24.8 29.1 -33.7 -38.7 -44.4 49.7 -55.7 -62.1 -68.8 50 25.8 -30.3 -35.1 40.3 -46.9 -51.8 -58.0 -64.6 1 -71.6 60 -26.6 -31.2 -36.2 41.6 -47.3 -53.4 -59.9 -66.7 73.9 20 -38.2 -44.8 -52.0 -59.7 -67.9 -76.6 -85.9 -85.7 -106.0 25 -39.6 46.5 -53.9 -61.9 -74.4 -79.5 -89.1 -99.2 -110.0 Enclosed 2 30 -41.0 -48.1 -55.8 -64.1 -72.9 -82.3 -92.3 -102.8 -113.9 40 43.1 50.6 -58.7 -67.4 -76.7 -86.5 -97.0 -108.1 -119.8 i 50 44.9 52.7 -61.1 -70.1 -79.8 -90.1 -101.0 -112.5 -124.7 60 -46.3 54.3 -63.0 -72.4 -82.3 -92.9 -104.2 -116.1 -128.6 20 -56.5 -66,3 -76.8 -88.2 -100.4 -113.3 -127.0 -141.5 -156.8 25 -58.5 -68.7 -79.7 -91.5 -104.1 -117.5 -131,7 -146.8 -162.6 3 30 -60.6 -71.2 -82.5 -94.7 -107.8 -121.7 -136.4 -152.0 -168A 40 -63.8 74.8 -86.8 -99.6 -113.4 -128.0 -143.5 -159.9 -177.1 50 -66.4 77.9 -90,4 -103.7 -118.0 -133.2 -149.4 -166.4 -184.4 60 -68.5 50A -93.2 -107.0 -121.7 -137.4 -154.1 -171.7 -190.2 20 -29.4 -34.6 40.1 -46.0 -52.3 -59,1 -66.3 -73.8 -81,8 25 -30.5 -35.8 -41.6 47.7 -54.3 -61.3 -68.7 -76.5 -84.8 1 30 -31.6 27.1 -43.0 -49.4 -56.2 -63.5 71.2 -79.3 -87.8 40 -33.3 -39.0 -45.3 -52.0 -59.1 -66.8 74.8 -83.4 -92.4 50 -34.6 -00.6 -47.1 -54.1 -61.6 -69.5 -77.9 -86.8 -962 60 -35.7 -41.9. -48.6 -55.8 -63.5 -71.7 -80.4 -89.5 -99.2 20 -45.7 -53.6 -62,2 -71.4 -81.2 -91.7 -102.8 -114.5 -126.9 25 47.4 -55.6 -64.5 -74.0 -84.2 -95,1 -106.6 -118.8 -131.6 Partially 2 30 -49.1 57.6 -66.8 -76.7 -87.2 -98.5 -110.4 -123.0 -136.3 Enclosed 40 -51.6 -60.6 -70.2 -80.6 -91.8 -103.6 -116.1 -129.4 -143.4 50 -53.7 53.1 -73.1 -83.9 -95.5 -107.8 -120.9 -134.7 -149.2 60 -55.4 -65.0 -75.4 -86.6 -98.5 -111.2 -124.7 -138.9 -153,9 I' 20 -64.0 75.1 -87.1 -99.9 -113.7 -128A -143.9 -160,3 -177.7 I 25 -66.3 -77.8 -90.3 -103.6 -117.9 -133.1 -149.2 -166.3 -184.3 3 30 -68.7 -80.6 -93.5 -107.3 -122.1 -137.9 -154.6 -172,2 -190.8 40 -•72.3 -84.8 -98,3 -112.9 -128.5 -145.0 -162.6 -181,1 -200.7 50 -75.2 -88.3 -102A -117.5 -133.7 -151.0 -169.2 -188.6 -208.9 60 -77.6 -91A -105.6 -121.2 1 -137.9 -155.7 -174.6 -194.5 -215.5 ! DRX15001.6 FL17678-116 Page 4 of 4 This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor Imply warranty,installation,recommended use,or other product attributes that are not speclftcally addressed herein,