Loading...
HomeMy WebLinkAboutProduct Approval (6) 12/10/2019 Florida Building Code Online Business • Professional Regulation a_ f BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications I Contact Us I BCIS Site Map I Links I ,Search on a,--- Product Approval RECEIVED new ;USER:Public User x - r Product Approval Menu>Product or Application Search>_Application List>Application Detail JAN 18 2019 WJ FL# FI.28095-RS Application Type Revision ST. Lucie County,Permitting Code Version 2017 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments ArchivedFILE':` uOPY Product Manufacturer Nan Ya Plastics Corporation USA Address/Phone/Email 8989 North Loop East Houston,TX 77029 (713)674-7822 Ext 105 ajen96@yahoo.com.tw Authorized Signature Luis Lomas r[lomas@lriomaspe.com Technical Representative Ruskin Wu Address/Phone/Email 8989 North Loop East Houston,TX 77029-1217 (713)674-7822 Ext 105 ajen96@yahoo.com.tw Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By. Steven M. Urich,PE Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 09/23/2019 httpsJ/www.floridabuilding.org/pr/pr_app_df.aspx?param=wGEVXQwtDgvGtOxVMIgT%2bAcEX[ApH9nf8OdhkISAIOBR4hfLyxlm7Q%3d%3d 1/2 12110/2019 Florida Building Code Online s Date Validated 09/29/2019 Date Pending FBC Approval Date Approved 10/06/2019 Summary of Products FL# Model, Number or Name Description 28095.1 SLPS PATIO DOOR LITE 6'11"OS LMI SLPS PATIO DOOR LITE 6'11"OS LARGE MISSILE IMPACT HVHZ HVHZ Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL28095 RI C CAC NI013310,02.p!if Approved for use outside HVHZ:Yes FL28095 RI C CAC NI013310.04.pdf Impact Resistant:Yes FL28095 R1 C CAC NI013310.05.p_d Design Pressure: N/A Quality Assurance Contract Expiration Date Other:FOR RATINGS REFER TO APPROVAL DRAWING.GLASS INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE TrsiCalraftfo Instructions FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE FOR FL28095 R1 II 08-03324A.pdf KURARAY INTERLAYERS Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party:Yes Evaluation Reports FL28095 R1 AE 514310A,pdf Created by Independent Third Party:Yes 28095.2 SLPS PATIO DOOR LITE 8'0"OS LMI SLPS PATIO DOOR LITE 8'0"OS LARGE MISSILE IMPACT HVHZ HVHZ Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL28095 R1 C CAC NI013310.03.pdf Approved for use outside HVHZ:Yes FL28095 R1 C CAC NI013310.06.pdf Impact Resistant:Yes FL28095 R1 C CAC NI013310.07.pdf Design Pressure: +50/-50 Quality Assurance Contract Expiration Date' Other:GLASS INTERLAYER COMPLIES WITH THE 07/31/2022 REQUIREMENTS OF THE FLORIDA BUILDING CODE Installation Instructions ACCORDING TO MIAMI-DADE FOR KURARAY INTERLAYERS FL28095 R1 II 08-03323A.Ddf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party:Yes Evaluation Reports FL28095 R1 AE 514309A.pdf Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Qpyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement . Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records-request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850:487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,KS,must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available'to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ' } Gret�It�Cartl Safie - httpsJ/www.floddabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvGtOxVM1gT%2bAcEXIApH9nf8OdhkISAIOBR4hfLyx1m7Q%3d%3d 2/2 NOTICE OF PRODUCT CERTIFICATION CERTIFICATION NO: NI013310.02 Ra DATE: 09/24/2018 1 .� CERTIFICATION PROGRAM: Structural COMPANY: Nan Ya CODE: 661-1 To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertification.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Nan Ya Plastics Corporation USA Series "SLPS" Outswing Glazed 8989 North Loop East, Suite 800 Fiberglass Side-Hinged Patio Door Houston,TX 77029 (w/Sill Riser) Configuration:OXX/O Glazing:IG-1/8"Tempered Glass/1/8"Tempered Glass/0.090"Kuraray PVB Interlayer/1/8"Tempered Glass Frame: W-3720mm(146.44") H-2062mm(81.19") Panel: W-908mm(35.75") H-2062nun(79.25") DLO: W-635mm(25") H-1600mm(63") SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure: ±2873 Pa (60 psf) Water Penetration Resistance Test Pressure:504 Pa(10.5 pst) Large Missile Impact Rated Product Tested By: National Certified Testing Laboratories Report No: NCTL-210-4112-03 Expiration Date: July 31,2022 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes,VA 23072 Tel: (804)684-5124 Fax: (804)684-5122 L. Roberto Lomas P.E. Engineering Evaluation Report 1432 Woodford Rd. Lewisville,NC 27023 Report No.: 514310A 434-688-0609 rllomas@lrlomaspe.com Manufacturer: Nan Ya Plastics Corporation U.S.A. 8989 North Loop East Houston, TX 77029 Product Line: SLPS Patio Door Lite 6'11"Out-Swing Large Missile Impact-HVHZ Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(a).The product listed herein complies with requirements of the current Florida Building Code. Supporting Technical Documentation: 1. Approval document: drawing number 08-03324 Revision A, prepared,signed and sealed by Luis Roberto Lomas P.E. 2. Report No.: NCTL 21011112-03 signed and sealed by Douglas J. McDougall, P.E. National Certified Testing Laboratories, Orlando, FL TAS 202 Design pressure: ±60.Opsf Water penetration resistance: 6.Opsf(with soft pvc frame) 7.5psf(with standard frame) 10.5psf(with standard frame and 1/2"sill riser) TAS 201 &TAS 203 Large Missile Impact, Level D,Wind Zone 4 TAS 201 &TAS 203 Cyclic Pressure loading ±60.0psf design pressure. 3. Report No.: NCTL 21011112-04 Rev.4 signed and sealed by Douglas J. McDougall P.E. National Certified Testing Laboratories, Orlando, FL TAS 202 Design pressure: ±50.Opsf Water penetration resistance 6.Opsf(with soft pvc frame) 7.5psf(with standard frame) 10.5psf(with standard frame and 1/2"sill riser) TAS 201 &TAS 203 Large Missile Impact, Level D,Wind Zone 4 TAS 201 &TAS 203 Cyclic Load Test, ±50.Opsf design pressure 4. Anchor calculations, report number 514310-1A, prepared, signed and sealed by Luis Roberto Lomas P.E. Limitations and Conditions of use: • Maximum design pressure: Refer to approval drawing • Panel size: 35 3/4!'x 791/4" • Approved configurations:X,X/O, O/X,OX,XO, OX/0,XO/O,XX,XX/0, O/XX, OXX,XXO, OXX/O, O/XXO. • Units must be glazed per ASTM E1300-04/09, according to glazing details in approval drawing. • This product is rated to be used in the HVHZ. • This product is impact resistant and does not require impact protection in wind borne debris regions. • Frame material to be Composite. Installation: Units must be installed in accordance with manufacturer's installation instructions and approval document 08-03324 Revision A. cJ R; L // w •.• Certification of Independence ��V, •�C`ENS+'.qip Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the product(s)for which this report is being issued.Also I ' don't have nor will acquire a financial interest in any other entity involved in the approval e ( j process of the listed product(s). �o TATE QF ��� •'tel D''Rt�P:� ���� .;9:S/0, 1 of 1 Luis R. Lomas, P.E. FL No.:62514 09/23/2019 REVISIONS REV DESCRIPTION DATE APPROVED A ADDED COMPONENTS 08/14/19 R.L. NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH 15. FOR ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH REQUIREMENTS OF THE FLORIDA BUILDING CODE, INCLUDING THE HVHZ. TO ACHIEVE A 1 3/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1 1/8" MINIMUM EDGE 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE 16. FOR ANCHORING INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE 17. ALL FASTENERS TO BE CORROSION RESISTANT. ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED 18. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. GROUT FILLED 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED D. METAL STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 6063—T5 .060" THICK MINIMUM COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF 19. APPROVED CONFIGURATIONS: X, X/0, 0/X, OX, X0, OX/0, XO/0, XX, XX/0, 0/XX, OXX, THE ARCHITECT OR ENGINEER OF RECORD. XXO, OXX/O AND 0/XXO, SEE SHEET 3. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS 20.SIDELITES ARE ASSEMBLED TO FRAME WITH #10 X 3" WOOD SCREWS LOCATED 4" FROM PROVIDED. EACH END AND 19 1/8" MAX O.C. THEREAFTER AT JAMBS AND 4" FROM EACH END AND 6. SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE ONE AT MIDSPAN AT HEAD AND SILL. SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: COMPOSITE. 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09, SEE SHEET 16 FOR GLASS DETAILS. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE X10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. SIGNED:09/17/2019 TABLE OF CONTENTS NAN YA 6989TNORTH ICS OLOOPOEASTON U.S.A. 1R`I t0 ��i% SHEET N0. DESCRIPTION HOUSTON, TX 77029 v•��e.EN.sF?�r�� 1 NOTES SLIPS PATIO DOOR LITE 6'11" OUT—SWING * 0„ 81 *= LARGE MISSILE IMPACT — HVHZ 2 ELEVATION _10J= NOTES ­;:103 TAT OF ;•to- 3 APPROVED CONFIGURATIONS �.C' !� Q •js� .. DRAWN: Dwc No. REv i �S.,1OR1� 4 — 5 ANCHORING LAYOUTS A.R. aTE OB—033 A /!ijs/ONA11 �?'� 6 —14 INSTALLATION DETAILS NTS D9/27/1 B 1 OF 17 15 — 16 COMPONENTS AND GLAZING DETAILS L.ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 LUIS R. Lomas P.E. 17 APPROVED PANEL CONFIGURATIONS 434-888-0809 rllomas@Irtomaspo.com FL NO.: 62514 REVISIONS REV DESCRIPTION DATE APPROVED A ADDED COMPONENTS 08/14/19 R.L. 146 7/16" FRAME WIDTH 37 3/8" 109 1/16" SIDELITE -- WIDTH / \ / NOTES: 1. PANEL SIZE:35 3/4"X 79 7/4" 2. D.L.O.:25"X 63" j 81 3/16" / j '\ APPROVED HARDWARE FRAME HEIGHT -s [ P 5 MANUFACTURER MODEL KWIKSET KNOB: SIGNATURE SERIES DEADBOLT: SIGNATURE SERIES(980) \ / SCHLAGE KNOB: FSERIES ���111 DEADBOLT: BSERIES FIXED 40�VE INA C11 VE FIXED JAMYUAN ENTERPRISES MULTI-POINT SS930 j// / CO.,LTC. LOCKING SYSTEM SLPS PATIO DOOR LITE 6'1 1"OUT-SWING EXTERIOR VIEW WITH STANDARD FRAME WITH STANDARD FRAME AND 1/2"SILL RISER WITH SOFT PVC FRAME WITHOUT SILL RISER DESIGN PRESSURE RATING IMPACT RATING DESIGN PRESSURE RATING IMPACT RATING DESIGN PRESSURE RATING IMPACT RATING LARGEANDSMALL LARGE AND SMALL LARGEANDSMALL +50.01-60.OPSF MISSILE IMPACT ±60.OPSF MISSILE IMPACT +40.01-60.OPSF MISSILE IMPACT MISSILE LEVEL D,WIND ZONE 4 AND HVHZ MISSILE LEVEL D,WIND ZONE 4 AND HVHZ MISSILE LEVEL D,WIND ZONE 4 AND HVHZ (4)PANELS SHOWN,UNLIMITED NUMBER OF PANELS IN UNLIMITED SIGNED:09/17/201 J CONFIGURATIONS ARE APPROVED AS LONG AS INDIVIDUAL PANEL NAN YA PLASTICS CORPORATION U.S,A. AREA DOES NOT EXCEED 19.67 FTs 6989 NORTH LOOP EAST �\\ HOUSTON, TX 77029 \J• GENSF SLPS PATIO DOOR LITE 6'11" OUT—SWING � 0„6�261 HARDWARE SCHEDULE LARGE MISSILE IMPACT — HVHZ ao TATE OF A -HANDLE SETS,ATACTIVEPANEL ELEVATION AND GLAZING DETAIL � C. FLUSH BOLT MECHANISM(DB. STAN LESS STEEL FLUSH OE CAST,STEEL,POM)AT PASSIVE PAN ELLT BAR WITH KEEPER AT PASSIVE L DRAWN: DWG N0. REV RI���u.,\�� D. STAINLESS STEEL MULTI-POINT LOCK WITH KEEPERS AT 11 9/18",40 9/16"&69 5/8"FROM FRAME HEAD SCALE DATE OB s0EE324 A �! /ONA;` �\�1 E. TASTRAGAL ATACTIVE AND PASSIVE PANELS NTS 09/27/18 2 OF 17 F. (3)4X4 DOOR HINGE AT STILE OF ACTIVE AND PASSIVE PANEL L.ROBERTO LOMAS P.E. G.ALUNINUMREINFORCENIENT(A)ATASTRAGAL 1432 WOODFORD RD LEWISVILLE,NO 27023 LUIS R. Lomas P.E. H.ALUNINUMMULLIONREINFORCEMENT(B)ATINTEGRALMULLION 434-688-0609 rllomas@lrlomaspo.00m FL No.: 62514 REVISIONS 110 11/16" REV DESCRIPTION DATE APPROVED 109 1/16" —{ 73 5/16" 37 3/8" � 73 5/16"� A ADDED COMPONENTS 08/14/19 R.L. 40 / // 40/ 01 / 81 3/16" / I- 37 3/8"—I FIXED ACTIVE ` ACTIVE ACTIVE 'INACTIVE FIXED ACTIVE INACTIVE DOUBLE W/SIDELITE DOUBLE W/SIDELITE(MULL) DOUBLE 0/' EXTERIOR VIEW EXTERIOR VIEW EXTERIOR VIEW 11D 11/16" 74 3/4" 81 3/16' 73 5/16" f 37 3/8" 73 5/16" 37 3/8"----37 3/8"d / 0/ / / / ACTIVE' SINGLE 81 3/16" EXTERIOR VIEW 0101 FIXED ACTIVE` FIXED FIXED ACTIVE_N. ACTIVE FIXED SINGLE W/SIDELITE(MULL) SINGLE W/SIDELITE SINGLE W/SIDELITE(MULL) EXTERIOR VIEW EXTERIOR VIEW EXTERIOR VIEW SIGNED:09/17/2019 NAN YA 8PLASTICS 989 CORPORATION00EASTU.S.A. \`\��\S� IILIp'%ij HOUSTON, TX 77029 `�V v\GENS9cs?�� SLPS PATIO DOOR LITE 6'11" OUT-SWING * 0;.6/261 *� LARGE MISSILE IMPACT - HVHZ ( * _ NOTE: APPROVED CONFIGURATIONS -� ALL APPROVED CONFIGURATIONS ARE SHOWN AS LEFTO ,TAT - HAND ACTIVE, RIGHT HAND ACTIVE IS ALSO APPROVED. DRAWN: DWG NO. REV o-SF. •'cCORM'..". S+•. . G 08 -0.3324 NTS DATE 09/27/113 S04 A SHEET OF 17 /111 L.ROBERTO LOMAS P.E. LUIS R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 FL No.: 62514 434-688.0609 rllomas@Irlomaspo.wm RMSIONS REV DESCRIPTION DATE APPROVED F36 1/2" 35 7/8" 8" MAX A ADDED COMPONENTS 08/14/19 R.L. 5 ., 4" MAX 4" MAX 3" MAX. 4 4,. MAX 5., MAX 4' 3" MAX~ MAX F + MAX 3" E MAX I � t . I I ,F MAX 3" MAX 3" MAX. t T_ - f -7 19 1/16" 19 1/16" 19 1/16" MAX MAX MAX O.C. O.C. O.C. 3' MAX MAX 4" MAX' 4„ MAX 3„ MAX MAX MAX MAX. 8° MAX SIGNED:09/17/2019 ANCHORING LAYOUT NAN YA PLASTICS CORPORATION U.S.A. \�����►111lrrii�i. 8989 NORTH TX � ST 7029VJ\y,r EN�y SLPS PATIO DOOR LITE OUT—SWING *_ LARGE MISSILE IMPACT — HVHZ I ANCHORING LAYOUT TAT OF DRAWN: DWG N0. REV -��0��•'cCORl9P�'\� 08 —03324 NTS DATE 09/27/18 snGEET44 A OF 17 L.ROBERTOLOMASP.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 FL No,: 62514 434-688.0609 dlomas@Irlomaspe.com REVISIONS 36 1/2" 35 7/8" 36 1/2" B" REV DESCRIPTION DATE APPROVED I 5" ¢".-_I .-} 4' ¢"�-I 4 5.. IS..— . t ¢ �I .-} ¢" I ¢" 3"I If 5' A ADDED COMPONENTS 08/14/19 R.L. 3" I I I 4" — t r I II 19 1/16" 19 1/16" 3 J 1 9 1/16 19 1/16" MAX, O.C. MAX. O.C. MAX MAX O.C. MAX O.C. "T19 {5" 5- T­ 19 1/16" MAX. O.C. 1_ 3" 3 I 5--1I4" �TI 4"—I —I I— '. 5.. 4 I— ., _ � 5I�I 4"� 4" 89 3" L 5" ANCHORING LAYOUT FOR OXO,XXO AND OXX ANCHORING LAYOUT FOR OXO,XXO AND OXX(MULL) 36 /2" 4" 8" 3" 3" MAX. �— 5" 33" 3" T -F— 3" MAX JT_ 5" 5" 19 1/16" 19 1/16" 19 1/16" 19 1/16" MAX. O.C. MAX. O.C. MAX O.C. MAX. O.C. ANCHORING LAYOUT FOR X SIGNED:09/17/2019 NAN YA PLASTICS CORPORATION U.S.A. 8989 NORTH LOOP EAST HOUSTON, TX 77024 =�vJry\G:EN�pq�l� SLPS PATIO DOOR LITE 6'11" OUT-SWING =*•' 0 61 LARGE MISSILE IMPACT - HVHZ o L J ANCHORING LAYOUTS TAT _OF .; 3' — — r 3" � DRAWN: DWG N0. REV 5'.—{ 4— �4" AL I I 5"�1 I- 4"{-I + f -I 5" A.R. OB-03324 A // S —4" `5" -il 8" — 3 SCALE NTS DATE 09/27/113 SHEETS OF 17 �'OI — IIII111�Y ANCHORING LAYOUT FOR XX,OX AND XO ANCHORING LAYOUT FOR OX AND XO(MULL) L.ROBERTO LOMASP.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 FL No.: 62514 434-688-0609 '110.3901 tomaspe.com REVISIONS 1/2" MIN. REv DESCRIPTION DATE APPROVED WOOD FRAMING EDGE DISTANCE OR 2X BUCK A ADDED COMPONENTS 08/14/19 R.L. BY OTHERS 1 1/4" MIN. EMBEDMENT BACKER ROD 1/4" MAX. 1 1/4" MIN. 1/4" MAX. & APPROVED EMBEDMENT SHIM SPACE SEALANT SHIM SPACE #10 WOOD SCREW WOOD FRAMING OR 2X BUCK BY OTHERS #10 WOOD SCREW HINGE SCREWS, SEE INTERIOR HINGE DETAIL, SHEET 12 rw 1/2" MIN. EDGE DISTANCE T-- EXTERIOR EXTERIOR INTERIOR BACKER ROD DOOR INSTALLATION DETAIL & APPROVED 2X BUCKANOOD FRAMING INSTALLATION SEALANT STANDARD FRAME SHOWN,SOFT PVC FRAME SIMILAR #10 WOOD SCREW NOTES: 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. SILL TO BE SET 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE IN A BED OF DESIGNED IN ACCORDANCE WITH ASTM E2112 APPROVED SEALANT SIGNED:09/17/2019 NAN YA PLASTICS CORPORATION U.S.A. WOOD FRAMING 1 8989 NORTH LOOP EAST ��J\S R L 0 ,9!i�� OR 2X BUCK 1 1/4" MIN HOUSTON, TX 77029 BY OTHERS EMBEDMENT SLIPS PATIO DOOR LITE 6'11" OUT-SWING �* 0 61 >t LARGE MISSILE IMPACT - HVHZ '' DOOR INSTALLATION DETAILS TE OF EDGE DIS MI NCE DRAWN: DWG NO. REV /o, �s FCoR,vP DOOR INSTALLATION DETAIL SCALE DATE OB s03�324 A AL DOOR NTS 09/27/18 6 OF 17 2X BUCIVWOOD FRAMING INSTALLATION STANDARD FRAME SHOWN,SOFT PVC FRAME SIMILAR L.ROBERTOLOMASP.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 434-6880609 il/omas@trlomaspo=m FL No.: 62514 REVISIONS 1/2" MIN. REY DESCRIPTION DATE APPROVED METAL EDGE DISTANCE STRUCTURE A I ADDED COMPONENTS 08/14/19 R.L. BY OTHERS BACKER ROD J 1/4" MAX. & APPROVED MAX. SHIM SPACE SEALANT SHIMHIM SPACE #10 SMS OR SELF DRILLING METAL SCREW STRUCTURE BY OTHERS #10 SMS OR SELF DRILLING SCREW INTERIOR HINGE SCREWS, SEE HINGE DETAIL, SHEET 12 1/2" MIN. EDGE DISTANCE EXTERIOR INTERIOR T__ EXTERIOR BACKER ROD DOOR INSTALLATION DETAIL & APPROVED METAL STRUCTURE INSTALLATION SEALANT STANDARD FRAME SHOWN,SOFT PVC FRAME SIMILAR #10 SMS OR SELF DRILLING SCREW NOTES: 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. SILL TO BE SET 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE IN A BED OF DESIGNED INACCORDANCE WITHASTM E2112 APPROVED SEALANT SIGNED:09/17/2019 uj/' NAN YA 89 STICS LOOPEAST OO ON U.S.A.METAL STRUCTURE HOUSTON, TX 77029 �NS�9s�� BY OTHERS SLPS PATIO DOOR LITE 6OUT—SWING AT SOF •'�� LARGE MISSILE IMPACT CT — HVHZ DOOR INSTALLATION DETAILS 1/2` MIN DRAWN: DWG N0. REV O'cA�l�� P• � EDGE DISTANCE C2'�� DOOR INSTALLATION DETAIL SCALE NTS DATE 09/27/1 B 08-03324seEr7OF 17 A �sj�NA11�"P I METAL STRUCTURE INSTALLATION STANDARD FRAME SHOWN,SOFT PVC FRAME SIMILAR L.ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 LUIS R. Lomas P.E. 434688-0609 rllomas@trfomaspe.00m FL NO.: 62514 1.1/8" MIN. REVISIONS EDGE DISTANCE REV DESCRIPTION DATE APPROVED CONCRETE/ BY ADDED COMPONENTS 08/14/19 R.L. MASONRY ° ° BY OTHERS ° ° t4. EMBEDMENT 1 3/4" MIN. 1/4 1 3/4 MIN. " MAX. °. " ° 1 EMBEDMENT SHIM SPACE OPTIONAL 1X BUCK 1/4" MAX. c SEE NOTES 3-7 SHEET 1 SHIM SPACE �• CONCRETE/ BACKER ROD MASONRY & APPROVED BY OTHERS ° SEALANT 3/16" TAPCON 3/16" TAPCON c .°. INTERIOR HINGE SCREWS, SEE HINGE DETAIL, SHEET 12 Mill I 1 1/13" • °. MIN. a EDGE EXTERIOR •- DISTANCE ' a BACKER ROD & APPROVED SEALANT EXTERIOR INTERIOR OPTIONAL 1X BUCK SEE NOTES 3-7 SHEET 1 DOOR INSTALLATION DETAIL CONCRETE/MASONRY INSTALLATION 3/16" TAPCON STANDARD FRAME SHOWN,SOFT PVC FRAME SIMILAR NOTES: 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, SILL TO BE SET NOT SHOWN FOR CLARITY. IN A BED O F 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE APPROVED SEALANT DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED:09/17/2019 OPTIONAL 1X BUCK SEE NOTES 3-7 NAN YA PLASTICS CORPORATION U.S.A. \���1i11IIrIIi�. SHEET 1 13969 NORTH LOOP EAST `����5 HOUSTON, TX 77029 CONCRETE/ ° SLIPS PATIO DOOR LITE 6'11" OUT–SWING * 81y MASONRY LARGE MISSILE IMPACT – HVHZ — BY OTHERS °v ° 1 3/4" MIN DOOR INSTALLATION DETAILS TAT OF w„ "o e ° e" • EM13EDMENT DRAWN: DWG NO. REQ' ri/A� •FtOR��P, :`�` 1 1/8" MIN ° SCALE DATE 08-03324 A /fi�sSi NA'1E�G� `�: EDGE DISTANCE DOOR INSTALLATION DETAIL NTS 09/27/113 8 of 17 CONCRETE/MASONRY INSTALLATION L.ROBERTO LOMAS P.E. STANDARD FRAME SHOWN,SOFT PVC FRAME SIMILAR 1432 WOODFORD RD LEWISVILLE,NC 27023 Luis R. Lomas P.E. 434-888-0809 rllomas@Irlomaspe.wm FL No.: 62514 1/2" MIN. I REVISIONS EDGE DISTANCE REV DESCRIPTION DATE APPROVED WOOD FRAMING A ADDED COMPONENTS 08/14/19 R.L. OR 2X BUCK BY OTHERS 1 1/4" MIN. EMBEDMENT BACKER ROD �— 1 1/4" MIN. 1/4" MAX. & APPROVED 1/4" MAX. EMBEDMENT SHIM SPACE SEALANT SHIM SPACE I I MIN. #10 WOOD SCREW EDGE INTERIOR #10 X 3" DISTANCE WOOD SCREW #10 X 3" SEE NOTE 20 WOOD SCREW SHEET 1 #10 WOOD SEE NOTE 20 SCREW SHEET 1 WOOD FRAMING OR 2X BUCK BY OTHERS EXTERIOR EXTERIOR INTERIOR BACKER ROD SIDELITE DOOR INSTALLATION DETAIL &'APPROVED SEALANT 2X BUCK/WOOD FRAMING STANDARD FRAME SHOWN,SOFT PVC FRAME SIMILAR #10 WOOD SCREW NOTES: 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE SILL TO BE SET DESIGNED IN ACCORDANCE WITH ASTM E2112 IN A BED OF SIGNED:09/17/2019 APPROVED SEALANT IT NAN YA PLASTICS CORPORATION U.S.A. \\��111'1WI1�)/r 8969 NORTH LOOP EAST LO,� �i HOUSTON, TX 77029 WOOD FRAMING SLPS PATIO DOOR LITE 6'11" OUT—SWINGg�61 Tt_ OR 2X BUCK 1 1/4" MIN BY OTHERS LARGE MISSILE IMPACT — HVHZ ( — EMBEDMENT SIDELITE INSTALLATION DETAILSTATE OF -� 1/2" MIN DRAWN: DWG NO. REV EDGE DISTANCE I SCALE DATE OB SOEE324 A �ij/s�ONAL1E ���� SIDELITE DOOR INSTALLATION DETAIL NTS 09/27/1 B 9 OF 17 2X BUCK/WOOD FRAMING L.ROBERTO LOMAS P.E. STANDARD FRAME SHOWN,SOFTPVCFRAME SIMILAR 1432 WOODFORD RD LEWISVILLE,NC 27023 Luis R. Lomas P.E. 434-688-0809 dlomas@ldamaspe.ccm FL No.: 62514 1/2" MIN. REVISIONS EDGE DISTANCE REV DESCRIPTION DATE APPROVED METAL A ADDED COMPONENTS 08 19 R.L.14 STRUCTURE / / BY OTHERS BACKER ROD J & APPROVED 1/4" MAX. 1/4" MAX. SEALANT SHIM SPACE I F SHIM SPACE #10 SMS OR MIN. SELF DRILLING EDGE F, INTERIOR #10 X 3" SCREW DISTANCE WOOD SCREW TIWO SEE NOTE 20 I #10 X 3" SHEET 1 WOOD SCREW #10 SMS OR SEE NOTE 20 SELF DRILLING SHEET 1 SCREW METAL STRUCTURE EXTERIOR INTERIOR BY OTHERS EXTERIOR BACKER ROD & APPROVED SIDELITE DOOR INSTALLATION DETAIL SEALANT METAL STRUCTURE INSTALLATION STANDARD FRAME SHOWN,SOFT PVC FRAME SIMILAR #10 SMS OR SELF DRILLING NOTES: SCREW 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. SILL TO BE SET 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE IN A BED OF DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED:09/17/2019 APPROVED SEALANT DinNAN YA PLASTICS CORPORATION U.S.A. \\���1►IIIlrlri,, 8989 NORTH LOOP EAST IR. METAL HOUSTON, TX 77029 ��V•v�GEN8Ip:9iP��� STRUCTURE SLIPS PATIO DOOR LITE 6'11" OUT—SWING * 51 *� BY OTHERS LARGE MISSILE IMPACT — HVHZ SIDELITE INSTALLATION DETAILS TATE OF ;•� EDGE DISTANCE DRAWN: DWG NO. REY SIDELITE DOOR INSTALLATION DETAIL SCALE NTS DATE 09/27/18 08-03324SHHET 10 OF 17 A METAL STRUCTURE INSTALLATION L.ROBERTO LOMAS P.E, LUIS R. Lomas P.E. STANDARD FRAME SHOWN,SOFT PVC FRAME SIMILAR 1432 WOODFORD RD LEWISVILLE,NC 27023 434-688•0609 r!lomas@Irlomaspe=c FL No.: 62514 1 1/8" MIN. REVISIONS EDGE DISTANCE r REV DESCRIPTION DATE -PROVED CONCRETE/ MASONRY ° A ADDED COMPONENTS 08/14/19 R.L. BY OTHERS •° ° °° � ° 1 3/4" MIN. a°' °°, " EMBEDMENT 1 3/4" MIN. 1/4' MAX. OPTIONAL 1X BUCK EMBEDMENT SHIM SPACE SEE NOTES 3-7 SHEET 1 9 BACKER ROD 1/4" MAX. 1 1/8" •° SHIM SPACE MIN. e' & APPROVED EDGE SEALANT DISTANCE °a INTERIOR 3/16" TAPCON WO X C WOOD SCREW #10 X 3" v SEE NOTE 20 WOOD SCREW SHEET 1 SEE NOTE 20 3/16" TAPCON SHEET 1 9.v CONCRETE/ a MASONRY a EXTERIOR BY OTHERS o ° BACKER ROD & APPROVED SEALANT EXTERIOR INTERIOR OPTIONAL 1X BUCK SEE NOTES 3-7 SHEET 1 SIDELITE DOOR INSTALLATION DETAIL 3/16" TAPCON CONCRETE/MASONRYINSTALLATION STANDARD FRAME SHOWN,SOFT PVC FRAME SIMILAR NOTES: SILL TO BE SET 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, 'in IN A BED OF NOT SHOWN FOR CLARITY. APPROVED SEALANT 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE OPTIONAL 1X BUCK ❑o DESIGNED IN ACCORDANCE WITH ASTM E2112 SEE NOTES 3-7 SIGNED:09/17/2019 SHEET 1 NAN YA PLASB 89TICS NORTH OLOOPORASTON U.S.A. ````)\S R Glt64;���// -� HOUSTON, TX 77029 Nv ENSFgtp CONCRETE/ Zz MASONRY ° . 1 3/4" MIN SLPS PATIO DOOR LITE 6'11" OUT-SWING 0 51 "kms BY OTHERS .° '•° EMBEDMENT LARGE MISSILE IMPACT - HVHZ �` • ° a SIDELITE INSTALLATION DETAILS TAT OF , EDGE EV / MIN DISTANCE I- A.RDRAWN. DwO No. OB-03324 RA SIDELITE DOOR INSTALLATION DETAIL SCALE NTS JDATE 09/27/18 1 SHEET 11 OF 17 �IN111j.J W' CONCRETEiMASONRYINSTALLATION L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. STANDARD FRAME SHOWN,SOFT PVC FRAME SIMILAR 1432 WOODFORO RD LEWISVILLE,NO 27023 434-6880609 rllomasC7olrlamaspe.com FL No.: 62514 REVISIONS ALTERNATE SILLS REV DESCRIPTION DATE I APPROVED ANCHORS LOCATIONS ANCHOR A ADDED COMPONENTS 08/14/19 R.L. SEE NOTES 14-16 SHEET 1 DLP THRESHOLD & DETAILS SHEETS 6-11 QOSH SILL TO BE SET SUBSTRATE IN A BED OF APPROVED SEALANT BY OTHERS SEE DETAILS SHEETS 6-11 EMBEDMENT DISTANCE SEE NOTES 14-16, SHEET 1 ANCHOR THRESHOLD & DETAILS SHEETS 6-11 SEE NOTES 14-16 SHEET 1 ZOBL4565 & DETAILS SHEETS 6-11 EDGE DISTANCE B SILL BE SET SEE NOTES 14-16, SHEET 1 ANCHOR IN A BED OF & DETAILS SHEETS 6-11 SEE NOTES 14-16 SHEET 1 SUBSTRATE APPROVED SEALANT DLP THRESHOLD QOSH & DETAILS SHEETS 6-11 BY OTHERS MCOLUMBIA SEE DETAILS THRESHOLD 575 SHEETS 6-11 / �' ', �'�',' �',' EMBEDMENT DISTANCE SILL TO BE SET SEE NOTES 14-16, SHEET 1 IN A BED OF DETAILS SHEETS 6-11 SUBSTRATE APPROVED SEALANT EDGE DISTANCEBY OTHERS ` SEE NOTES 14-16 SEE DETAILS SHEET 1 SHEETS 14-16 EMBEDMENT DISTANCE & DETAILS SHEETS 6-11 ,'/� ,',' �',', SEE NOTES 14-16, SHEET ANCHOR �','; �','; '� & DETAILS SHEETS 6-11 ENDURA THRESHOLD ZOBL4565 DLP THRESHOLD SEE NOTES SHEET 1 COS R & DETAILS SHHEETSEFTS 6-11 EDGE DISTANCE SEE NOTES 14-16 SUBSTRATE SILL TO BE SET SHEET 1 S SOTHERS IN A BED OF & DETAILS SHEETS 6-11 BY SEE DETAILS APPROVED SEALANT SHEETS 6-11 IANC { COLUMBIA THRESHOLD 575 EMBEDMENT DISTANCE ��i' SEE NOTES 14-16, SHEET 1 & DETAILS SHEETS 6-11 ANCHOR THRESHOLD SEE NOTES 14-16 SHEET 1 Z064555FN EDGE DISTANCE & DETAILS SHEETS 6-11 SILL TO BE SET SEE NOTES 14-16, SHEET 1 IN A BED OF & DETAILS SHEETS 5-11 APPROVED SEALANT DLP THRESHOLD QOSR SUBSTRATE BY OTHERS SEE DETAILS ,� . , i; ' �';; EMBEDMENT DISTANCE SIGNED:0911712019 SHEETS 14-16 SEE NOTES 14-16, SHEET 1 EDGE DISTANCE ' & DETAILS SHEETS 6-11 NAN YA PLASTICS 8989 NORTH LOOPAST OORON U. S.A. \\\\�\�¢IILIo SEE NOTES 14-16 t— I HOUSTON, TX 77029 v•��CENS 9',�i�G SHEET 1 & DETAILS SHEETS 6-11 SLPS PATIO DOOR LITE 6'11" OUT—SWING * 0,.6281 *_ LARGE MISSILE IMPACT - HVHZ (( kk ENDURA THRESHOLD ZOB4565FN INSTALLATION DETAILS TAT OF DRAWN: DWG NO. REV �•FCORIQP�\'��� 3324 1. OB INTERIOR AND EXTERIOR FINISHES,BY OTHERS, SCALE NTS ATE 09/27/18 snE�12 OF 17 A sI/ 1 NOT SHOWN FOR CLARITY. 1E� 2. PERIMETER AND JOINT SEALATBYOTHERS TOBE L.R013ERTO LOMAS P.E. Luis R. Lomas P.E. DESIGNED IN ACCORDANCE WITH ASTM E2112 1432 WOODFORD RD LEWISVILLE,NO 27023 FL No.: 52514 434-6860609 dlomas@lrlomaspe.com REVISIONS INTERIOR FRAME HEAD REV DESCR PRON DATE APPROVED JAMB PANEL A I ADDED COMPONENTS 08/14/19 R.L_ KEEPER #9 x 7/8" #10 x 1 1/2" SMS SCREW #10 x 3/4" SMS Sx 1 1/2" MS #10 x 1 1/2" SMS #10 X 2" SQUARE #10 x 3/4" SMS DRIVE SCREWS LAYOUTS EXTERIOR SEE ANFORORLOCATYOUTS IIONS HEAD KEEPER DETAIL #1LA 0 X 2" SQUARE FRAME JAMB DRIVE SCREWS SEE ANCHOR LAYOUTS INTERIOR FRAME SILL #9 x 7/8" INTERIOR FOR LOCATIONS SCREW HINGE INSTALLATION DETAIL KEEPER WOOD AND METAL INSTALLATION JAMB EXTERIOR ®� I PANEL3/16" TAPCONS DOOR MULLION DETAIL SIDELITE DOOR ANCHORS SCREWS,NOT SHOWN FOR CLARITY EXTERIOR #10 x 3/4" SMS SMS x 1 1/2" STANDARD FRAME SHOWN,SOFT PVC FRAME SIMILAR SILL KEEPER DETAIL 3/15" TAPCONs #10 x 3/4" SMS PANEL SCREW X 7/8 KEEPER O HINGE INSTALLATION DETAIL MASONRY/CONCRETE INSTALLATION HOOK KEEPER DETAIL FRAME (2) #9 X 7/8" SCREW (2) #9 X 7/8" SCREW p SIGNED:09/17/2079 KEEPER NAN YA PLASTICS CORPORATION U.S.A. BAR PLATE 8 HOUSTON, LOOP `N�vJ;s`GENS9�;%�. DRIVE BAR PLATE DETAIL = `,. F SLPS PATIO DOOR LITE 6'11" OUT—SWING *' a 51 LARGE MISSILE IMPACT — HVHZ _ PANEL INSTALLATION DETAILS �` STATE OF zz DRAWN: DWG ND. REVA. � GRE NTS DATE 09/27/1 B OB-033SEET 13 OF 17 24 A �� S+O.N:A if I11 \�, SLAB MULTI-POINT L.ROBERTO LOMAS P.E. LOCK KEEPER DETAIL 1432WOODFORDROLEWISVILLE,NC27023 Luis R. Lomas P.E. 434-688-0609 tlkmes@Irlomaspe.com FL No.: 62514 REVISIONS REV DESCRIPTION DATE APPROVED A ADDED COMPONENTS 08/14/19 R.L. 1 7 3/4" � 7 3/4" 79 1/4- 39 1/2" 39 1/2- 79 1/4- 71 5/16" 71 5/16" CE 5 1/2" 1 38 3/8" 0/1 35 7/8" LOCKAND HINGES LOCATIONS LOCKAND HINGES LOCATIONS WITH HANDLE WITH LATCH AND DEADBOLT SIGNED:09/17/2019 NAN YA 899NORTH LOO EA PLASTICS OSTON U.S.A. �`\\\�51g Il�fo/�' \ HOUSTON, TX 77029 \�vJ �CENS+ 9pi�-�• SLIPS PATIO DOOR LITE OUT—SWING �1k 51/Y •*� LARGE MISSILE IMPACT — HVHZ INSTALLATION DETAILS DRAWN; DWG N0. REV A.R.E DATE OB 503324 A NTS 09/27/18 14 OF 17 L.ROBERTO LOMAS P.E. LUIS R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NO 27023 FL No.: 62514 434-698-0609 rllomasCo7lrVomaspe.ce REVISIONS REV DESCRIPTION DATE APPROVED 1 11/32" A I ADDEDCOMPONENTS 08/14/19 R.L. 0 1112" —�4 9/16" 4 9/16"�—r O 1 1/4" 3/4` 1 1/4" 2" 1 29/32" a Yl FRAME STANDARD FRAME SOFT PVC REINFORCEMENT(B) FLUSH BOLT MECHANISM COMPOSITE FOAM PVC CO-EX ALUMINUM DIE CAST,STEEL,POM(SS93X BY MICOTA TECH) 1 13/16" 2 1/4" 2 1/16" 6 3/32" 19/32" bQ O L2 7/32" ' DRIVE BAR PLATE r-� STAINLESS STEEL 13/16` �o� 13/16" -� 1 3/B" U QQ 7/16"J + DOOR BOTTOM-B DOOR BOTTOM-A 4"X 4"DOOR HINGE TOP/BOTTOM BAR KEEPER 4 11/32" PVC CO-EX PVC CO-EX STEEL STAINLESS STEEL(SS92H) 1 3/32" O ::)jo 77 5/16- STAINLESS K KEEPER 1 13/16" STEEL(SS92G) 3 1/4" 5 9/16" m } MULTI-POINT LOCKING SYSTEM 2 1/4" STAINLESS STEEL 1 17/32" 0 11 13/16" MULLION COVER(B) SLAB MULTI-POINT FOAM PVC LOCK KEEPER 11/32" STEEL SIGNED:09/17/2019 FLUSHBOLTBAR NAN YA PLASTICS CORPORATION U.S.A. STAINLESS STEEL(SS93B) 8989 NORTH LOOP EAST \\��\\5-R L�'I76'' 5 3/16" HOUSTON, TX 77029 v�CENSFgiP�r'_ 16SLPS PATIO DOOR LITE 6'11" OUT—SWING * 0 5 3/16- 61 / `� LARGE MISSILE IMPACT — HVHZ =;or �� I COMPONENTS ��1 TAT OF 1 7/32- 27/32" n I I�-� DRAWN: DWG NO. REV ` 1 GRE nnTE 08-03324 A SHEET MOLDING COMPOUND SKIN-1 SHEET MOLDING COMPOUND SKIN-2 NTS 09/27/1 B 15 OF 17 FIBERGLASS FIBERGLASS L.ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE,NO 27023 LUIS R. Lomas P.E. 434606-0609 rllomas@lrlomaspe.com FL NO.: 62514 I REVISIONS 2 5/8" REY DESCRIPTION DATE APPROVED —T 1" A ADDED COMPONENTS 08/14/19 R.L. 1/8" TEMP 1 5/8" 1 F6/4- .090" PVB BY KURARAY 1/2" 5/32" TEMP 1^ T 4 9/16" —I 1 3/4" I— 1/8" TEMP— — 1/8" TEMP 1/8" TEMP DOOR SILL COLUMBIA T-ASTRAGAL DECOSEAL SPACEABITE SILICONE .090" PVB BY KURARAY .060-THICKNESS,ALUMINUM 6063-T5(ALTERNATE) BY QUANEBACK BEDDING 1/8° TEMP 1/8" TEMP DOW CORNING 995 EXTERIOR 4 9/16" SHEET MOLDING DESICCANT FILLED 1 17/32" 1/2COMPOUND STAINLESS STEEL SILICONE SKIN-2 SPACER SYSTEMBACK BEDDING —'tBY CARDINAL DOW CORNING 995 INTERIO1 15/32" 1 13/32" SHEET MOLDIN1 SHEET MOLDING COMPOUND MATTE GLASS EXTERIOR 1/2" BITE COMPOUND SKIN-1 SKIN-2 ENDURA THRESHOLD ZOB4565FNGLAZING DETAIL T-ASTRAGAL INTERIOR ALTERNATE RIGID PVC1" SHEET MOLDING COMPOUND DIRECT GLASS DETAIL 4 9/16" 1/8" TEMP SKIN-1 1 3/4- .090" PVB BY KURARAY 1/8" TEMP 1/B" TEMP 1/8" TEMP ALUMINUM INTERIOR 1 15/32" SPACER SYSTEM BY .090" PVB BY KURARAY QINHUANGDAO HIGH—TECH SILICONE 1/8" TEMP — — 1/8" TEMP 2 21/32" DENER ENERGY—SAVING BACK BEDDING ENDURA THRESHOLD ZOBL4565 DOW CORNING 995 INTERIOR ALTERNATE EXTERIOR - I SHEET MOLDING 1/2" BITE COMPOUND DESICCANT FILLEDGLAZING BEAD 4 9/16" SKIN-2 STAINLESSPACERSSYSTEM ENDURA ULTIMATE PUSH BUTTON BY CARDINALSTEEL SILICONE ASTRAGAL SHEET MOLDING DOW KC DDING NG 995 I ALTERNATE COMPOUNDI MINI-BLIND EXTERIOR 1 1/4" RN 1 3/4" GLAZING DETAIL BEA I OPEN GLAZING D DETAIL DLP THRESHOLD QOSR 1 3/4" ALTERNATE SIGNED:09/17/2019 NAN YA PLASTICS CORPORATION U.S.A.IT \\��i�tlrlr/)/// 4 9/16" 2 15/16" 4 11/16" 89HOUSTON, TX 89 NORTH 077 29ST �\\J\5 GENO q'��i I I SLIPS PATIO DOOR LITE 6'11" OUT–SWING =* 1 1/4" 3/4" 1" LARGE MISSILE IMPACT – HVHZ � � COMPONENTS AND GLAZING DETAILS �?s.• TATE OF _ •� 1 I I DRAWN: DWG N0. REV %���•'�CORIOQ:•\�\\ DLP THREALTSHOLD QOSH DLPASTRAGAL COLUMBIA 575 R08-0332LTE GE E SHEET 09/ /1 OF 17 A ,,l7SS/ NAj1G\�\ L.ROBERTO LOMAS P.E. LUIS R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NO 27023 FL Na: 62514 434-688.0609 rllomasCdlrlomaspe.com REVISIONS REV DESCRIPTION DATE APPROVED A ADDED COMPONENTS 08/14/19 R.L. APPROVED PANEL CONFIGURATIONS DIRECT GLAZING OPEN GLAZING BEAD 0 W/STD GLASS W/MATTE GLASS W/MINI-BLIND W/STD GLASS W/MATTE GLASS W/MINI-BUND SIGNED:09/17/2019 NAN YA PLAS8989TICS NORTH OLOOPORASON USAS t�►tllLr� l�/,', HOUSTON, TX 77029 `v y�CENs :9s•�' SLPS PATIO DOOR LITE ACT O � A0,44619 * LARGE MISSILE IMPACT — APPROVED PANEL CONFIGURA ��so TAT OF DD AA.RWN: DWG NO. OB-03324A j��Ss+ GRID SCALE NTS DATE 09/27/18 SHEET IA11�`���. L.ROBERTOLOMASP.E. L111s R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NO 27023 FL No.: 62514 434-688-0609 rllamas@14—aspa.cam