HomeMy WebLinkAboutProduct Approval (2) 4/25/2019 Florida Building Code Online
uaw.n
a a o # # q # #
13CIS Home Log In user Registration Hot Topic ! Submit Surcharge Stats&Facts Publications Contact Us I BC3s site'Map Links search I
d,
b
o pr
Product Approval
tR USER:Public user
Product Approval Menu>Product of AQ2 anon Search>ARPilcatlon List>Application Detail
FL f# FL1365-R7
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer ICP Adhesives&Sealants,Inc.
Address/Phone/Email 12505 NW 44th Street
Coral Springs,FL 33065
(888)774-1419 Ext 201
rylipetkonen@icpadhesives.com
Authorized Signature Rlku Yllpelkonen
ryilpeikonen@icpadhesives.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Cements-Adhesives-Coatings
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional
Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Evaluation Robert Nleminen
Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 02/07/2021
Validated By John W.Knezevlch,PE
� Validation Checklist-Hardcopy Received
Certificate of Independence FJ 1365 R7 COI 2017 01 COT Nleminen p_9
Referenced Standard and Year(of Standard) Standard Year
FM 4474 2011
UL 1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/12/2017
Date Validated 10/14/2017
Date Pending FBC Approval 10/17/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description
1365.1 ICP Adhesives CR-20 Spray applied,two-part reactive urethane foam adhesive
Limits of Use Installation Instructions
Approved for use in HVHZ:No 171-1365 R7 II 2017 10 FINAL Al ICP CR-20 FL1365-R7 pjf,
Approved for use outside HVHZ:Yes Verified By:Robert Nleminen PE-59166
https:tfwww.floridabuilding.org/pr/pr_app_fitl.aspx 1/2
4/25/201'9 Florida Building Code Online
Impact Resistant,N/A Created by Independent Third Party;Yes
Design Pressure:+N/A/-270 Evaluation Reports
Other:1.Refer to ER Section 5 for Limits of Use.2.The design pressure FL1365 R7 AE 2017 10 FINAL ER ICP CR-20 FL1365-117 p�f
herein pertains to one particular deck/Insulation Interface.Refer to ER Created by Independent Third Party:Yes
Appendix for all deck/insulation interfaces.3.Refer to Roof System Product
Approval for assembly design pressures.
rack Next
Contact Us::26�ir Stone Road.Tallahassee FL 32399 Phone 850-487-1824
The State of Florida is an AA/EEO employer.CQRYSigpt 2007-2013 State of Florida ::PjLy cy_Statement::Accessibility^statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to
this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(t),Florida
Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails provided may
be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the
Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,FS.,please click here,
Product Approval Accepts:
Credit Card
Safe
https:/Awww.floridabuilding.org/prlpr app_dti.aspx 212
. .
' .
�
|
EXTERIOR RESEARCH&DESIGN,L�C.
Certificate of Authorization#9503
3��CHR|8lANSTREE�UNIT 13
\ /���n ����
-�J � ���n�� � � !»~^p�~ OXFORD,CTUG478
|
(203)262-9245
EVALUATION REPORT
ICP Adhesives_and Sealants,-Inc. Evaluation Report
� 125O5NVV44mStreet FL1365-N7
Coral Springs,pL33O65 Date mfIssuance:Dg/20/2Q04
(888)774-1419 Revision G:1m/12/2017
mcopE:
This Evaluation Report is issued under Rule 61G20'3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the Wh Edition (2017) Florida Building Code
sections noted herein.
DsSCm|pnnm; ICP Adhesives CR-20
| LAocums: Labeling shall'be in accordance with the requirements the Accredited Quality Assurance Agency noted
|
herein.
COmnmusoCoxxpuAmcs; ThisEva|umdonReportisxoUdund|suuhtimeaothenome6product(s)changes,thureferenced
�
Quality Assurance documentodonchan0es'orpnzv\si6nsoftheCodethatve\atetothepnuduutohanQe. Acceptance of
� this Evaluation Report by the named client constitutes agreement to notify Robert Nham|nen, P.E. if the product
changes orthe referenced Quality Assurance documentation changes. Trinity IERDrequires acomplete review nfthis
Evaluation Report relative to updated Code requirements with each Code Cycle.
�
ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity / ERD Evaluated" maybe displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
fxsrc / om:Uponrequest,acopyofthixentireEva|uutinnReportuha||beprovidedtotheuxerbythemonufamLurero/
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages I through 3,plus a 5-page Appendix.
Prepared by:
1-111,001,
Robert iM.Nieminen,P.E. . The facsimile seal appearing was authorized by Robert
Florida Registration No.e165,Florida DCA AmE1983 r�—,'"`' ' wumm"��E.onz0/z2/z17.This does not serve aso"
electronically signed document
CERTIFICAT11014 or INDEPENDENCE:
z. Exterior Research&Design,LLC.d/WaTrinity | ERD does not have,nor does it Intend to acquire or will it acquire,a financial interest
inany company manufacturing ordistributing products itevaluates.
z. Exterior Research u Design, LLC. d/b/a Trinity | Exo is not owned, operated or controlled by any company manufacturing or
distributing products itevaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert m|eminen,p.E.does not have,nor will acquire,afinancial interest many other entity involved mthe approval process ofthe
product.
s. This i,o building code evaluation. Neither nrmuv|cno nor Robert wiemiuen, r.s.*are,many way,the Designer ufRecord for any
project on which this Evaluation Report,or previous versions thereof,Is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ER®
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Cements-Adhesives-Coatings
Compliance Statement: iCP Adhesives CR-20,as produced by ICP Adhesives and Sealants,Inc.,has demonstrated
compliance with the 6th Edition (2017) Florida Building Code through testing in accordance with the Standards set
forth herein. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth
herein.
2. STANDARDS:
Sections Prope Standard Year
1504.3.1 Wind FM 4474 2011
1504.3.1 Wind UL 1897 2012
3. REFERENCES:
Entity Examination Reference Date
FM(TST 1867) FM 4474/FM 4470 3012321 07/29/2002
FM(TST 1867) FM 4474/FM 4470 3019317 06/30/2004
FM(TST 1867) FM 4474/FM 4470 3032127 06/12/2009
UL,LLC:(TST 9628) UL 1897 02NK25677 04/01/2003
M-D BCCO(CER1592) HVHZ compliance 16-0315.02 04/07/2016
UL,U.C.(QUA 9625) Quality Assurance Service Confirmation,R20817 Exp.06/05/2018
4. PRODUCT DESCRIPTION:
4.1 ICP Adhesives CR-20 is a spray applied, two-part reactive urethane adhesives supplied in refillable and
disposable cylinders. The "Part A" and "Part B" Components are available in refillable cylinders or in pre-
pressurized disposable cylinders.
S. LIMITATIONS:
5.1 This is a building code evaluation. NeitherTrinitv4 ERD nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for
permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire classification is not covered in this Evaluation Report; refer to a current Roofing Materials Directory for
fire ratings of this product.
5.4 The roof cover adhered over the final layer of roof insulation shall be installed in accordance with the roof
cover manufacturer's Florida Product Approval and shall be compliant with FBC Chapter 15, including fire
classification,wind resistance,impact resistance and physical properties.
5.5 The roof cover adhered over the final layer of roof insulation shall be Approved for use with the specific
insulation components.
5.6 The overall wind performance of the completed roof assembly shall be the lesser of maximum design pressure
listed in Appendix 1 compared to that for the roof cover adhered to the referenced insulation,as documented
through an FBC Approved Test Laboratory,Evaluation Agency or Certification Agency.
5.6.1 Elevated pressure zones shall be addressed in accordance with ANSI/SPRI WD-1 or FM Loss Prevention Data
Sheet 1-29.
Exterior Research and Design,LLC Evaluation Report 02760.12.03-118
Certificate of Authorization#9503 6EDITION(2017)FBC NON-HVHZ EVALUATION FL1365-R7
ICP Adhesives CR-20;(888)774-1419 Revision 8:10/12/2017
Page 2 of 3
i
4TRINITYI,ERD
5.7 For existing substrates in recover or re-roof installation,the existing roof surface or existing roof deck shall
be examined by a representative of ICP Adhesives&Sealants,Inc.for compatibility and bond performance
with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project
design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented
with ANSI SPRI IA-1 ASTM E907
through field uplift testing in accordance w / , FM Loss Prevention Data Sheet
1-52 or Testing Application Standard TAS 124.
5.8 All products in the roof assembly shall have quality assurance audit in accordance with the FBC and F.A.C.
Rule 61020-3.
6. INSTALLATION:
6.1 ICP Adhesives CR-20 shall be installed in accordance with ICP Adhesives and Sealants, Inc. published
installation instructions,subject to the limitations outlined in Section 5.
6.2 The existing deck or roof surface shall be clean,smooth and free of foreign debris. Existing roof decks or roof
surfaces shall be examined by a representative of ICP Adhesives&Sealants,Inc.for suitability of use with ICP
Adhesives CR-20.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
7. MANUFACTURING LOCATIONS:
Tomball,TX
9. QUALITY ASSURANCE ENTITY:
UL,LLC.—QUA9625;(847)664-3623;LeAnna.Gradecki a uLcom
-THE FIVE(5)PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT-
Exterior Research and Design,I.I.C. Evaluation Report 02760.12.03-118
Certificate of Authorization#9503 6i"EDITION(2017)FBC NON-HVHZ EVALUATION FL1365-R7
ICP Adhesives CR-20;(888)774-1419 Revision 8:10/12/2017
Page 3 of 3
|
| �
QOTRINI—IYIERD
The following notes apply to the systems outlined herein:
1. The performance data contained herein pertains to substrate interfaces bonded With ICP Adhesives CR-20. If a roof system's Product Approval documentation does not
specifically include ICP Adhesives CR-20 with a particular substrate or Interface,the data noted herein can be used to compare with the maximum design pressure ofthe
roof assembly's interface with the top insulation layer. The lesser ufthe two applies.
2. Roofdecks shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Wind load resistance ufdmernufdeckshaUbedocumented
through proper codified and/or FBC Approval documentation. Lightweight Insulating Concrete(LWC)shall be cast in accordance with FBC Section 1917 to the satisfaction of
the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC Product Approval for specific deck construction and limitations. For
LWC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1. �
3. Unless otherwise noted,data pertains to ICP Adhesives CR-20 applied in continuous 2.5 to 3.5 inch ribbons spaced 12-inch o.c. �
4. Min.1-inch thick tapered polyisocya nu rate may be substituted for the referenced flat stock board for a Maximum Design Pressure(MDP)limitation of-117.5 psf.
I Bonded po)yisnqenumuteinsulation boards shall bemaximum 4x4ft.
b. For partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with
paC Chapter 18.and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used
methods are AN5VSPR|VVD1and Fk8Loss Prevention Data Sheet 1-29.
7. For existing substrates in recover or re-roof installation,the existing roof surface or existing roof deck shall be examined by a representative of ICP Adhesives&Sealants,Inc.
for compatibility and bond performance with the selected adhesive,and the existing roof system(for recover)shall be capable of resisting project design pressures on its
own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSVSPR| (A-1, ASTM [907, FM Loss
Prevention Data Sheet 1'5lorTesting Application Standard TAS 124,
' n. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure divided by 2
�
(the 2 to I margin of safety per FBC 1504.9 has already been applied).Refer to FBC 1609 for determination of design wind loads.
Ekterior Research and Design,I.I.C. niwnv|cnn Evaluation Report u7anzzos*nfor F4ass-1m
Certificate vfAuthorization#esos nmEDITION(2oz7FEIcwom-in*oEVALUATION Revision 8:10/12/2917
Prepared by: xohe�wiamim,�pe5yzaa ICP Adhesives 774-1419 xppenum�p��zov�
| '
| . .
'|
]
I
�TRINITY ERa
INS ULA ION NO COVER8OARD
TABLE 2;ICP ADHESIVES CR-20 PERFORMANCE DATA
RlG2D BOARD S T { _ , ,
Substrate(Notes 2&7) Insulation(Notes 3,4&5) MDP(psf)
APA Rated plywood or APA Rated Min.1.5-inch,min.1.25 pcf Insulfoam -52.5
OSB Deck Min.1.5-inch ACFoam II,ACFoam III,ISO 95+GL,H-Shield,H-Shield CG,ENRGY 3 or Multi-Max FA3 52.5
Galvanized Steel Min.1.5-inch ACFoam fl,ACFoam 111,ISO 95+GL,H-Shleld,H-Shield CG,ENRGY 3 or Multi-Max FA3 -52.5
Min.1.5-inch,min.1.25 pcf Insulfoam 87.5
Min.1.5-inch,min.1.5 pcf Insulfoam 180.0
Structural Concrete Deck Min.1.5-inch,min.2.0 pcf lnsulfoam -240.0
Min.1.5-inch Ultra-Max or Multi-Max FA-3,Min.1.3-inch ACFoam III or Min.SA-inch ACFoam 11,ISO 95+GL,H-Shleld,H-Shield CG,JM ISO 3 or ENRGY 3 -240.0
Min.0.25-inch Dens Deck,Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board -245.0
Min.1.5-inch ACFoam 11,ACFoam III,ISO 95+GL,H-Shield,H-Shield CG,ENRGY 3 or Multi-Max FA3 -270.0
Min.1.5-Inch,min.1.25 pcf Insulfoam -87.5
Structural concrete deck with Min.1.5-inch,min.1.5 pcf Insulfoam -180.0
Cellular Lightweight Concrete, Min 1.5-inch,min.2.0 pcf Insulfoam -215.0
minimum 300 psi -2150
Min.1.5-inch ACFoam!I,ACFoam III,ISO 95t GL,H-Shield,N-Shield CG,ENRGY 3 or Multi-Max FA3
Min.1.5-inch,min.1.25 pcf Insulfoam -52.5
Tectum Plank Min.0.25-inch Dens Deck,Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board -52.5
Min.1.5-inch ACFoam 11,ACFoam 111,ISO 9S+GL,H-Shield,H-Shield CG,ENRGY 3 or Multi-Max FA3 -52.5
Min.1.5-inch,min.1.25 pcf Insulfoam -87.5
Min.1.5-inch,min.1.5 pcf Insulfoam -180.0
Existing Gypsum Deck Min.1.5-inch,min.2.0 pcf Insulfoam -240.0
Min.0.25-inch Dens Deck,Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board -245.0
Min.1.5-inch ACFoam ll,ACFoam III,ISO 95+GL,H-Shield,H-Shield CG,ENRGY 3 or Multi-Max FA3 -257.5
Min.1.5-inch,min.1.25 pcf Insulfoam 87.5
Min.1.5-inch,min,1.5 pcf Insulfoam -180.0
Granule Surface Modified Bitumen Min.1.5-inch,min.2.0 pcf Insulfoam -240.0
Min.0.25-inch Dens Deck,Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board -245.0
Min.1.5-inch ACFoam Il,ACFoam Ill,ISO 95+GL,H-Shield,H-Shield CG,ENRGY 3 or Multi-Max FA3 -270.0
Min.1.5-inch,min.1.25 pcf Insulfoam -87.5
Min.1.5-inch,min.1.5 pcf Insulfoam -180.0
Sanded Surface Modified Bitumen Min.1.5-inch,min.2.0 pcf Insulfoam -222.5
Min.0.25-inch Dens Deck,Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board -222.5
Min.1.5-inch ACFoam ii,ACFoam SII,ISO 95+GL,H-Shield,H-Shield CG,ENRGY 3 or Multi-Max FA3 -222.5
Min.1.5-inch,min.1.25 pcf Insulfoam -87.5
Min.1.5-inch,min.1.5 pcf Insulfoam 180.0
Smooth Surface Built-Up Roof Min.1.5-inch,min.2.0 pcf Insulfoam -240.0
Min.0.25-inch Dens Deck,Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board -245.0
Min.1.5-inch ACFoam II,ACFoam III,ISO 95+GL,H-Shield,H-Shield CG,ENRGY 3 or Multi-Max FA3 -262.5
Exterior Research and Design,I.I.C.d/b/a Trinity ERD Evaluation Report 2760.12.03-118 for FL1365-R7
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 8:10/12/2017
Prepared by: Robert Nieminen,PE-59166 ICP Adhesives CR-20;(888)774-1419 Appendix 1,Page 2 of 5
i
�PTRINITYJERD
-TABLE 2:ICP ADHEsivEs CR-20 PERFORMANCE DATA-RtGID BOARD ItUSUTATl4N WITH C4VER64ARD - -
Substrate insulation(Notes 3,4&5) Coverboard(Notes 3,4&5) MDP(psf)
(Notes 2&7)
Min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or Min.0.5-inch Georgia Pacific
Min.1.5-inch,min.1.25 pcf Insulfoam FiberBase HD or FiberBase HD Excel,Structodek High Density Fiberboard Roof Insulation,Hubert A in.HD Coated -52.5
APA Rated plywood Fiberboard or DuraBoard,nominal 0.5-inch APA Rated plywood or APA Rated OSB
or APA Rated OSB Min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or Min.0.5-inch Georgia Pacific
Deck Min.1.5-inch ACFoam II,ACFoam III,ISO 95+GL,H-Shield,H- FiberBase HD or FiberBase HD Excel,Structodek High Density Fiberboard Roof insulation,Hubert!in.HD Coated -52.5
Shield CG,ENRGY 3 or Multi-Max FA3 Fiberboard or DuraBoard,nominal 0.5-inch APA Rated plywood or APA Rated OSB
Min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or Min.0.5-inch Georgia Pacific
Galvanized Steel Min.1.5-inch ACFoam II,ACFoam III,ISO 95+GL,H-Shield,H- FiberBase HD or FiberBase HD Excel,Structodek High Density fiberboard Roof Insulation,Hubert%in.HD Coated -52.5
Shield CG,ENRGY 3 or Multi-Max FA3 Fiberboard or DuraBoard,nominal 0.5-inch APA Rated plywood or APA Rated OSB
Min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or Min.0.5-inch Georgia Pacific
Min.1.5-inch,min.1.25 pcf Insulfoam FiberBase HD or FiberBase HD Excel,Structodek High Density Fiberboard Roof Insulation,Hubert X in.HD Coated -87.5
Fiberboard or DuraBoard,nominal 0.5-inch APA Rated plywood or APA Rated OSB
Min.0.75-inch,min.1.0-pcf,FM Approved expanded Min.0.5-inch Structodek High Density Fiberboard Roof Insulation,Georgia Pacific FiberBase HD or FiberBase HD
polystyrene insulation boards produced from BASF,AFM, 127.5
Excel or DuraBoard
NOVA or Flint Hill beads
Min.0.75-inch,min.1.0-pcf,FM Approved expanded
polystyrene insulation boards produced from BASF,AFM, Min.0.125-inch Sopraboard or Huebert h in.HD Coated Fiberboard -135.0
NOVA or Flint Hill beads
Min.1.5-inch Ultra-Max or Multi-Max FA-3,Min.1.3-inch
ACFoam III or Min.1.0-inch ACFoam 11,ISO 95+GL,H-Shield,H- Min.0:125-inch Sopraboard 157.5
Shield CG,1M ISO 3 or ENRGY 3
Min.1.5-inch Ultra-Max or Multi-Max FA 3,Min.1.3-inch Min.0.5-inch Structodek High Density Fiberboard Roof Insulation,Georgia Pacific FiberBase HD or FiberBase HD
ACFoam III or Min.1.04nch ACFoam ii,ISO 95+GL,H-Shield,H- -180'0
Excel,DuraBoard,Huebert
Structural Concrete Shield CG,JM ISO 3 or ENRGY 3 in.ND Coated Fiberboard
Deck Min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or Min.0.5-inch Georgia Pacific
Min.1.5-inch,min.1.5 pcf Insulfoam FiberBase HD or FiberBase HD Excel,Structodek High Density Fiberboard Roof Insulation or DuraBoard,nominal -180.0
0.5-inch APA Rated plywood or APA Rated OSB
Min.1.5-inch,min.2.0 pcf Insulfoam or ACFoam i1,ACFoam iIi, Min.0.5-inch Georgia Pacific FiberBase HD or FiberBase HD Excel or Structodek High Density Fiberboard Roof -202.5
150 95+GL,H-Shield,H-Shield CG,ENRGY 3 or Multi-Max FA3 Insulation
Min.1.5-inch,min.2.0 pcf Insulfoam Min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or nominal 0.5-inch APA Rated -240.0
plywood or APA Rated OSB
Min.1.5-inch Ultra-Max or Multi-Max FA-3,Min.1.3-inch Min.0.25-inch Dens Deck,SECUROCK Gypsum-Fiber Roof Board or Min.0.5-inch APA Rated plywood or RPA Rated
ACFoam III or Min.1.0-inch ACFoam II,ISO 95+GL,H-Shield,H- OSB -240.0
Shield CG,1M ISO 3 or ENRGY 3
Min.0.75-inch,min.1.0-pcf,FM Approved expanded Min.0.25-inch Dens Deck,SECUROCK Gypsum-Fiber Roof Board or Min.0.5-inch APA Rated plywood or APA Rated
polystyrene insulation boards produced from BASF,AFM, OSB -255.0
NOVA or Flint Hill beads
Min.1.5-inch ACFoam 11,ACFoam Rt,ISO 95+GL,H-Shield,H- Min.0.25-inch Dens Deck,Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board -270.0
Shield CG,ENRGY 3 or Multi-Max FA3
r
Exterior Research and Design,I.I.C.d/b/a Trinity ERD Evaluation Report 2760.12.03-R8 for FL1365-117
Certificate of Authorization#9503 6Tn EDITION(2017)FBC NON-HVHZ EVALUATION Revision 8:10/12f 2017
Prepared by: Robert Nieminen,PE-59166 ICP Adhesives CR-20;(888)774-1419 Appendix 1,Page 3 of 5
i
i
r
TRINITY ERD
TABLE 2(CONTINUED):ICP ADHESIVES CR-20 PERFORMANCE DATA RIGID BOARD(NSbLATION WtrH CQVERBOARD
i
Substrate insulation(Notes 3,4&5) Coverboard(Notes 3,4&5) MDP(psf)
i (Notes 2&7)
Min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or Min.0.5-inch Georgia Pacific ,
Min.1.5-inch,min.1.25 pcf Insulfoam FiberBase HD or FiberBase HD Excel,Structodek High Density Fiberboard Roof insulation,Hubert h in.HD Coated -87.5
Fiberboard or DuraBoard,nominal 0.5-inch APA Rated plywood or APA Rated OSB
Min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or Min.0.5-inch Georgia Pacific
Structural concrete Min,1.5-inch,min.1.5 pcf Insulfoam FiberBase HD or FiberBase HD Excel,Structodek High Density Fiberboard Roof Insulation or DuraBoard,nominal -180.0
deckwith Cellular 0.5-inch APA Rated plywood or APA Rated OSB
Lightweight Min.1.5-inch,min.2.0 pcf Insulfoam or ACFoam 11,ACFoam Ill, Min.0.5-inch Georgia Pacific FiberBase HD or FiberBase HD Excel or Structodek High Density Fiberboard Roof
Concrete,minimum 202.5
300 psi iSO 95+GL,H-Shleld,H-Shieid CG,ENAGY 3 or Muiti-Max FA3 insulation
Min.1.5-inch,min.2.0 pcf Insulfoam Min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or nominal 0.5-inch APA Rated -215.0
plywood or APA Rated OSB
Min.1.5-inch ACFoam II,ACFoam II I,ISO 95+GL,H-Shield,H-
Shield CG,ENRGY 3 or Multi-Max FA3 Min.0.25-inch Dens Deck,Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board 215.0
Min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or Min.0.5-inch Georgia Pacific
Min.1.5-inch,min.1.25 pcf Insulfoam FiberBase HD or FiberBase HD Excel,Structodek High Density Fiberboard Roof Insulation,Hubert Y in.HD Coated -52.5
Tectum Plank Fiberboard or DuraBoard,nominal 0.5-inch APA Rated plywood or APA Rated OSB
Min.1.5-inch ACFoam II,ACFoam III,I50 95+GL,H-Shield,H- Min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or Min.0.5-inch Georgia Pacific
Shield CG,ENRGY 3 or Mutt]-Max FA3 FiberBase HD or FiberBase HD Excel,Structodek High Density Fiberboard Roof Insulation,Hubert Y:in.HD Coated 52.5
Fiberboard or DuraBoard,nominal 0.5-inch APA Rated plywood or APA Rated OSB
Min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or Min.0.5-inch Georgia Pacific
Min.1.5-inch,min.1.25 pcf Insulfoam FiberBase HD or FiberBase HD Excel,Structodek High Density Fiberboard Roof insulation,Hubert'%in.HD Coated -87.5
Fiberboard or DuraBoard,nominal 0.5-inch APA Rated plywood or APA Rated OSB
Min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or Min.0.5-inch Georgia Pacific
Min.1.5-inch,min.1.5 pcf Insulfoam FiberBase HD or FiberBase HD Excel,Structodek High Density Fiberboard Roof insulation or DuraBoard,nominal -180.0
Existing Gypsum
0.5-inch APA Rated plywood or APA Rated OSB
Deck Min.1.5-inch,min.2.0 pcf Insulfoam or ACFoam 11,ACFoam III, Min.0.5-inch Georgia Pacific FiberBase HD or FiberBase HD Excel or Structodek High Density Fiberboard Roof
-202.5
iSO 95+GL,H-Shield,H-Shield CG,ENRGY 3 or Multi-Max FA3 insulation
Min.1.5-inch,min.2.0 pcf Insulfoam Min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or nominal 0.5-inch APA Rated -240.0
plywood or APA Rated OSB
Min.1.5-inch ACFoam II,ACFoam III,ISO 95+GL,H-Shield,H- Min 0.25-inch Dens Deck,Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board -257.5
Shield CG,ENRGY 3 or-Multi-Max FA3
Exterior Research and Design,I.I.C.d/b/a Trinity ERD Evaluation Report 2760.12.03-R8 for FL3365-R7
Certificate of Authorization#9503 6TH EDITION(2017)FBC NON-HVHZ EVALUATION Revision 8:10/12/2017
Prepared by: Robert Nieminen,PE-59166 ICP Adhesives CR-20;(888)774-1419 Appendix 1,Page 4 of 5
i
V
I
TRINITY I ERD
TABLE 2(CONTINUED):ICP ADHESIVES CR-20 PERFORMANCE DATA-RiGID BOARD INsutATiON WITH COVERBOARD-
Substrateinsulation(Notes 3,4&5) Coverboard(Notes 3,4&5)
MDP(psf)
(Notes 2&7)
Min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or Min.0.5-inch Georgia Pacific
Min.1.5-inch,min.1.25 pcf Insulfoam FiberBase HD or FiberBase HD Excel,Structodek High Density Fiberboard Roof insulation,Hubert%in.HD Coated -87.5
Fiberboard or DuraBoard,nominal 0.5-inch APA Rated plywood or APA Rated OSB
Min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or Min.0.5-inch Georgia Pacific
Min.1.5-inch,min.1.5 pcf Insulfoam FiberBase HD or FiberBase HD Excel,Structodek High Density fiberboard Roof Insulation or DuraBoard,nominal -180.0
Granule Surface 0.5-inch APA Rated plywood or APA Rated OSB
Modified Bitumen Min,1.5-inch,min.2.0 pcf Insulfoam or ACFoam II,ACFoam III, Min.0.5-inch Georgia Pacific FiberBase HD or FiberBase HD Excel or Structodek High Density Fiberboard Roof -202.5
ISO 95+GL,H-Shield,H-Shield CG,ENRGY 3 or Multi-Max FA3 insulation
Min.1.5-inch,min.2.0 pcf Insulfoam Min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or nominal 0S-inch APA Rated -240.0
plywood or APA Rated OSB
Min.1.5-inch ACFoam II,ACFoam III,ISO 95+GL,H-Shield,H- Min 0.25-inch Dens Deck,Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board -2700
Shield CG,ENRGY 3 or Multi-Max FA3
Min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or Min.0.5-inch Georgia Pacific
Min.1.5-inch,min.1.25 pcf Insulfoam FiberBase HD or FiberBase HD Excel,Structodek High Density Fiberboard Roof Insulation,Hubert Y in.HD Coated -87.5
Fiberboard or DuraBoard,nominal 0.5-inch APA Rated plywood or APA Rated OSB
Min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or Min.0.5-inch Georgia Pacific
Min.1.5-inch,min.1.5 pcf Insulfoam FiberBase HD or FiberBase HD Excel,Structodek High Density Fiberboard Roof Insulation or DuraBoard,nominal -180-0
Sanded Surface 0.5-inch APA Rated plywood or APA Rated OSB
Modified Bitumen Min.lS=inch,min.2.0 pcf Insulfoam or ACFoam ii,ACFoam ill, Min.0.5-inch Georgia Pacific FiberBase HD or FiberBase HD Excel or Structodek High Density Fiberboard Roof -202:5
ISO 95+GL,H-Shield,H-Shield CG,ENRGY 3 or Multi-Max FA3 insulation
Min.1.5-inch,min.2.0 pcf Insulfoam Min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or nominal 0.5-inch APA Rated -222.5
plywood or APA Rated OSB
Min.1.5-inch ACFoam 11,ACFoam ill,ISO 95+GL,H-Shield,H- Min.0.254rich Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board -222.5
Shield C6,ENRGY 3 or Multi-Max FAB
Min,0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or Min.O.S-inch Georgia Pacific
Min.1.5-inch,min.1.25 pcf Insulfoam FiberBase HD or FiberBase HD Excel,Structodek High Density Fiberboard Roof Insulation,Hubert Y:in.HD Coated -87.5
Fiberboard or DuraBoard,nominal 0.5-inch APA Rated plywood or APA Rated OSB
Min.0.25-inch pens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or Min.0.5-inch Georgia Pacific
Min.1.5-inch,min.1.5 pcf Insulfoam FiberBase HD or FiberBase HD Excel,Structodek High Density Fiberboard Roof Insulation or DuraBoard,nominal -180.0
Smooth Surface 0,5-inch APA Rated plywood or APA Rated OSB
Built-Up Roof Min.1.5-inch,min.2.0 pcf Insulfoam or ACFoam 11,ACFoam III, Min.O.5-inch Georgia Pacific FiberBase HD or FiberBase HD Excel or Structodek High Density Fiberboard Roof -202.5
ISO 95+GL,H-Shield,H-Shield CG,ENRGY 3 or Multi-Max FA3 Insulation
Min.1.5-inch,min.2.0 pcf Insulfoam Min.0.25-inch Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or nominal 0.5-inch APA Rated _240.0
plywood or APA Rated OSB
Min.1.5-inch ACFoam 11,ACFoam Iii,ISO 95+GL,H-Shleld,H- Min.0.25-inch Dens Deck,Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board -262.5
Shield CG,ENRGY 3 or Multi-Max FA3
Exterior Research and Design,I.I.C.d/b/a Trinity ERD Evaluation Report 2760.12.03-R8 for.FL1365-R7
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVAI DATION Revision 8:10/12/2017
Prepared by: Robert Nieminen,PE-59166 ICP Adhesives CR-20;(888)774-1419 Appendix 1,Page 5 of 5
MIANH-DADS COUN'T'Y
MIAMK_ .,__ . PRODUCT CONTROL SECTION
fill 11805 S1TJ 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
130ARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF•ACCEPTANCE OA
w ww.miamidade.1av/eeon omy
Entegra Roof Tile,LLC
1289 NE 911'Ave
Okeechobee,FL 34972
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code,
DESCRIPTION: Plantation Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Oficial.
This NOA renews NOA#14-1120.04 and consists of pages 1 through 7.
The submitted documentation was reviewed by Gaspar J Rodriguez.
NOA No:: 15-4721.04
rttaMaflaoEcouNrr Expiration Date: 12/08/20
Approval Date:11/05/15
Page 1 of 7
i
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Roofing Tiles
Material: Concrete
1. PRODUCT DESCRIPTION
Manufactured by Dimensions Test Product
Applicant Specifications Description
Plantation Tile Length: 16'/Z" TAS 112 Flat concrete roof tile for direct deck or
Width: 13" battened nail-on,mortar or adhesive set
applications.
Trim Pieces L=varies TAS 112 Accessory trim,concrete roof pieces for
W=varies use at hips,rakes,ridges and valley
Varying thickness terminations. Manufactured for each tile
profile.
2.1. MANUFACTURING LOCATION
1. Okeechobee,FL
2.2 SUBMITTED EVIDENCE:
Test Agency Test Identifier Test Name/Report Date
American Test Lab of South RT0624.05-14 TAS 112 07/03/14
Florida
Redland Technologies 7161-03 Static Uplift Testing Dec. 1991
Appendix III PA 102&PA 102(A)
The Center for Applied 94-060B Static Uplift Testing March, 1994
Engineering,Inc. 94-084 PA 101 (Adhesive Set) May 1994
(Mortar Set)
Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991
Appendix II PA 108(Nail-On)
Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing Aug. 1994
PA 108(Nail-On)
Redland Technologies P0631-01 Wind Tunnel Testing July 1994
PA 108(Mortar Set)
Redland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993
screw vs.smooth shank nails
The Center-for Applied Project No.307025 Wind Driven Rain Oct. 1994
Engineering,Inc. Test#MDC-76 PA 100
Walker Engineering,Inc. Calculations Aerodynamic Multiplier March 1999
April 1999
Walker Engineering,Ine. Calculations 25-7183 March 1995
25-7094 February 1996
25-7496 April 1996
NOA No.: 15-0721.04
MAMMAD COUtMM Expiration Date:12/08/20
Approval Date:11/05/15
Page 2 of 7
2.2 SUBMITTED L+v1DENCE:
Test Agency Test Identifier Test Name/Report Date
Walker Engineering,Inc. Calculations 25-7584 December 1996
25-7804b-8
25-7804-4&5
25-7848-6
Walker Engineering,Inc. Calculations Two Patty Adhesive Set System April 1999
Farabaugh Engineering and T295-11 TAS-108 10/05/11
Testing Inc.
Farabaugh Engineering and T306-11 TAS-108 10/04/11
Testing Inc.
Farabaugh Engineering and T279-11 TAS-108 09/23/11
Testing Inc.
3.. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami-Dade Product
Control office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3,7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 61 G20-3 of the Florida Administrative Code.
NOA No.:15-0721.04
Mwrtt•naDecourtry Expiration Date: 12/08/20
Approval Date:11/05/15
Page 3 of 7
4. INSTALLATION
4.1 Plantation hoof Tile and its components shall be installed in strict compliance with Roofing Application
- Standard RAS 11 8,RAS 119 and RAS 120.
4,2 Data For Attachment Calculations
Table 1: Average Weight(W) and Dimensions (I x w)
Tile Profile Weight-W(Ibf) Length-[ (ft) Width-w(ft)
Plantation Tile 11.6 1.375 1.08
Table 2: Aerodynamic Multipliers -1(0)
Tile 7.(ft3) X(ft3)
Profile Batten Application Direct Deck Application
Plantation Tile 0.267 0.289
Table 3: Restoring Moments due to Gravity-M (ft-Ibf)
Tile Greater than
Profile 2"• 12" 3"• 12" 4"• 12" 6"• 12" 6"• 12" 7:12„
Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct
Deck Deck Deck Deck Deck Deck
Plantation 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04
Tile -
i
NOA No.:15-0721.04
MIAMI DADS COUNTY Expiration Date:12/08/20
Approval Date: 11/05/15
Page 4 of 7
Table 4: Attachment Resistance Expressed as a Moment-Mf(ft-ibf)
For Nall-On Systems
Tile Fastener Type Direct Deck Direct Deck Battens
Profile (Min 15132" (Min. 19132"
plywood) plywood)
Plantation Tile 2-10d Ring Shank 30.9 38.1 17.2
Nails
1-10d Smooth or 7.3 9.8 4.9
Screw Shank Nail
2-10d Smooth or 14.0 18.8 7.4
Screw Shank Nails
1 #8 Screw 30.8 30.8 18.2
2#8 Screw 51.7 51.7 24.4
1-10d Smooth or 24.3 24.3 24.2
Screw Shank Nail
Field Clip)
1-10d Smooth or 19.0 19.0 22.1
Screw Shank Nail
Eave Clip)
2-10d Smooth or 35.5 35.5 34.8
Screw Shank Nails
Field Clip)
2-10d Smooth or 31.9 31.9 32.2
Screw Shank Nails
Eave Clip)
2-10d Ring Shank 50.3 65.5 48.3
Nails'
1 Installation with a 4"file headlap and fasteners are located a minimum of 2%"from the head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mf(ft-lbf)
For Two Patty Adhesive Set Systems
Tile Profile Tile Application Minimum Attachment
Resistance
Plantation Tile Adhesive 31.33
2 See manufactures component approval for installation requirements.
3 Flexible Products Company TleSond Average weights per patty 13.9 grams.
3M'"2-Component Foam Roof Tile Adhesive AH-160.Average wet ht per patty 8 rams.
Table 6: Attachment Resistance Expressed as a Moment-Mf(ft-lbf)
For Single Patty Adhesive Set S stems
Tile Profile Tile Application Minimum Attachment Resistance
Plantation Tile 31VI'°2-Component Foam Roof Tile Adhesive AH-160 118.94
3M'2-Component Foam Roof Tile Adhesive AH-160 40.45
4 Lar a adly placement of 45 grams of 3M'°2-Component Foam Roof Tile Adhesive AH-160
5 Mediumpaddy add lacement of 24 grams of 31VI'2-Component Foam Roof Tile Adhesive AH-160.
NOA No.: 15-0721.04
MLAM I-DAD;COUNTY Expiration Date:12/08/20
Approval Date: 11/05/15
Page 5 of 7
Table 7:Attachment Resistance Expressed as a Moment- Mf(ft-lbf)
for Mortar Set Systems
Tile Profile Tile Application Attachment
Resistance
Seespecific mortar manufacturer's Notice of Acceptance.
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following
statement: "Miami-Dade County Product Control Approved".
OR
ENTEERR
PLANTATION ROOF TILE LABEL(LOCATED ON UNDERSIDE OI,'TILE)
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
NOA No.:15-0721.04
MIAMI-DAD;COUNTY Expiration Date:12/08/20
Approval Date: 11105/15
Page 6 of 7
7 �
PROFILE DRAWING
PLANTATION FLAT CONCRETE TILE
I6Ii2��
END OF THIS ACCEPTANCE
MIAMI•DADECODU Y
NOA No.: 15-0721.04
Expiration Date: 12/08/20
Approval Date: 11/05115
Page 7 of 7