Fl.d! FL5259-1128
Application Type Revision
Cade Version - 2017
Application Status Approved
Comments
Archived ❑
Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W.Newport Center Drive
Deerfield Beach,FL 33442
(954)233-1330 Ent 242
malpett@polyglass.com
Authorized Signature Maury Alpert
malpert®polyglass.com
Technical Representative Maury Alpert
Address/Phone/Small 1111 W.Newport Center Drive
Deerfield Beach,FL 33442
(912)429-8610
MAfpert@polyglass.com
Quality Assurance Representative Adel Lender
Address/Phone/Emall 1111 W.Newport Center Drive
Deerfield Beach,FL 33442
(954)233-1230
ALendergpDlyglass.com
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nleminen
the Evaluation Report
Florida License PE-59165
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 09/13/2021
Validated By John W.Knezevlch,PE
21 Validation Checklist-Hardcopy Received
Certificate of Independence EL5259 R28 CO; 2018 01 C01 NIEMINEN.Ddf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM.D226 2009
ASTM D4798 2011
ASTM 06164 2011
ASTM D6222 2011
i FM 4474 2011
FRSArrRI April 2012 2012
UL 1897 2012
;y tos: c,
I
I
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method'I Option D
Date Submitted 01/24/2018
Date Validated 01/29/2018
Date Pending FBC Approval 01/30/2018
Date Approved 04/10/2018
ftnunary of l raducta
FL# Model,Number or Name Description
5259.1 Polyglass Roof Roofing.underlayments
Underlayments
Limos of Use Installation Instructions
Approved for use in HVHZ:No B-5259 R28 II 2018 01 I-INAL ER POLYGLASS UNOERLAYMENTS FL5259-
Approved for use outside HVHZ:Yes R28,z)d
Impact Resistant:N/A verified By:Robert Nleminen PE-59166
Design Paresliure.+N/A/-622.5 Created by Independent Third Party:Yes
Other,1.)The design pressure In this B'valuatlon Reports
application relates to One particular E 5 259 R28 AE 2018 01 FINAL ER POLY(5LASS UNDERLAYMEN•rS FL5259-
underlayment system(over concrete deck) $28,nd
for use under tbam-bn the systems(where Created by Independent Third Party:Yes
the underlayment towns part of the load-
path).Refer to ER Section 5.6.4 for other
systems,other deck types and associated
maximum design pressures.2.)Refer to ER
Section 5 for other limits of use.
- ContaC�::2601 Blair StP-ileum.TSlla..:_.an A aY,aa Phenlr 856-C82-1874
The State of Florida is an AAXW employer.c_••f!aM2007-201 tea..+ofFlerlda.:;Privacy Statement is Acma bilev Sttrtement;;ReNnd Statement
Under Fforfda few,emit addresses ate public mcards.If you do not want yoare nm0 address tdeased in response to a pubAo-records raquasp do aotsead aleetrorlic
mall to this entity•instead,contact the offlm by phone or by tradlUonal matt If you new any euesdans,place:contact 850.487.1395.*Pursuant to Seeelon 455.275(l),
Roma Statutes,dyeable Ordaber 1,20I2,licensees licensed under Chaptec45%F.S.must provide the Departmentvilth an email address uthey have une.The malls
provided maybe used mr offlclai communication with the 0lenSm However entall addlemrr ate public recatd..If you do not wish to supply a personal address,pease
provide the Department whh an email address which can be made available to the public.To determine It you area Ileems under Chapter 455,F.S.,please deck eh K.
Product Approval Ateeptr
®®MERE
Credit Card
Safe
i
MEMO f etc.
cemjlcote OfAutharizdtloa 53245S
353 Christian Street,Unit#13
I Oxford,CT 06478
(203)262-9245
IENGINEER EVALUATE TEST CONSULT CERTIFY
EVALUATION REPORT
Polyglass USA,Inc. Evaluation Report P12060.02.09-1124
1111 West Newport Center Drive FLS259-R28
Deerfield Beach,FL 33442 Date of issuance:02/24/2009.-
(954)233-1230 Revision 24.01/24/2028
SCOPE:
i
This Evaluation Report is issued under Rule 6162" and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed•by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6u' Edition-(2017) Florida Building Code sections noted
herein.
f -
DEscRIPnom Polyglass Roof Underlayments
WEuNG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to-the
praduct(s),the Quality Assurance or the production facility lotation(s). NEMOIetc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADvERTisEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by: �� q,,,n
Robert J.M.Nieminen,P.E.
a op,a;.••r or4;= The facsimile seal appearingwas authorized by Robert Nieminen,
Florida Registration No.59166,Florida ACA ANE2983 14A,41;'°.c�^ .qf P.E.on oi/24/2016.This does not serve as an electronically
•:'fy��tp�LA�uir. .
+� signed document'
CUMIaCATiON OF INDEPENDENCE:
1. NEM61 etc. does not have,nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEW I etc is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial Interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,.a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NEMOI etc.nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
!
I
i
WNEMOletc.
ROORNG COMPONENT'EVALUATioN:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underiayment
Compliance Statemerd- Roof Underlayments,as produced by Potyglass USA, inc., have demonstrated compliance with the
following sections Of the 61h Edition(2017)Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard year
1504.3.1 Wind Uplift FM 4474 2011
1504.3A Wind Uplift UL 1897- 2012
1507.2.3/1507.1.1 Physical Properties ASTM D226 2009
1507,2.4/1507.11,1507.2.9.2 Physical Properties ASTM'01970 2015
1507,3.8 Physical Properties FRSA/TRI April 2012 2012
1507.12.2 Physical Properties ASTM D6164 2011
1507,11,2 Physical Properties ASTM D6222 2011
TAS 110 Accelerated Weathering ASTM D4798 • 2011
3. REFERENCEs:
Entity, Examination Reference Date
FM Approvals(TST 1867) Wind Uplift 3004091 01/12/2000
PRI(TST5878) Physical Properties PRIO2211 04/08/20M
PRI(75T 5878) Physlcal.Properties PUSA-005-02-01 01/31/2002
PRI(TSr 5878) Physical Properties PUSH 023-02-01 12/23/2002
PRI(TSTS878) Physical Properties PUSA-013-02-02 12/23/2002
PRI Cry 5878) Physical Properties PUSA-013-02-03 12/23/2002
PRI(TST5878) Physical Properties PUSA 018-02-01 07/14/2003
PRi(TST5878) Physical Properties PUSA-028-02-01 07/1312005
PRI(W5878) Physical Properties PUSA-033-02-01 01/12/2006
PRI M75878) Physical Properties . PUSA-035-02-01 09/29/2006
PRi(r5T'5979) Physical Properties PUSA-055-02-02 12/10/2007
PRI(TST 5878), Physical Properties PUSArOS"2-02 01/28/2008 .
PRI(75T5878) Physical Properties PUSA-076-02-01 02/22/2008
PRI tWS878) Physical Properties PUSA-083-02-0i 04/14/2008
PRI(TST 5878) Physical Properties PUSH-088-02-01 07/29/2009
MTI(TST 2508) Physical Properties 1X20H7A 04/01/2008
MTI(TST 2508) Physical Properties RX14EBA 02/29/2009
ERD(TST 6049) Physical Properties 11752.09.99-1 02/08/2000
ERD(TST 6049) Wind Uplift 11757.08.01-1 08/13/2001
ERD(TST 6049) Wind Uplift 11776.06.02 OV16/2003
ERD(TST 6049) Physical Properties 02200,07.03 07/14/2003
ERD(751'6049) Wind Uplift P1740.01.07 01/04/2007
ERD(i5T 6049) Physical Properties P5110.04.07-1 04/11/2007
ERD(T51'6049) Wind Uplift P9260.03.08 03/21/2008
ERD(TST6049) Physical Properties P13450.08.09 08/13/2009
ERD(TST6049) Wind Uplift P30540.11.09-R3 il/30/2009
ERD(TST 6049) Physical Properties P13030.11,09-1 11/30/2009
ERD(M 6049) Wind Uplift P12030.11,09-2 11/30/2009
ERD(TST 6049) Physical Properties P1103(L11.09-3 12/30/2009
ERD MT 6049) Physical Properties P33360.06.10 06/25/2010
ERD W6049) Physical Properties P33370.03,11 03/02/20U
ERD(TST 6049) Physical Properties P33370.04.11 04/26/2011
ERD(TST 6049) Physical Properties P37300.10.11 10/29/2011
NEMO ETC,LLC. Evaluation Report P12060.02A9-1124
CertiRmoe QfAutharimttOn#32455 fim EDITION 1=17)FBC NON-HVHZ EVALUATION R5259-R28
Potygtass Roof Underlayments,(954)233-1230 Revision 24:01/24/2018
Page 2 of 14
I
I
I
_ I
I
WNEMOletc.
Entiiv Examination. Reference Date
ERD(TST6049) Physical Properties P40390.08.12-1 08/06/2012
ERD(TST 6049) Physical Properties P4039MUS.12-2 08/07/2012
ERD W6049) Physical Properties C41420.09.12-3 09/11/2012
ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013
ERD(TST6049) Physical Properties P45370.04.13 04/26/2013
ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013
ERD(T5r6049) Wind Uplift 11757.04.01-1-Ri 04/30/2013
ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013
ERD(TST 6049) Wind Uplift P11751.05.03-RZ 11/26/2013
ERD(TST 6049) Wind Uplift P117BLIL03-RI 11/26/2013
ERD OW 6049) Physical Properties P45270.05.14 05/12/2014
ERD(TST 6049) Physical Properties 6020.07.14-1 09/08/2014
ERD(T517 6049) Physical Properties 6020.09.24-2 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-3 09/08/2024
ERD"r 6049) Physical Properties 6020.09.14-4 09/08/2014
ERD(TST 6049) Physical Properties 60200.09.24-5 09/08/2014
ERD(W 6049) Physical Properties 6020.09.14-6 09/08/2014
ERD(TST 6049) Physical Properties P46520.10.14 10/03/2014
ERD(TST 6049) Physical Properties P43290.10.14 10/17/2014
ERD(TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015
ERD(TST 6049) Physical Properties P40390A4.15 04/03/2015
ERD(T5T 6049) Physical Properties P44360.10.14-Ri 05/18/2015
ERD(i•ST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015
ERD(TST6049) Wind Uplift PLYG-5C89D5.05.16-1 05/17/2016
ERD(TST 6049) Physical Properties PLYG-SC8080.07.16- 07/16/2016
ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016
ERD(T5T 6049) Physical Properties PLYG-SC33040.12.16 22/27/2016
ERD(TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017
ERD(1•ST 6049) Physical Properties PLYG-SC12115.08.17 08/08/2027
iCC-ES,(EVL 2396) IBC Compliance ESR-1697 11/01/2014
Miami-Dade(CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015
Polyglass USA Manufacturing Affidavit Products Current 02/18/2009
Polygiass USA PA Affidavit Mule-Hide Cross Ltg 03/01/2008
Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011
UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.10/05/2018
4. PRODUcr DescRipmom
Y.4 '
• AliizcNabicaTty FasfetCe'd�Eln+detrtaym'erifis "
4.1.1 Elastobase.Is a fiberglass reinforced,SBS modified bitumen base sheet.
4.1.2 Efastobase P is a polyester-reinforced,SE.S modified bitumen base sheet.
4.1.3 Polyglass 62 Base is a fiberglass-reinforced,asphaltic base sheet.
4.1.4' Polygiass APP Base is a fiberglass-reinforced,APP modified bitumen base sheet.
.4:Z- :Sei;Adhlaiingt)iidayinerits:
4.2.1 Polystick MTS or Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane,glass
fiber reinforced,surfaced with polyolefinic film surface;meets FRSA/Ml April 2012.
4.2 2 Po dr-1R X a nomifi 60 mll thick rubberized.asphalt waterisroofing:membrane,glass fiber reinforced;-with an
- - _._ ..
t`agmate-Ourface,meets iAS7M D1970.
4.2.3 Polyst)ck TU Pius is a nominal 80-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with a
polyester fabric surface,meets ASTM D1970 and FRSA/TRI April 2012.
NEMO ETC,LLC. Evaluation Report P12060.02A9-R24
MM kate OAatharkatran#32455 6t"EDITION(2027)F9C NON-HVHZ EVALUATION FL5259-RU
Polygiaw Roof Underlayments;(954)233-2230 Revision 24:01/24/2018
Page3 of14
i
i
fONEMOJetc.
4.2.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced,with a granular surface;meets FRSA/TRI April 2022.
4.2.5- Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/mZ polyester
fabric surface;meets ASTM 01970 and FRSA/TRI April 2012.
4.2.6 Polyflex SAP, Polyflex SAP Fit, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA APP Cap Sheet(FR)are polyester .
reinforced,APP modified bitumen cap sheets;meet FRSA/TRI April 2012.
42.7 Polystick Dual Pro- is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced,with a polyester fabric surface;meets ASTM D1970.
4.2.8 . Polystick T'de Pro' is a nominal 60-mil thick dual-layer rubberized-asphalt waterproofing membrane, fiberglass
reinforced,with a polyester fabric surface;meets ASTM 01970 and FRSA/TRI April 2012.
4.2.9 Palystick MU-X is a nominal 54-mil thick..dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced,with a polypropylene film surface;meets AC188 and physical requirements of ASTM'D1970(See Section
Mach anoalty'Fastened and/oioirrifed Uderlyinents:l
4.3.2 Elastoflex G:TU is'a polyester reinforced, modified bitumen 'tile underiayment composed of a sand-surfaced SBS
modified bitumen backside and granule-surfaced APP modified bitumen top-side. Elastoflex 6 TU is for use as an
alternate to "Mineral Surface Roil Roofing"(ASTM D6380,Class M)in the "Single Ply System"-from FRSA/rRI April
2012 (04-12)beneath mechanically fastened the roof systems or Hot Asphalt applied "Cap Sheet" in the`?wo Ply
System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered the roof systems.
4.3.21. Elastoflex S6 6 and Elastoflex S6 6 FR are polyester reinforced,SBS modified bitumen cap sheets;meet ASTM D6164.
Elastoflex S6 6 and Elastoflex S6 G FR are for use as an alternate to"Mineral Surface Roll Roofing" (ASTM D6380,
Class M)in the"Single Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened the roof systems.
Elastoflex S6 G is for use as an alternate to Hot Asphalt applied"Cap Sheet"in the"Two Ply System"from FRSA/TRI
April 2012(04-12)beneath mechanically fastened or adhered tile roof systems. Elastoflex 56 G FR is for use as an
alternate to Hot Asphalt applied "Cap Sheet".in the "Two Ply System"from FRSA/TRI April 2012 (04-11) beneath
mechanically fastened the roof systems.
4:3.3. Polyflex G and Polyflex 6 FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
Polyflex 6 is for use as an alternate to Heat Applied"Cap Sheep'in the"rwo Ply System"from FRSA/rRI April 2012
(04-12)beneath mechanically fastened or adhered file roof systems. Polyflex G FR is for use as an alternate to Heat
Applied."Cap Sheet" in the'Two Ply System"from FRSA/TRI April 2022(04-12)beneath mechanically fastened tile
roof systems.
S. LiMRA ws:
5.11 This is a building code evaluation. Neither NEMOIetc. nor Robert Nieminen, P.E.are, in any way,the Designer of
Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ
5.3 Fire Classification is not part of this Evaluation Report-,refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 , Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering..
MEMO ETC,U.C. Evaluation Report P12060.02.09-R24
Certykate o1AuthOdzat1an#3z4Z 6'N EDITION(2o17)FBC NON-HVHZ EVALUATION FL5259-R28
Pctygrass Root Underrayments,(954)233-1230 Revision 24:01/24/2018
' Page 4 of 14
r
ONEMO etc.
5.5. Allowable Roof Covers:
•;: ;;,;;°�' ,�fu9tl�ti`;11�o�:Cov,d#'O�fici�s, ;:;: _ -s;::`: .. .
Underlayment AsphaltShingies Nall-On Tile Foam-on7ve Metal Wood Shakes slate
&Shingles
Elastobase Yes Yes Yes Yes Yes Yes
(Bae5heettn2-plysystem) (Base Sheetin2-plysysteml
Eiestobase P Yes Yes Yes Yes Yes Yes
l8�se5heetinzroWsymm) (Besasheetinz Arml
Polyglass G2 Base No Yes Yes eet No No No
W—Shin2-plrWMrn) f8waSheetin2-pl system)
PoWlass APP Base No Yes Yes No No No
(B—Sh-tin2-PIVz st.m) (Bme5heatln2•pWsVxwm)
PoWck M7'S or MTS PLUS Yes Yes No Yes Yes Yes
y11� l?9' s�elRs;' r � No No No Yes Yes
PolysdckTUP, No Yes Yes(See5S1) No No No
Polysdck TU Plus Yes Yes Yes(See S-11) Yes Yes Yes
PolvsddtTU Max No Yes Yes(See5.5.1) Yes No No
FolyweirDualPro Yes No No Yes Yes Yes
Polystid l lle Pro Yes- Yes Yes(See 53.1) Yes Yes Yes
Polyst)ckMU-X Yes No No Yes _ Yes Yes
Eiastofiel S6 G Yes Yes Yes(See 55.1) No Yes' Yes
Elastoflec 56 G FR Yes Yes No No Yes Yes
Elastoflex G TU Yes Yes Yes(See 55.1) No Yes Yes
PolyflexG Yes Yes Yes(See5S.1) No Yes Yes
PC(yfleu6 FR Yes Yes- No No Yes Yes
PolyfleicSAPorSAPFR Yes Yes Yes(See551) No Yes Yes
Mute Hide SA-APP Cap Sheet yes Yes Yes(See 55.1) No Yes Yes
or SA-APP Cap Sheet(FR)
5.5.1, 'Foam-On Tile"is limited to use of the following Approved.tile adhesives/underlayment combinations.
1I�Aikgi g4f71LAAQ PEERtA1(M C�OM�IN{lTIONS
Adhesive Florida Product
Approval Underiaymerrts
DAP Foam Touch'n Seal StormBond Roof FL1450& PolystickTU Plus,PolystickTU Max
Tile Adhesive
DowTilellondTM FL22525 PalystickTU P,PolystickTU Plus;Polyflex SAP or Tile Pro
Polystick TU P,PolystickTU Plus,Polystick TU Max,Polystick Tile Pro,
ICP Adhesives Polysetm AH-160 FL6332 Sastaflex G TU,Elastoflex S6 G,Polyflec G,PoWex SAP,PoWex SA Cap FR,
Mule-Hide SAAPP Cap Sheet or Mule-hide SA APP Cap Sheet(FR)
PolysticicTU F,PolystirkTU Plus,PolystickTU Max,Polystick Tile Pro,
ICP Adhesives Polysetm RTA 1 FL6276 Elastoflex G TU,Elastoflex S6 G,PobAex G,PoW
ex SAP,Polyflex SA Cap FR,
Mule-Hide SA-APP Cap Sheet or Mule-Hide SA APP Cap Sheet(FR)
=Refer to 771e Manufacturer's orAdhesive Manufacture's Florida Product Approval for Overturning Moment Resistance Performance
NEMO ETC,LLC. Evaluation Report P32060.02.09•R24
Cere cmgfAuthadmnon432a55 6 EDITION12017)FBCNON4PMZEVAWATION FL5259-R28
Polyalass Roof UnderkWnen s;(954)233-1230 Revistoti 24:01/24/2018
Page 5 of 14
I
I
II
I
WNEMOleft.
5.6 Allowable Substrates:
5.6.1 Direct-Bond to Deck:
Polystick(all variations),Dual P%Tile Pro,Polyflex SAP or SAP FR,Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR)self-adhered to:
➢ New untreated plywood;ASTM D41 primed new untreated plywood;Existing plywood;ASTM D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41.primed structural concrete; Huber Engineered Woods "ZIP System" Panels
(designed and installed to meet wind loads for project).
Note.-Polygtoss does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and debris prior to application of polystick membranes.
Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or Polyflex G FR torch-applied to:
➢ ASTM D41 primed structural concrete.
5.6.2 Bond-to-Insulation:
Polystick(all variations),Polyflex SAP or SAP FR,Mule-Hide-SA-APP Cap Sheet or SA-APP Cap Sheet(FR)self-adhered
to:
➢ ASTM C1299, Type 11, Gass i polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens.Deck
DuraGuard;Dens Deck Prime;or SECUROCK Gypsum-Fiber Roof Board.
Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
Polyflex G or Polyflex G FR torch-applied to:
➢ ASTM D41 primed structural concrete;Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, Insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on file
systems,insulation attachment shall be designed by.a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
5.63 Band to Mechanically Attached Base Laver.
Polystick(all variations),Polyflex SAP or SAP FR, Mule-Hide SA APP Cap Sheet or SA-APP Cap Sheet(FR)Dual Pro or
Tile Pro self-adhered to:
➢ ASTM D226,Type 1 or II felt,Elastobase;Elastobase P or Mule-Hide Nail Base.
Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to
➢ ASTM D226,Type I or II felt;Elastobase;Elastobase P,Mule-Hide Nail Base or Polyglass 62 Base.
Polyflex G or Polyflex G FR torch-applied to:
➢ Elastobase;Elastobase P,Mule-Hide Nail Base,Polyglass G2 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam-an the systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2612(04-12),Appendix A,Table 1,or as listed in Section 5.6.4 herein,or as tested in
accordance with FBC Section 1504.3.1.
NEMO ETC,LLC. Evaluation Report P12060.02.09-R24
WVJZMre of Autharbovan 832455 6TM EUrnoN m17)FBC NON-HVH2 EVALUATION FLS259-RZB
Polyglass Roof UnderlaymenW(4541233-1230 Revtslon 24:01/24/2018
Page 6 of 14
I -
ONEMOletc.
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all-underlayment systems beneath foam-on tile systems,where the underlayment
forms pan: of the load-path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012(04-12)and are used in foam-on the applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure
divided by 2(the 2 to 1 margin of safety per FBC 1504S has already,been applied).Refer to FRSA/TRi April 2012(04
12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads.
#1 Maximum Design Pressure=-90 osf..
Deck: Min.15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer. None
Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered.
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered
#2 Maximum Design Pressure=-97.5 nsf:
Dedc Min.15/324ndt plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered.
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x
1W ring shank nails through 32 ga.,1-5/8"diameter ttn-caps spaced 12-inch o.c.
#3 Maximum Design Pressure=-105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: we-3000
Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered.
Underlayment:Polystick TU P,Polystidc TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA APP Cap Sheet and
Mule-Hide•SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x
IA"ring shank nails through 32 ga.;.15/9"diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure=-135 psf:
Deck: Min.1S/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer (Optional)PG100orASTM D41
Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered.
Joints Min.4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
_ #5 Maximum Design Pressure=-315 asf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority•Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered.
Underlayment:Polystick TU P,Polystick TU Pius,Polystick TU Max,The Pro,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap
Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
#6 Maximum Design Pressure=-622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer. PG100 or ASTM D41
Underiaymerrt Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G.torch-applied.
.#7 Maximum Design Pressure=-30.0 osf :
Deck: Min.15/32--inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: &Inch o.c.at the 3-inch wide side laps and 64nch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered;
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA=APP Cap Sheet and
Mule-Hide SA APP Cap Sheet(FR),self-adhered.
NEMO ETC,LLC. Evaluation Report P12060.02.09-R24
CerV tcate o%Authodzatlon 93Z455 6'x EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-RZB
Polygiass Roof Underiayments;(954)Z33-1MIC Revision 24:M/24/2MO
I Page 7 of 14
I
ON'EMICIlleft.
#8 Maximum Design Pressure=-37.5 asf*:
Deck: Min.15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mute-hide Nail Base(pofyAlm top surface)
Fasteners: 11 ga.x 1.25-inch long x i-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows
Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered.
Underlayment:Polystick TU P,Polystick TU Plus,Polysdck TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered:
#9 Maximum Design Pressure=-37.5 asf":
Deck: Min.19/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)ortwo(2)layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inrh fang x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c at the 3-inch wide side laps and 12 inch o.c.at two(2)equally spaced staggered center rows.
Undedayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt
#10 Maximum Design Pressure=49 Dsf":
Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)layer ASTM D226,Type 11 felt
Fasteners: 11 ga.x 1.25-inch x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/&inch diameter tin caps
Spacing: 4-inch o.c at the 2-inch wide side laps and 4-inch c.c at two(2)equally spaced staggered center rows. .
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS or Polystick MTS PLUS,self-adhered.
Underlayment:Polystick TU P,Polystick TU Pius,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA,APP Cap Sheet(FR),self-adhered or Elastoflex G TU,applied In full mopping of hot asphalt.
#12 Maximum Design Pressure=43 Dsf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. .
Base Sheet: Two(2)layers ASTM D226,Type 11 felt
Fasteners: 11 ga.x 1.25-Inch long x 3/84nch head diameter annular ring shank roofing nails at 1-518-inch diameter tin caps
Spacing: 9-inch o.c at the 2-Inch wide side laps and 94nch o.c.-at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS or Polystick MTS PLUS,self-adhered.
Underlayment:Polystick TU P,Palystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP Fit,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU or Elastoflex S6.G,applied in full mapping of hot
asphalt.
#12 Maximum Design Pressure=-45 asf:
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastabase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9 rich o.c.at the 24nch wide side laps and Minch ox.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied In full mopping of hot asphalt or Polyflex G,torch-applied.
#13 Maximum Design Pressure=-52.5 asF.
Deckv Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Undedayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#14 Maximum Design Pressure=-S2.5 asf:
Deck: Min,15/32-inch plywood to meet project requirementsto satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastabase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch.o.c at the 3-inch wide side laps and 6-inch o.c at four(4)equally spaced staggered center rows.
Base Ply:. (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered.
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA APP Cap Sheet and
Mule-Hide SA APP Cap Sheet(FR),self-adhered.
NEMO ETC,LLC. Evaluation Report P12060.02.09-11124
Certbhate ofAuthadkoffon M455 6TM EDITION(?A17)PBC NON-HVHZ EVAWATION FL5259-R28
Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018
Page 8 of 14
I
I
I
i
i
ONEmolebt.
#15 Maximum Design Pressure=-525 psi:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastabase(sanded top surface for hot-asphalt or torch-applied cap or poly film surface for torch-appried cap)
Fasteners: Simplex Original Cap Nails
Spacing: . 6-inch o.c.at the 3-Inch wide side laps and 6-inch oc.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#16 Maximum Desian Pressure=-60 pd.
Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority HavingJurisdiction.
Base Sheet: Elastabase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface fortorch-applied cap)
Fasteners: 11 ga.x L254nch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch dlametertin caps
Spacing. 8-inch o.c.at the 4-inch wide side laps and 8-Inch o.c.at three(3)equally spaced staggered center rows.
Underlayment Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. .
#17 Maximum Design Pressure=-60 Psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap.or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing- 12-inch a.c.at the 4-Inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment,Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#18 Maximum Design Pressure=-67.S asf:
Deck: Min.1S/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment)
Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: &-inch o.c.at the 4-inch wide side laps and 8-inch o c.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-
applied.
#19 Maximum Design Pressure=-7S psfr.
Deck:* Min.15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: -Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underloyment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 34nch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 10-inch a.c.at the 4-inch wide side laps and 10-inch o c.at three(3)equally spaced staggered center rows.
Underlayment-Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or torch-applied or.Polyflex G,torch
-
applied.
#20 Maximum Design Pressure=-90 osf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:' Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: . Simplex MAi X Cap Fasteners
Spacing: 64nch a.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#21 Maximum Design Pressure=-90 DsiF
Deck: Min.15/32-inch plywood to meet project requirements to.satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastabase(sanded top surface for hot asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roafgrip'or OMG#14 Heavy Duty with OMG r Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 64nch o.c.at three(3)equally spaced staggered center rows
Underfaymeri.t•Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#22 Maximum Design Pressure=-90 Dsf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 44nch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Elastaflex G TU or Elastoflex S5 G,applied in full mopping of hot asphalt
NEMO em LM Evaluation Report P12060.02.09-R24
Cerra cM ofAuthonbatlon 032455 9m EDITION(2017)FBC NON-111VH2 EVALUATION FL5259•1128
Polyglass Roof Underlayments;1954)233-1?30 Revlsion 24:02/24/2018
Page 9 of 14
ALI
MEMO etc.
#23 Maximum Design Pressure
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roalgrip#14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 34nch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 9-Inch o.c.at the 4-inch wide side laps and 94nch o.c,at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastaflex S6 G, applied in full mapping of hot asphalt or torch applied or Polyflex G,torch
applied.
#24 Maximum Design Pressure=-97.5.Dsfi
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Havingiurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x L25-Inch x 3/8-inch head diameter annular ring shank roofing nails at 1=5/8-Inch diameter tin caps
Spacing: 4-inch o.c.at the 4-inch wide side laps and flinch o c,at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS or PoWck MTS PLUS,self-adhered.
Underlayment:Polystick-TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet.(FR),self-adhered.
#25 Maximum Design Pressure=-105 osf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface fortorch-applied cap)"
Fasteners: Simplex MAXX Cap Fasteners
spacing: 64nch o.c.at the 24nch wide side laps and IiAnch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastaflex S6 G,applied In full mopping of hot asphalt or Polyflex G,torch-applied.
#26 Maximum Design Pressure=-1125 Dsf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority HavingJurisdiction.
Base Sheet: Elastobase.or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/84nch diameter tin caps
Spacing: 6-Inch,o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin-caps
Base Ply: Palystick.MTS or Polystick MTS PLUS,self-adhered
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Po"ex SAP FR,Mule-Hide SA-APP Cap Sheet and
Male-Hide SA-APP Cap Sheet(FR),self-adhered.
#27 Maximum Design Pressure=-120
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-Inch o.c.at five(5)equally spaced staggered center rows.
Underayment.,Elastoflex G TU or Elastoflex S6.15,applied In full mopping of hot asphalt or Polyflex G,torch-applied.
#28 Maximum Design Pressure=-120 asf
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority-Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the flinch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt
S.6.4.1 All other direct-deck, adhered Polyglass underlayment systems beneath foam-on file systems carry a Maximum
Design Pressure of-45 psf.
NEMO M LLC Evaluation Report P120E0A2.09-1124
CwUJRcfe ofAuthOM0 tan 0324SS 6TM EDMON(2017)FBC NON-HVHXEVALUATION FL52'"9-R28
Polygiass Roof Underlaymerts;(954)233-1230 Revision 24,01/24/2018
Page 10 of 14
I
i
ONEMOletc.
5.6.4.2 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSA/TRI April 2012'(04-12),Appendix A,Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case,Zones 2 and 3 shad employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1,FM-Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked
with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016)for Zane 2/3 enhancements.
5.7 E=2 Wre Limitations:
Elastobase,Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after Installation.
Polystick IR:Xe or Polystick MU X shall not be left exposed for longer than 90-days after Installation.
Polystick MTS, MTS PLUS,TU P,TU Plus,TU Max,Dual Pro,Tile Pro or Elastoflex G TU shall not be left exposed for
longer than 180-days after installation.
Polyflex SAP or SAP FR, or Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive-set tile,in which case the maximum exposure is 30
dam,
Elastoflex S6 G or Elastoflex S5 6 FR or Polyflex G or Polyflex G FR does not have an exposure limitation,unless the
prepared roof covering is to be adhesive-set tile (Elastoflex S6 G•or Polyflex G only), in which case the maximum
exposure is 180 days.
5.8 PolyAlIck MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition,tested at standard laboratory conditions. Agreement between purchaser and seller,as
set forth In Section 4.3,Note 1 of AST•M D1970-15,should be established as to slip resistance.
5.9 Tile Slippage Limitations-MRSAYTRI April 2012(04-12)):
When loading roof tiles on the•uriderlayment in direct-deck file assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
• .,::i%. ::�I.IBL�;Z,.:�JtESF.IPBA�6'�;fIM1TA'1'IbH1SF,.OR;D('Er'r�'•,�jil.. -`:.:. _�, -EGIC 1.1L6JS�% 1701N5.
Underlayment Tile Profile Staging Method Maximum SlopeF ~
Elastoflex G TU Flat 10-tile stack' 7:12
Lugged 8-tile stack(6 over 2) 6.12
Elastoflex S6 G or 56 G FR Flat or Lugged 6-tile stack(4 over 2) 4:12
Polystick MTS or MTS PLUS Flat 6-tile stack(4 over 2) 5.12
Lugged 6-tile stack(4 over 2) 4:12
PolystickTile Pro Flat or Lugged 6-tile stack(4 over 2) 7:12
Flat 6-tile stack(4 over 2)or 10-tile stack 7:12
PolysticcTU Max Lugged 6-file stack(4 over 2) 7:22
Lugged 10•tile stack 6.22
Flat 6-tile stack(4 over 2) 6:22
PolystidcTU P Lugged 6-tile stack(4 over 2) 4:12
Polystick TU Plus Flat or lugged 6-tile stack(4 over 2) 7:12
Hat or Lugged 10-tlle stack 612
Polyflex G or G FR Flat or Lugged 6-tile stack(4 over 2) 4.12
Polyflex SA P or SA P FR Flat or Lugged 6-11le stack(4 over 2) 4:12
NEMO ETC,LLC. Evaluation Report P32060.02.09-R24
OUH&Ute of Authorm=n 032455 6�"EprnoN(2017)FBC NON-HVHZEVALUATION FL5259-R28
Poiygtm Roof Underlayments;(9541233-1230 Revision 24:01/24/2018
Page 11 of 14
I
ONEMOletc.
6. lawm'mmw:
6.1 PoliWass Roof Underlayments shall•be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
.6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate(if applicable).
6:3• dastohase.';flastioba'se�P:�•Male=Hide�Nair$asee. '�x��'"_"" '
6.3.1 Non-TileADalications:
Shall be installed in compliance.with the codified requirements for ASIM D226,Type 11 underlayment in FBC Table
1507.L1 fnr the type of prepared roof covering to be installed.
lilastobase,Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick,Polyflex SAP,Polyflex SA
P FR, Mule-Hide SA APP Cap Sheet or SAAPP Cap Sheet (FR),self-adhered, Elastoflex 6 TU, Elastoflex S6 6 or
Elastoflex S6 6 FR in hot asphalt or Polyflex 6 or Polyflex 6 FR,torch applied. Roof cover limitations are those are
those associated with the top-layer underlayment,as set forth in Table 1,'
-6.3.2 Tile Applications:
Elastobase,Elastobase P or Mule-Hide Nall Base are limited to use as a mechanically attached base sheet in the"Two
Ply System°from FRSA/TRI April 2012(04r12). Reference is made to Table A and Section 5.6A herein,coupled with
FRSA/TRl April 2012(04-12)Installation Manual.
6.4 . Pajjstw'wsv*jmP Ua�t.11i:�I 'TCI:.PfTtl.`P.IYSi•TU'M8$ DilodP11AYrJ=�O[POfyfieXSAP PC eX:�/�P'FR
Mule-Bide PPR' t .-• .110 c'
' A=A C:ip'Stte �Nlui ]hide 4AP1
6.4.1 Shall be Installed in compliance with the codified requirements for ASTM D1970(except Polystick TU P)underlayment
In FBC Table 1507.1.1 for the type of prepared roof covering to be installed.
6.4.2 Direct to-beckwith Mechanically Fastened Roof Covers:
All self-adhering materials,with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mute-Hide SA APP
Cap Sheet or SAAPP Cap Sheet OR)should be back-nailed in selvage edge seam in accordance with Polyglass/Mule-
Hide back nailing guidelines. Nails shalt be corrosion resistant, 11 gauge ring-shank type with a minimum 1-inch
diameter metal disk or Simplex-type metal cap nail,at a minimum rate of 12'o.c. Polystick TU Plus should be back-
nailed-using the above noted fasteners and spacing, in area marked 'nail area, area para clavar" on the face of
membrane. The head lap membrane is to cover the area being back-nailed.
All seal-lap seams (selvage laps) must be
firmly rolled with a minimum 28 lb. hand r
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro,align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric).
View of Ovelap Seam of Dual Pro and Tile pro
All over fabric and over-granule end-laps shall have a 6-Inch wide, uniform layer of Polyplus.50 Premium Modified
Wet/Dry Cement or Polyglass PGS00 Modified Cement applied in between the application of the lap.
Polystick TU Plus,Dual Pro and Tile Pro may not be used in any exposed application such as crickets,exposed valleys,
or exposed roof to wall details
j MEMO ETC,LLC. Evaluation Report M2060.02.09-R24
' CerWkoWOfAuthorlmtlonp32455 GPFU ION(20171FBCNON-NVhZEVALUATION FL5259-R28
Polyglass Roof Underlayments;(9541233-1230 Reuklon 24:01/24/2018
Page 12 of 14
WNEMOjeft.
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PG500 Modified Cement to the area in need of repair,followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be Installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 404b weighted-roller or,on steep slopes,use of a stiff broom with approximately 404bs of load applied
far the field membrane. Hand rollers are acceptable for rolling of patches,laps(min.28 lb roller)or small areas of the
roof that are not accessible to a large roller or broom.
6.4.3 Tile Applications lnat allawed for PoI rLstkk Dual Pro 1R Xe or Pb►vstick MU X)
Reference is made to FRSA%TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened file roofing over 2-ply system,consisting of Base Sheet and self-adhering top sheet(s),Base
Sheet fastening shall be not less than FRSA/TRI April 2012(04-12);Table L
For adhesive-set the applications,refer to Section 5.6A herein:
6.4.4 Two(2)Plv Underlavment Systems:
Polystick MTS or MTS PLUS followed by Polystick MTS,MTS PLUS,TU P,TU Plus,TU Max,Tile Pro,MU-X or Polyflex
SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with
the top-layer material. This Is not a requirement,but is allowable If a 2-ply underlayment system is desired.
Polystick MTS or MTS PLUS followed by Polystick TU P,TU Plus,TU Max,Tile Pro or Polyflex SAP is allowable for use
under foam-on file systems. Limits of use are those associated with the top-layer material. This is not a requirement,
but is allowable if a 2-ply underlayment system is desired.
' YL. a r;,F.:. na.•. _ -_ .r.Y.v.:fvp' - ;:F;I:.Rf•r ir:?.::::• ...,-_ °.•i:?-" -
��.. �A:�E�'•, .., 4..;,•,,;.,. ,r
6.5.1 Elastoflex 6 TU,Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published
Installation requirements. For use in file applications:
✓ Elastoflex 6 TU is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single
Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened the roof systems or the Hot Asphalt
applied"Cap Sheet"in the"Two Ply System"from FRSA/TRi April 2012(04-12)beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G is for use as an alternate to"Mineral Surface Roil Roofing"(ASTM D6380,Class M)in the"Single Ply
System"from FRSA/TRI April 2012 (04-12)beneath mechanically fastened the roof systems or the Hot Asphalt
I applied"Cap Sheet"in the'"rwo Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or
adhered file roof systems.
✓ Elastoflex S6 G.FR is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single
Ply System"from FRSA/TRI April 2012•(04-12)beneath mechanically fastened the roof systems or the Hot Asphalt
applied"Cap Sheet"in the"Two Ply System"from FRSA/iRl April 2012(04-12)beneath mechanically fastened file
roof systems.
6.5.2 ' For hot-asphalt-applications,Elastoflex G TU,Elastoflex S6 G or Elastoflex S5 G FR shall be fully asphalt-applied-to the
substrates noted in Section 5.6. Side laps shall be minimum 34nch and end-laps minimum 6-inch wide, off-set
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt
with asphalt extending approximately 3/8-inch beyond the lap edge.
3w a M: i'n t ,r..•. ti -�<: t::
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in the applications:
✓ Polyflex G is for use as an alternate to tie Heat Applied"Cap Sheet"in the`Two Ply System"from FRSAf MI April
2012(04-12)beneath mechanically fastened or adhered tile roof systems(Base Sheet Limited per 5.6.3).
✓ Polyflex G FR is for use as an alternate to the Heat Applied"Cap Sheet"in the'Two Ply System"from FRSA/TRI
April 2012(04-12)beneath mechanically fastened the roof systems(Base Sheet Limited per 5.6.3).
NEMO ETC,LLC. Evaluation Report P12060.02.09-R24
Certffmte ofAntlwrtmNana32t55 6T"EDITION(20i7)FU NON-HVH2 EVAWATION F1.5259-11128
Polygbw Roof Utaierlaymertts,(9%)233-1230 Revfslon 24:01/24/2018
Page 13 of 14
i
i
i
I
1
iALI)
WNEW10jetc.
6.6.2 PolyAex 6 or Poiyflex a FR shall be fully torch-applied to the substrates noted in Section 5.6. Side laps shall be
minimum 3-inch and end-laps minimum 6-Inch wide,offset minimum 3 feet from course to course. Side and end
laps shall be fully heat-welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap
edge.
67 TiileStaeilim,
6.7.1 Tile shall be loaded and staged Ina manner that prevents the slippage and/or damage to the undedayment. Refer to
Table 2 herein,and Poiygiass published requirements for Ile stag-mg.
6.7.2 Battens and/or Counter-battens,as required by the Ile manufacturer and FRSA/TW April 2012(0412)must be used
on all roof slopes greater than 7.12. Precautions should be taken as needed,such as the use of battens or nail-
boards,to prevent file sliding and/or damage to the uriderlayment during the loading process.
6.7.3 Polyglass specifies the minimum cure time after Installation of self-adhering membranes and before loading of
' roofing tiles is forty-eight(48)hours.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C.61620-3 CIA requirements. The following
plants have qualified products under their respective physical properties specifications.
Fernley,NV,Hazleton,PA&Winter Haven FL ASTM 019770 Polystick MU-X
Hazleton,PA M-D 13-0004 Elastoflex G TU
ASTM D1970 Polystick IR Xe
Hazleton,PA&Winter Haven,FL ASTM D1970&FRSA/TRI A ril 2012 Polystick TU Plus
ASTM D1970&FRSA/TRI April 2012 PoC ickTU Max
Tuscaloosa,AL ASTM D4601,Type II Pal Wass ass G2 Base
ASTM D226(physicals) Ebstobase,Elastobase P
ASTM D6509 Polyglass APP base
FRSA/TRI April 2012 Polystick MTS,Polystick MTS PLUS
FRSA/TRI April 2012 Pof stick TU P
Winter Haven,FL FRSA/TRI April 2012 Polyflex SAP,Polyflex SA P FR
ASTM D1970 Pot stick Dual Pro
ASTM D1970&FRSA/TRI April 2022 Polystick Tile Pro
ASTM D6164 Elastoflex S6,FJastollex S6 G FR
- ASTM D6222 PolyFlex G,Polyflex G FR
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.cha.neellor@us.ul.com
! -END OF EVALUATION REPORT-
MEMO ETC,LLC Evaluation Report P32060.02.09-R24
CatJ kWe 4Autha,baWn#32455, 6TM EDITION(ZM7)FBC AEON-WHZEVALUATION FL52S9-RZ8
Polyglass Roof Underlayments;(954)239-2230 Revision 24:01/24/2018