Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wG... Business & u� Prokssional Regulation BCIS Home I Login User Registration I Hot Topics ( Submit Surcharge Stats&Facts I Publications I Contact Us BCIS Site Map I Links Search b a wt-� F, L Product Approval j.USER:Public User d Product pproval Menu>Product or Application Search>Application List>Application Detail FL# FL10497-R6 Application Type Revision Code Version 2017Application Status Approved L:aj Comments Archived ❑ Product Manufacturer Mule-Hide Products Co.,Inc. Address/Phone/Email 1195 Prince Hall Dr Beloit,WI 53511-5481 (608)365-3111 Ext 809 lindar@nemoetc.com Authorized Signature Timothy McFarland lindar@nemoetc.com Technical Representative Tim McFarland —��Z� Address/Phone/Email 1195 Prince Hall Dr R G i/1"EOW(V ED FOR Suite A Belot,WI 535115481 CODE COMPLIANCE (608)365-3111 tim.mcfarland@mulehide.com ST, LUCIE'�+�COUNTY Quality Assurance Representative BOCC Address/Phone/Email Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 09/13/2021 Validated By John W.Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL10497 R6 COI 2017 01 COI_Nieminen.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D6163 2008 ASTM D6164 2011 ASTM D6222 2011 FM 4470 2012 FM 4474 2011 Equivalence of Product Standards Certified By File Cop) 1 of 2 1/9/2020,4:28 PM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?paratn=wG... Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/11/2017 Date Validated 09/13/2017 Date Pending FBC Approval 09/21/2017 Date Approved 12/12/2017 Summary of Products FL* Model,Number or Name Description 10497.1 Mule-Hide SBS and APP Modified Self-adhering modified bitumen roof systems Bitumen Roof Systems Limits of Use Installation Instructions Approved for use in HVHZ:No FL10497_R6 II 2017 09 FINAL Al ER MULE- Approved for use outside HVHZ:Yes HIDE_FL10497-R6.pdf Impact Resistant:N/A Verified By: Robert Nieminen PE-59166 Design Pressure:+N/A/-480 Created by Independent Third Party:Yes Other: 1.)The design pressure in this application relates to Evaluation Reports one particular assembly over concrete deck.Refer to the ER FL10497_R6 AE_2017_09 FINAL ER_MULE-HIDE_FL10497- Appendix for other systems and deck types.2.)Refer to ER, R6.Ddf Section 5 for other Limits of Use. Created by Independent Third Party:Yes Back Next Contact Us::7601 Blair Stone Road,Tallahacc F 127199 Phone:850-487-1824 The State of Florida is an AA/EEO employer.C2p_ydght 2007-2013 State of Florida.::Privacy.Statement::Accessibility.Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.if you do not wish to supply a personal i address,please provide the Department with an email address which can be made available to the public.T6 determine If you are a licensee under Chapter 455,F.S., please click here_. Product Approval Accepts: i Credit Card I Safe 2 of 2 1/9/2020,4:28 PM EXTERIOR RESEARCH&DESIGN,I.I.C. (_)0 Certificate of Authorization#19503 TRINITY I ERD 353 Christian Street Oxford,Ci 06478 (203)262-9245 EVALUATION REPORT Mule-Hide Products Co.,Inc. Evaluation Report M10000.03.08-116 1195 Prince Hall Drive,Suite A FL10497-R6 Beloit,WI 53511 Date of Issuance:03/28/2008 (608)365-3111 Revision 6:09/08/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6u'Edition(2017)Florida Building Code sections noted herein. DESCRIPTION: Mule-Hide SBS and APP Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPUANCE:This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded by the words"Trinity I ERD Evaluated"may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5,plus a 22-page Appendix. Prepared by: OF;:W: Robert J.M.Nieminen,P.E. The(aaimileseal appearing wasauhor¢ed by Robert Nieminen, Florida Registration No.59166,Florida DC4 ANE1983 P.E.on 09108/2017.This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research&Design,I.I.C.d/b/a Trinity I ERD does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research &Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY I ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Modified Bitumen Roof Systems Compliance Statement: Mule-Hide SBS and APP Modified Bitumen Roof Systems, as produced by Mule-Hide Products Co., Inc., have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4474 2011 1504.7 Impact FM 4470 2012 1507.11.2 Physical Properties ASTM D6163 2008 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 3. REFERENCES: Knifty Examination Reference Date ERD(TST6049) Physical Properties P10490.10.08-2 10/30/2008 ERD(TST6049) FM 4470/4474 P13760.09.09 09/10/2009 ERD(TST6049) FM 4470/4474 P13770.09.09 09/10/2009 ERD(TST6049) FM 4470/4474 P30540.11.09-R1 11/30/2009 ERD(TST6049) FM 4470/4474 P30550.12.09 12/02/2009 ERD(TST6049) Physical Properties P33960.12.10 12/30/2010 ERD(TST6049) FM 4470/4474 P33970.03.11 03/15/2011 ERD(TST6049) Physical Properties P37590.03.13-3A 03/06/2013 ERD(TST6049) FM 4470/4474 P39680.03.13 03/04/2013 ERD(TST6049) Physical Properties P37590.03.13-1-R1 06/26/2013 ERD(TST6049) Physical Properties P37590.03.13-2-R1 07/01/2013 ERD(TST6049) Physical Properties P37590.07.13-2 07/01/2013 ERD(TST6049) Physical Properties P37590.03.13-5-R1 07/01/2013 ERD(TST6049) Physical Properties P37590.07.13-1 07/02/2013 ERD(TST6049) FM 4470/4474 P41630.08.13 08/06/2013 ERD(TST6049) Physical Properties P45940.09.13 09/04/2013 ERD(TST6049) Physical Properties P44370.10.13 10/04/2013 ERD(TST6049) FM 4470/4474 SC6160.11.14 11/10/2014 ERD(TST6049) Physical Properties SC5170.05.15 05/08/2015 ERD(TST6049) FM 4474 SC8085.05.15 05/19/2015 ERD(TST6049) FM 4470/4474 SC8905.15 11/24/2015 FM Approvals(TST1867) FM 4470 2W7A7.AM 08/04/1994 FM Approvals(TST1867) FM 4470 0D3A3.AM 04/04/1997 FM Approvals(TST1867) FM 4470 2DOAO.AM 12/23/1998 FM Approvals(TST1867) FM 4470 2D5A9.AM 06/22/1999 FM Approvals(TST1867) FM 4470 3006646 01/04/2000 FM Approvals(TST1867) FM 4470 3001334 01/25/2000 FM Approvals(TST1867) FM 4470 3001334 02/15/2000 FM Approvals(TST1867) FM 4470 3000857 01/12/2000 FM Approvals(TST1867) FM 4470 3004091 01/12/2000 FM Approvals(TST1867) FM 4470 3006115 05/02/2001 FM Approvals(TST1867) FM 4470 3012321 07/29/2002 FM Approvals(TST1867) FM 4470 3014692 08/05/2003 FM Approvals(TST1867) FM 4470 3014751 08/27/2003 FM Approvals(TST1867) FM 4470 3007170 01/13/2004 Exterior Research and Design,I.I.C. Evaluation Report M30000.03.08-116 CertiTicate OfAuthorizatfon 49503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10497-R6 Mule-Hide Modred Bitumen Roof Systems;(608)365-3111 Revision 6:09/08/2017 Page 2 of 5 TRINITY l ERD Enti Examination Reference Date FM Approvals(TST1867) FM 4470 3019317 06/30/2004 FM Approvals(TST1867) FM 4470 3020703 07/30/2004 FM Approvals(TST1867) FM 4470/4474 3018332 01/31/2006 FM Approvals(TST1867) FM 4470/4474 3023368 03/20/2006 FM Approvals(TST1867) FM 4470/4474 3024594 05/23/2006 FM Approvals(TST1867) FM 4470/4474 3023458 07/18/2006 FM Approvals(TST1867) FM 4470/4474 3030668 09/12/2007 FM Approvals(TST1867) FM 4470/4474 3032172 06/12/2009 FM Approvals(TST1867) FM 4470/4474 3049631 04/21/2014 PRI(TST5878) Physical Properties PUSA-062-02-01 12/04/2007 PRI(TST5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI(TST5878) Physical Properties PUSA-064-02-02 02/27/2008 PRI(TST5878) Physical Properties PUSA-062-02-02 12/04/2008 Miami-Dade(CER1592) HVHZ Compliance Various NOAs Various Miami-Dade(CER3592) Proposal for Review 10-0823 10/12/2010 UL LLC(QUA9625) Quality Control ML File No.R13850 09/23/2015 UL LLC(QUA9625) Quality Control Service Confirmation Exp.10/06/2018 4. PRODUCT DESCRIPTION: This Evaluation Report covers Mule-Hide Modified Bitumen Roof Systems installed in accordance with Mule-Hide Products Co.,Inc.published installation instructions and the Limitations/Conditions of Use herein. The following membranes make up the subject systems. ' TABLE 1:ROLL-GOODS FOR MULE-HIDEMODIFIED BITUMEN ROOF SYSTEMS Type Product Specification Reference Grade Type Nail Base ASTM D6163 S I SA Base Sheet ASTM D6163 S I SBS Membranes SA Base Sheet(FR) ASTM D6163 S I SA-SBS Cap Sheet ASTM D6164 G I SA-SBS Cap Sheet(FR) ASTM D6164 G I APP Torch Base ASTM D6509 N/A N/A APP Torch S ASTM D6222 5 I APP Torch G ASTM D6222 G I APP Torch KoolCap G ASTM D6222 G I APP Membranes APP Torch G FR ASTM D6222 G I APP Torch KoolCap G FR ASTM D6222 G I SA-APP Cap Sheet ASTM D6222 G I SA-APP KoolCap G ASTM D6222 G I SA-APP Cap Sheet(FR) ASTM D6222 G I SA-APP KoolCap G FR ASTM D6222 G I Exterior Research and Design,U.C. Evaluation Report M30000.03.08-116 Certowte of Authorization#9503 6TxEDITION(2017)FBC NON-HVHZ EVALUATION FL10497-R6 Mule-Hide Modred Bitumen Roof Systems;(608)365-3111 Revision 6:09/08/2017 Page 3 of 5 TRINITY I ERD S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity]ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations,foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations,the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip-bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD3,FM Loss Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk' carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re-roof(tear off)or recover installation,the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question,field uplift testing in accordance with ANSI/SPRI IA-1,ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing in accordance with ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment(except gutters),shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 610320-3. Exterior Research and Design,U.C. Evaluation Report M10000.03.08-R6 [ervTscate ofAuthorizauon#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10497-116 Mule-Hide Modred Bitumen Roof Systems,(608)365-3111 Revision 6:09/08/2017 Page 4 of 5 TRINITY I ERD 6. INSTALLATION: 6.1 Mule-Hide Modified Bitumen Roof Systems shall be installed in accordance with Mule-Hide Products Co.,Inc. published installation instructions,subject to the Limitations/Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).Refer to FBC 1609 for determination of design wind loads. 6.3 Any FBC Approved coating listed for use with SBS or APP modified bitumen may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements 9. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(314)578-3406,k.chancellor@us.ul.com -THE 22-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Report M10000.03.08-R6 CertiTicote ofAuthorkatlon#9503 6Tx EDITION(2017)FBC NON-HVHZ EVALUATION F1.10497-116 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Revision 6:09/08/2017 Page 5 of 5 TRINITY I ERD APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 4 1B-1 Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 4 18-2 Wood New,Reroof(Tear-Oft)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5 1C Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 6 SD Wood New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 7 1E-1 Wood New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet(nails),Bonded Roof Cover 8 1E-2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 9 IF Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 9 2A Steel or Conc. New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 10 2B Steel or Conc. New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 11 3A Concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 12-14 3B Concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 14 4A LWIC New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 15-16 4B LWIC New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 16 4C LWIC New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 17-18 SA CWF New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 19 SB CWF New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 19 SC CWF New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 19 6A Gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 20 6B Gypsum Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 21 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 21-22 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation/base sheet fasteners shall be of sufficient length for the following deck engagement: ➢Wood: Minimum 0.75-inch penetration. ➢Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted,insulation may be any one layer or combination of polyisocyanurate,polystyrene,wood fiberboard,perlite,gypsum-based roof board or mineral-wool roof board that meets the QA requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. 4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D(mechanically attached base sheet,bonded roof cover),whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck.The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. S. Preliminary insulation attachment for System Type D:Unless otherwise noted,refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29(January 2016). Exterior Research and Design,U.C.d/b/a Trinity l ERD Evaluation Report M30000.03.08-R6 for FL30497-R6 Certificate of Authorization#9503 EDITION(2017)FBC NON-HVH2 EVALUATION Revision 6:09/08/2017 Prepared by:Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 1 of 22 TRINITY I ERD 6. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢Hot asphalt: Full coverage at 25-30 lbs/square. D Dow Insta-Stik Roofing Adhesive(D-I5): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c. ➢Millennium One Step Foamable Adhesive(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. ➢OMG OlyBond 500(OB500): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c.(PaceCart or SpotShot).Nate:OlyBond Green maybe used where OlyBond 500 is referenced. ➢OlyBond Classic(OB Classic): Full coverage at 1 gal/square. ➢ICP Adhesives CR-20: Continuous 2.5-3.5-inch wide ribbons,12-inch o.c. ➢Note:When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,board%oints shall be staggered. ➢Note:The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted,all insulations are flat stock or taper board of the minimum thickness noted.Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'Increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table: ➢Millennium One Step Foamable Adhesive(M-OSFA): MDP -157.5 psf (Min.0.5-inch thick) ➢OMG OlyBond 500(OB500): MDP -45.0 psf (Min.0.5-inch thick Multi-Max FA-3) ➢OMG OlyBond 500(OB500): MDP -187.5 psf (Min.0.5-inch thick ISO 95+GL) ➢OMG OlyBond 500(OB500): MDP -315.0 psf (Min.0.5-inch thick ENRGY 3) ➢OMG OlyBond 500(OB500): MDP -487.5 psf (Min.0.5-inch thick ACFoam II,Poly ISO 2) ➢ICP Adhesives CR-20: MDP -117.5 psf (Min.1.0-inch thick) 8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16,and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD3,FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117.Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 10. For assemblies with all components fully bonded in place,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no rational analysis is permitted. 11. For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system.Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For existing substrates in a bonded recover or re-roof installation,the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system(for recover)shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing in accordance with ANSI/SPRI IA-1,ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For Recover Applications using System Type D,the insulation is optional;however,the existing roof system shall be suitable for a recover application. 14. Lightweight Insulating Concrete(LWC)shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced,refer to current LWC Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1. Exterior Research and Design,U.C.d/b/a Trinity)ERD Evaluation Report M10000.03.08-R6 for FL30497-R6 Certificate of Authorization#9503 0 EDITION(2017)FBC NON-HVHZ EVALUATION Revision 6:09/08/2017 Prepared by:Robert Nieminen,PE-59166 Mule-Hide Modred Bitumen Roof Systems;(608)365-3111 Appendix 1,Page 2 of 22 . TRINITY I ERD TABLE 1C:WOOD DECKS—NEW CONSTRUCTION,REROOFTEAR-OFF)OR RECOVER SYSTEMTYPEC:MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Top Insulation layer Roof Cover(Note 15) (P steNo. Deck(Note 1) Base Insulation layer MDP Type Fasten Attach Base Ply Ply Cap TORCH-APPUED BASE PLY: - Dekfast Hex Plates with Dekfast 1114, Min.inch (Optional)One or more Min.0.25-inch Dens Deck OMG 3"Round Metal Plate with OMG 1 per 2 W-10 inch plywood layers y combination, lRoof Board HO,ROCK MG Fl p Bot or TPI t i(Ac Metal ) ft, APP-TA (Optional)APP-TA APP-TA -30.0 loose laidGypsum-Fiber Insulation Plate with Trufast HD. SELF-ADHERING BASE PLY: Dekfast Hex Plates with Dekfast 1114, Min.15/32- (Optional)One or more Min.0.25-inch Dens Deck OMG 3"Round Metal Plate with OMG 1 per 2 585-SA,APP-SA, W-11' layers,any combination, Prime or SECUROCK HD,OMG Flat Bottom Plate(Accutrac) z SBS-SA (Optional)SBS-SA,APP-TA -30.0 inch plywood loose laid Gypsum-Fiber Roof Board with Roofgrip 1114 or Trufast 3"Metal ft APP TA Insulation Plate with Trufast HD. (Optional)One or more Dekfast Galvalume Steel Hex with Dekfast W 12 in.19/32- layers,any combination, Min.1.5-inch ENRGY 3,H- 1112 DP or Mule-Hide 3"Insulation Plate 1 per SBS-SA (Optional)SBS-SA,APP-TA SBS-SA,APP SA, -82.5 I h plywood loose laid Shield,Poly ISO 1,Poly herrn with Mule-Hide Drill Point Fastener 1.33 ft APP-TA Exterior Research and Design,LIG d/b/a Trinity)ERD Evaluation Report M10000.03.08-R6 for FL30497-R6 Certificate of Authorization 119503 6TH EDITION(2017)FBC NON-HVH2 EVALUATION Revision 6:09/08/2017 Prepared by:Robert Nieminen,PE-59166 Mule-Hide Modified Bitumen Roof Systems,(608)365-3111 Appendix 1,Page 6 of 22 PRODUCTS Y• PRODUCT DESCRIPTION The Mule-Hide Poly ISO I'm polyisocyanurate insulation (fiat or tapered)Is a closed-cell polylsocyanurate foam core laminated to(non-asphaltic)glass fiber reinforced felt'facers. The Mule-Hide Poly ISO 1 is compatible with all Mule- Hide membranes and accessories.Available in 20 psi and 25 psi. BASIC USES The Mule-Hide Poly- ISO 1 TM insulation,board may be used for ballasted, mechanically attached and fully adhered single-ply rooting systems. The Poly ISO 1 Tr" insulation board may be installed over approved decks and substrates on new construction,tearoffs,and recover(retrofit) projects. The Poly ISO 17M insulation board may be used in UL Ciass A and FM Class 1 assemblies. BENEFITS&SUPPLEMENTAL STATEMENTS • Approved for direct application to steel decks • Mule-Hide Poly iSO 1*is manufactured with NexGen Chemistry: Contains no CFCs, HCFCs,is Zero OQP, EPA Compliant and has virtually no GWP • Available as 4'x 4'or 4'x 8'panels in Grade 2(20 psi)or Grade 3(25 psi) RECEIV o • Thicknesses range from 1"to 4.5" 4 2019 JAN 1 • - TYPiCAL PHYSICAL PROPERTIES l.ude Coun tyr permltdng 11�111:di 14 1110i! Dimensional Stabil' ASTM D-2126 2%Linear Chane 7 da Compressive Strength ASTM D-1621 20 PSI Grade 2 25 PSI Grade3 Water Absorption ASTM D-209 Less than 1%By Volume Moisture Vapor Transmission ASTM E-96 Less than One 1 Perm Service Temperature --- -100°F to 250°F Max Flame Spread foam core ASTM E 84 <75" Smoke Development ASTM E 84 <450** j *The physical properties above are presented as typical average'velues as determined by accepted ASTM test methods and i are subject to change. All Information can be confirmed by contacting Mule-Hide Products. "The numerical ratings are determined by ASTM Test Method E-84 are not intended to reflect hazards presented by this or any other material under actual fire conditions. A flame spread index of 75 or less and smoke development of 450 or less meet code requirements regarding flame spread and smoke development for foam plastic roof insulation.However,the codes exempt foam plastic insulation when used In roof deck constructions that comply as an assembly with FM 4450 or UL 1256(see IBC,NBC, UBC and SBS Sections on Foam Plastic insulation(Chapter 26). Smoke development does not apply to roofing PolylSO TM Recycle Content 20 2 layers of 1.8"Poly iSO Between 16%and 43%by weight,depending upon 25 '2 layers of 2.2"Poly ISO thickness(55%post consumer and 45%post industrial). 30 2 layers of 2.6"Poly ISO Refer to Mule-Hide LEED memo. 35 21a ers of-3.1"Po 1S0 40 2 layers of 3.5"Poly ISO Revised:March-2017 PDS 09-6210 Page 1 of 3 Product Data Sheet MULE-HIDE POLY IS01 TM ROOF INSULATION mig, um TYPICAL PHYSICAL PROPERTIES(Continued) E 'r 1.0 25 1 5.7 .175 2% 1.5 38 8.6 .116 4% 1.8 46 10.3 .097 4% 2.0 51 11.4 •088 4 sf 2.5 64 14.4 .069 4% 2.6 66 15.0 .067 41 3.0 76 17.4 .057 4% 3.5 89 20.5 .049 4% 3.8 97 22,3 .045 4% 4.0 102 23.6 .042 4% 4.3 109 25.5 .039 4'f 4.5 114 26.8 1 .037 4'%/., .Long Term Thermal Resistance Values are based on ASTM 01289(revised Jan-2014)and CAN11.11_C S770 which provides for a 15•yeartime weighted average. *Other thicknesses available upon special request. SUPPLIMENTAL INFORMATION ._.__ o-_-::_• stf»MYeYr9if.YYr�aY�osw�rss.SlsY.lM.r Yrsn�srY?•RYrrMMYY}R�y...Y��rYrfrr•roYRr.Yf, 7. .. ...::.... .._'_„u.rte;-_.•:-`:..'-:.”. _ r _ A- n•:.:. ..... ::.... .!'...':,::'':}_.is ' :a. :,:5 .... .•:-:..: _g. rte. ._.: ..Vii» :.p;[g :a.:S.w - �O'-'S:,_ :1•d5,'• - 2iiY5f';> ;TAAi t:' ��• - X::r :Y:c.' j':-%.1:F -,Y.1`.` >t - - - - r r r 4 ! ✓.c e ^• t - _ J :._..:. • .i.•ate• .. .. C _ r .v •5: i 4.. _ _ r • r:•.:. ....,. „ :�,...-. cSCic_'.,. ... .:. .... .... .:....t; •�L= _ .•:_2.0'•';'I�O�' '� — '�Y.i.: 2.�p�: iS0 •. ME !JJ AJi IYYLJ Y�►I.YYY�.Y.11.r.AA'�J:[OiYiJ`il.YIY Yl11LCY1YY.JY itY►iJ i•YY IY.AJi:lliYl�llYril Y\414.•Iiil\ 1.i i YM.LY 11Y Yi}Y.i.YlY1YJ.aYYY i Y11►i 11111•tlr PACKAGING Factory applied packaging is only intended for protection during transit.When stored outside or at the job site, the Insulation must be stored at least 4"above ground level and completely covered with a weatherproof covering such as a tarpaulin. Waming-Do Not Leave Exposed:This product will bum if exposed to an ignition source of sufficient heat and intensity,or an open flame. CODE APPROVALS/COMPLIANCE Poly ISO 1 Tm complies with the requirements of the following specifications,test and code requirements when properly installed. *Federal Specification HH-1-19721GEN and HH-1-197212,Class 1 *ASTM C 1289-05a,Type ll,Class 1,Grade 2(20 psi),Grade 3(25 psi) *FM Standard 4450/4470 Approval,Class 1 *UL Standard 1256 Classification Page 2 of 3 PDS 09-6210 Revised March-2017 Product Data Sheet MULE-HIDE POLY 1801 TM ROOF INSULATION CODE APPROVALSICOMPLIANCE(continued) *UL Standard 790 Classification •UL Standard 263 Fire Resistance Classification INSTALLATION INSTRUCTIONS Ballasted Single-Ply Membrane Systems-Mule-Hide Poly ISO 17m does not require attachment to the deck in this system.All boards must be tightly fitted together to prevent movement,separation or damage during the Instal lation of the membrane system.All gaps greater than 1/4"must be filled.After the membrane is Installed, sufficient amounts of ballast must be applied to prevent membrane and Insulation movement.Refer to the Mule- Hide Manual and FMLoss Prevention Data Sheet 1-29 for information regarding ballasting guidelines. Mechanically Attached Single-Ply Membrane Systems—Mule-Hide.Poly ISO 1 TM should be attached with Mule-Hide fasteners and insulation plates(or FM Approved fasteners)using a minimum of 4 fasteners per 4'x 4' ! board (1 fastener per 4 square feet)and a minimum of 6 fasteners per 4'x 8'board(1 fastener per 5.33 square i feet). Refer to the Mule-Hide Manual for proper fastener placement. i Fully Adhered Single•Ply Membrane Systems-Mule-Hide Poly ISO IM should be installed with the perforated side down:Insulation attachment will vary depending upon insulation thickness and job requirements. If the top layer is less than 2"thick,install a minimum of 8 fasteners per 4'x4'board(1 fastener per 2 square feet)and a minimum of 16 fasteners per 4'x 8'board(1 fastener per 2 square feet). if the top layer is 2'thick or E thicker,install 4 fasteners per 4'x 4'or 8 fasteners per 4'x 8'insulation board. Refer to the Mule-Hide Manual . j for proper fastener density and placement. Additional fastening may be required for certain job conditions. In some instances hot steep asphalt or insulation adhesive may be used to attach the Mule-Hide Poly ISO❑Oto approved concrete decks.Only 4'x 4'boards may be used.Contact Mule-Hlde's Technical Department for specific requirements and procedures. PROTECTION&SAFETY Mule-Hide maintains Safety Data Sheets on all of its products. Safety Data Sheets contain health and safety - information for your development of appropriate product handling procedures to protect your employees and customers. Mule-Hide's Safety Data.Sheets should be read and understood by all of your supervisory personnel and employees before using Mule-Hide products in your facilities. ADDITIONAL INFORMATION The information given on this PDS is subject-to change without notice. Always check the Mule-Hide-website of www.mulehide.com for the latest information,changes and updates or contact Mule-Hide Products Company at 800-786-1492. DISCLAIMER The statements provided concerning the material shown are Intended as a guide for material usage and are believed to be true and accurate at the time of printing. No statement made by anyone may supersede this information,except when done In writing by Mule-Hide Products Co.,Inc. Since the manner of use Is beyond our control,Mule-Hide does not authorize anyone to make any warranty of merchantability or fitness for any particular purpose or any other warranty,guarantee or representation,expressed or Implied,concerning this material. Buyer and user accept the product under these conditions and assume the risk of any failure,any Injury person or property Including that of the user),loss or liability resulting from the handling,storage or use of the product whether or not it is handled,stored or used in accordance with the directions or specifications. Mule-Hide must be notified In writing of any claims and be given the Revised:March-2017 PDS 69-6210 Page 3 of 3