FL# FL24221
New U U dGi
Application Type e) A � ( --
Code Version 2017 41-1-1
Application Status Approved
REVIEWED Fu
Comments CODE COMPLIANCE
Archived p
ST. L.UCIE COUNTY
Product Manufacturer Dynamic Metals ����
Address/Phone/Email 3201 SE Dominica Terace
Stuart,FL
34997
(772)872-80308030
jean@dynamlcmetal.Ret Z�
Authorized Signature Juan Martinez
juan@dynamicmetal.net
Technical Representative
Address/Phone/Emall File Copy
i
Quality Assurance Representative
Address/Phone/Email
Category =Rofing
Subcategory
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Pedro De Figueiredo,P.E.
the Evaluation Report
Florida License PE-52609
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 12/06/2026
Validated By Gary Hartman
Validation Checklist-Hardcopy Received
Certificate of Independence FL24221 RD COI R17-296 C1.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM B117 2011
ASTM G155 2005
TAS 100 1995
TAS 125 2003
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL24221 RO Eauiv B117-11 to-16 odf
Sections from the Code
hffps://www.floridabuilding.org/pr/pr_app_.dti.aspx?param=wGEVXQwtDquUsDrhuM3DGM%2bmi7wFtl3%2fYFSE6n3NwN%2bZFHJBIBchAw%3d%3d 1/3
Product Approval Method Method 1 Option D
Date Submitted 10/20/2017
Date Validated 10/20/2017
Date Pending FBC Approval 10/26/2017
Date Approved 12/12/2017
Summary of Products
1 Fl.# 1 Model,Number or Name Description
i24221.1 Dynamic Metals I"Nallstrip(26 Ge I"Nallstrip,26 Ga Galvalume Steel,Non-structural roof panel
Steel)
I Limits of Use Installation Instructions
Approved for use in HVHZ-No FL24221 RO 11 17-296.10 DWG,odf
Approved for use outside HVHZ:Yes Verified By: Pedro De Figueiredo,P.E.52609
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-131.0 Evaluation Reports
Other.,Maximum fastener spacing 6"o/c FL24221 RO AE R17-296 10.od
Created by Independent Third Party:Yes
24221.2 Dynamic Metals 1-1/2"Mechanical 1-1/2"Mechanical Seam,0.032"Aluminum,Non-structural
(Aluminum) roof panel
Limits of Use Installation Instructions
Approved for use in HVHZ*Yes FL24221 RO 11 17-296.02 DWG.od
Approved for use outside HVHZ:Yes Verified By: Pedro De Figueiredo,P.E.52609
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-198.5 Evaluation Reports
Other:-198.5 psf at maximum clip spacing 10-1/211 o/c FL24221 RO AE R17-296 2.pdf
-179.8 psf at maximum clip spacing 13"o/c Created by Independent Third Party:Yes
24221.3 Dynamic Metals 1-1/2"Mechanical 1-1/2"Mechanical Seam,24 Gauge Galvalume Steel,Non-
1(24 Ga Steel) structural roof panel
Limits of Use Installation Instructions
Approved for use in HVHZ.Yes FL24221 RO 11 17-296.04 DWG.Pdf
Approved for use outside HVHZ:Yes Verified By: Pedro De Figueiredo,P.E.52609
Impact Resistant, N/A
Created by Independent Third Party;Yes
Design Pressure:+N/Al-171.0 Evaluation Reports
Other:Maximum clip spacing 13"o/c FL24221 RO AE R17-296 4.pd
Created by Independent Third Party:Yes
24221.4 j Dynamic Metals 1-1/2"Mechanical 1-1/2"Mechanical Seam,26 Gauge Galvalume Steel,Non-
(26 Ga Steel) structural roof panel
Limits of Use Installation Instructions
Approved for use In HVHZ:Yes FL24221 RO 11 17-296.05 DWG,gdf
Approved for use outside HVHZ:Yes Verified By: Pedro De Figuelredo,P.E.52609
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-221.0 Evaluation Reports
Other:Maximum clip spacing 12"o/c FL24221 RO AER17-296 5.12d
Created by Independent Third Party:Yes
24221.5 Dynamic Metals 1-1/2"Mechanical 1-1/2"Mechanical Seam, 16 Oz Copper,Non-structural roof
(Copper) panel
Limits of Use Installation Instructions
Approved for use in HVHZ.Yes FL24221 RO 11 17-296.06 DWG.r)d
Approved for use outside HVHZ.Yes Verified By: Pedro De Figueiredo, P.E.52609
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A"`/-198.5 Evaluation Reports
Other:-198.5 psf at maximum clip spacing 12"o/c-153.5 psf FL24221 RO AE R17-296 6,12df
at maximum clip spacing 1511 o/c Created by Independent Third Party: Yes
24221.6 Dynamic Metals 1-3/4"Snaplock 1-3/4"Snaplock,0.032"Aluminum,Non-structural roof panel
(Aluminum) I
Limits of Use i Installation Instructions
Approved for use In HVHZ:Yes FJ-24221 RO 11 17-296.09 DWG.od
Approved for use outside HVHZ:Yes Verified By: Pedro De Figueiredo,P.E.52609
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/Al-228.5 Evaluation Reports
LaOther:-228.5 psf at maximum clip spacing 9"o/c-168.5 psf I FL24221 RO AE R17-296 9,pdf
t maximum clip spacing 1911 o/c Created by Independent Third Party:Yes
124221.7 Dynamic Metals 2"Mechanical 2"Mechanical Seam,0.032"Aluminum,Non-structural roof
hftps://www.floridabuilding.org/pr/pr_appjtl.aspx.?param--WGEVXQWtDquUsDrhuM3DGM-%2bml7wFtl3%2fYFSE6n3NwNO/*2bZFHJBI BchAw1/'G3d%3d 2/3
Florida Building Code Online
(Aluminum) panel
Limits of Use Installation Instructions
Approved for use In HVHZ:Yes FL24221 RD 11 17-296.01 DWG.Ddf
Approved for use outside HVHZ:Yes Verified By: Pedro De Figueiredo, P.E.52609
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure.+N/A/-206.0 Evaluation Reports
Other:-206.0 psf at maximum clip spacing 9"o/c-202.3 psf FL24221 RO AE R17-296 1.0df
at maximum clip spacing 19"o/c Created by Independent Third Party:Yes
24221.8 Dynamic Metals 2"Mechanical(24 2"Mechanical Seam,24 Gauge Galvalume Steel, Non-
Ga Steel) structural roof panel
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL24221 RO 11 17-226.03 DWG,od
Approved for use outside HVHZ:Yes Verified By: Pedro De Figuelredo, P.E.52609
Impact Resistant.N/A Created by Independent Third Party*Yes
Design Pressure:+N/A"`/-228.5 Evaluation Reports
Other:-228.5 psf at maximum clip spacing 9"0/c-194.8 psf FL24221 RO AE R17-296 3.pdf
at maximum clip spacing 19"o/c Created by Independent Third Party:Yes
24221.9 Dynamic Metals 5V Crimp(26 Ga 5V Crimp,26 Gauge Galvalume Steel,Non-structural roof
I Steel) panel
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL24221 RO 11 17-296.07 DWG.odf
Approved for use outside HVHZ.-Yes Verified By: Pedro De Figueiredo,P.E.52609
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-243.5 Evaluation Reports
Other:-243.5 psf at maximum fastener spacing 8"o/c-142.3 EL24221 RQ AER17-296 7.pdf
psf at maximum fastener spacing 16"o/c Created by Independent Third Party:Yes
7--a.
24221.10 Dynamic Metals 5V Crimp 5V Crimp,0.032"Aluminum, Non-structural roof panel
C11(Aluminum)
Limits of Use :i Installation instructions
Approved for use In HVHZ:Yes FL24221 RO 11 17-296.08 DWG.od
Approved for use outside HVHZ: Yes Verified By: Pedro De Figueiredo, P.E.52609
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-183.5 Evaluation Reports
Other:-183.5 psf at maximum fastener spacing 8"O/C-119.8 FL24221 RO AE R17-296 S.ndf
psf at maximum fastener spacing 16"o/c iCreated by Independent Third Party:Yes
Contact Us::MI Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.*.:Privacy Statement::Accessibility Statement :Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact$50.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have
one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,KS,
please click here.
Product Approval Amepts.
r—==rT�-I
LM Fi;'r_t R91
Credit Card
Safe
https://Www.floridabuilding.org/pr/pr_app jU.aspx?parem--wGEVXQwtDquUsDrhuM3DGM�/�2bml7wFtl3*/�2fYFSE6n3NwN%2bZFHJBIBchAw�/�3d�/�3d 3/3
DRAWINGS #: 17-206.8
REPORT: 17-29G,5
POOF DFC.F,,
11-1111.111 �.IIUH 15/-L
4-PL)" CD r': PL"(WOOD '---:HEATII-,K)
FA I'%]E L M 111 D L E RI E?
PANEL OVERLAP--//
# 10- 1 - 1 /12"' WOODZZ-AC HILO HWH
,-PACEL., Al AT FIELD Akll)
P6 F D 6T R F.]F A r c.n F-,,t\i F,-
140. 512�09
STAIE
ORID
DRAWIhJG5 #: 17-296.8
REPORT: I —296,8
r
DYNAMIC 5V CRIMP
0.032 ALUMINUM PANEL
lot
,..Ilio::•-��:.
' 3CE S r
*
NO. 52 9
. - STATE
�'��:'•FIDAI'D .. .: