HomeMy WebLinkAboutBuilding PermitAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: 1/2/20 Permit Number:
COUNTY`
F L O R I D A —'
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578
PERMIT TYPE: PLUMBING
PROPOSED IMPROVEMENT LOCATION:
Building Permit Application
Commercial Residential X
Address: 5841 Honeybell Ct Apt 36D Fort Pierce, FL 34982
Property Tax ID fi: 3410-507-0144-000-5
Site Plan Name:
Project Name: WATER HEATER
DETAILED DESCRIPTION OF WORK:
50- GALLON ELECTRIC WATER HEATER REPLACEMENT
CONSTRUCTION INFORMATION:
Lot No.
Block No.
Additional work to be performed under this permit —check all that apply:
_Mechanical _Gas Tank _Gas Piping _Shutters —Windows/Doors
_ Electric _ Plumbing _ Sprinklers _ Generator _ Roof
Total Sq. Ft of Construction: _
Cost of Construction: $ 2,370.00
Sq. Ft. of First Floor:_
Utilities: _Sewer _Septic Building Height:
Pitch
OWNER/LESSEE: OWNER
CONTRACTOR:
Name George Gannon
Name: RICHARD BASSOFF
Address: 5841 Honeybell Ct Apt 36D
Company: ADMIRAL PLUMBING SERVICES, LLC
City: Fort Pierce, FL State: _
Zip Code: 34982 Fax:
Phone No. 772) 672-4380
Address: 2895 JUPITER PARK DR STE 700
City: JUPITER State: FL
Zip Code: 33458 Fax:
Phone No 561-746-1180
E-Mail: ggannon7@gmail.com
Fill in fee simple Title Holder on next page ( if different
from the Owner listed above)
E-Mail PERTMITTING@THEADMIRALPLUMBER.COM
State or County License CFC-1426115
If value of construction is $2500 or more, a RECORDED Notice of Commencement is required.
If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
DESIGNER/ENGINEER: _ Not Applicable
Name:
MORTGAGE COMPANY: _ Not Applicable
Name:
Address:
Address:
City: State:
Zip: Phone
City: State:
Zip: Phone:
FEE SIMPLE TITLE HOLDER: _ Not Applicable
Name:
BONDING COMPANY: _Not Applicable
Name:
Address:
Address:
City:
City:
Zip: Phone:
Zip: Phone:
OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND
POSTED HE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU 1 D TO OBTAIN FINANCING, CONSULT
WITH YQURIXNDER ORM ATTORNU 13EFQRE RECORDING YOUR N I f)F7 COMMENCEMENT."
E
Signature fOwner/ Less a/Contra 11T6Agent for Owner
Signatur of Cc ntrac or/Lice
older
STATE OF FLORIDA
STATE OF FLORIDA
COUNTY OF PALM BEACH
COUNTY OF PAW BEACH
The forgoing instrument was acknowledged before me
The forgoing instrument was acknowledged before me
this 2 day of AN 20 by
this 2 day of JAN
, 20_ by
RICHARD BASSOFF
RICHARD BASSOFF
Name of person making statement.
Name of person making statement.
Personally Known x OR Produced Identification
Personally Known x OR Produced Identification
Type of I entification
a of Identi 'cation
P uC .J`' ° Notary Public Stale of Honda
d
�Jacqu•line Oeorgescu
GG 233150Jacqueline
Notary Public State of FloridaVI�1110
T)�,
/,�commisalon
empires 09/28/2022
Geof ec'rt'%'
My Commission GG 2331150Expires
08/28/2022
gnat f ota Public- State of Florida)
(Sig ure of Public-
t e`VVI`T NII_ ,^ ^
ommi Ion No. (Seal)
Co mission
(Seal)
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEA TURTLE
MANGROVE
COUNTER
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
DATE
RECEIVED
DATE
COMPLETED
Rev. 21 // 19
PERFORMANCETM
The new degree of comfort:"
PERFORMANCE"' electric water heaters
feature dual copper heating elements
and a six -year warranty
Efficiency
■ ,92 - .93 UEF
■ Isolated tank design reduces
conductive heat loss
■ Dual 380OW or 450OW copper
heating elements depending on unit
Performance
■ FHR: 33 - 62 gallons, based on
gallon capacity
■ Recovery: Up to 21 GPH at a
900 F rise, depending on model —
Longer Life
■ Premium grade anode rod provides
long-lasting tank protection
Features
■ Electric junction box located above
heating elements for easy installation
■ Over -temperature protector cuts
off power in excess temperature
situations
Plus...
■ Temperature and pressure relief valve
included
■ Low lead compliant
Warranty
■ 6-Year limited warranty for tank
and parts, 1-year full in -home labor
warranty'
'See writer, warranty for complete details
Units meet or exceed ANSI requirements aid have
beet tested according to D.O.E. procedures. Units
meet or exceed the energy efficiency requirements
of NAECA. ASHRAE standard 90. ICC Code and all
state energy efficiency performance criteria
PERFORMANCE
20 to 50-Gallon Capacities
240 Volt AC/Single Phase
Double and Single Element Models
See specifications chart on back.
W/li FORM NO. 11IO-PE04 N Rev.
1 1
Tee tiew aegee.1 camf
PERFORMANCE Electric Specifications
. no
Nombw
Ga1m
Generiaeen Oapxft
il,
as m
pmNEa
Model
NWNIar
RArorNF
In GAA
90"FRin
W,;-7HTank
RNaHeigh
GFA
MelpM t.
Wa6er GOWL
a
Diameter
C
Ship Unarm
Weigh Energy EnergVFacm1
IRS.) Fact., (UEF)
TO 5G
45
050I06ST45U1
21
52
58-7,a
51-W
-
Mnmum
5Z
45
RE50MG63T45U1
21
62
48
M-12
23
132
0 95
U93
Shin
47
43
%E41S8MST45U0
21
M
32
34
ffi 114
169
0.95
0.93
hall
40
M
XE40TO65145UI
21
52
60-3/4
63-58
194f4
109
0.95
0.93
Medium
40
35
o4GMdGST45d1
21
51
M-114
50-t/2
20-V4
106
0.95
0.93
Meditea
40
36
%F40M05ST38U1
I]
42
48-1/4
5D12
20-1/4
106
0.95
0.32
5hitl
38
35
X-38S06ST4$01-
21
54
31-112
32-516
23
IN
Ulm
0,93
Short
38
W
%E38506ST38U1'
12
34
311/2
32-51
23
to
195
0.92
Sian
36
33
XF36S06ST45U0
21
0
31-1/2
33
24-1/4
118
0.0
0.92
Stan
36
33
a3ES06ST36110
17
34
31-1/2
33
24-114
118
0.95
0.92
Tall
30
22
xE30T065T45111
21
68
42-1 2
50-318
19-114
92
0.95
0.92
Tam
30
22
U3010ST38UI
12
36
47 V2
50-3.1
19-IM
92
095
022
Medeim
W
r
9104106ST4 N
21
45
31-112
40-12
2 114
92
ass
am
Shcn
30
V
AE305065i45V1-
21
43
30
n
19-Y4
95
0.95
022
Said
30
22
NEWS06STMUl'
12
33
30
32
19-Y4
95
0,95
(192
Shin
28
S
AE25S06ST45UG
1 21
43
30
31-119
23
%
0.95
0.92
Shin
28
2i
AF2HMT38UO
12
M
30
31-118
23
95
095
0.92
short
20
WA
)(F20SMT38U0
12
WA
31-12
31-12
12
62
WA
WA
"Hater heater tint¢nx;AS nntor to reasoning irt4yyiC{1 tY3n49?Mattis minioed w4th'.vatY Thainer. The Gankat antle 1- 112 indieS TO?ar4 height
S'd 2 inCMS to ta"k bdnet9, M000t Mi —fib. LtVS oT45Ul: Ine Clarlket Was 5 u1Cha510 tank Qame-er.
Uniform Energy Factor anO E �rgr Fagor tusai m Rrou'i �rt pt @argy ID.O.E.I mn4a0rnents.
• liea¢as Rum sle wan stani 210 vd1 AC_ ssx¢ wiring, and A ioo watt upper aria bwer hwvhng eknmlts.
•.gl «gddla eOwpDod u4th last tra(s.
"RKG,,Gly = walteige,2,42 x Ring. rse'E. "R%'over/ = waI page/2.42 x to lu. nw `F.
3w,pla. 450001 = 21 G=H Euermle' 3803W = 17 GFH
2.42 x P- 2.42 x 90'
-Rece'/e^V cia:V ho,,s used are betao W4 00 Wart ahaiva'!te'xed n nIXl-$in4lhar?liL7' ooerit
8"
HOT
WATER ® COLD
CONNECTION WATER
RWEF VALVE CONNECTION
CONNECTION ANODE
ROD
C�
OIAMETER I
i�
_l
WATER CONNECTIONS ALL 3r4" N.P.T.
In keeping with its poky of continuous progress and product improvement, Fheeln reserves the night to make Changes without notice.
Rheem Water Heating a 101 Bell Road
Montgomery. Alabama 36117-4305 a www.rheem.com
04/17 FORM NO. THPPE06 N Rev.3