HomeMy WebLinkAboutProduct Approval i• i
3
BCIS Home Log In User Registration I Hot Topics Submit Surcharge ( Stats&Facts Publications ; Contact Us SCIS Site Map, Links Search+
Id
rr4 Product Approval
USER:Public User
„V
P,
Product Approval Menu>Product or Anplication Search>Application List RECEIVED
a a�
231
Search Criteria JAN -2
Refine Search
ST. Lucie County, Permitting
Code Version 2017 FL# 20838.1
Application Type ALL Product Manufacturer ALL
Category ALL Subcategory ALL
Application Status ALL Compliance Method ALL
Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL
Product Model, Number or Name ALL Product Description ALL
Approved for use in HVHZ ALL Approved for use outside HVHZ ALL
Impact Resistant ALL Design Pressure ALL
Other ALL
Search Results-Applications
FL# Type Manufacturer Validated By. Status
FL20838-R2 Affirmation Custom Window Systems Inc. Steven M. Urich,PE Approved
History. FL#: FL20838.1 (717)317-8454
Model:SGD 8800
Description:Sliding Glass Door 8800 Series-4'X 8'Panels
Category: Exterior Doors
Subcategory:Sliding Exterior Door Assemblies
-Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
Crecilt Gare[
r .:Safe
# .
Business. & Professional' Regulation
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications I Contact Us I BCIS Site Map I Links I Search I
Florida
'1d Product Approval
p
USER:Public User
&MI'Mom
Product Approval Menu>Product or Application Search>Application List
Search Criteria Refine Search
Code Version 2017 FL# 20838.1
Application Type ALL Product Manufacturer ALL
Category ALL Subcategory ALL
Application Status ALL Compliance Method ALL
Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL
Product Model, Number or Name ALL Product Description ALL
Approved for use in HVHZ ALL Approved for use outside HVHZ ALL
Impact Resistant ALL Design Pressure ALL
Other ALL
Search Results-Applications
FL# Type Manufacturer Validated By Status
FL20838-R2 Affirmation Custom Window Systems Inc. Steven M.Urich,PE Approved
History FL#:FL20838.1 (717)317-8454
Model:SGD 8800
Description:Sliding Glass Door 8800 Series-4'X 8'Panels
Category: Exterior Doors
Subcategory:Sliding Exterior Door Assemblies
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Cop fight 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
Credit Card
Safe
20 � 3F .
GENERASLIDING GLASS DOOR - LARGE MISSILE IMPACT 1.THEP PRODUCT
1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND yylNppyy SYSTEMS
MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING 1900 SW 44TH AVE.
CODE(FBC),CURRENT EDITION AND IS RATED FOR USE IN THE OCALA,FLORIDA 34474
HIGH VELOCITY HURRICANE ZONE(HVHZ)AND IS RATED FOR yyWW.cWS.CC
WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED IN
ASTM E 1996 PER THE FBC.
165*'4 PANEL WIDTH8800 PVC
2.GLAZING OPTIONS:(SEE SHEET 3)
4616" 3.APPROVED CONFIGURATIONS INCLUDE BUT ARE NOT SLIDING GLASS
MAX.PANEL WIDTH LIMITED TO: DOOR-IMPACT
"PXXXXXXXXP
A POCKET "XO" "OX" "xx" „OXO„ „XXX„ "OXXO" "XXXX"
"PX" "PXX" "PXXX" "PXXXX" "PXXP" "PXXXXP" "PXXXXXXP", m
" �3 Fw
2 TRACK,3 TRACK,4 TRACK
40 J'GLASS DLO II If
_ 4.DESIGN PRESSURE RATING:
NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE m
AND GLASS TABLES ASTM E-1300-04. m
96"
I� li -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE, 0 Z
MAX, WATER INFILTRATION TEST PRESSURE AND GLASS TABLES z O
UNIT B B ASTM E-1300-04. w CO
HEIGHT W Z >
B 5.ANCHORAGE:THE 33 113%STRESS INCREASE HAS NOT BEEN Q O LU
938" �� 11 USED IN THE DESIGN OF THIS PRODUCT.SEE SHEETS 10-11 y a
MAX. X X �� X x F FOR ANCHOR DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 ❑
PANEL 12 WAS USED FOR WOOD ANCHOR CALCULATIONS. 0
HEIGHT
❑ w
6.PRODUCT APPROVED FOR IMPACT USE. SHUTTERS ARE NOT ¢ ❑
8GLASS
REQUIRED. p
DLO z
7.ALL FRAMES ARE PROCESSED AND SCREWED ,,,»ilitillf"
TOGETHER.VENTS ARE PROCESSED AND THERMAL WELDED ��,l PNORr=W 111,
TOGETHER.
8.SERIES/MODEL DESIGNATION SGD-8800. Com; No 58201 :�-P
9.THE DESIGNATION X AND 0 STAND FOR THE FOLLOWING:
A X=OPERABLE SASH,0=FIXED SASH,P=POCKET/HOOKSTRIP '.':P t STATE OF :4U
E D A
12 12 11 10.SECTION CALLOUTS APPLY TO ALL CONFIGURATIONS IN A � 5�'0 R�-P C1�ai`,
SIMILAR LOCATION. �I,.,#,/ONA�EN���
11.WEEP SLOTS=1/2"x 1"LOCATED @ BOTH ENDS. y
11//21/2016
LUCKS A. LUCAS A.TURNER,P.E.
FL PE#58201
Turner 1239 JABARA AVE.
2016-11-21 NORTH PORT,FL 34288
10:37+19:00 PH.941-360-1574
TABLE OF CONTENTS SHEET DESCRIPTION:
GENERAL NOTES AND
GENERAL NOTES&ELEVATIONS....1 DESIGN PRESSURE GLASS TYPE ELEVATIONS
SECTION VIEWS.................................2 MAX. PANEL SIZE RATING SEE SHT 4 IMPACT RATING
BOM&GLAZING DETAIL....................3 � DRAWN BY: DATE:
EXTRUSIONS...................................4-5 +/-50 PSF A LARGE MISSILE BLZ 05/06/16
TRACK WIDTHS..................................6 48-15/16"x 93-3/8" +/-65 PSF B IMPACT DWG#.' REV.:
ANCHOR SCHEDULE&NOTES........7
ANCHOR PATTERNS......................8-9 CWS-1150 1
INSTALLATION DETAILS.............10-11 •(4)PANELS SHOWN;HVHZ LIMITED TO MAX.(9)PANELS. OUTSIDE HVHZ,UNLIMITED NUMBER SCALE: SHEET
OF PANELS IS ALLOWABLE AS LONG AS INDIVIDUAL PANELS DO NOT EXCEED PANEL SIZE AS SHOWN. 1:30 1 OF 11
41 28 11 40
�
35 14 WINDOW SYSTEMS� 34o� 1900 SW 44TH AVE.
34
Q OCALA,FLORIDA 34474
❑ 12 60 36 Qq o o p a WWW.CWS.CC
❑ 14 10 I � ❑ ❑ I
29 56 23 Od7 d ❑ 8800 PVC
39 26 a q o p 34 14 SLIDING GLASS
39 DOOR-IMPACT
30 d d o a d 0
e� 19,20,21,58 uc m
O P 34 ❑ ao W
36 14 Q
❑ ❑ I 15
❑ d d ❑
�0 33 19,20,21,58 0�
12 m m
16 14 OL Z
36 SECTION VIEW B-B 6 z O
13 m D)
W Z >
66 39 ❑❑� d F- Of
6 do❑O o O°0�0� L J❑ o 0
< o
12
- z
54,55 ��1I
LJ❑ tttiW n4V
O 13 'OtttPt40REb..�ii.
36 59 �tGa�;.��C E N 3F
❑ D ❑ D ❑ D ❑ o =
No 56201 •�?�
16 [35 Q• STATE OF ;,Wt
.,�SSf�NA;rcNttt•
n T FIXED PANEL
33 ATTACHMENT
36
11/21/2016
32 17 LUCAS A.TURNER,P.E.
FL PE#58201
8 1239 JABARA AVE.
23 NORTH PORT,FL 34288
63 O O
PH.941-380-1574
® ® 8 0 0 SHEET DESCRIPTION:
El— 1100❑ ❑00 X100❑ n❑� �lm❑o01 SECTION VIEWS
67
39 27 ALTERNATE SILL RISER VIEW DRAWN BY: DATE:
SECTION VIEW A-A LIMITED TO+65 BLZ 05/06/16
NO SILL RISER DWG 0.' REV.:
NOTES: CWS-1150 1
ITEMS NOT SHOWN FOR CLARITY: 1)INSTALLATION W/NO SILL RISER ALLOWED TO THE FULL DP'S INDICATED ABOVE,IN LOCATIONS WHERE WATER INFILTRATION RESISTANCE
20,24-26,31,55-58,61-62,64-66 IS NOT REQUIRED,SUCH AS BUT NOT LIMITED TO LOCATIONS WHERE AN OVER HANG IS PRESENT THAT IS AS WIDE AS THE WALL IS TALL. SCALE: SHEET
1:3 2 OF 11
PARTS LIST PARTS LIST � )
ITEM PART# DESCRIPTION VENDOR MATERIAL ITEM PART# DESCRIPTION VENDOR MATERIAL �fll7CN //j)Tjf�•�/�(/Q
1 GLASS SEE THIS SHEET 51 S-2058 Screen,3-Track Sill Keymark Aluminum WINDOW SYSTEMS
2 146161 2-Track Sill Vision PVC 52 S-2059 Screen,Snap Cover Keymark Aluminum 1900 SW 44TH AVE.
3 H•6163 3-Track Sill Vision PVC 53 S-2070 Screen,Interlock Profile Aluminum OCALA,FLORIDA 34474
4 K6165 4-Track Sill Vision PVC 54 P-5477 Block,Anti-Lift Lawrence Nylon WVvW.CWS.CC
5 K6160 2-Track Head/Jamb Vision PVC 55 P-5559 Screw,#14 x 4"PH PN SMS Fastenal Steel
6 K6162 3-Track Head/Jamb Vision PVC 56 P-4269 Screw,#8 x 1"PH PN Tek Fastenal Steel ` 8800 PVC
7 H 6164 4 Track Head/Jamb Vision PVC 57 P-3556 Screw,#8 x 2.5"PH FL Tek Fastenal Steel
8 S-2064 Roller Track Insert Keymark Aluminum 58 P-4962 Screw,#8 x 3"PH FL Tek Fastenal Steel 25 SLIDING GLASS
9 S-6171 Cover,Sill Track Vision PVC 59 P-5565 Screw,#12 x 1 112"PH PN SMS Fastenal Steel FRAME CORNERS DOOR-IMPACT
10 S-6169 Coker,Interlock Vision PVC 60 P-5566 Screw,#12 x2 112"PH PN SMS Fastenal Steel MECHANICALLY FASTENED
11 S-6172 Cowr,Exernal ReinforcementIP-Hook Vision PVC 61 P-3609 Bumper,Panel Stop Parker Seals Rubber 1:B
12 S-6175 Track Filler,Frame Vision PVC 62 P-4291 Panel Stop Housing M&M Nylon00
13 K6166 Panel Stile/Rail Vision PVC 63 P-5479 Foam Block,Open Cell,0.844"x 0.531"x V Lamatek o
14 K6168 Interlock,Snap-On Vision PVC 64 P-5492 Gasket,Frame Assembly,2-Track Lamatek Butyl
15 K6167 Astragal Vision PVC 65 P-5493 Gasket,Frame Assembly,3-Track Lamatek Butyl m m
16 H-6170 Glazing Bead,I.G.,1" Vision PVC 66 P-5494 Gasket,Frame Assembly,4-Track Lamatek Butyl
17 142060 Sill Riser,2.875" Keymark Aluminum 67 P-4659 Dust Plug,1-1/4"x 3"x 0.5" Ultrafab 0 Z
18 K2062 Sill Riser,4.062" Keymark Aluminum 66 P-4366 Dust Plug,1"x 3"x 1" Ultrafab
19 P-5517 Panel Guide,Interlock Bear's Metal Aluminum 69 Screen,Spline Team Plastics Rubber W
z
20 P-5558 Su ee
Support Channel,Bot Rail,Interlock Bear's Metal Alum num 70 Scrn,Cloth
O
21 P-5511 Cowr,Panel Guide,Interlock Lawrence Ion 71 Duraseal IGSpacer Quanex Alum/Butyl (L a
22 P-5516 Bracket,Fixed Panel Bear's Metal Aluminum PANEL HERMALRNE LD w Fe
23 P-3300 Wts .,0.280"x 0.187"Back,Fin,Black Ultrafab 1"OVERALL 1"OVERALL 1:8 ❑
24 P-3438 Backbedding,Purfect Gaze"H'Hot Melt Henkel/Sika Silicone 16"TEMPERED 16"TEMPERED Q O
25 P-3514 Screw,#10 x 2"Ph Comb Hd Fastenal Steel 3" 3"
26 P-3587 Screw,#8 x 1"PH FL TEK-Roger Asm/Mortise Lock Fastenal Steel
8 AIRSPACE 2 AIRSPACE 0
_ 3"ANNEALED 3"HEAT STRENGTHENED
28 P-3789 HandeP-3752 Hole l Set with Thumb Turn Amesbury oDia. Progress lastics rr Roto Won 1 :&'LAMINATED :R'LAMINATED �%�%%`16
,ro,?��•E N�t•;TGQ�i�
29 P-3792 Keeper Amesbury105"PVB INTERLAYER 105"PVB `JGP:•�\ s�•.•-P,
30 P-3793 Multi-Point Mortise Lock AmesburyINTERLAYER No 58201 '..-A
31 P-4250 Screw,#10 x 2.5"PH PN SMS-Keeper Fastenal Steel 1fi"ANNEALED 3„ =�t
32 P-5287 Tandem Roller Assy,2.125"Dia Wheel Amesbury 15 HEAT STRENGTHENED Ds rx_
'9: STATE OF ,4V
33 P-5438 Setting Blocks,0.090"x 0.875"x 1.5" Franke Lowe Rubber %0 .
34 141769 Reinforcement,Interlock Keymark Aluminum '.����• 0 R tpP;���`.�
35 K2068 Reinforcement,Astragal Keymark Aluminum 16 16 7 �1is`Sfp�jp;rON11p
36 S-1775 Reinforcement,Lock Stile/Rails Keymark Aluminum 33 8 7 GLASS BITE 33 8 GLASS BITE
37 K2111 Reinforcement,HD,Interlock Keymark Aluminum zz
38 S-2071 Reinforcement,E)dernal,Interlock Keymark Aluminum 11/21/2016
39 S-2069 Frame Insert,Installation Anchors Keymark Aluminum 24 PURFECT 24 PURFECT
71 GLAZER 71 GLAZE LUCAS A.TURNER,P.E.
40 K2063 P-Hoak Keymark Aluminum FL PE#58201
41 S-2065 P-Hook Ada or Keymark Aluminum
1239 JABARA AVE.
42 S-2048 Screen,Astragal Keymark Aluminum 13 13 NORTH PORT,FL 34288
43 S-2050 Screen,1-Track Head Keymark Aluminum PH.941-380-1574
44 K2051 Screen,1-Track Jamb Keymark Aluminum r7 n n rT SHEET DESCRIPTION:
45 S-2052 Screen,1-Track Sill Keymark Aluminum U U U \UI BOM AND GLAZING
46 S-2053 Screen,2-Track Head Keymark Aluminum DETAIL
47 S-2054 Screen,2-Track Jamb Keymark Aluminum GLASS TYPE A GLASS TYPE B DRAWN BY: DATE:
48 S-2055 Screen,2-Track Sill Keymark Aluminum DESIGN PRESSURE BLZ 05/06/2016
49 S-2056 Screen,3-Track Head Keymark Aluminum GLASS TYPE RATING DWG#: REV.:
50 S-2057 Screen,3-Track Jamb Keymark Aluminum
A +/-50 PSF CWS-1150 1
B +/-65 PSF SCALE: SHEET
1.2 3 OF 11
g" Lj
1j„JJ146
8� 8„{.._. Y6L(lW/�2 ,a1517WINDOW SYSTEM16 � D 1900 SW 44TH AVE.
s0❑❑❑0❑❑❑00� 32 OCALA,FLORIDA 34474
WWW.CWS.CC
2-Track Sill-6161
�„ 416 32 4„ 416L—T
1688�� PVCs?' SLIDING GLASS
:::N
(� O 16 DOOR-IMPACT
it
n r
Sill Riser-2060
16 �O❑❑❑0❑❑❑0❑❑❑00� 2 I(J/ \tJl 6063-T6
�— Sill Riser-2062 °T w
3-Track Sill-6163 Panel Head/SiIVStile-6166 6063-T6 o
Astragal-6167 P-Hook-2063
g 6063-T6 m m
JL2c:
0 � O 4 38 �–.{-1" Z O
„ = —J= „ I I
116
D❑❑❑0❑❑❑0❑❑❑0❑❑❑OHt--IL � 32 32 11" 4 2g �� W ZO
tis 2" 0.100^ 39 a
4-Track Sill-6165 Reinf.,Ext-Interlock Reinf.,Frame-2069 m a F 4?
Lj -2071
p EL
��� 2 „ 41 6005-T6 6063-T6 Q W
2-41--
Lock
4 14 P-Hook Adaptor-2065
5 Lock Stile-2086 6063-T6 �^1g" 1.5,-
13,
a" z
113„ � I 34 tuuhr
0 3„ r1' 2 „ ,_
16 20❑❑❑0❑❑❑OB -32
1 �g—",L g„ 36
98
1 No 58201 �-A
2-Track Head/Jamb-6160 �— 11 All 4' �'
Cover,Ext Reinf.&
Hookstrip-6172
8 „ 10 J— pro:
'9; STATE OF .45
�
T Cover,Interlock-6169 Reinf.,Interlock-1769A Reinf.,Lock Stile-1775 0 •..,o P:'Af
1 g 6005-T6 6005-T6 .�8`S,• O R l�.•'���:�
116 6., 0 „ 1 16" e" „ 8„ 37 �4S+ONA;
110❑❑❑0❑❑❑0❑❑❑OB 32 8 2 e 35 1 e'�
/2016
3-Track Head/Jamb-6162 9 11!21URNE
oiler Track Insert-2064 LUCAS A.TURNER,P.E.
Cover,Sill Track-6171 6063-T5
FL PE#58201
10 s L 1239 JABARA AVE.
1021T6" NORTH PORT,FL 34288
1�" 7 �„ PH.941-360-1574
16 O O
W-1
� 16 3 9 SHEET DESCRIPTION:
91
❑❑❑0❑❑❑D❑❑❑o❑❑❑08 32" 1B" 11„ qg" Reinf.,HDInterlock-2111 EXTRUSIONS
e 6005-T6 DRAWN BY: DATE:
4-Track Head/Jamb-6164 BLZ 05/06/16
12
IG Glazing Bead-6170 Reinf.,Astragal-2068 DWG N: REV.:
Track Filler-6175 6005-T6
CWS-1150 1
scA�E:
NOTE:ALL EXTRUSIONS ARE RIGID PVC UNLESS OTHERWISE NOTED. SHEET
1�2 4 OF 11
45 �I P6" I 43 12" 28"—'{I v WINDOW
OWSSTEMS "
6„ 1 1„ I 1900 SW 44TH AVE.
6„ 16 1 OCALA,FLORIDA 34474
1g WWW.CWS.CC
Screen,1-Track Sill-2052
Screen,1-Track Head-2050
O O O 16" 8800 PVC
Ig16'— { I SLIDING GLASS
I 46 22 1 DOOR-IMPACT
1s" 117
16' 1�
Screen,2-Track Sill-2055 Bracket,Fixed Panel 3
Screen,2-Track Head-2053 P-5516 16 m Q
o
r
5 5�" m M
1651 _� 16 ti� 49 O O0 to
�] 1 Z O
if
16
T 1s i 16 w
Screen,3-Track Sill-2056 1a.. U Z w
Screen,3-Track Head-2056 54 '1 ,e I � LD �
U) a
—� W U
f
�r r`18 yl I+
Q o2u" 4T6 • z" �IT621„ S O
5" 1
52 Z
24 L Screen,Snap Cover-2059 16' 8" Block,Anti-Lift P �R�N..TG�'.i
—r P-5477,Nylon ���Gq•:��CENSF.•Q2.��
Screen,1-Track Jamb-2051 3 een,Interlock-2097 I –Ji No 58201
Screen,Astragal-2048 fl?
L "I 1s" :9• STATE OF ;•<u`
a` _D FL �4��c�s
q16 4716
I�16" a O�
2
116 1„ 1 �2�,� 19 Z—
'�— ,s � � 11/21/2016
Screen,2-Track Jamb-2054 I 1 F-1„� 20 LUCAS A.TURNER,P.E.
FL PE#58201
1 II1 1239 JABARA AVE.
11 I I I I II I III NORTH PORT,FL 34288
,s I 1 11 11 11 4 X111 PH.941-380-1574
so 1 0 1 4„ 111111 2 5„ 111 ' 1 111 SHEET DESCRIPTION:
8 II
I I 111111 III 1 111 EXTRUSIONS
11fi' 16, I I 111111 III X111
L I I I I I I 111
L,Fr71,'
DRAWN 6Y: DATE:
I IIII BLZ 05/06/2016
Screen,3-Track Jamb-2057
DWG#: REV.:
CWS-1150 1
NOTE:ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. Panel Guide,Interlock-P-5517 Support Channel,Bot Cover,Interlock-Reinf. scALE: SHEET
Rail-Interlock-P-5558 P-5511,Nylon 1:2 5 OF 11
1 B"
16" 6" V-�11UL4 SYSTEMS
�f n
—� 1900 SW 44TH AVE.
' OCALA,FLORIDA 34474
W W W.0 WS.CC
4.1 8800 PVC
9 H-2060 n 11 H- 62 SLIDING GLASS
O
°o❑ ❑o❑�❑ � XQ 0 O O 0 O DOOR-IMPAC
T❑ o❑ °❑ ° ❑o❑0 ❑a❑ ❑ 00�am ❑ w
2T Sill w/Riser 3T Sill w/Riser 4T Sill w/Riser o
84 1 g" m ro
O z
z
LL O
z
O
9 Q- F �
� D ❑ O WEAL Of ow
oD00 °❑ ❑o ❑ 0O
❑ ❑❑E1 [ o o ❑�
lz
2T Sill w/1T Screen 3T Sill w/1T Screen
ttttp�tnrryr
12q^ 13
" E N
No 58201
STATE OF
—N LJ
°o❑❑❑°o❑❑0❑0❑❑0❑0� °0❑❑❑❑0❑❑❑❑0❑❑�❑0❑❑❑❑0� Z�
11/21/2016
3T Sill w/2T Screen 4T Sill w/1T Screen LUCAS A.TURNER,P.E.
FL PE#58201
16N' 1239 JABARA AVE.
NORTH PORT,FL 34288
PH.941-380-1574
SHEET DESCRIPTION:
moO O TRACK WIDTHS
Ojl DRAWN BY: DATE:
BLZ 05/06
/16LjH1-JE;;j;L-J
DWG#: REV.:
o ❑ ❑❑❑❑oo❑❑ o❑ ❑ OoE]
CWS-1150 1
SCALE: SHEET
4T Sill w/3T Screen
1:2 6 OF 11
ANCHORS @ 4- P-HOOK
s" 4" P ANCHORS
MAX 6"MAX.TYP. TYP:• 4" PANEL-TYP 3"EDGE
p��,® •
TYP. ! `• ISI Fes\ l�\ I i'\, /'•\ I /�\ /'•\ I /' OF PANEL WINDOW SYSTEMS
I • IT\'p• 1 • I 1 I I 1 I TYP.
1900 SW 44TH AVE.
OCALA,FLORIDA 34474
II I WWW.CWS.CC
II 12"MAX.O.C.
MAX I II - I 8800 PVC
TYP I II I SLIDING GLASS
LI II I
I II I DOOR-IMPACT
Lli
I II I
I II I
U)
I II I z
I II I �
wZ >
II — MID-SPAN I a
I II I
II OF
PANEL I O of
U, 0 0
I => II => ¢ o
I II I
I II OZ
u�uu
I. ! I I. ! I, ! I, ! I. ! i I. ! I, ! I 1. ! �.•QS:..........
FIXED PANEL CLIPS :�:J ?trr4
v. No 59201 :9
NOTES: 'CIRCLED ANCHOR LOCATIONS REQ'D ONLY IN WOOD INSTALLATIONS. (SEE NEXT SHEET FOR DETAIL)
1.INSTALL TWO ANCHORS AT EACH INSTALLATION LOCATION SEE LAYOUT DETAILS ON SHEETS 8&9 EXCEPT FOR 2T SILL&WOOD INSTALLATION LOCATIONS.SEE SPECIAL LOCATIONS AND SPACING FOR 2T SILL . :
( ) Q: STATE OF :W`
(SHEET 8).INSTALL ONE ANCHOR AT EACH WOOD INSTALLATION LOCATION(CIRCLED). SILL ANCHOR SPACING SAME AS HEAD FOR 3T AND 4T. INSTALL ONE ANCHOR AT EACH LOCATION IN HOOKSTRIP.
C 0 R 10F'��c�+�
2 SHIMCONAS REQ AT
TED OF HIGH INSTALDENSITLATION
PLASTICNO BETTER.WOOD SHIMS ARE NOT .ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING SHIMS SHALL BE rr�i,S+O........
..EN����
3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 10. zz
4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST 11/21/2016
BE PROTECTED TO PREVENT REACTION. LUCAS A.TURNER,P.E.
FL PE#58201
5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM 1239 JABARA AVE.
SPECIFIED IN TABLE 1,SHEET 10.
NORTH PORT,FL 34288
PH.941-380-1574
6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO, FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE. SHEET DESCRIPTION:
INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE.
INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. ANCHOR SCHEDULE AND
NOTES
7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3"FOR SOLID CONCRETE,6"FOR CMU MASONRY,1"FOR WOOD AND METAL. DRAWN BY: DATE:
8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. BLZ 05/06/16
SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 10. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. DWG#: REV.:
9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: CWS-1150 1
FMA/AAMA 100(FIN WINDOWS),FMA/AAMA 200(FLANGE WINDOWS), FMAANDMA 250(BOX WINDOWS),FMA/AAMA/WDMA 300(EXTERIOR DOORS) SCALE: SHEET
1.20 7 OF 11
E
INTERLOCKS 086390900
4 ASTRAGAL
PANEL P-HOOK 6"TYP, 21"O.C.MAX
6"TYP. WIDTH 3"TYP. 1-- 3"TYP. �^ TYP. I WINDOW SYSTEMS
1900 SW 44TH AVE.
OCALA,FLORIDA 34474
W W W.CWS.CC
0
°
—6--vp. 8800 PVC
SLIDING GLASS
w000suesTRATEs 2 �-{ DOOR-IMPACT
2T SILL ONLY 2T JAMB Ty
p.
INTERLOCKS o
E ASTRAGAL
PANEL P-HOOK 6"TYP 21"O.C.MAX
6"TYP. TYP.
--1 WIDTH I--4"TYP.--� 4"TYP m m
O
Z
Al Z O
o � �
LLI :z
0plrTypCO)
3"TYP. 0 6"TYP. 3 Q 0 x
a4 a F
TYP. U) D-
❑ Of
0 0 0 0
co, 12
o W
Q ❑
Lu
"TYP.
WOOD SUBSTRATES TYP.
ONLY 3T JAMB P. 0%,ADRE W�1,�
3T SILL �cetis
� ��t No 58201 •�9
4 INTERLOCKS =�'
�
PANEL ASTRAGAL 6��T,p. WIDTH P-HOOK TYP. 21"O.C.MAX X9% STATE OF ?�W`
�---4"TYP. 4"TYP. TYP. A,4 OR
SiOfVAts ;
0 0 6 7YP' 11/21/2016
4 "
TYP LUCAS A.TURNER,P.E.
4<"TYP. FL PE#58201
0 0 1239 JABARA AVE.
0 0 0 o NORTH PORT,FL 34288
PH.941-380-1574
SHEET DESCRIPTION:
Ll ANCHOR PATTERNS
WOOD SUBSTRATES 1 8" (JAMB&SILL)
ONLY TYp,
4T JAMB 1 e DRAWN BY: DATE:
4T SILL Typ• BLZ 05/06/16
DWG#: REV.:
CWS-1150 1
NOTE:¢=CENTERLINE OFINTERLOCK ORASTRAGAL SCALE: SHEET
"CIRCLED ANCHOR LOCATIONS REQ'D ONLY IN WOOD INSTALLATIONS. 1:5 8 OF 11
4
INTERLOCKS 08699 m.l
ASTRAGAL (i(y (((�/
4 HOLE PATTERN P-HOOK WINDOW SYSTEMS
6"TYP.--{ PANEL FOR ANTI-LIFT 1900 SW 44TH AVE.
BLOCKANCHORS 1-4"TYP--I OCALA,FLORIDA 34474
WIDTH
W W W.CWS.CC
0 I If 0 0 0 0. 101
II I I I 8800 PVC
SLIDING GLASS
- - ' 1„TYP DOOR-IMPACT
"TYP. WOOD SUBSTRATES �O
I-II „n,p. 2T HEAD a"TYP ONLY
ui
INTERLOCKS ❑
f HOLE PATTERN ASTRAGAL
6”TYP. PANEL FOR ANTI-LIFT p-HOOK m m
WIDTH BLOCKANCHORS
F—4"TYP. 4"TYP. Q m
Z O
0 0 0 -1 01 1 o I U Z W
I
m D-
4 3„
° °' ° In 0
TYP. W U
❑ co
❑ W
0 0 0 01 0 ¢ ❑
1 TYP Z
ON Y
WOOD SUBSTRATES ♦`♦%O", OREW
3T HEAD �CENS
♦` 5
.� F•.�Py'N
t
N. 58201
ti INTERLOCKS
PANEL HOLE PATTERN ASTRAGAL
WIDTH FORANn
6„TYP. -uFT P-HOOK 'QT'•.° P,.'��C
BLOCKANCLF `4"TYP 4"TYP %�CC �.<,O R 1 Q.• \♦♦
S
IOilo NA;
0 0 0111 7--
11/21/2016
I o o 4 „
TYP. LUCAS A.TURNER,P.E.
FL PE#58201
1239 JABARA AVE.
0 0 0 0 0 o NORTH PORT,FL 34288
PH.941-380-1574
0
SHEET DESCRIPTION:
1"TYp ANCHOR PATTERNS
(HEAD)
WOOD SUBSTRATES DRAWN BY: DATE:
ONLY
BLZ 05/06/16
4T HEAD DWG#: REV.:
CWS-1150 1
NOTE:¢=CENTERLINE OFINTERLOCK ORASTRAGAL SCALE: SHEET
CIRCLED ANCHOR LOCATIONS REQ'D ONLY IN WOOD INSTALLATIONS. 1:5 9 OF 11
2 TRACK HEAD ANCHORAGE (C86390mq"/-i�
INTERIOR 1/4"MAX WINDOW SYSTEMS��LIIII//��
MIN.EDGE DIST. SEE LAYOUT ON BHT 9 1900 SW 44TH AVE.
SEE TABLE 1 39,FRAME INSERT REQ'D AT OCALA,FLORIDA 34474
ALL FRAME ANCHOR LOCATIONS 39,FRAME INSERT REQ'D WWW.CWS.CC
;O[m
AT ALL FRAME ANCHOR
SUBSTTE LOCATIONS
BY OTHRERS MIN.EMBEDMENT a 8800 PVC
SEE TABLE 1 SEE TABLE 1
SLIDING GLASS
BYRNSTALLER��NT cJAO OGO OC❑ 0 BON SH�BT DOOR-IMPACT
INSIDE AND OUTg"MAX.
SHIM O
F
MIN EDGE DIST p
o� SEE TABLE 1 N
PERIMETER SEALANT pJ0 m
INTERIOR COMPLIANT WITH AAMA 800
BY INSTALLER INSIDE AND OUT O LL U)
INSTALLATION ANCHOR ? 9
SEE TABLE 1 SUBSTRATE BY OTHERS MIN EMBEDMENT K
SEE TABLE 1 SEE TABLE 1
Z
O
SEALANT BETWEEN SILL (L dEL
RISER AND FRAME BY B HORIZONTAL SECTION 0 m
INSTALLER 9 2 TRACK JAMB ANCHORAGE W U
O O Ow
PERIMETER SEALANT ��❑� 0❑�^�� 1<101
BY INSTALLER
INSIDE AND OUT O'•
DO NOT COVER Z
SUEP HOLES BSTRATE MIN. ENT
SEE TABLE ,�����Pg0REVVf
BY OTHERS �C£ 3•,G��i��
SEE TABLE 11.13
JG,•' �' R•••y1p
MIN.EDGE DIST. 39,FRAME INSERT REQ'D AT No 58207
SEE TABLE 1 ALL FRAME ANCHOR LOCATIONS
Z15: STATE OF :4U
/ A VERTICAL SECTION
9
2 TRACK SILL ANCHORAGE
PERIMETER SEALANT
COMPLIANT WITH AAMA 800 x�
BY INSTALLER INSIDE AND OUT INSTALLATION ANCHOR
SEE TABLET 11/21/2016
MIN.EDGE DIST. LUCAS A.TURNER,P.E.
EE TABLE 1 FL PE#58201
1239 JABARA AVE.
SUBSTRATE BY OTHERS MIN.EMBEDMENT NORTH PORT,FL 34288
TABLE 1:APPROVED INSTALLATION FASTENERS SEE TABLE 1 SEE TABLE 1 PH.941-380-1574
SUBSTRATE TYPE ANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. SHEET DESCRIPTION:
CONCRETE 2.0 KSI MIN. 1/4"ITW TAPCON 1-1/2" 4" INSTALLATION DETAILS
CONCRETE(2.85 KSI MIN.) 1/4"ELCO ULTRACON 1-3/4" 2-1/7' HOOKSTRIP
2X MIN.SOUTHERN PINE(G=0.55) 1/4"IlW TAPCON OR 1-316' 7/8" 2 TRACK
ELCO ULTRACON a'MAX.SHIM DRAWN BY: DATE:
2X MIN.SOUTHERN PINE(G=0.55) #12 WOOD SCREW 1-3/8" 7/B" BLZ 05/06/16
16 GAUGE(0.06(Y")MIN. #12-14 HILTI KWIK-FLEXOR ITW FULLTHREAD 12"
STEEL STUD(33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060" DWG M REV.:
1/8"ALUM.(6063-T5 MIN.)OR #12 GRADE 5 SELF-TAPPING/ FULL THREAD C HORIZONTAL SECTION CWS-1150 1
1/9'STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125' 1/2 9 HOOK STRIP SCALE:
HOOKSTRIP OR JAMB FRAME ONLY: 1/4"ELCO ULTRACON 1-314" 2-1/7' 1.3 SHEET
HOLLOW OR GROUT-FILLED CMU ASTM C-90) 10 OF 11
3 TRACK HEAD ANCHORAGE 1/4"MAX
SEE LAYOUT 39,FRAME INSERT REQ'D AT INTERIOR owgibm
MIN.EDGE DIST. ON SHT 9 ALL FRAME ANCHOR LOCATIONS
WINDOWSYSTEMS
1900 SW 444THHAAVVE.
SEE TABLE 1,SHT 10 39,FRAME INSERT REQ'D .
��
0o AT ALL FRAME ANCHOR
SUBSTRATE O LOCATIONS OCALA,FLORIDA 34474
BY OTHERS wvvW.CWS.CC
SEE TABLE 1,SHT 10 MIN.EMBEDMENT
SEE TABLE 1,SHT 10
PERIMETER SEALANT y� 0 ap❑ 8800 PVC
BYINSTALLER °p❑ []°p�u0p °
INSIDE AND OUT p 1"MAX SLIDING GLASS
SHIM oa SEE LAYOUT
ON SHT 8 DOOR-IMPACT
INSTALLATION ANCHOR INTERIOR oo �p
SEE TABLE 1,SHT 10 H
SEALANT BETWEEN SILL ZZ
RISER AND FRAME BY ;: ❑
INSTALLER ❑
PERIMETER SEALANT p p p MIN EDGE DISTINS
m m
BY INSTALLER p p �L��-,Ipa e� SEE TABLE 1 SHT 10
DO NOT COVERDE AND T �o❑❑ °❑❑ ❑❑t�o� PERIMETER SEALANT LL Z
WEEP HOLES COMPLIANT WITH AAMA 800 ?
SUBSTRATE MIN.EMBEDMENT BY INSTALLER INSIDE AND OUT D
SEE TABLE 1,BHT 10 w >
BY OTHERS SUBSTRATE U Z W
SEE TABLE 1,SHT 10 BY OTHERS MIN EMBEDMENT a O of
MIN.EDGE DIST. 39,FRAME INSERT SEE TABLE 1,SHT 10 SEE TABLE 1 SHT 10 to a
SEE TABLE 1,SHT 10 SEE LAYOUT ON BHT 8 REQ'D AT ALL FRAME W
ANCHOR LOCATIONS / r \HORIZONTAL SECTION ❑
(—D"\
u\\VERTICAL SECTION 10 3 TRACK JAMB ANCHORAGE 01w
--{I ❑
3TRACK SILL ANCHORAGE 1/4 MAX QINTERIOR I Z
E INSERT REQ'D
MIN.EDGE DIST. 4 TRACK HEAD SEE LAYOUT 39.FRAME REQ'D AT ALLSERTFRAME 39,O AT ALL FRAME ANCHOR ♦♦♦♦♦gyp IORr=vv
SEE TABLE 1,SHT 10 ON SHT 9 ANCHOR LOCATIONS O LOCATIONS
♦ i
MIN.EMBEDMENT
SUBSTRATE SEE TABLE 1,SHT 10 -Zi No 58201 %-A
SUBSTRATE
BY OTHERS M ro: it
SEE TABLE 1,SHT 10 u
STATE OF , U
PERIMETER SEALANT SEELAYOUT ��O,p•.A,
BY INSTALLER �o❑�Qo ° ° ° �Lti ON SHT 8 i�FS' O R IV
�?
INSIDE AND OUT p �P�O�00 �0❑� � MAX ❑ �i��iS�ONA� ♦♦�♦
SHIM
INSTALLATION ANCHOR INTERIOR 11/21/2016
SEE TABLE 1,SHT 10 SEALANT BETWEEN SILL LUCAS A.TURNER,P.E.
RISER AND FRAME BY FL PE#58201
INSTALLER MIN EDGE DIST 1239 JABARA AVE.
PERIMETER SEALANT p p p 8 0� SEE TABLE 1 SHT 10 NORTH PORT,FL 34288
BYINSTALLER p p o^I ❑ PH.941-380-1574
INSIDE AND OUT °°❑� °❑❑❑°o❑❑ o❑❑F]RU SHEET DESCRIPTION:
DO NOT COVER o�
WEEP HOLES MIN.EMBEDMENT INSTALLATION DETAILS
SUBSTRATE SEE TABLE 1,SHT 10 PERIMETER SEALANT 3&4 TRACK
COMPLIANT WITH AAMA 800
BY OTHERS BY INSTALLER INSIDE AND OUT DRAWN BY: DATE:
SEE TABLE 1,SHT 10
SUBSTRATE MIN EMBEDMENT BLZ 05/06/16
MIN.EDGE DIST. SEE LAYOUT 39,FRAME INSERT BY OTHERS
SEE TABLE 1,SHT 10 ON BHT 8 REQ'D AT ALL FRAME SEE TABLE 1,SHT 10 SEE TABLE 1 SHT 10 DWG#: REV.:
ANCHOR LOCATIONS �1 HORIZONTAL SECTION CWS-1150 1
E VERTICAL SECTION 10 4 TRACK JAMB ANCHORAGE SCALE: SHEET
10 4 TRACK SILL ANCHORAGE 1:3 11 OF 11