Loading...
HomeMy WebLinkAboutProduct Approval (2) 5/17/2019 Florida Building Code Online SCIS Home Log In ? User Registration it Hot Topics i Submit Surcharge I Stats&Facts Publications Contact Us BCIS Site Map Links search FI lila ra Product Approval ,D USER.Public User (D g, Product Aooroval Menu>Product or Applirat on Search>@pnlicatlon Llst>Application Detail d pCP� fflFL# FL15216-R4''` Application Type Revision Code Version 2017 �L�3m Application Status Approved Comments Archived Product Manufacturer Owens Coming Roofing and Asphalt,LLC Address/Phone/Email One Owens Corning Parkway Toledo,OH 43645� � ® � (740)321-6345 Greg.Keeler@owenscorning.com Authorized Signature Keeler Greg Greg.Keeler@owenscorE,liglg%y�F—WF—D IF®R Technical Representative Greg Keeler C®DE C VVOVVMPUANCE Address/Phone/Email Columbus Ro Grenville, n Fl h ME C®1�K N Granville,OH 4302 E�141J (740)321-6345 [� greg.keeier@owenscorning.com B00C Quality Assurance Representative Address/Phone/Emall Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity Intertek Testing Services NA,Inc.-QA Entity Quality Assurance Contract Expiration Date 12/31/2020 Validated By John W.Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FLIS216 R4 COI 2018 01 COI NIEMINEN.udf Referenced Standard and Year(of Standard) Standard Year ASTM D1970(tear) 2015 ASTM D226(physicals) 2009 TAS 117(8) 1995 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabullding.org/pr/pr app_dtl.aspx?param=wGEVXQvADgv3yVVKJZIQRAdhyt2u8kQGvTebw8)dQgg%2bDZLSJPcQRg%3d%3d 112 5/17/2018 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 04/20/2018 Date Validated 04/20/2018 Date Pending FBC Approval 04/22/2018 Date Approved 06/12/2018 Date Revised 04/19/2019 Summary of Products FL# Abdel,Number or Name Description 15216.1 RhinoRoof Underlayments Synthetic roof undedayments Limits of Use Installation Instructions Approved for use in HVHZt Na Ft 1 216 R4 II 2018 04 FINAL ER OWENS Approved for use outside HVHZt Yes CORNING RHINOROOF FL15216-R4 odf Impact Resistant;N/A Verified By: Robert Nieminen PE-59166 Design Pressure, N/A Created by Independent Third Party:Yes other.See ER Section 5 for Limits of Use. Evaluation Reports FLIS216 R4 AE 2011 04 FINAL ER OWENS CORNING RHINOROOF FL15216-R4 Ddf Created by Independent Third Party:Yes Contact Us;;2601 81air.Stone Road,Tallahassee FL 32399 E112=30:4 The State of Florida is an AgtEEO employer.Qht 2007-2013 Stagg of F3ortda.::tb=State nt::4,_ctesstbIlU Statement:t Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditlbnal mail.if you have any questions,please contact 850.467.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,FS-must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public,-To determine If you are a licensee under Chapter 455,F S.,please cockrte. Product Approval Accepts; Credit Card Safi!-. https:liwww.floridabuilding.org/prlpr app dQ.aspx?param=wGEVXQwtDgv3yWKJZlQRAdhyl2u8kQGvTebw8xlQgg%2bDZLSJPcQRga/o3d%3d 2/2 NEMO etc. Certificate ofAuthorization#32455 353 Christian Street,Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY REPORTEVALUATION Owens Corning Roofing and Asphalt,LLC Evaluation Report 140530.02.12-R4 One Owens Corning Parkway FL15216-114 Toledo,ON 43659 Date of issuance:02/17/2012 (740)321-6345 Revision 4:04/19/2018 SCOPE: This Evaluation Report is issued sander Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 61' Edition (2017) Florida Building Code sections noted herein. DEscRiP,nON: RhinoRoof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE:This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s),the Quality Assurance or the production facility location(s). MEMO Jetc.requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded by the words "NEMO J etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report Is displayed,then it shall be done in its entirety. INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 3. Prepared by: a`\ }}ygnr+y,„fri Robert J.M.Nleminen P.E. y='�`�•R ”; r�Qa 'c r The facsimile seal appearingwas authorizedbyRobert Florida Registration iVo.59166,Florida DCA ANE1983 :1{ti„�,�,,,,,.: Nleminen,P.E.on 04/19/Z018.This does not serve as an electronically signed document. CEWIFICATION OF INDEPENDENCE: 1. NEW ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nleminen,P.E.does not have,nor will acquire,a financial interest In any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMO Ietc. nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. O. NEMOJetc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: RhinoRoof Underlayments,as produced by Owens Corning Roofing and Asphalt,LLC,has demonstrated compliance with the following sections of the 6u'Edition(2017)Florida Building Code through testing in accordance with applicable sections of the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. '5ectfotr.STANDARDS: Properties ' 5tanda'rd'. Year. 1507.1.1,R905.1.1 Exception Unrolling,Breaking Strength,Pliability ASTM D226' 2009 1507.1.1,R905.1.1 Exception Tear Strength ASTM D1970 2015 TAS 110 Pull-through resistance TAS 117(6) 1995 3. REFERENCES: Ent Examination. Reference' Date; ITS(TST1509) Physical Properties 100539395COQ-006 10/27/2011 ITS(TST1509) Physical Properties 100539395COQ-002 10/27/2011 ITS(TST1S09) Physical Properties 10DS39395COQ-006 03/14/2014 PRI(T5T5878) ASTM D1970;Tear strength OCF-330-02-02 10/03/2017 PRI(TSTS878) TAS 117(8);Pull-through OCF-422-02-01 04/03/2018 ITS(QUA1673) Quality Control Service Confirmation 09/30/2017 PRODUCT4. r • 4.1 RhlnoRoof U20 is a multilayered polymer woven coated synthetic roof underlayment available in 42-inch wide rolls, and can be produced in various other sizes;meets FBC 1507.1.1&R905.1.1(Exception). 5. 5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nleminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory or test report from accredited testing agency for fire ratings of this product. 5.4 RhinoRoof Underlayments may be used with any prepared roof cover where the product Is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE 1: ROOF COVEROPTIONS Underiayment Asphalt Waod Shalpes Slate or Shingles Nall-On Tile FOAM-On Tile Metal: kslh glen Sirrruiated State i Rh noRaof U20 . Yes .,N •. :htir 5.6 Exposure Limitations: RhinoRoof U20 shall not be left exposed for longer than 30-days after installation. MEMO ETC,LLC Evaluation Report 140510.02.12-R4 Certrftcate of AuthorIzadon#32455 fico EDITION(2017)FBC NON-HVH2 EVALUATION FL15216-114 RhlnoRoof Underlayments Revision 4:04/19/2018 Page 2 of 4 ONiEMO etc. 6.__ INSTALLATION: 6.1 RhinoRoof Underlayments shall be installed in accordance with Owens Corning Roofing and Asphalt, LLC published installation instructions subject to the Limitations set forth in Section S herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check foe protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. 6.3 RhirtoRogf U20:7 6.3.1 Shall be installed in compliance with the requirements for ASTM D226,Type i or it underlayment in FBC Table 1507.1.1 or 8905.1.1 for the type of prepared roof covering to be installed,taking into account the wider sheet- width. 6.3.2 Fasteners: For exposure<24 hours,corrosion resistant fasteners may be 1-inch roofing nails with a 3/8-Inch diameter head, minimum 1-inch diameter plastic or metal cap nails or FBC HVHZ nails&1-5/8"diameter tin caps(with the rough edge facing up). The use of staples Is prohibited. For exposure>24 hours up to maximum 30 days,corrosion resistant fasteners shall be minimum 1-inch diameter plastic or metal cap nails or FBC HVHZ nails&1-5/8"diameter tin caps(with the rough edge facing up). The use of staples is prohibited. 6.3.2.1 Code Reference: The Exception statement in FBC 1507.1.1 and FOC R905.1.1 states: "...except metal cap nails shall be required where the ultimate design wind speed, V„rt,equals or exceeds 150 mph." Owens Corning Roofing and Asphalt,LLC has furnished data to permit the use of 1-Inch diameter plastic cap nails in lieu of metal cap nails for these applications, when the RhinoRoof U20 underlayment is installed beneath mechanically fastened prepared roof covers referenced in FBC Table 1507.1.1 or R905.1.1. 6.3.3 Sinele Laver:Roof Slope>4:12: End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. Refer to Owens Coming Roofing and Asphalt, LLC recommendations for alternate lap configurations and/or the use of sealant under certain conditions. For exposure<24 hours,use of every-other fastening location printed on the surface is acceptable. For exposure >24 hours up to maximum 30-days,use of every fastening location printed on the surface is required. When batten systems are to be Installed atop the underlayment,the underlayment need only be preliminarily attached pending attachment of the battens on the same day. Battens shall not be positioned over cap nails. If this occurs,remove the cap nail and patch the hole in accordance with Owens Corning Roofing-and Asphalt, LLC published instructions. 6.3.4 Double Laver:2:12<Roof Slooe<4:12: End (vertical)laps shall be minimum 12-inches and side(horizontal)laps shall be minimum half-sheet-width plus 1-inch. Double layer application, begin by fastening a half-width plus 1-inch starter strip along the eaves. Place a full- width sheet over the starter, completely overlapping the starter course. 'Continue as noted in 6.3.3, but maintaining minimum half-width plus 1-Inch side(horizontal)laps,resulting In a double-layer application. MEMO ETC,LLC Evaluation Report t4o51#1.02.12-R4 Certificate of Authortzatlan#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION 1 FL15216-R4 Rhinopoof llnderlayments Revision 4:04119/2015 Page 3 of 4 "NEM0 I etc.- 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING • , Qingdao,China 9. QUALITY ASSURANCE ENTITY: Intertek Testing Services NA Inc.—QUA1673;(608)836-4400 END OF EVALUATION REPORT- NEMO ETC,LLC Evaluation Report 140510.02.12-114 CertU7cvte of Authorization#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL15216-R4 RhinoRoof Underlayments Revision 4-.04119/2018 Page 4 of 4