Loading...
HomeMy WebLinkAboutProduct Approval i• i 3 BCIS Home Log In User Registration I Hot Topics Submit Surcharge ( Stats&Facts Publications ; Contact Us SCIS Site Map, Links Search+ Id rr4 Product Approval USER:Public User „V P, Product Approval Menu>Product or Anplication Search>Application List RECEIVED a a� 231 Search Criteria JAN -2 Refine Search ST. Lucie County, Permitting Code Version 2017 FL# 20838.1 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results-Applications FL# Type Manufacturer Validated By. Status FL20838-R2 Affirmation Custom Window Systems Inc. Steven M. Urich,PE Approved History. FL#: FL20838.1 (717)317-8454 Model:SGD 8800 Description:Sliding Glass Door 8800 Series-4'X 8'Panels Category: Exterior Doors Subcategory:Sliding Exterior Door Assemblies -Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Crecilt Gare[ r .:Safe # . Business. & Professional' Regulation BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications I Contact Us I BCIS Site Map I Links I Search I Florida '1d Product Approval p USER:Public User &MI'Mom Product Approval Menu>Product or Application Search>Application List Search Criteria Refine Search Code Version 2017 FL# 20838.1 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results-Applications FL# Type Manufacturer Validated By Status FL20838-R2 Affirmation Custom Window Systems Inc. Steven M.Urich,PE Approved History FL#:FL20838.1 (717)317-8454 Model:SGD 8800 Description:Sliding Glass Door 8800 Series-4'X 8'Panels Category: Exterior Doors Subcategory:Sliding Exterior Door Assemblies *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Cop fight 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Credit Card Safe 20 � 3F . GENERASLIDING GLASS DOOR - LARGE MISSILE IMPACT 1.THEP PRODUCT 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND yylNppyy SYSTEMS MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING 1900 SW 44TH AVE. CODE(FBC),CURRENT EDITION AND IS RATED FOR USE IN THE OCALA,FLORIDA 34474 HIGH VELOCITY HURRICANE ZONE(HVHZ)AND IS RATED FOR yyWW.cWS.CC WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED IN ASTM E 1996 PER THE FBC. 165*'4 PANEL WIDTH8800 PVC 2.GLAZING OPTIONS:(SEE SHEET 3) 4616" 3.APPROVED CONFIGURATIONS INCLUDE BUT ARE NOT SLIDING GLASS MAX.PANEL WIDTH LIMITED TO: DOOR-IMPACT "PXXXXXXXXP A POCKET "XO" "OX" "xx" „OXO„ „XXX„ "OXXO" "XXXX" "PX" "PXX" "PXXX" "PXXXX" "PXXP" "PXXXXP" "PXXXXXXP", m " �3 Fw 2 TRACK,3 TRACK,4 TRACK 40 J'GLASS DLO II If _ 4.DESIGN PRESSURE RATING: NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE m AND GLASS TABLES ASTM E-1300-04. m 96" I� li -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE, 0 Z MAX, WATER INFILTRATION TEST PRESSURE AND GLASS TABLES z O UNIT B B ASTM E-1300-04. w CO HEIGHT W Z > B 5.ANCHORAGE:THE 33 113%STRESS INCREASE HAS NOT BEEN Q O LU 938" �� 11 USED IN THE DESIGN OF THIS PRODUCT.SEE SHEETS 10-11 y a MAX. X X �� X x F FOR ANCHOR DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 ❑ PANEL 12 WAS USED FOR WOOD ANCHOR CALCULATIONS. 0 HEIGHT ❑ w 6.PRODUCT APPROVED FOR IMPACT USE. SHUTTERS ARE NOT ¢ ❑ 8GLASS REQUIRED. p DLO z 7.ALL FRAMES ARE PROCESSED AND SCREWED ,,,»ilitillf" TOGETHER.VENTS ARE PROCESSED AND THERMAL WELDED ��,l PNORr=W 111, TOGETHER. 8.SERIES/MODEL DESIGNATION SGD-8800. Com; No 58201 :�-P 9.THE DESIGNATION X AND 0 STAND FOR THE FOLLOWING: A X=OPERABLE SASH,0=FIXED SASH,P=POCKET/HOOKSTRIP '.':P t STATE OF :4U E D A 12 12 11 10.SECTION CALLOUTS APPLY TO ALL CONFIGURATIONS IN A � 5�'0 R�-P C1�ai`, SIMILAR LOCATION. �I,.,#,/ONA�EN��� 11.WEEP SLOTS=1/2"x 1"LOCATED @ BOTH ENDS. y 11//21/2016 LUCKS A. LUCAS A.TURNER,P.E. FL PE#58201 Turner 1239 JABARA AVE. 2016-11-21 NORTH PORT,FL 34288 10:37+19:00 PH.941-360-1574 TABLE OF CONTENTS SHEET DESCRIPTION: GENERAL NOTES AND GENERAL NOTES&ELEVATIONS....1 DESIGN PRESSURE GLASS TYPE ELEVATIONS SECTION VIEWS.................................2 MAX. PANEL SIZE RATING SEE SHT 4 IMPACT RATING BOM&GLAZING DETAIL....................3 � DRAWN BY: DATE: EXTRUSIONS...................................4-5 +/-50 PSF A LARGE MISSILE BLZ 05/06/16 TRACK WIDTHS..................................6 48-15/16"x 93-3/8" +/-65 PSF B IMPACT DWG#.' REV.: ANCHOR SCHEDULE&NOTES........7 ANCHOR PATTERNS......................8-9 CWS-1150 1 INSTALLATION DETAILS.............10-11 •(4)PANELS SHOWN;HVHZ LIMITED TO MAX.(9)PANELS. OUTSIDE HVHZ,UNLIMITED NUMBER SCALE: SHEET OF PANELS IS ALLOWABLE AS LONG AS INDIVIDUAL PANELS DO NOT EXCEED PANEL SIZE AS SHOWN. 1:30 1 OF 11 41 28 11 40 � 35 14 WINDOW SYSTEMS� 34o� 1900 SW 44TH AVE. 34 Q OCALA,FLORIDA 34474 ❑ 12 60 36 Qq o o p a WWW.CWS.CC ❑ 14 10 I � ❑ ❑ I 29 56 23 Od7 d ❑ 8800 PVC 39 26 a q o p 34 14 SLIDING GLASS 39 DOOR-IMPACT 30 d d o a d 0 e� 19,20,21,58 uc m O P 34 ❑ ao W 36 14 Q ❑ ❑ I 15 ❑ d d ❑ �0 33 19,20,21,58 0� 12 m m 16 14 OL Z 36 SECTION VIEW B-B 6 z O 13 m D) W Z > 66 39 ❑❑� d F- Of 6 do❑O o O°0�0� L J❑ o 0 < o 12 - z 54,55 ��1I LJ❑ tttiW n4V O 13 'OtttPt40REb..�ii. 36 59 �tGa�;.��C E N 3F ❑ D ❑ D ❑ D ❑ o = No 56201 •�?� 16 [35 Q• STATE OF ;,Wt .,�SSf�NA;rcNttt• n T FIXED PANEL 33 ATTACHMENT 36 11/21/2016 32 17 LUCAS A.TURNER,P.E. FL PE#58201 8 1239 JABARA AVE. 23 NORTH PORT,FL 34288 63 O O PH.941-380-1574 ® ® 8 0 0 SHEET DESCRIPTION: El— 1100❑ ❑00 X100❑ n❑� �lm❑o01 SECTION VIEWS 67 39 27 ALTERNATE SILL RISER VIEW DRAWN BY: DATE: SECTION VIEW A-A LIMITED TO+65 BLZ 05/06/16 NO SILL RISER DWG 0.' REV.: NOTES: CWS-1150 1 ITEMS NOT SHOWN FOR CLARITY: 1)INSTALLATION W/NO SILL RISER ALLOWED TO THE FULL DP'S INDICATED ABOVE,IN LOCATIONS WHERE WATER INFILTRATION RESISTANCE 20,24-26,31,55-58,61-62,64-66 IS NOT REQUIRED,SUCH AS BUT NOT LIMITED TO LOCATIONS WHERE AN OVER HANG IS PRESENT THAT IS AS WIDE AS THE WALL IS TALL. SCALE: SHEET 1:3 2 OF 11 PARTS LIST PARTS LIST � ) ITEM PART# DESCRIPTION VENDOR MATERIAL ITEM PART# DESCRIPTION VENDOR MATERIAL �fll7CN //j)Tjf�•�/�(/Q 1 GLASS SEE THIS SHEET 51 S-2058 Screen,3-Track Sill Keymark Aluminum WINDOW SYSTEMS 2 146161 2-Track Sill Vision PVC 52 S-2059 Screen,Snap Cover Keymark Aluminum 1900 SW 44TH AVE. 3 H•6163 3-Track Sill Vision PVC 53 S-2070 Screen,Interlock Profile Aluminum OCALA,FLORIDA 34474 4 K6165 4-Track Sill Vision PVC 54 P-5477 Block,Anti-Lift Lawrence Nylon WVvW.CWS.CC 5 K6160 2-Track Head/Jamb Vision PVC 55 P-5559 Screw,#14 x 4"PH PN SMS Fastenal Steel 6 K6162 3-Track Head/Jamb Vision PVC 56 P-4269 Screw,#8 x 1"PH PN Tek Fastenal Steel ` 8800 PVC 7 H 6164 4 Track Head/Jamb Vision PVC 57 P-3556 Screw,#8 x 2.5"PH FL Tek Fastenal Steel 8 S-2064 Roller Track Insert Keymark Aluminum 58 P-4962 Screw,#8 x 3"PH FL Tek Fastenal Steel 25 SLIDING GLASS 9 S-6171 Cover,Sill Track Vision PVC 59 P-5565 Screw,#12 x 1 112"PH PN SMS Fastenal Steel FRAME CORNERS DOOR-IMPACT 10 S-6169 Coker,Interlock Vision PVC 60 P-5566 Screw,#12 x2 112"PH PN SMS Fastenal Steel MECHANICALLY FASTENED 11 S-6172 Cowr,Exernal ReinforcementIP-Hook Vision PVC 61 P-3609 Bumper,Panel Stop Parker Seals Rubber 1:B 12 S-6175 Track Filler,Frame Vision PVC 62 P-4291 Panel Stop Housing M&M Nylon00 13 K6166 Panel Stile/Rail Vision PVC 63 P-5479 Foam Block,Open Cell,0.844"x 0.531"x V Lamatek o 14 K6168 Interlock,Snap-On Vision PVC 64 P-5492 Gasket,Frame Assembly,2-Track Lamatek Butyl 15 K6167 Astragal Vision PVC 65 P-5493 Gasket,Frame Assembly,3-Track Lamatek Butyl m m 16 H-6170 Glazing Bead,I.G.,1" Vision PVC 66 P-5494 Gasket,Frame Assembly,4-Track Lamatek Butyl 17 142060 Sill Riser,2.875" Keymark Aluminum 67 P-4659 Dust Plug,1-1/4"x 3"x 0.5" Ultrafab 0 Z 18 K2062 Sill Riser,4.062" Keymark Aluminum 66 P-4366 Dust Plug,1"x 3"x 1" Ultrafab 19 P-5517 Panel Guide,Interlock Bear's Metal Aluminum 69 Screen,Spline Team Plastics Rubber W z 20 P-5558 Su ee Support Channel,Bot Rail,Interlock Bear's Metal Alum num 70 Scrn,Cloth O 21 P-5511 Cowr,Panel Guide,Interlock Lawrence Ion 71 Duraseal IGSpacer Quanex Alum/Butyl (L a 22 P-5516 Bracket,Fixed Panel Bear's Metal Aluminum PANEL HERMALRNE LD w Fe 23 P-3300 Wts .,0.280"x 0.187"Back,Fin,Black Ultrafab 1"OVERALL 1"OVERALL 1:8 ❑ 24 P-3438 Backbedding,Purfect Gaze"H'Hot Melt Henkel/Sika Silicone 16"TEMPERED 16"TEMPERED Q O 25 P-3514 Screw,#10 x 2"Ph Comb Hd Fastenal Steel 3" 3" 26 P-3587 Screw,#8 x 1"PH FL TEK-Roger Asm/Mortise Lock Fastenal Steel 8 AIRSPACE 2 AIRSPACE 0 _ 3"ANNEALED 3"HEAT STRENGTHENED 28 P-3789 HandeP-3752 Hole l Set with Thumb Turn Amesbury oDia. Progress lastics rr Roto Won 1 :&'LAMINATED :R'LAMINATED �%�%%`16 ,ro,?��•E N�t•;TGQ�i� 29 P-3792 Keeper Amesbury105"PVB INTERLAYER 105"PVB `JGP:•�\ s�•.•-P, 30 P-3793 Multi-Point Mortise Lock AmesburyINTERLAYER No 58201 '..-A 31 P-4250 Screw,#10 x 2.5"PH PN SMS-Keeper Fastenal Steel 1fi"ANNEALED 3„ =�t 32 P-5287 Tandem Roller Assy,2.125"Dia Wheel Amesbury 15 HEAT STRENGTHENED Ds rx_ '9: STATE OF ,4V 33 P-5438 Setting Blocks,0.090"x 0.875"x 1.5" Franke Lowe Rubber %0 . 34 141769 Reinforcement,Interlock Keymark Aluminum '.����• 0 R tpP;���`.� 35 K2068 Reinforcement,Astragal Keymark Aluminum 16 16 7 �1is`Sfp�jp;rON11p 36 S-1775 Reinforcement,Lock Stile/Rails Keymark Aluminum 33 8 7 GLASS BITE 33 8 GLASS BITE 37 K2111 Reinforcement,HD,Interlock Keymark Aluminum zz 38 S-2071 Reinforcement,E)dernal,Interlock Keymark Aluminum 11/21/2016 39 S-2069 Frame Insert,Installation Anchors Keymark Aluminum 24 PURFECT 24 PURFECT 71 GLAZER 71 GLAZE LUCAS A.TURNER,P.E. 40 K2063 P-Hoak Keymark Aluminum FL PE#58201 41 S-2065 P-Hook Ada or Keymark Aluminum 1239 JABARA AVE. 42 S-2048 Screen,Astragal Keymark Aluminum 13 13 NORTH PORT,FL 34288 43 S-2050 Screen,1-Track Head Keymark Aluminum PH.941-380-1574 44 K2051 Screen,1-Track Jamb Keymark Aluminum r7 n n rT SHEET DESCRIPTION: 45 S-2052 Screen,1-Track Sill Keymark Aluminum U U U \UI BOM AND GLAZING 46 S-2053 Screen,2-Track Head Keymark Aluminum DETAIL 47 S-2054 Screen,2-Track Jamb Keymark Aluminum GLASS TYPE A GLASS TYPE B DRAWN BY: DATE: 48 S-2055 Screen,2-Track Sill Keymark Aluminum DESIGN PRESSURE BLZ 05/06/2016 49 S-2056 Screen,3-Track Head Keymark Aluminum GLASS TYPE RATING DWG#: REV.: 50 S-2057 Screen,3-Track Jamb Keymark Aluminum A +/-50 PSF CWS-1150 1 B +/-65 PSF SCALE: SHEET 1.2 3 OF 11 g" Lj 1j„JJ146 8� 8„{.._. Y6L(lW/�2 ,a1517WINDOW SYSTEM16 � D 1900 SW 44TH AVE. s0❑❑❑0❑❑❑00� 32 OCALA,FLORIDA 34474 WWW.CWS.CC 2-Track Sill-6161 �„ 416 32 4„ 416L—T 1688�� PVCs?' SLIDING GLASS :::N (� O 16 DOOR-IMPACT it n r Sill Riser-2060 16 �O❑❑❑0❑❑❑0❑❑❑00� 2 I(J/ \tJl 6063-T6 �— Sill Riser-2062 °T w 3-Track Sill-6163 Panel Head/SiIVStile-6166 6063-T6 o Astragal-6167 P-Hook-2063 g 6063-T6 m m JL2c: 0 � O 4 38 �–.{-1" Z O „ = —J= „ I I 116 D❑❑❑0❑❑❑0❑❑❑0❑❑❑OHt--IL � 32 32 11" 4 2g �� W ZO tis 2" 0.100^ 39 a 4-Track Sill-6165 Reinf.,Ext-Interlock Reinf.,Frame-2069 m a F 4? Lj -2071 p EL ��� 2 „ 41 6005-T6 6063-T6 Q W 2-41-- Lock 4 14 P-Hook Adaptor-2065 5 Lock Stile-2086 6063-T6 �^1g" 1.5,- 13, a" z 113„ � I 34 tuuhr 0 3„ r1' 2 „ ,_ 16 20❑❑❑0❑❑❑OB -32 1 �g—",L g„ 36 98 1 No 58201 �-A 2-Track Head/Jamb-6160 �— 11 All 4' �' Cover,Ext Reinf.& Hookstrip-6172 8 „ 10 J— pro: '9; STATE OF .45 � T Cover,Interlock-6169 Reinf.,Interlock-1769A Reinf.,Lock Stile-1775 0 •..,o P:'Af 1 g 6005-T6 6005-T6 .�8`S,• O R l�.•'���:� 116 6., 0 „ 1 16" e" „ 8„ 37 �4S+ONA; 110❑❑❑0❑❑❑0❑❑❑OB 32 8 2 e 35 1 e'� /2016 3-Track Head/Jamb-6162 9 11!21URNE oiler Track Insert-2064 LUCAS A.TURNER,P.E. Cover,Sill Track-6171 6063-T5 FL PE#58201 10 s L 1239 JABARA AVE. 1021T6" NORTH PORT,FL 34288 1�" 7 �„ PH.941-360-1574 16 O O W-1 � 16 3 9 SHEET DESCRIPTION: 91 ❑❑❑0❑❑❑D❑❑❑o❑❑❑08 32" 1B" 11„ qg" Reinf.,HDInterlock-2111 EXTRUSIONS e 6005-T6 DRAWN BY: DATE: 4-Track Head/Jamb-6164 BLZ 05/06/16 12 IG Glazing Bead-6170 Reinf.,Astragal-2068 DWG N: REV.: Track Filler-6175 6005-T6 CWS-1150 1 scA�E: NOTE:ALL EXTRUSIONS ARE RIGID PVC UNLESS OTHERWISE NOTED. SHEET 1�2 4 OF 11 45 �I P6" I 43 12" 28"—'{I v WINDOW OWSSTEMS " 6„ 1 1„ I 1900 SW 44TH AVE. 6„ 16 1 OCALA,FLORIDA 34474 1g WWW.CWS.CC Screen,1-Track Sill-2052 Screen,1-Track Head-2050 O O O 16" 8800 PVC Ig16'— { I SLIDING GLASS I 46 22 1 DOOR-IMPACT 1s" 117 16' 1� Screen,2-Track Sill-2055 Bracket,Fixed Panel 3 Screen,2-Track Head-2053 P-5516 16 m Q o r 5 5�" m M 1651 _� 16 ti� 49 O O0 to �] 1 Z O if 16 T 1s i 16 w Screen,3-Track Sill-2056 1a.. U Z w Screen,3-Track Head-2056 54 '1 ,e I � LD � U) a —� W U f �r r`18 yl I+ Q o2u" 4T6 • z" �IT621„ S O 5" 1 52 Z 24 L Screen,Snap Cover-2059 16' 8" Block,Anti-Lift P �R�N..TG�'.i —r P-5477,Nylon ���Gq•:��CENSF.•Q2.�� Screen,1-Track Jamb-2051 3 een,Interlock-2097 I –Ji No 58201 Screen,Astragal-2048 fl? L "I 1s" :9• STATE OF ;•<u` a` _D FL �4��c�s q16 4716 I�16" a O� 2 116 1„ 1 �2�,� 19 Z— '�— ,s � � 11/21/2016 Screen,2-Track Jamb-2054 I 1 F-1„� 20 LUCAS A.TURNER,P.E. FL PE#58201 1 II1 1239 JABARA AVE. 11 I I I I II I III NORTH PORT,FL 34288 ,s I 1 11 11 11 4 X111 PH.941-380-1574 so 1 0 1 4„ 111111 2 5„ 111 ' 1 111 SHEET DESCRIPTION: 8 II I I 111111 III 1 111 EXTRUSIONS 11fi' 16, I I 111111 III X111 L I I I I I I 111 L,Fr71,' DRAWN 6Y: DATE: I IIII BLZ 05/06/2016 Screen,3-Track Jamb-2057 DWG#: REV.: CWS-1150 1 NOTE:ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. Panel Guide,Interlock-P-5517 Support Channel,Bot Cover,Interlock-Reinf. scALE: SHEET Rail-Interlock-P-5558 P-5511,Nylon 1:2 5 OF 11 1 B" 16" 6" V-�11UL4 SYSTEMS �f n —� 1900 SW 44TH AVE. ' OCALA,FLORIDA 34474 W W W.0 WS.CC 4.1 8800 PVC 9 H-2060 n 11 H- 62 SLIDING GLASS O °o❑ ❑o❑�❑ � XQ 0 O O 0 O DOOR-IMPAC T❑ o❑ °❑ ° ❑o❑0 ❑a❑ ❑ 00�am ❑ w 2T Sill w/Riser 3T Sill w/Riser 4T Sill w/Riser o 84 1 g" m ro O z z LL O z O 9 Q- F � � D ❑ O WEAL Of ow oD00 °❑ ❑o ❑ 0O ❑ ❑❑E1 [ o o ❑� lz 2T Sill w/1T Screen 3T Sill w/1T Screen ttttp�tnrryr 12q^ 13 " E N No 58201 STATE OF —N LJ °o❑❑❑°o❑❑0❑0❑❑0❑0� °0❑❑❑❑0❑❑❑❑0❑❑�❑0❑❑❑❑0� Z� 11/21/2016 3T Sill w/2T Screen 4T Sill w/1T Screen LUCAS A.TURNER,P.E. FL PE#58201 16N' 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: moO O TRACK WIDTHS Ojl DRAWN BY: DATE: BLZ 05/06 /16LjH1-JE;;j;L-J DWG#: REV.: o ❑ ❑❑❑❑oo❑❑ o❑ ❑ OoE] CWS-1150 1 SCALE: SHEET 4T Sill w/3T Screen 1:2 6 OF 11 ANCHORS @ 4- P-HOOK s" 4" P ANCHORS MAX 6"MAX.TYP. TYP:• 4" PANEL-TYP 3"EDGE p��,® • TYP. ! `• ISI Fes\ l�\ I i'\, /'•\ I /�\ /'•\ I /' OF PANEL WINDOW SYSTEMS I • IT\'p• 1 • I 1 I I 1 I TYP. 1900 SW 44TH AVE. OCALA,FLORIDA 34474 II I WWW.CWS.CC II 12"MAX.O.C. MAX I II - I 8800 PVC TYP I II I SLIDING GLASS LI II I I II I DOOR-IMPACT Lli I II I I II I U) I II I z I II I � wZ > II — MID-SPAN I a I II I II OF PANEL I O of U, 0 0 I => II => ¢ o I II I I II OZ u�uu I. ! I I. ! I, ! I, ! I. ! i I. ! I, ! I 1. ! �.•QS:.......... FIXED PANEL CLIPS :�:J ?trr4 v. No 59201 :9 NOTES: 'CIRCLED ANCHOR LOCATIONS REQ'D ONLY IN WOOD INSTALLATIONS. (SEE NEXT SHEET FOR DETAIL) 1.INSTALL TWO ANCHORS AT EACH INSTALLATION LOCATION SEE LAYOUT DETAILS ON SHEETS 8&9 EXCEPT FOR 2T SILL&WOOD INSTALLATION LOCATIONS.SEE SPECIAL LOCATIONS AND SPACING FOR 2T SILL . : ( ) Q: STATE OF :W` (SHEET 8).INSTALL ONE ANCHOR AT EACH WOOD INSTALLATION LOCATION(CIRCLED). SILL ANCHOR SPACING SAME AS HEAD FOR 3T AND 4T. INSTALL ONE ANCHOR AT EACH LOCATION IN HOOKSTRIP. C 0 R 10F'��c�+� 2 SHIMCONAS REQ AT TED OF HIGH INSTALDENSITLATION PLASTICNO BETTER.WOOD SHIMS ARE NOT .ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING SHIMS SHALL BE rr�i,S+O........ ..EN���� 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 10. zz 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST 11/21/2016 BE PROTECTED TO PREVENT REACTION. LUCAS A.TURNER,P.E. FL PE#58201 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM 1239 JABARA AVE. SPECIFIED IN TABLE 1,SHEET 10. NORTH PORT,FL 34288 PH.941-380-1574 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO, FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE. SHEET DESCRIPTION: INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. ANCHOR SCHEDULE AND NOTES 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3"FOR SOLID CONCRETE,6"FOR CMU MASONRY,1"FOR WOOD AND METAL. DRAWN BY: DATE: 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. BLZ 05/06/16 SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 10. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. DWG#: REV.: 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: CWS-1150 1 FMA/AAMA 100(FIN WINDOWS),FMA/AAMA 200(FLANGE WINDOWS), FMAANDMA 250(BOX WINDOWS),FMA/AAMA/WDMA 300(EXTERIOR DOORS) SCALE: SHEET 1.20 7 OF 11 E INTERLOCKS 086390900 4 ASTRAGAL PANEL P-HOOK 6"TYP, 21"O.C.MAX 6"TYP. WIDTH 3"TYP. 1-- 3"TYP. �^ TYP. I WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA,FLORIDA 34474 W W W.CWS.CC 0 ° —6--vp. 8800 PVC SLIDING GLASS w000suesTRATEs 2 �-{ DOOR-IMPACT 2T SILL ONLY 2T JAMB Ty p. INTERLOCKS o E ASTRAGAL PANEL P-HOOK 6"TYP 21"O.C.MAX 6"TYP. TYP. --1 WIDTH I--4"TYP.--� 4"TYP m m O Z Al Z O o � � LLI :z 0plrTypCO) 3"TYP. 0 6"TYP. 3 Q 0 x a4 a F TYP. U) D- ❑ Of 0 0 0 0 co, 12 o W Q ❑ Lu "TYP. WOOD SUBSTRATES TYP. ONLY 3T JAMB P. 0%,ADRE W�1,� 3T SILL �cetis � ��t No 58201 •�9 4 INTERLOCKS =�' � PANEL ASTRAGAL 6��T,p. WIDTH P-HOOK TYP. 21"O.C.MAX X9% STATE OF ?�W` �---4"TYP. 4"TYP. TYP. A,4 OR SiOfVAts ; 0 0 6 7YP' 11/21/2016 4 " TYP LUCAS A.TURNER,P.E. 4<"TYP. FL PE#58201 0 0 1239 JABARA AVE. 0 0 0 o NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: Ll ANCHOR PATTERNS WOOD SUBSTRATES 1 8" (JAMB&SILL) ONLY TYp, 4T JAMB 1 e DRAWN BY: DATE: 4T SILL Typ• BLZ 05/06/16 DWG#: REV.: CWS-1150 1 NOTE:¢=CENTERLINE OFINTERLOCK ORASTRAGAL SCALE: SHEET "CIRCLED ANCHOR LOCATIONS REQ'D ONLY IN WOOD INSTALLATIONS. 1:5 8 OF 11 4 INTERLOCKS 08699 m.l ASTRAGAL (i(y (((�/ 4 HOLE PATTERN P-HOOK WINDOW SYSTEMS 6"TYP.--{ PANEL FOR ANTI-LIFT 1900 SW 44TH AVE. BLOCKANCHORS 1-4"TYP--I OCALA,FLORIDA 34474 WIDTH W W W.CWS.CC 0 I If 0 0 0 0. 101 II I I I 8800 PVC SLIDING GLASS - - ' 1„TYP DOOR-IMPACT "TYP. WOOD SUBSTRATES �O I-II „n,p. 2T HEAD a"TYP ONLY ui INTERLOCKS ❑ f HOLE PATTERN ASTRAGAL 6”TYP. PANEL FOR ANTI-LIFT p-HOOK m m WIDTH BLOCKANCHORS F—4"TYP. 4"TYP. Q m Z O 0 0 0 -1 01 1 o I U Z W I m D- 4 3„ ° °' ° In 0 TYP. W U ❑ co ❑ W 0 0 0 01 0 ¢ ❑ 1 TYP Z ON Y WOOD SUBSTRATES ♦`♦%O", OREW 3T HEAD �CENS ♦` 5 .� F•.�Py'N t N. 58201 ti INTERLOCKS PANEL HOLE PATTERN ASTRAGAL WIDTH FORANn 6„TYP. -uFT P-HOOK 'QT'•.° P,.'��C BLOCKANCLF `4"TYP 4"TYP %�CC �.<,O R 1 Q.• \♦♦ S IOilo NA; 0 0 0111 7-- 11/21/2016 I o o 4 „ TYP. LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. 0 0 0 0 0 o NORTH PORT,FL 34288 PH.941-380-1574 0 SHEET DESCRIPTION: 1"TYp ANCHOR PATTERNS (HEAD) WOOD SUBSTRATES DRAWN BY: DATE: ONLY BLZ 05/06/16 4T HEAD DWG#: REV.: CWS-1150 1 NOTE:¢=CENTERLINE OFINTERLOCK ORASTRAGAL SCALE: SHEET CIRCLED ANCHOR LOCATIONS REQ'D ONLY IN WOOD INSTALLATIONS. 1:5 9 OF 11 2 TRACK HEAD ANCHORAGE (C86390mq"/-i� INTERIOR 1/4"MAX WINDOW SYSTEMS��LIIII//�� MIN.EDGE DIST. SEE LAYOUT ON BHT 9 1900 SW 44TH AVE. SEE TABLE 1 39,FRAME INSERT REQ'D AT OCALA,FLORIDA 34474 ALL FRAME ANCHOR LOCATIONS 39,FRAME INSERT REQ'D WWW.CWS.CC ;O[m AT ALL FRAME ANCHOR SUBSTTE LOCATIONS BY OTHRERS MIN.EMBEDMENT a 8800 PVC SEE TABLE 1 SEE TABLE 1 SLIDING GLASS BYRNSTALLER��NT cJAO OGO OC❑ 0 BON SH�BT DOOR-IMPACT INSIDE AND OUTg"MAX. SHIM O F MIN EDGE DIST p o� SEE TABLE 1 N PERIMETER SEALANT pJ0 m INTERIOR COMPLIANT WITH AAMA 800 BY INSTALLER INSIDE AND OUT O LL U) INSTALLATION ANCHOR ? 9 SEE TABLE 1 SUBSTRATE BY OTHERS MIN EMBEDMENT K SEE TABLE 1 SEE TABLE 1 Z O SEALANT BETWEEN SILL (L dEL RISER AND FRAME BY B HORIZONTAL SECTION 0 m INSTALLER 9 2 TRACK JAMB ANCHORAGE W U O O Ow PERIMETER SEALANT ��❑� 0❑�^�� 1<101 BY INSTALLER INSIDE AND OUT O'• DO NOT COVER Z SUEP HOLES BSTRATE MIN. ENT SEE TABLE ,�����Pg0REVVf BY OTHERS �C£ 3•,G��i�� SEE TABLE 11.13 JG,•' �' R•••y1p MIN.EDGE DIST. 39,FRAME INSERT REQ'D AT No 58207 SEE TABLE 1 ALL FRAME ANCHOR LOCATIONS Z15: STATE OF :4U / A VERTICAL SECTION 9 2 TRACK SILL ANCHORAGE PERIMETER SEALANT COMPLIANT WITH AAMA 800 x� BY INSTALLER INSIDE AND OUT INSTALLATION ANCHOR SEE TABLET 11/21/2016 MIN.EDGE DIST. LUCAS A.TURNER,P.E. EE TABLE 1 FL PE#58201 1239 JABARA AVE. SUBSTRATE BY OTHERS MIN.EMBEDMENT NORTH PORT,FL 34288 TABLE 1:APPROVED INSTALLATION FASTENERS SEE TABLE 1 SEE TABLE 1 PH.941-380-1574 SUBSTRATE TYPE ANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. SHEET DESCRIPTION: CONCRETE 2.0 KSI MIN. 1/4"ITW TAPCON 1-1/2" 4" INSTALLATION DETAILS CONCRETE(2.85 KSI MIN.) 1/4"ELCO ULTRACON 1-3/4" 2-1/7' HOOKSTRIP 2X MIN.SOUTHERN PINE(G=0.55) 1/4"IlW TAPCON OR 1-316' 7/8" 2 TRACK ELCO ULTRACON a'MAX.SHIM DRAWN BY: DATE: 2X MIN.SOUTHERN PINE(G=0.55) #12 WOOD SCREW 1-3/8" 7/B" BLZ 05/06/16 16 GAUGE(0.06(Y")MIN. #12-14 HILTI KWIK-FLEXOR ITW FULLTHREAD 12" STEEL STUD(33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060" DWG M REV.: 1/8"ALUM.(6063-T5 MIN.)OR #12 GRADE 5 SELF-TAPPING/ FULL THREAD C HORIZONTAL SECTION CWS-1150 1 1/9'STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125' 1/2 9 HOOK STRIP SCALE: HOOKSTRIP OR JAMB FRAME ONLY: 1/4"ELCO ULTRACON 1-314" 2-1/7' 1.3 SHEET HOLLOW OR GROUT-FILLED CMU ASTM C-90) 10 OF 11 3 TRACK HEAD ANCHORAGE 1/4"MAX SEE LAYOUT 39,FRAME INSERT REQ'D AT INTERIOR owgibm MIN.EDGE DIST. ON SHT 9 ALL FRAME ANCHOR LOCATIONS WINDOWSYSTEMS 1900 SW 444THHAAVVE. SEE TABLE 1,SHT 10 39,FRAME INSERT REQ'D . �� 0o AT ALL FRAME ANCHOR SUBSTRATE O LOCATIONS OCALA,FLORIDA 34474 BY OTHERS wvvW.CWS.CC SEE TABLE 1,SHT 10 MIN.EMBEDMENT SEE TABLE 1,SHT 10 PERIMETER SEALANT y� 0 ap❑ 8800 PVC BYINSTALLER °p❑ []°p�u0p ° INSIDE AND OUT p 1"MAX SLIDING GLASS SHIM oa SEE LAYOUT ON SHT 8 DOOR-IMPACT INSTALLATION ANCHOR INTERIOR oo �p SEE TABLE 1,SHT 10 H SEALANT BETWEEN SILL ZZ RISER AND FRAME BY ;: ❑ INSTALLER ❑ PERIMETER SEALANT p p p MIN EDGE DISTINS m m BY INSTALLER p p �L��-,Ipa e� SEE TABLE 1 SHT 10 DO NOT COVERDE AND T �o❑❑ °❑❑ ❑❑t�o� PERIMETER SEALANT LL Z WEEP HOLES COMPLIANT WITH AAMA 800 ? SUBSTRATE MIN.EMBEDMENT BY INSTALLER INSIDE AND OUT D SEE TABLE 1,BHT 10 w > BY OTHERS SUBSTRATE U Z W SEE TABLE 1,SHT 10 BY OTHERS MIN EMBEDMENT a O of MIN.EDGE DIST. 39,FRAME INSERT SEE TABLE 1,SHT 10 SEE TABLE 1 SHT 10 to a SEE TABLE 1,SHT 10 SEE LAYOUT ON BHT 8 REQ'D AT ALL FRAME W ANCHOR LOCATIONS / r \HORIZONTAL SECTION ❑ (—D"\ u\\VERTICAL SECTION 10 3 TRACK JAMB ANCHORAGE 01w --{I ❑ 3TRACK SILL ANCHORAGE 1/4 MAX QINTERIOR I Z E INSERT REQ'D MIN.EDGE DIST. 4 TRACK HEAD SEE LAYOUT 39.FRAME REQ'D AT ALLSERTFRAME 39,O AT ALL FRAME ANCHOR ♦♦♦♦♦gyp IORr=vv SEE TABLE 1,SHT 10 ON SHT 9 ANCHOR LOCATIONS O LOCATIONS ♦ i MIN.EMBEDMENT SUBSTRATE SEE TABLE 1,SHT 10 -Zi No 58201 %-A SUBSTRATE BY OTHERS M ro: it SEE TABLE 1,SHT 10 u STATE OF , U PERIMETER SEALANT SEELAYOUT ��O,p•.A, BY INSTALLER �o❑�Qo ° ° ° �Lti ON SHT 8 i�FS' O R IV �? INSIDE AND OUT p �P�O�00 �0❑� � MAX ❑ �i��iS�ONA� ♦♦�♦ SHIM INSTALLATION ANCHOR INTERIOR 11/21/2016 SEE TABLE 1,SHT 10 SEALANT BETWEEN SILL LUCAS A.TURNER,P.E. RISER AND FRAME BY FL PE#58201 INSTALLER MIN EDGE DIST 1239 JABARA AVE. PERIMETER SEALANT p p p 8 0� SEE TABLE 1 SHT 10 NORTH PORT,FL 34288 BYINSTALLER p p o^I ❑ PH.941-380-1574 INSIDE AND OUT °°❑� °❑❑❑°o❑❑ o❑❑F]RU SHEET DESCRIPTION: DO NOT COVER o� WEEP HOLES MIN.EMBEDMENT INSTALLATION DETAILS SUBSTRATE SEE TABLE 1,SHT 10 PERIMETER SEALANT 3&4 TRACK COMPLIANT WITH AAMA 800 BY OTHERS BY INSTALLER INSIDE AND OUT DRAWN BY: DATE: SEE TABLE 1,SHT 10 SUBSTRATE MIN EMBEDMENT BLZ 05/06/16 MIN.EDGE DIST. SEE LAYOUT 39,FRAME INSERT BY OTHERS SEE TABLE 1,SHT 10 ON BHT 8 REQ'D AT ALL FRAME SEE TABLE 1,SHT 10 SEE TABLE 1 SHT 10 DWG#: REV.: ANCHOR LOCATIONS �1 HORIZONTAL SECTION CWS-1150 1 E VERTICAL SECTION 10 4 TRACK JAMB ANCHORAGE SCALE: SHEET 10 4 TRACK SILL ANCHORAGE 1:3 11 OF 11