Loading...
HomeMy WebLinkAboutNotice of Acceptance 9 M IAM I•DADE MIAMI-DADE COUNTY ! PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DMSION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE OA RECEIVED miamidade. .vkco.om PGT Industries,Inc. 1070 Technology Drive JAN 4 n0^9 North Venice,FL 34275 SCOPE: ST. Lucie County, Permitting This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami-Dade County) and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami—Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone.- DESCRIPTION: Series"SH7700A"Aluminum Single Hung Window—L.M.I. APPROVAL DOCUMENT: Drawing No. 7700NOA-1, titled "Aluminum Single Hung Install (LM)", sheets 1 through 11 of 11, dated 04/01/18, prepared by-manufacturer, signed and sealed by Anthony Lynn Miller, P.E., bearing the Miami-Dade County Product Control Approval stamp with the Notice of Acceptance number and approval date by the Miami-Dade County Product Control Section. NUSSILE IMPACT RATING:Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, Y...,y model/series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building codenegatively affecting the performance of this product. TERMINATION of this.NOA will occur after the expiration date or if there has been a revision or change s1- in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. �. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of this page 1 and evidence pages E-1 and E-2,as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez,P.E. NOA No. 18-0430.06 QMIAMI•naDe couNr�r Expiration Date: August 23,2023 Approval Date: August 23,2018 Page 1 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS ' 1. Manufacturer's die drawings and sections. 2. Drawing No. 7700NOA-1, titled "Aluminum Single Hung Install (LM), sheets 1 through 11 of 11, dated 04/01/18, prepared by manufacturer, signed and sealed by Anthony Lynn Miller,P.E. B. TESTS - 1. Test reports on: 1) Air Infiltration Test,per FBC, TAS 202-94 2)Uniform Static Air Pressure Test, Loading per FBC,TAS 202-94 3) Water Resistance Test,per FBC,TAS 202-94 4)Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6)Forced Entry Test,per FBC 2411.3.2.1, and TAS 202-94 along with marked-up drawings and installation diagram of an aluminum single hung window,prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-18-7835.1,dated 04/03/18, signed and sealed by Idalmis Ortega,P.E. 2. Test reports on: 1)Air Infiltration Test,per FBC, TAS 202-94 2)Uniform Static Air Pressure Test,Loading per FBC, TAS 202-94 3) Water Resistance Test,per FBC, TAS 202-94 4) Large Missile Impact Test per FBC,TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6)Forced Entry Test,per FBC 2411.3.2.1, and TAS 202-94 window,prepared by Fenestration Testing Laboratory, Inc.,Test Reports No. FTL-18-7835.2,dated 05/04/18, signed and sealed by Idalmis Ortega, P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 61h Edition (2017), dated 04/23/18,prepared by manufacturer, signed and sealed by Anthony Lynn Miller,P.E. 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (R.ER). Manuel pCre—zTr.E. Product ContrExa iner NOA No. -0 30.06 Expiration Date: August 23,2023 Approval Date: August 23,2018 E-1 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-1114.14 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 01/18/18, expiring on 07/08/19. 2. Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers" dated 12/28/17, expiring on 07/04/23. F. STATEMENTS 1. Statement letter of conformance to FBC 6th Edition (2017), dated April 24, 2018, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Statement letter of no financial interest, dated April 24, 2018, issued by manufacturer, signed and sealed by Anthony Lynn Miller,P.E. 3. Proposal No. 18-0005R issued by the Product Control Section, dated 01/16/18, signed by Manuel Perez, P.E G. OTHERS 1. None. Manuel'Per .E. Product Control E a ner NOA No. 18- 30.06 Expiration Date: August 23,2023 Approval Date: August 23,2018 E-2 SERIES SH7700A IMPACT RESISTANT SINGLE HUNG WINDOW �17-13/16"MAX.O,C� DESIGN PRESSURE RATING IMPACT RATING 1)THIS PRODUCT HAS BEEN DESIGNED&TESTED TO COMPLY WITH THE REQUIREMENTS OF 18.3/8"MAX VARIES PER GLASS TYPE, LARGE&SMALL MISSILE THE FLORIDA BUILDING CODE, INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ). \ SEE SHEETS 2.5 IMPACT RESISTANT 2)SHUTTERS ARE NOT REQUIRED WHEN USED IN WIND-BORNE DEBRIS REGIONS.FOR /\_ INSULATED GLASS INSTALLATIONS ABOVE 30'IN THE HVHZ,THE OUTBOARD LITE(CAP) / /J MUST BE TEMPERED,USE ONLY GLASS TYPES 3,7,12,13 OR 15. 17-314"MAX. 17-3/4" 52-1/8"MAX.BUCK WIDTH 3)FOR MASONRY APPLICATIONS IN MIAMI•DADE COUNTY,USE ONLY MIAMI-DADE COUNTY (17-1/4"BUCK) MAXMAX.9-1/2"MAX.• _ 4-11/16"MAX APPROVED MASONRY ANCHORS.MATERIALS USED FOR ANCHOR EVALUATIONS WERE (9"MAX.BUCK) 5"MAX.O.C. na 1 pug fhb SOUTHERN PINE,ASTM C90 CONCRETE MASONRY UNITS AND CONCRETE WITH MIN.KSI B.SEE O,C. D,SEE 4pPmeed P YI nG SHEETS 8&9 SHEET IO ROO R)AdinBCa PER ANCHOR TYPE. _ _ 0.k A.SEE C.SEE VOA# 4)ALL WOOD BUCKS LESS THAN 1-112"THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. SHEETS 8&9 SHEET 10 Nlaml 0Wc Prudue Centrol� 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE.WOOD I I BUCKS DEPICTED AS 2X ARE 1-112"THICK OR GREATER.1X AND 2X BUCKS(WHEN USED) EQUALLY Z_ SHALL BE DESIGNED AND SECURED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. SPACED ANCHORS T WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER,(EOR) TABPER I I } OR ARCHITECT OF RECORD,(AOR). LES6&7&7 / 17-3/16"MAX.O.C. / p1 I O 83 5)ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR ' MAX. 2 STUCCO.USE ANCHORS OF SUFFICIENT LENGTH TO ACHIEVE REQUIRED MIN.EMBEDMENT. ' 12.7/16"MAX.O.C. Tp lM. INSTALLATION ANCHORS SHOULD BE SEALED.OVERALL SEALING&FLASHING STRATEGY X FOR WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND IS BEYOND I Q TIP X 4 HEIGHT THE SCOPE OF THESE INSTRUCTIONS, EQUALLY SPACED I / HEIGHT -_- ANCHORS PER i I 13-5116"MAX.O.C. 6)114'MAX.SHIMS ARE REQUIRED AT EACH ANCHOR LOCATION WHERE THE PRODUCT IS TABLES e&7 00 NOT FLUSH TO THE SUBSTRATE.USE SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. _ 5"MAX. W 9-12"MAX. O.C. I / C w o 77 7)DESIGN PRESSURES: (9"MAX.BUCK) V'' O co A.NEGATIVE DESIGN LOADS BASED ON STRUCTURAL&CYCLE TESTING AND GLASS PER LO w O ASTM E1300. 1 G N z y a1oD O� O B.POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE,STRUCTURAL&CYCLE NO ANCHORS AT SILL i'7 D 7 O w (/) TESTING AND GLASS PER ASTM El300. I B \I \ "J J o a ui _ Z o C.DESIGN LOADS ARE BASED ON ALLOWABLE STRESS DESIGN,ASD. �1 53-118°MAX.TIP TO TIP WIDTH 11���1"WEEP NOTCH 4-11/16"MAX. �I���C.1"WEEP NOTCH O LL O W o AT EACH END AT EACH END Z U) c n 8)THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WINDLOADS ELEVATION FOR TYP.FLANGE FRAME ELEVATION FOR TYP.FIN FRAME SHOWN WITH U U X80 CORRESPONDING TO THE REQUIRED DESIGN PRESSURE.THE 33-1/3%STRESS INCREASE F-- o J 'oN HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT.THE 1.6 LOAD DURATION FACTOR SHOWN WITH EQUAL-LITE CONFIGURATION EQUAL-LITE CONFIGURATION I-w �' S¢ ¢ DMO WAS USED FOR THE EVALUATION OF ANCHORS INTO WOOD.ANCHORS THAT COME INTO y U) O CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEETTHE REQUIREMENTS OF THE TABLE 1:ALLOWABLE GLASS TYPES Z m Z F-• FLORIDA BUILDING CODE FOR CORROSION RESISTANCE. USER INSTRUCTIONS: 9)METAL SUBSTRATE TO MEET MIN.STRENGTH AND THICKNESS REQUIREMENTS PER Glass Type Description(Listed from Exterior to Interior) DP O W c- Table# 1)DETERMINE THE SITE SPECIFIC,WINDOW OPENING'S DESIGN j J LL p CURRENT FLORIDA BUILDING CODE AND TO BE REVIEWED BY THE AUTHORITY HAVING 1 1/8"AN,.090"PVB,118"AN 2 PRESSURE REQUIREMENT FROM ASCE 7. m = W JURISDICTION. 2 13/16"LIG:118"AN CAP,AIRSPACE,1/8"AN,.090"PVB,1/8"AN 2 ® W c5 2)KNOWING YOUR GLAZING OPTION(TABLE 1),WINDOW J 10)REFERENCES:TEST REPORTS FTL 18-7835.1&18-7835.2;ELCO ULTRACON NOA;ELCO 3 13116"LIG:1/8"TP CAP,AIRSPACE,118"AN,.090"PVB,1/8"AN 3 CONFIGURATION AND SIZE,DETERMINE YOUR WINDOWS DESIGN ZFW- 1aayS CRETEFLEX NOA;NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, 4 118"HS,.090"PVB,1/8"HS 4 PRESSURE FROM TABLES 2-5.IT MUST EQUAL OR EXCEED THE _ _ ANSUAF&PA NDS&ALUMINUM DESIGN MANUAL DESIGN PRESSURE REQUIREMENT FOR THE WINDOW OPENING j rA O 5 3/16"AN,.090"PVB,3116"AN 4 a Z OBTAINED IN STEP 1. u_ � J 11)APPLICABLE EGRESS REQUIREMENTS TO BE REVIEWED BY BUILDING OFFICIAL. 6 13/16"LIG:3116"AN CAP,AIRSPACE,1/8"AN,.090"PVB,1/8"AN 4 O 7 Qo 7 13116"LIG:3/16"TP CAP,AIRSPACE,1/8"AN,.090"PVB,1/8"AN 4 3)DETERMINE THE ANCHOR QUANTITY FROM TABLES 6&7. Z W C) 3/16"AN 5 w 090"SG, Z) W 2 / FIGURE A:ALLOWABLE SASH CONFIGURATIONS AND SHAPES 8 3116"AN,. 4)INSTALL AS PER SHEET 7 FOR FLANGE INSTALLATION,SHEET 8 O �{ WIDTH WIDTH WIDTH 9 3116"HS,.090"SG,3/16"HS 5 FOR EQUAL LEG INSTALLATION OR SHEET 9 FOR INTEGRAL FIN Q (7 10 13/16"LIG:1/8"AN CAP,AIRSPACE,1/8"HS,.090"SG,1/8"HS 5 INSTALLATION. - •�sa0 1sauag TT I I T 11 13/16"LIG:118"AN CAP,AIRSPACE,3116"AN,.090"SG,3/16"AN 5 NOTE:DESIGN PRESSURE RATING DETERMINATION IS THE SAME %J0111111", Tr 12 13116"LIG:118"TP CAP,AIRSPACE,1/8"HS,.090"SG,VW HS 5 PROCESS FOR ALL FRAME TYPES(FLANGE,INTEGRAL FIN OR ��%%p1Y LYNN 1- 1- _ _ // 13 13116"LIG:118"TP CAP,AIRSPACE,3116"AN,.090"SG,3116"AN 5 EQUAL LEG/BOX). ����0,......,,• O O / 14 13/16"LIG:3/16"AN CAP,AIRSPACE, 1/8"HS,.090"SG,1/8"HS 5 `�"t OCENSF'•.C� _ _ = 15 13/16"LIG:3/16"TP CAP,AIRSPACE, 1/8"HS,.090"SG,1/8"HS 5 �'• NO.58705 SG=KURARAY SENTRYGLAS®INTERLAYER BY GENERAL NOTES.................................................1 1 KURARAY AMERICA,INC. ELEVATIONS.........................................................1 YL a CODEB l STANDARDS USED: ® RECTANGULAR RADIUS-TOP RECTANGULAR PVB=KURARAY TROSIFOL PVB INTERLAYER BY DESIGN PRESSURES I GLAZING DETAILS........2-4 [1/ WITH EQUAL WITH PROVIEW WITH CUSTOM •2017 FLORIDA BUILDING CODE(FBC),6TH EDITION KURARAY AMERICA,INC. ANCHOR QUANTITIES..........................................5-6 i0,(%•'• ST TE OF !v. LITE SASH SASH SASH •ASTM E1300.09 AN=ANNEALED INSTALLATION,FLANGE......................................7 ; "40RIO);.•' •ANSI/AF&PA NDS-2015 FOR WOOD CONSTRUCTION �i S G' HS=HEAT-STRENGTHENED INSTALLATION,EQUAL LEG.................................8 �7 S� •••• MALL AY HADES BY ALL SAH THE SHAPE IN A BTIONS LOCK AND OBTAINING RE ED.SHAPES -ALUMINUM DESIGN MANUAL,ADM-2015 TP=TEMPERED INSTALLATION,INTEGRAL FIN............................9 'SII 0NAL 11%1%� AISI S100-12 EXTRUSION PROFILES.........................................10 DESIGN PRESSURES AND ANCHORAGE FOR THAT BLOCK SIZE FROM THE •AISC 360-10 ASSEMBLY&PARTS LIST....................................11 A.LYNN MILLER,P.E. TABLES ON THE FOLLOWING SHEETS. P.E.058705 r TABLE 2: Batom sash Sash Height Design Pressure(lbslf?)for Glass Types 1&2 Description Range(n) Tip to Tp Width for Given Range 16" 1 25" 33" 1 37' 41' 1 46" 49' 53.118" ZV Equal-lite 12.464 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 $0.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 $0.0 Equal4"' 75.964 +65.0 -80.0 +65.0 -80.0 +65.0 $0.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 5/16"NOM. 31" Standard Prode�v 12.994-15.953 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 GLASS STACK Shortest 12.464-12.993 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -60.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1/8"AN GLASS Lpyrffw sic-rd3inawuh It Equal-lite 19.652 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 .090"PVB FL-6f. {ding c' - Standard Pro leo 15.944-19.651 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65,0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -90.0 118"AN GLASS I. 38-318" Custom Size 15.131-15,943 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 •80.0 +65.0 -80.0 +65,0 .80.0 +65.0 -80.0 30 'N')AN Custom Size 14.131-15.130 +65.0 -80.0 +65.0 -00.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 •80.0 X91:m!D .P:Mnc1 oaeror Shortest 12464-14.130 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 26 • 1/2"NOM. - Equal4ite 22964 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 430.0 +65.0 430.0 GLASS BITE Custom Size 20.131-22.963 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65,0 430.0 EXTERIOR Standard Prouew 18.594-20.130 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 •80.0 45' Custom Size 16.131-18.593 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 75 Custom Size 15.131-16.130 +65.0 -80.0 +65.0 -80.0 +65.0 -60.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Custom Size 14.131-15.130 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65,0 -80.0 +65.0 -80.0 +65.0 -80.0 +85.0 .80.0 +65.0 -80.0 34 Shortest 12.464-14.130 +65.0 -80.0 +65.0 •80.0 -65.0 -80.0 +65.0 -60.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 GLASS TYPE 1 Equal-lite 24.964 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -800 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Custom Size 22131-24.963 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 - Standard ProAaw 20.194-22.130 +65.0 -80.0 1+65.0 -8D.0 +65.0 1 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65,0 40.0 +65.0 430.0 i m N 49" Custom Size 18.131-20.193 +65.0 -80.0. +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80,0 w9 � Custom Size 16.131-18.130 +65.0 -80.0 +65.0 -B0.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Of Custom Size 14.131-16.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -77.6 to P.. O O Shortest 12464-14.130 +65.0 -80.0 +65.0 -BD.O +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -75.1 �I 13116"NOM. f- i w aieG 0 Equal4ile 25.777 +65.0 -80.0 +65.0 •80.0 +65.0 -80.0 +65.0 -80.0 +65.0 $0.0 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 I GLASS STACK Q tq. w (n Z Custom Size 24.131-25.776 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 .090"PVB J J o a rrroi _ Z o o Standard ProAew 20.844-24.130 +65.0 -80.0 *65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1+65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 AIRSPACE Z- 0 o Custom Size 20.131-20.843 *65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1/8"AN GLASS =lL T A6 r lo 50.5!8" 1/8"AN GLASS U U O Custom Size 18.131-20.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 480.0 +65.0 -80.0 +65.0 -80.0 +65.0 •80.0 N Custom Size 16.131-18.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -77.6 31 75 H W ¢ Q 9MG Custom Size 14.131-16.130 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -80.0 +65.0 -60.0 +65.0 430.0 +65.0 -80.0 +65.0 -75.1 /'� } F Shortest 12.464-14.130 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -73.9 @0R 5B 12"NOM. Z v Z Equal-lite 31.964 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 EXTERIOR GLASS BRE Custom Size 28.131•31.963 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -77.6 Z LL Standard ProAew 25.794-28.730 +65.0 •80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 •80.0 +65.0 -73.9 0 Custom Size 24.131-25.793 +65.0 -80.0 +65.0 -60.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -727 rn = N 63" Custom Size 22.131-24.130 +65.0 -80.0 +65,0 -80.0 +65.0 •80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -78.8 +65.0 -70.5 35 R SB 70-73 ® _ - Custom Size 20.131-22.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -77.1 +65.0 .68.4 laay5 Custom Size 18.131-20.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -75.4 +65.0 -66.5 Z GLASS TYPE 2 � w Custom Size 16.131-18.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 *65.0 -77.1 +65.0 -73.8 +64.7 E1.7 ¢ Shortest 13.194'-16.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -75.9 +65.0 -71.8 +65.0 -68.2 +62.3 -6Z3 p J 0 Equal-lite 38.464 +65,0 -80.0 +65.0 .80.0 +65.0 -81).0 +65.0 •80.0 +65.0 -80.0 +65.0 -80.0 +65.0 •80.0 +65,0 -73.9 H Z m r Custom Size 36.131-38.463 +65.0 -80.0 +65.0 -80.0 +65.0 .8D.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -79.8 +65.0 •71.6 w H ~ Custom Size 34.131-36.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -77.9 +65.0 -69.4 U J D. (!) 76" Standard Pro%i w 30.994-34.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -75.4 +65.0 -66.5 2 Custom Size 30.131-30,993 +65.0 -80.0 +65.0 -8D.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -78.9 +65.0 •74.6 +65.0 -65.6 apt! osaG saua5 Custom Size 28.131-30.130 +65.0 1 .80.0 +65.0 -80.0 +65,0 -8D.0 +65.0 -80.0 +65.0 -79.1 +65.0 -75.3 +65,0 -71.9 +63.8 -63.8 \117 Shortest 26.194•-28.130 +65.0 -80.0 +65.0 -80.0 +65,0 •80.0 +65.0 -80.0 +65.0 .75.9 +65.0 -71.8 +65.0 X8.2 +62.3 -62.3 `\��� GtVLYNNM/I,,� Equal43te 42464 +65.0 -80.0 +65.0 -80.0 +65.0 $0.0 *65.0 -80.0 +65.0 -60.0 +65.0 -80.0 +65.0 -77.9 +65.0 E9.4 `_��.•'V,IGENS,, 84" Custom Size 38.131-42463 +65.0 1 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -60.0 +65.0 -80.0 +65.0 -78.9 +65.0 -74.6 +65.0 -65.6 Standard ProAew 34.194•-38.130 +65.0 1 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 -65.0 -75.9 +65.0 -71.8 +65.0 -68.2 +62.3 -62.3 N0.58705 •MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT•49.391 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-48.391 7:_0 MINIMUM SASH HEIGHT FOR FLANGED,RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-49.806 /f,Q7' MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG,RADIUS TOP WINDOWS IS:BUCK HEIGHT-48.806 ;�Q T E F •••((7� 1)TIP TO TIP DIMENSIONS SHOWN.FOR INTEGRAL FIN AND EQUAL-LEG WINDOWS,SUBTRACT 1"FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. 7/'111 NAS %,���� 2)FOR SIZES NOT SHOWN,ROUND UP TO THE NEXT AVAILABLE SIZE. AN=ANNEALED 3)FOR RADIUS TOP WINDOWS,FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. TP=TEMPERED A LYNN MILLER,P.E. 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF-65 PSF.NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. HS=HEAT STRENGTHENED P•E.#58705 TABLE 3: Bottom Sash Sash Height Design Pressure(lbs/f?)for Glass Type 3 Oesodption Range On) Tp to Tip Wdth Por Ghen Range 18" 1 25" 33" 1 37" 41" 45" 49' 53118' 24' Equal-lite 12464 +65.0 -80.0 +65.0 -811.0 +65.0 -80.0 +65.0 +30.0 +65.0 80.0 +65.0 -80.0 +65.0 8GLASS STACK 0.0 +65.0 -80.0 _�I NOM. Equal-lite 15.964 +65.0 -80.0 +65.0 -80.0 +65.0 80.0 +65.0 -80.0 +65.0 80.0 +65.0 -80.0 +65.0 80.0 +65.0 -80.0 GLASS 31" Standard Proview 12.994-15.963 +65.0 -80.0 +65.0 -80.0 +65.0 1-80.0 1+65.0 -60.0 +65.0 80.0 +65.0 -80.0 +65.0 1-80.0 +65.0 -80.0 .090"PVB Shortest 12.464-12.993 +65.0 -80.0 +65.0 -80.0 +65.0 80.0 1+65.0 •80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 AIRSPACE 1l8"TP GLASS 4ppmred as Wmplyiug pith IW Equal-lite 19.652 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -8D.0 +65.0 -60.0 118"AN GLASS Rride Bolding Cad Standard Pmview 15.944-19.651 +65.0 -80.0 +65.0 -BO.0 +65.0 -80.0 +65.0 -80.0 +65.0 430.0 +65.0 -80.0 +65.0 -8D.0 +65.0 80.0 31 75 Oak t O� 383/8" Custom Size 15.131-15.943 +65.0 -80.0 +65.0 •80.0 +65.0 80.0 +65.0 .80.0 +65.0 80.0 +65.0 •80.0 +65.0 -80.0 +65.0 -80.0 /'� .VOA# Cuslom Size 14.131-15.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 p5A1pR 5B a7i�tai Dade Prvduct trot Shortest 12.464-14.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -60.0 +65.0 -80.0 V 12SS Brr Equal-lite 22964 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -8D.0 +65.0 -80.0 EXTERIOR GLASS BITE Custom Size 20.131-22.963 +65.0 .80.0 +65.0 •80.0 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 (� Standard Protiew 18.594-20.130 +65.0 •80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -60.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 •80.0 Vv'' 46' Custom Size 16.131-18.593 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 70-73 Custom Size 15.131-16.130 +65.0 -B9.0 +65.0 -BO.O +65.0 80.0 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65,0 80.0 35 OR 5B Custom Size 14.131-15.130 +65.0 -80.0 +65.0 -80.0 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 •80.0 GLASS TYPE 3 Shortest 12.464-14.130 +65.0 .80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Equal-lite 24.964 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Custom Size 22131-24.963 +65.0 -80.0 +65.0 .80.0 +65.0 80.0 +65.0 -80.0 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Standard Provew 20.194-22.130 +65.0 -00.0 +65.0 -80.0 +65.0 -80.0 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65,0 -80.0 a0 Y 49" Custom Size 18.131-20.193 +65.0 -80.0 +65.0 .80.0 +65.0 •80.0 +65,0 -80.0 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 � z U Custom Size 16.131-18.130 +85.0 -80.0 +65.0 •8D.0 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 w "a8 Custom Size 14.137-16.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 ❑� �o p y jd rtest 12.464.14.130 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 N z a1oO w °i ual-lite 25.777 +65.0 -80.0 -65.0 -60.0 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 U w O = om Size 24.131-25.776 +65.0 -80.0 +65.0 -B0.0 +65.0 80.0 +65.0 -80.0 +65.0 -60.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 "-1 r3 a ori OZ Z rd Prodew 20.844-24.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65,0 -80.0 Z LL N '2 n �8" om Size 20.131-20.843 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 -30.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1 2 L j om Size 18.131-20.130 +65.0 -60.0 +65.0 .80.0 +65.0 .80.0 +65.0 -80.0 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 •80.0 W U 00 ®J J umo�O .oN om Size 16.131-18.730 +65.0 -80.0 +65.0 •80.0 +65.11 80.0 +65.0 -80.0 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 W a Q DMO om Size 14.131-16.130 +65.0 80.0 +65.0 -80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 -80.0 0 F. rtest 12464-14.130 +65.0 811.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 -80.0 +65.0 80.0 +65.0 -80.0 Z 3 Z ual-lite 31.964 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -B0.0 +65.0 80.0 +65.0 .80.0 +65.0 -80.0 +65.0 80.0 U _ om Size 28.131-31.953 +65.0 -80.0 +65.0 -80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 •80.0M+65.O -80.0 0.0 +65.0 -80.0 Z LL rd Proxim 25.794.28.130 +65.0 80.0 +65.0 80.0 +65.0 -80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 80.0 +65.0 80.0U om Size 24.131-25.793 +65.0 80.0 +65.0 -80.0 +65.0 80.0 +65.0 -80.0 +65.0 80.0 +65.0 80.0 80.0 +65.0 80.0 'o a1 63" om Size 72.131-24.130 +65.0 -80.0 +65.0 -80.0 +65.0 80.0 165.0 -80.0 +65.0 80.0 +65.0 -80.0 80.0 +65.0 •80.0 ® fJ1om Size 20.131-22.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 165.0 80.0 +65.0 -80.0 80.0 +65.0 -78.0om Size 18.131-20.130 +65.0 80.0 +65.0 •80.0 +65.0 -80.0 +65.0 80.0 +65.0 80.0 +65.0 ,-80.0 80.0 +65.0 -75.8CustomSize16.131-18.130 +65.0 80.0 +65.0 80.0 +65.0 -80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 80.0 +65.0 -73.8Shortest 73.194'-16.130 +65.0 811.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 BD.O 77.7 +65.0 -71.0 C) J p Equal4ite 38.464 +65.0 •80.0 +65.0 •80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 -80.0 80.0 +65.0 80.0 F: Z m Custom Size 36.131-38.463 +65.0 -80.0 +65.0 •80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 •80.0 +65.0 -80.0 +65.0 -811.6 w < _ Custom Size 34.131-36.130 +65.0 -80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 -80.0 +65.0 •79.1 0 76' Standard Pro�dew 30.994-34.130 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 -80.0 +65.0 80.0 +65.0 -75.8 Q Custom Size 30,131-30.993 +65.0 -80.0 +65.0 -80.0 +65.0 •80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 -74.8 a17t1 sa0 sauas Custom Size 28.131-30.130 +65.0 -80,0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1+65.0 1 80.0 +65.0 -80.0 +65.0 -80,0 +65.0 -72.7 Shortest 26.194•-28.130 +65.0 -80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 -80.0 +65.0 -77.7 +65,0 -71.0 \�.` Y LYNA( Equal-ite 42464 +65.0 -80.0 +65.0 1 80,0 +65.0 80.0 +65.0 80.0 1+65.0 1 80.0 +65.0 -80.0 +65.0 80.0 +65.0 -79.1 •��.•'•`10ENSF S4" Custom Size 38.131-42.463 +65.0 -80.0 +65.0 80.0 +65.0 -80.0 +65.0 80.0 +65.0 80.0 +65.0 -80.0 +65.0 80.0 +65.0 -74.8 `QCT.•• •,(C4��% Standard Prrnlew 34.194•-3B.13D +65.0 -80.0 1+65.0 1-80.0 1+65.0 1-80.0 1+65.0 80.0 +65,0 80.0 1+65.0 -80.0 +65.0 •77.7 1+65.0 1•71.0 No.58705 •MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-49.391 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-48.391 ' MINIMUM SASH HEIGHT FOR FLANGED,RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-49.806 ' I� .;•��` MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG,RADIUS TOP WINDOWS IS:BUCK HEIGHT-48.806 Q�•, ITTF i�s '•:°CORIDP.•.•G���� 1)TIP TO TIP DIMENSIONS SHOWN.FOR INTEGRAL FIN AND EQUAL-LEG WINDOWS,SUBTRACT 1"FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. 7777NAL 2)FOR SIZES NOT SHOWN,ROUNDUP TO THE NEXT AVAILABLE SIZE. AN=ANNEALED 1/1111111111`` 3)FOR RADIUS TOP WINDOWS,FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. TP=TEMPERED A.LYNN MILLER,P.E. 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF+65 PSF.NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. HS=HEAT STRENGTHENED P•E.#58705 TABLE 4: TABLE 5: z5116OM. Desi n Pressure for Glass T es 8.15 Design Pressure(Ibslft)for Glass Types 4-7 5116"NOM.I..r ,090"SG 3116"AN GLASS ,090"SG 3/16"HS GLASS Ti To GLASS STACK Bottom Sash Tp To Tp Bottom Sash P P Sash Heigh Width 3)16"A GLASS 3/1GLASS Sash Height 118'HIS GLASS Description 30 30 Description Ran Widln ,090"PVB Range Pn) Range(in) for Given Range 53-1/e" for GAen Range 50 -B 1!6'H GLASS 26 2e 24' Equal-lite 12484 +65.0 -80.0 30 24' Equal-lite 12464 +80.0 •110.0 12"NOM. 12'NOW. q GLASS BRE GLASS BITE EquaNite 75.964 +65.0 -80.0 26 Equal4ite 75.984 +80.0 -110.0 EXTERIOR EXTERIOR 31° Standard ProVew 72.994-75.983 +fi5.0 40.0 12"NOM. 31" Standard Pmuew 12.994-15.963 +80.0 -110.0 GLASS BITE Shortest 12484-12983 +85.0 -80.0 EXTERIOR Shortest 12.464-12.993 +80.0 -110.0 74 74 tr.0 EquaHile 19.652 +80.0 "110.0 34 34 Lppmed w w�ly+e'wM� Equal-lite 19.652 +65.0 -80.0 74 GLASS TYPE 8 GLASS TYPE 9 LTozl BOLD t Standard Prodew 15.944-19.651 +80.0 -110.0 Standard Pmdew 75.844-19.851 +65.0 40.0 34 Daft 38-3/8" Custom Size 15.131-15.943 +65.0 -80.0 GLASS TYPE 4 383/8" Custom Size 15.131-15.943 +80.0 -110.0 .yppW Custom Size 14.131-16.130 +80.0 •110.0 13/16"NOM. GLAS13116"S NOM. yyl wI DMc Product Cm11rul Custom Size 12.737•15.130 +65.0 -80.0 ��- GLASS STACK �I GLASS STACK Shortest 12.464-74.130 +65.0 40.0 Shortest 12.464-74.130 +BOO -110.0 .090"SG .090"SG GLA NOM. Equal-lite 22964 +BD.0 -110.0 AIRSPACE '" Equal-lite 22984 +85.0 -80.0 GLASS STACK AIRSPACE Custom Size 20.131.22963 +65.0 -80.0 Custom Size 20.131-22.963 +80.0 "110.0 118"AN GLA 1/8"H6 GLASS 118"AN GLASS 3116"AN GLASS 3116"AN GLASS Standard Prodew 18.584-20.130 +80.0 -110.0 3/ 31 Standard Plotiew 18.594-20.130 +65.0 -80.0 .090"PVB 74 74 45" Custom Size 16.131-18.593 +65.0 -80.0 30 3/16�T GLASS 45" Custom Size 16.131-'180593 +80.0 -110.0 �'�,, Custom Size 16.131-16.130 +65.0 30.0 27 lj C.tom Size 15.131-16.130 +80.0 -110.0 '�"R 5 12°NOM. �R 5 12'NOM. Custom Size 14.131-15.130 +65.0 -80.0 1/2"NOM. Custom Size 14.131"15.130 +80.0 -110.0 EXTERIOR GLASS BITE EXTERIOR GLASS BITE Shortest 12.464-14.130 +65.0 -80.0 E%TEmoR GLASS BITE Shortest 12.454-14.130 +80.0 -110.0 �_ Equal-lite 24.964 +65.0 •80.0 Equal-lite 24.964 +80.0 -110.0 70.73 70.73 Custom Size 22.731-24.963 +85.0 -80.0 tq Custom Size 22.131-24.963 +80.0 -110.0 ®5 OR 5 ®OR 5 Standard Pro%iew 20.194-22.130 +80.0 -110.0 GLASS TYPE 10 GLASS TYPE 11 Standard Pralew 20.794-22130 +65.0 30.0 30. OD Y GLASS TYPE 5 49" Custom Size 78.131-20.793 +80.0 -110.0 49" Custom Size 18.131-20.193 +65.0 -80.0 W z � (n Custom Size 16.131-18.130 +60.0 -110.0 3 naa Custom 5¢e 16.131-18.130 +65.0 -80.0 I- 13!16"NOM. GLASS NOM. w -T Custom Size 14.131-16.130 +65.0 .80.0 Custom Size 14.731-76.130 +80.0 -170.0 �"I f'� GLASS STACK f~ GLASS STACK o z 0 US 13!16'NOM. ❑ w a Shortest 12.464-74.130 +80.0 -170.0 .090°SG .090"SG 10 ._ Shortest 12.464-14.130 +65.0 30.0 GLASS STACK P_ AIRSPACE AIRSPACE-­ Equal-lite IRSPACE �'r aloe O Equal-lite 25.777 +80.0 -110.0 (Y •y Equal-lite 25.777 +65.0 30.0 *. . PVB s 1/8"TP GLASS 1/8"TP GLASS U N z y O s Custom Size 24.131-25.778 +85.0 -80.0 AICustom Size 24.131-25.776 +80.0 -110.0 1/8"HS GLASS 3/16"AN GLASS ❑m F CO ZO F 3/16" N GLASS Standard Pro�iew 20.844-24.130 +80.0 -110.0 31 74 31 74 JJ O a w ZStandard Pmdew 20.844"24.130 +65.0 30.0 0 LLpW OCustom Size 20.131-20.843 +85.0 30.0 74 Custom Size 20.131-20.843 +80.0 -110.0 OR 5 5 OR 58 Z 40- ss/a° ® 12"NOM. ® 12'NOM. =R_ 565/g Custom Size 18.137-20.130 +fi5.0 -80.0 Custom Size 18.131-20.130 +80.0 -110.0 GLASS BITE GLASS BITE Wr®5 OROM. Custom Size 18.131-18.130 +80.0 -170.0 EXTERIOR EXTERIOR U(� O ®Custom Size 16.131-18.130 +65.0 30.0 N Z co =< J EX7ERIBITE Custom Size 14.131-16.730 +80.0 -170.0 40 Ohio Custom Size 14.131-16.130 +65030.0 W Shortest 12.464-14.730 +650 300 Y' Shortest 12.464-14.130 +80.0 -110.0 5@OR 5 70-73 ®OR 5 70.73 n0 7a !nEquaNite 31.964 +65.0 30.03 Equal-llle 31.964 +80.0 -110.0 GLASS TYPE 12 GLASS TYPE 13 Z Z Custom Size 28.131-31.983 +65.0 6 OCustom Size 28.131-31.963 +80.0 -1100Ur Standard ProMm 25.794-28.130 +65.0 -80.0 Standard Prodew 25.794-28.130 +80.0 70.0 Z LL Custom Size 24.131-25.783 +65.0 40.0 Custom Size 24.131-25.793 +80.0 -110.0 13116"NOM. I13116"NOM. O 83' Custom Size 22131-24.130 +65.0 -60.0 Imo- 13116"NOM. 63" Custom Size 22.131-24.130 +80.0 -110.0 GLASS STACK I GLASS STACK 2 V --�I .090'SG .090'SG Custom Size 20.131-22.130 +65.0 30.0 I GLASS STACK Custom Size 20.131-22130 +80.0 -110.0 AIRSPACE AIRSPACE ® N J Custom Size 18.131-20.130 +65.0 40.0 AIRSPACE .090"PVB Custom Size 18.131-20.130 +80.0 -t 10.0 3/16"AN GLASS- 1/e°HS GLASS 3116"TP GLASS 1/8'HS GLASS S Z laau5 Custom Size 18.131-18.130 +65.0 40.0 3/1fi°TP GLASS 118"AN GLASS Custom Size 16.131-18.130 «80.0 -710.0 31 74 9l 74 ~ (!7 Shortest 13.194'-16.130 +85.0 40.0 31 74 Shortest 73.794•-18.130 +80.0 -110.0 Q Q Equal-lite 38.464 +65.0 40.0 Equal-lite 38.464 +80.0 -110.0 5®OR 58 12°NOM. ®OR 5 12'NOM. ❑ J 00 Custom Size 36.131-38.463 +65.0 40.0 5@OR 5 12"NOM. Custom Size 36.131•38.463 +80.0 -110.0 EXTERIOR GLASS BITE EXTERIOR GLASS BITE F Z co n Custom Size 34.131-36.130 +65.0 40.0 EXTERIOR GLASS BITE Custom Size 34.131-36.130 +80.0 -110.0 a a w H¢-• _ 76" Standard Plaiew 30.994-34.130 +65.0 40.0 a 76" Standard Pmdex 30.994-34.130 +80.0 -110.0 U J ly rn Custom Size 30.131-30.993 +65.0 40.0 Custom Size 30.131-30.993 +80.0 -110.0 ®OR 5 70.73 ®OR 7673 Q ❑ Custom Size 26.131-30.730 +65.0 -80.0 70-73 Custom Size 28.131-30.130 +80.0 -110.0 GLASS TYPE 14 GLASS TYPE 15 _ 017!1 'asap sauaS ®5 OR 5B Shortest 26.194'-28.130 +65.0 -80.0 GLASS TYPE Shortest 26.194•-28.130 +80.0 -110.0 Egral4ite 42.464 «65.0 40.0 Eque4li1e 42.464 +80.0 -110.0 ���� .w,``�LYNN 84" Custom Size 38.131-42463 +80.0 "110.0 �� Q`v ,11 i 84" Custom Size 38.131-42.463 +65.0 40.0 ; .`�,.•�,�GEN3F Standard ProutW 34.194•-38.130 +65.0 40.0 Standard Pro4m 34.194'-38.130 +60.0 •110.0 ` ��• •�� •MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-49.391 NO.58705 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-48.391 - * �• Sl! MINIMUM SASH HEIGHT FOR FLANGED,RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-49.806 - - MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG,RADIUS TOP WINDOWS IS:BUCK HEIGHT-48.806 I •'�\ ��•.• STATE OF 1)TIP TO TIP DIMENSIONS SHOWN.FOR INTEGRAL FIN AND EQUAL-LEG WINDOWS,SUBTRACT 1"FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. //TONAL 0 2)FOR SIZES NOT SHOWN,ROUND UP TO THE NEXT AVAILABLE SIZE. AN=ANNEALED 3)FOR RADIUS TOP WINDOWS,FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. TP=TEMPERED 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF+65 PSF.NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. HS=HEAT STRENGTHENED A LYNN P.E.#58705 MILLER,P.E. TABLES: Anchor Quantities Required for Tip to Mlo Width "Through-Frame"Installation 18° 26' 1 33° 37° 1 41" 1 46' 1 49" 53-118" uSIna Glass Tvaes 1-7 Jamb Jamb Jamb �Isami Jamb Jamb Jamb Jamb Bottom Sesh u m ¢ rc m m mrrSash Height � m m m MDescription v o = o s b 'o far Given Range Range(in) $> m ¢ m ¢ m m TABLE 6B: m ¢ m ¢ m 24" Equal4te 12464 1 2 1 1 2 1 1 z 1 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 Glass Description(Listed from EXte rior to Interior) Equal-life 15.964 1 2 1 1 2 1 1 2 1 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 Type Ap;wocod 23 complAng with tta 31" Standard Pmdew 12.994-15.963 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 3 2 2 2 1 1/8"AN,.090"PVB,1/8"AN f'intid PwMirg C Shortest 12.464-12.993 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 13/16°LIG:1/8"AN CAP,AIRSPACE,118"AN,.090"PVB,118"AN Oote � Equal-lite 19.652 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 13116"LIG:1/8"TP CAP,AIRSPACE,1/8"AN,.090"PVB,118"AN •1j,,I Hiatal Dade Product Control Standard Proview 15.944-19.651 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 4 1/8"HS,.090"PVB,1/8"HS 38-318 Custom Size 15.131-15.943 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 5 3/16"AN,.090"PVB,3116"AN - Custom Size114.131-15A30 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 6 13116"LIG:3/16"AN CAP,AIRSPACE,1/8"AN,.090"PVB,118"AN Shortest 12.464-14.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 7 13/16"LIG:3116"TP CAP,AIRSPACE,1/8"AN,.090"PVB,1/8"AN Equal-lite 22.964 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Custom Size 20.131-22.983 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Standard PmVew 18.594-20.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 45" Custom Size 16.131-18.593 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 K Custom Size 16.131-16.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Custom Size 14.131-15.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Shortest 12464-14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Equal-lite 24.964 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 W z Y Custom Size 22.131-24.963 2 2 1 2. 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 m O 'naa w_ Standard Proview 20.194-22.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 0 ��rq+ O 0 49" Custom Size 18.131-20.193 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 '2 2 2 2 2 2 �• alo0 7 Custom Size 16.131-18.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 C7 N z w �' Custom Size 14.131-16.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 0 m N Z .. Shortest 12.464-14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 0 J O a to _ W O .& EquaFlite 25.777 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Z LL O o On r t Custom Size 24.131-25.776 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 0 U O' ®J u 4a ~ Standard Pm4ew 20.844-24.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 W co J M D o I...Z ¢ J 'eN Custom Size 20.131-20.843 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 W m ¢ 0M0 50.5!8' CD Custom Size 18.131-20.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 ' t ~ -Z .. O Z Custom Size 16.731-18,130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 � _ W Custom Sae 14.131-16.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 C7 CO LL Shortest 12.464-14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 CO O Equal-lite 31.964 2 3 1 2 3 1 2 3 1 2 3 2 7-3 2 2 3 2 2 3 2 2 3 2 m = to Custom Size 28.131-31.963 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 ® N J Standard Protiew 25.794-28.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 3 2 Ur F. Custom Size 24.131-25.793 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Z Z laays 63" Custom Size 22.131-24.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 j N Custom Size 20.131-22.130 3 2 1 3 2 1 3 2 7 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 LL 0 Q Custom Size 18.131-20.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 O Z 00 Custom Size 16.131-18.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 0 ~a _ jEqu.141te st 13.194'-16.130 4 2 1 4 2 1 4 2 1 4 2 2 4 2 2 4 2 2 4 2 2 4 2 2 U C.3 = 38,464 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 Q a Size 38.131-38.463 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 Size 34.131-36.130 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 32 3 3 2 3 3 2 76" Pmiew 30.994-34.130 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 ` 1t1YILYN///Size 30.131-30.993 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 ` 1 Size 28.131-30.130 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 '��.•'�1GEN$F'•����: Shortest 26.194'-28.130 4 2 1 4 2 1 4 2 1 4 2 2 4 2 2 4 2 2 4 2 2 4 3 2 Q�. Equal-lite 42.46q 3 4 1 3 4 1 3 4 1 3 4 1�! 3 42 3 4 2 3 4 2 3 4 2 1)TIP TO TIP DIMENSIONS SHOWN.FOR INTEGRAL FIN AND EQUAL-LEG WINDOWS, �SUBTRACT 1"FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THENO.58705 Custom Siie 38.131-42.463 3 4 1 3 4 1 3 4 1 3 4 3 4 2 3 4 2 3 4 2 3 4 2 WINDOWSIZE.Standard P.Vew 34.194'-38.130 4 3 1 4 3 1 4 3 1 4 3 4 3 2 4 3 2 4 3 2 4 3 2 - _- •MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-49.391 2)FOR SIZES NOT SHOWN,ROUND UP TO THE NEXTAVAILABLE SIZE. 1, :• MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-48.391 �O�•.. AT OF !(7�� MINIMUM SASH HEIGHT FOR FLANGED,RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-49.806 3)FOR RADIUS TOP WINDOWS,FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE P �� •.,FZORID ,. \C�` MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG,RADIUS TOP WINDOWS IS:BUCK HEIGHT-48.806 WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. i sS I•..... 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN X777/'011111 NN`` PRESSURE OF-65 PSF.NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. A.LYNN MILLER,P.E. P.E.#58705 n TABLE 7: Anchor Quantities Required for Tip to Tip Width "Through-Frame"Installation 18 25 33" 1 3T' 1 41" 1 45' 49" 53-1/8" u Inci Glass T e68-15 Jamb Jamb Jamb Jamb1,2 mb Jamb Jamb Jamb zBottom Sash � � � � � � � � � f � � � � � N � E 2 SashHeighDescriptionBari e n _ 'o s _ s = 6hr Given Range g �) -9 _ BS¢ m ¢ m ¢ m ¢ mm ¢ m ¢ m ¢ TABLE 7B: 24" Equal-lite 12.464 1 2 1 1 2 1 1 2 1 1 2 2 2 1 2 2 1 2 2 1 2 2 assEqual-lite 15.964 1 2 1 1 2 11 2 1 1 2 2 2 12 2 1 2 2 1 2 2 Type Description(Listed from Exterior to Interior) ApprovesWewntib 3M1t1t!31° Standard Prodew 12994.15.963 2 2 1 2 2 7 2 2 1 2 2 2 2 2 2 2 2 2 3 2 2 2 fbl 6 8 3116"AN,.090"SG,3/t6"AN DakShortest 12.454-12.993 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 t1QA#EquaNite 19.652 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 9 3116"HS,.090"SG,3116"HS Sg1x1W a Ptodud nh'8Standard Prmiew 15.944-19.651 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 10 13116"LIG:1/8"AN CAP,AIRSPACE,1/8"HS,.090"SG,1/B"HS 38-318" Custom Size 15.131-15.943 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 11 13!16"LIG:1/8"AN CAP,AIRSPACE,3116"AN,.090"SG,3/16"ANCustom Size 14.131•75.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 12 13/16"LIG:118"TP CAP,AIRSPACE,1/8"HS,.090"SG,1/8"HS Shortest 12.464-14.130 2 2 1 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 1 2 2 13 13116"LIG:118"TP CAP,AIRSPACE,3116"AN,.090"SG,3/16"AN Equal-lite 22.964 2 2 1 2 21 1 2 21 1 1 2 2 21 2 2 21 2 2 2 2 3 2 2 3 2 14 13/1 G'LIG:3/16"AN CAP,AIRSPACE, 1/8"HS,.090"SG,1/8"HS Custom Size 20.131-22.963 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 3 2 2 3 2 15 13/16"LIG:3/16"TP CAP,AIRSPACE, 1/8"HS,.D90"SG,118"HS _ Standard Prodew 18.594.20.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 3 2 45" Custom Size 16.131-18.593 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 p. Custom Size 15.131-16.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 Custom Size 14.131-15.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 Shortest 12464-14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 3 ci a0 `1 Equal-lite 24.964 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 W 3 rn Custom Size 22.131-24.963 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 w O O 'nay Standard Pro%iew 20.194-22.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 3 2 2 3 3 O 0 O 49" Custom Size 18.131-20.193 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 1"V) alo0 Custom Size 16.131-18,130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 3 (0 N z w Q Custom Size 14.131.18.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 0 0 u, rn Z Shortest 12.464-14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 O LL p n F W O Equal-lite 25.777 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 i d n Custom Size 24.131-25.776 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 U U O ~ 00 Standard Pro�iew 20.844-24.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 3 HW-'W coo¢ Q u DMD F: 50-5/B° Custom Size 20.131-20.843 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 Custom Size 18.131-20.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 3 3 p> 0 a 10 Custom Size 16.131-18.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 2 Z W Custom Size 14.131-16.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 f� J LL LL Shortest 12.464•14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 m 0 Equal-lite 31.964 2 3 1 2 3 1 2 3 1 2 3 2 2 3 2 2 3 2 2 3 2 2 4 3 2 (D Custom Size 28.131-31.963 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 3 3 4 3 ® J _ Standard ProNew 25.794-28.130 3 2 1 3 2 7 3 2 1 3 2 2 3 3 2 3 3 2 3 3 3 3 3 3 (� H Custom Size 24.131-25.783 3 2 1 3 2 1 3 2 1 3 2 2 3 3 2 3 3 2 3 3 3 3 3 3 Z Q laays W. Custom Size 22131-24.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 3 2 3 3 3 3 3 3 Custom Size 20.131-22.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 3 3 3 3 3 u_ OQ Custom Size 18.131-20.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 4 3 3 Z r Custom Size 16.131-18.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 4 2 3 4 2 3 2 n Shortest 13.194'-18.130 4 2 1 4 2 1 4 2 1 4 2 2 4 2 2 4 2 2 4 2 3 4 2 3 U = C) J Z f!) Equal-lila 38.464 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 4 2 3 4 3 3 4 3 Q Q Custom Size 36.131-38.453 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 4 2 3 4 3 3 4 3 aptasa0 saua5 Custom Size 34.131-36.130 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 4 2 3 4 3 3 4 3 76" Standard Prodew 30.994-34.130 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 4 3 4 4 3 Custom Size 30.131-30.993 3 3. 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 4 3 3 4 4 3 ���`��Ny .......LYNN Custom Size 28.131-30.130 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 4 3 2 4 3 3 4 4 3 `� Q .. . Shortest 26.194"-28.130 4 2 1 4 2 1 4 2 1 4 2 2 4 3 2 4 3 2 4 3 3 4 3 3 LtCENSF'•. Equal-lite 42.484 3 4 1 3 4 1 3 a 1 3 4 2 3 a 2 3 a 2 3 a 3 3 5 3 1)TIP TO TIP DIMENSIONS SHOWN.FOR INTEGRAL FIN AND EQUAL-LEG WINDOWS, Qa • tu" Custom Size 36.131 a 42446 3 4 1 3 4 1 3 4 1 a 4 2 3 a 2 a s z 4 a 3 4 5 3 SUBTRACT t"FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE Na.58705 WINDOW SIZE. Standard Pro%iew 34.1941-38.130 4 t 3 1 4 3 1 4 3 1 4 3 2 4 3 2 4 4 2 4 4 3 4 4 3 •MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-49.391 2)FOR SIZES NOT SHOWN,ROUND UP TO THE NEXT AVAILABLE SIZE. MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-48.391 MINIMUM SASH HEIGHT FOR FLANGED,RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-49.806 3)FOR RADIUS TOP WINDOWS,FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE �0,�'.,WSTF !(/` MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG,RADIUS TOP WINDOWS IS:BUCK HEIGHT-48.806 WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. i '•.FZORIO?•.•' \?� 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN �"74 70NAL ENG PRESSURE OF-65 PSF.NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. A.L'Y'44 MILLA P.E. P.E.#58705 INSTALLATION DETAILS FOR FLANGE FRAMES INSTALLATION OPTION 2 INSTALLATION OPTION 3 INSTALLATION ANCHORED THROUGH FRAME ANCHORED THROUGH FRAME AND 1X OPTION 1 EDGE DISTANCE DIRECTLY INTO CONCRETE/CMU. BUCKSTRIP INTO CONCRETE/CMU. ----- SEE NOTE 2,THIS SHEET. ANCHOREDTHROUGH f-' T �—� EMBEDMENT EMBEDMENT FRAME INTO 2X WOOD r— (+ 1/4"MAX SHIM 1/4"MAX SHIM �— FRAME OR BUCKSTRIP. I I SEE NOTE 2,THIS SHEET. C� EMBED- l 4 SASH VISIBLE 17 ° I JJ•.._.MENT I� EDGE a LIGHT WIDTH EDGE _ DISTANCE JJy— DISTANCE P:rov¢d ne:omp7yW8 Rlih t4° lrrc' L'c:din3 Cade 1!4"MAX SHIM 16 %OAi:l 27 L-- — ----L--J I_ FIXED VISIBLE ° fl^'e:S 9� !.Pre�ucl Ccetw SEE TABLE If LIGHT WIDTH �I 1 NOTE B,FOR °•• _ T�30 18 HEAD TYPE TYP.ANCHOR TYPE, 44 FIXED EMBEDMENTAND °' e VISIBLE EDGE DISTANCE PER LIGHT SUBSTRATE,SEE 31 5 OR 5B HEIGHT TABLE8. r= TIP TO TIP WIDTH - TYP.ANCHOR TYPE, 32 EMBEDMENTAND d a0 Y EXTERIOR EDGE DISTANCE PER LL ? (n TYP.ANCHOR TYPE, HORIZONTAL SECTION A-A 45 EMBEDMENT AND EDGE SUBSTRATE,SEE W w o °aa DISTANCE PER SUBSTRATE, TABLES. O m W 4 O SEE TABLE 8. —�{ 1!4"MAX.SHIM (D n O alas O 14 VISIBLE LIGHT FORMULAS: p F w CN O DADE APPROVED MULLION,FBC J r,¢ Z 46 55 (SHOWN FOR HI-RISE SILL;SEE J O a y Z O COMPLIANT ALUMINUM/STEEL FRAMING O 43 OR STEEL STUD.MAY BE VERTICAL OR SHEET 9 FOR STANDARD SILL) Z LL m i o^ o TIP 13 HORIZONTAL.SEE SUBSTRATE WIDTH U C) o ®R FO TIP 83 USE EITHER 1 PROPERTIES,TABLE B. @ Z V =a J u SASH 8 FIXED LITE:TIP TO TIP WIDTH-5.12" 'onl HEIGHT SWEEP LATCH @ - O W ¢ 5/'70 MIDSPAN OR 2 HEIGHT(EQUAL-LITE) }no .r > BOTTOM LOCKS TIP TO TIP HEIGHT12-3.73" r Z m Z INSTALLATION (, SASH HEIGHT(PROVIEW) VISIBLE OPTION 4 @FIXED LITE:TIP TO TIP HEIGHTI2+3.78" LL O LIGHT ANCHORED THROUGH @SASH:TIP TO TIP HEIGHT12-11.93" 2 Z r HEIGHT FRAME INTO METAL ® rn W O I - HEIGHT(CUSTOM SASH) — @FIXED LITE:TIP TO TIP HEIGHT-SASH HEIGHT-3.55" Z O 1aau5 @SASH:SASH HEIGHT-4.60" 7 U) EXTERIOR TABLE 8: LL X QO a33 Anchor Substrate Min.Edge Min.Embedment NOTES: = CW7 r_ 10 Distance W 2 ZQ r- 15 P.T.Southern Pine(SG=0.55) 9/16" 1-3/8" 1)USE ONLY SUBSTRATE-APPROPRIATE ANCHORS LISTED ON , J J M OPTIONAL HI-RISE #12 Steel, TABLE 8.FOLLOW EMBEDMENT AND EDGE DISTANCE LIMITS.ANY Q LL SILL SHOWN.SEE Aluminum,6063-T5 min. 3/8" 0.063° INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF 171/1 asap s S 42 18-8 Of 410 1"WEEP SHEET 10 FOR A36 Steel 3/8" 0.063" THE WINDOW. NOTCH AT STANDARD SILL. SS Screw \\1 I I I I I EACH END Steel Stud,Gr.33 Mn. 3/8" 0.045"(18 Ga) 2)MASONRY ANCHORS MAY BE USED INTO WOOD AS PER TABLE �``�\NY LYNN SH MAX.MAX• 8.ALL WOOD BUCKS LESS THAN 1-112"THICK ARE TO BE �` O SHIM Concrete(min.3.35 ksi) 1" 1-3/4" CONSIDERED 1X INSTALLATIONS.1X WOOD BUCKS ARE OPTIONAL ` ��•'•\,\CEN,p �!��' 1l4"410 SS -- --_ CreteFlex Ungrouted CMU,(ASTM C-90) 2-1/2" 1-1/4" IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE,WOOD BUCKS = Q P.T.Southern Pine(SG 0.55) 1" 1-318" DEPICTED AS 2X ARE 1-112"THICK OR GREATER.1X AND 2X BUCKS _ ;/ No.58705 • (WHEN USED)SHALL BE DESIGNED TO PROPERLY TRANSFER _ 7� NO ANCHORS Concrete(min.2.85 ksi) 1" 1-3/8" LOADS TO THE STRUCTURE.WOOD BUCK DESIGN AND = REQUIRED IN 1/4"Steel INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR rx� Ungrouted CMU,(ASTM C-90) 2-1/2" 1-1/4" ARCHITECT OF RECORD. 13 (/ FLANGE OR r Ultracon , / EQUAL-LEG P.T.Southern Pine(SG 0.55 1" 1-318" ��T '•.`CORIDP,.•' ��� FRAME SILLS a ° A)MIN.OF 3 THREADS BEYOND THE METAL SUBSTRATE. 3)VISIBLE LIGHT WIDTH OR HEIGHT(ALSO REFERRED TO AS ���s •••, . G B)USE ONLY FLATHEAD ANCHORS IN JAMBS.PAN/HEX/FLAT HEAD TYPE IS DAYLIGHT OPENING)IS MEASURED FROM BEADING TO BEADING. S10NAL 0 VERTICAL SECTION B-B ALLOWABLE FOR ANCHORS IN THE HEAD. '1/11111111\\\\ C)"UNGROUTED CMU"VALUES MAY BE USED FOR GROUTED CMU APPLICATIONS. A.LYNN MILLER,P.E. P.E.#58705 r INSTALLATION DETAILS FOR EQUAL-LEG FRAMES INSTALLATION OPTION 2 INSTALLATION OPTION 3 INSTALLATION ANCHORED THROUGH FRAME ANCHORED THROUGH FRAME AND IX EDGE DISTANCE DIRECTLY INTO CONCRETElCMU. BUCKSTRIP INTO CONCRETE/CMU. OPTIONI — —E------ SEE NOTE 2,THIS SHEET. ANCHORED THROUGH f T— T--1 EMBEDMENT FRAME INTO 2X WOOD I� EMBEDMENT FRAME OR BUCKSTRIP. 114"MAX SHIM 114"MAX SHIM �I ° SEE NOTE 2,THIS SHEET. D EMBED- I SASH VISIBLE 17 I ° EDGE �MENT EDGE „ LIGHT WIDTH 9graerad ea arnQryivgpfb l� DISTANCE 6:5ri d?n DISTANCE �'j'•1 II 1/4"MAX SHIM - Dale 19 _ 'h"JA1e 27 FIXED VISIBLE �ml`DPy Pm-du L ° LIGHT WIDTH `I 1��� SEE TABLE , 3 NOTE B,FOR 30 18 HEAD TYPE TYP.ANCHOR TYPE, 44 FIXED EMBEDMENTAND , VISIBLE EDGE DISTANCE PER LIGHT SUBSTRATE,SEE HEIGHT TABLE 8. ��31 5 OR 565 OR 56 66 BUCK WIDTH TYP.ANCHO\TYPE,, 32 EMBEDMEv. °0EXTERIOR EDGE DISTANLU z a5 TYP.ANCFioRTYPE, HORIZONTAL SECTION A-A > EMBEDMENT AND EDGE � SUBSTRATE,SEE w o O .�aa DISTANCE PER SUBSTRATE, TABLE 8. C3 o Ov SEE TABLE 8. o aloe O 14 --al Imo— 1/4"MAX.SHIM VISIBLE LIGHT FORMULAS: p vw O 46 55 I (SHOWN FOR HI-RISE SILL;SEE J J O ai _ Z O 43 SHEET 9 FOR STANDARD SILL) Z LL 0) o --� DADE APPROVED MULLION,FBC =W BUCK 13 COMPLIANTALUMINUMISTEEL FRAMING WIDTH W U HEIGHT 63 USE EITHER 1 OR STEEL STUD.MAY BE VERTICAL OR @ SASH 8 FIXED LITE:BUCK WIDTH-4.12" F-Lu ¢ J u m SWEEP LATCH @ HORIZONTAL.SEE SUBSTRATE O W ¢ Q phtp MIDSPAN OR 2 PROPERTIES,TABLE 8. HEIGHT(EQUAL-LITE) t`> R BOTTOM LOCKS BUCKHEIGHT2-3.23" Z q Z INSTALLATION C7 — SASH HEIGHT(PROVIE VISIBLE EQUAL OPTION 4 @FIXED LITE:BUCK HEIGHT2+4.2B" LL j ZO O LIGHT LEGBOX ANCHORED THROUGH @SASH:BUCK HEIGHT2-11.43" ,o S co HEIGHT FRAME FRAME INTO METAL ® N W IL— SHOWN SHOWN HEIGHT(CUSTOM SASH) @"XED LITE:BUCK HEIGHT-SASH HEIGHT-2.55' Z hays @SASH:SASH HEIGHT-4.60" V) X EXTERIORTABLE 8: 0 W 33 Anchor Substrate Min.Edge Min.Embedment NOTES: 12 Distance w Q 15 P.T.Southern Pine(SG=0.55) 9/16" 1-3/8" 1)USE ONLY SUBSTRATE-APPROPRIATE ANCHORS LISTED ON O J d W OPTIONAL HI-RISE #12 Steel, Aluminum6063-T5 min3/8" 0063" TABLE B.FOLLOW EMBEDMENT AND EDGE DISTANCE LIMITS.ANY Q W 42 SILL SHOWN.SEE 18-8 or 410 , . . INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF aAll �sap saua5 1"WEEP SHEET 10 FOR THE WINDOW. SS Screw A36 Steel 318" 0.063" NOTCH AT STANDARD SILL. Steel Stud,Gr.33 min. 3/8" 0.045" 18 Ga 2 MASONRY ANCHORS MAY BE USED INTO WOOD AS PER TABLE EACH END ( ) ) 1 NY LYN/V �SHi Concrete(min.3.35 ksi) 1" 1-3/4" 8.ALL WOOD BUCKS LESS THAN 1-12"THICK ARE TO BE �O . 1/4"410 SS CONSIDERED 1X INSTALLATIONS.1X WOOD BUCKS ARE OPTIONAL ��.•''U10ENgF'•.�� Ungrouted CMU,(ASTM C-90) 2-1/2" 1-1/4" IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE.WOOD BUCKS Q; CreteFlex DEPICTED AS 2X ARE 1-1/2"THICK OR GREATER.1X AND 2X BUCKS 'P P.T.Southern Pine(SG=0.55) 1" 1-318" = No.58705 NO ANCHORS (WHEN USED)SHALL BE DESIGNED TO PROPERLY TRANSFER '• 7� Concrete(min.2.85 ksi) 1" 1-3/8" LOADS TO THE STRUCTURE.WOOD BUCK DESIGN AND _— REQUIRED IN 1/4"Steel INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR INSTA •� y FLANGE OR •t Ungrouted CMU,(ASTM C-90) 2-1/2" 1-1/4" EQUAL-LEG Utracon ARCHITECT OF RECORD. %O S T OF FRAME SILLS ° P.T.Southern Pine(SG=0.55) 1" 1-318'METAL SUBSTRATE. 3)VISIBLE LIGHT WIDTH OR HEIGHT(ALSO REFERRED TO AS �i�Cc Ff ORIDP,.•' \��� • ° B)USE ONLY FLATHEAD ANCHORSNCDS BEYOND EN JAMBS. PANMEX/FLAT HEAD TYPE IS DAYLIGHT OPENING)IS MEASURED FROM BEADING TO BEADING. ,�7/ss1ONAL VERTICAL SECTION B-B ALLOWABLE FOR ANCHORS IN THE HEAD. l I r I I I 111111 C)"UNGROUTED CMU"VALUES MAY BE USED FOR GROUTED CMU APPLICATIONS. A LYNN MILLER,P.E. P.E.#58705 i INSTALLATION DETAILS FOR INTEGRAL FIN FRAMES EDGE EDGE DISTANCE DISTANCE f+ EMBEDMENT l O EDGE D DISTANCE 1/4"MAX SHIM 1/4"MAX SHIM 5 SASH VISIBLE 17 ,lppmred ae complying WW rta LIGHT WIDTH i &-iidtng g EMBEDMENT ?_ ' �• s N4➢k6 19 b+.izsfDsls mduxS Car.4ra 27 1/4"MAX. EMBEDMENT FIXEDVISIBLE ���JJJ 2 SHIMI i I r LIGHT WIDTH I 30 18 TYP.ANCHOR TYPE, FIXED EMBEDMENT AND EDGE VISIBLE DISTANCE PER SUBSTRATE, 44 SEE TABLE 9. LIGHT HEIGHT I 31 5 OR SB 5 BUCK WIDTH 32 r TYP.ANCHOR TYPE,SECTION C-C EMBEDMENT ti Y NDEDGE LU 45 DISTANCE PER SUBSTRATE,SEE w o nag DADE APPROVED MULLION,FBC TABLE 9.(NAIL SHOWN) p o p y COMPLIANT ALUMINUMISTEEL FRAMING >-IQ c y al°p O 14 1/4"MAX.SHIM Imo— OR STEEL STUD.MAY BE VERTICAL OR C9� F w O HORIZONTAL.SEE SUBSTRATE J n Z Z 43 PROPERTIES,TABLE s. VISIBLE LIGHT FORMULAS: Z u- coo m s Uj o^ BUCK (SHOWN FOR STANDARD SILL;SEE =W 13 SHEETS 7 OR 8 FOR HI-RISE SILL) W U 00 ®� -j °MO1O °N HEIGHTUSE EITHER 1 Z •Y ¢ J 63 9100R STEEL l- u oMo SWEEP LATCH @ WIDTH p W z MIDSPAN OR 2 46 55 SELF-DRILLING @ SASH&FIXED LITE:BUCK WIDTH-4.12" t` V' o. U) BOTTOM LOCKS SMS(G5),SEE TABLE 9. Z m Z U _ HEIGHT(EQUAL-LITE) .^-. SASH BUCK HEIGHT/2-3.23" Z Q W VISIBLE INSTALLATION Z) U 0 LIGHT15< HEIGHT(PROVIEW) HEIGHT OPTION 7 @FIXED LITE:BUCK HEIGHT/2+4.28" 11 J LU 0) ANCHORED THROUGH @SASH:BUCK HEIGHT/2-11.4T' C7 INTEGRAL FIN INTO METALZ Z 7aay5 HEIGHT(CUSTOM SASH) rq @FIXED LITE:BUCK I(EIGHT-SASH HEIGHT-2.55" ¢ J 16 STANDARD SILL @SASH:SASH HEIGHT-4.60" O p o EXTERIOR SHOWN.SEE Z ('1 33 PREVIOUS SHEET 7ML, v' 42 8 FOR OPTIONAL v LU 1" WWEEP HI-RISE SILL. J Zon NOTCH AT— EACH END 1/4"MAX TABLE 9: NOTES: nn '�sa0 sa;,a5 Min.Edge Min. SHIM Anchor Substrate Distance Embedment �� •i 1)USE ONLY SUBSTRATE-APPROPRIATE \�� ONY LYNgIM� 2-1/2"x.113"Box Nail P.T.Southern Pine(SG=0.55) 5/16" 2.438 ANCHORS LISTED ON TABLE 9.FOLLOW �` ��••�1GENSF •,�( ' 2-1/2"x.131"Common Nail P.T.Southern Pine(SG=0.55) 3/8" 2.438 EMBEDMENTAND EDGE DISTANCE LIMITS.ANY INSTALLATION OPTION SHOWN MAY BE USED Cib 2-1/2"x.145"Roofing Nail P.T.Southern Pine(SG=0.55) 3/8" 2.438 ON ANY SIDE OF THE WINDOW. � No.58705 TYP.ANCHOR TYPE, D : 7rc— EMBEDMENT AND EDGE EDGE DISTANCE 2-1/2"x.145"Roofing Nall P.T.Southern Pine(SG=0.55) 3/B" 2.438 /)1 = 2)VISIBLE LIGHT WIDTH OR HEIGHT(ALSO -0 ;(,( — I DISTANCE PER SUBSTRATE. _� P.T.Southern Pine(SG=0.55) 1/2" 1.375 REFERRED TO AS DAYLIGHT OPENING)IS SEE TABLE 9. #10 Steel Trusshead Screw or EMBEDMENT 0.125"Aluminum,6063-T5 min. 5/16" 0.125 MEASURED FROM BEADING TO BEADING. O (SCREW SHOWN #12 Steel,18-8 or 410 SS n Screw 0.050"A36Steel 5116" 0.05 %(�s'•.•a40RIO?. \? •'G . VERTICAL SECTION D-D 0.045"(18 Ga)Steel Stud,Gr.33 min. 5/16" 1 0.045ONAL CII�Oo\ A)MIN.OF 3 THREADS BEYOND THE METAL SUBSTRATE. //!1/IIIII A.LYNN MILLER,P.E. I P.E.#58705 If 2.560" 3.185" 2.060" 2.848" T T {t- .062" 1.125"2.846" L L 2.848" .062" .062" .062" 2.112" T 2.724" 2.724" 2.724" 1.489" 1 �Qriraa4 as cumCpylyigg wi16 th• .987" 1.125" Floti ?�Wing rL e D .062" .062" 1 ',udlaw6�,lnftl O FLANGE FRAME HEAD O HEAD FIN FRAME O EQUAL LEG FRAME HEAD O FLANGE FRAME JAMB O INTEGRAL FIN FRAME O EQUAL LEG FRAME JAMB 2.798" 2.798" 2.798" 2.798" 2.798" 2.798" z � Y 3.008" W] � 2.841" 3.466" 2.341" 3.508" 133" w O 0naa 4. e o o O .062" .062" -� .062" .062" . cp 062" .062" N i aloe O Q O ¢ . Z - J O a W CD Lr 61 0 1.125" U CJ ZLLCOo m n =LL) XE, r 1.125" o ®� MBp FLANGE FRAME SILL EQUAL LEG FRAME W 00 1.� J aN O FLANGE FRAME SILL sO EQUAL LEG FRAME SILL t0 HI-RISE + ±s SILL HI-RISE F-W u a ¢ / JMp Oa INTEGRAL FIN FRAME SILL J-INTEGRAL FIN FRAME O> 2.273" --►� ±± SILL-HI-RISE Z z 1 0 LL 1.300" .120" 1}}II 2.273" �I O .170' I SILICONE _ STRUCTURAL HOT-MELT BUTYL ® W POLYISOBUTYLENE 1/4"NOM. STRUCTURAL 3116"NOM. # 2.772" WITH SILICONE Z hays .062" DESICCANT FOAM WITH U) Z 2.211" 2.105" DESICCANT 2.150" 1.235" LL O Q .062" .062" EXT.GLASS O z (q o EXT.GLASS � 11 tl � I I --� 1.300" I+- INT.GLASS INT.GLASS v J X .062" +� 7.300" �- Q W 70 KODISPACE4SGTPS 71 SUPER SPACER'NXT TM p.l rosap sauag cs SASH TOP RAIL ±4 FIXED MEETING RAIL ±5 SASH BOTTOM RAIL- 7e HI-RISE SASH BOTTOM RAIL t7 SASH SIDE RAIL \7111111111/, ALUMINUM DESICCANT FILL � �77p...LYNN ���i� REINFORCEMENT POLYISOBUTYLENE ; ��.••�10ENS�M/��� 1.446" SEAL 5116"NOM. •• ij 634" 465" 617" 496" ROLL-FORMED SILICONE BE - No.58705 '• ] 1.522" -�{ � I• � �' � _ nh i ,627" BUTYL' UTYL 8 STAINLESS STEEL *1• .D40" DESICCANT - .813" ,802" .802' .802" FOAM -p /I EXT.GLASS %�O ' SAT OF �EXT.GLASS 1.370"HEADANCHOR P;112" .070" .045" .050" INT.GLASS INT.GLASS ���SS�O•••••• �`G�� 18 COVER 1e SASH STOP COVER �5A IG BEAD 58 IG SNAP BEAD 2B 5/16"LAMI BEAD x7 7116"LAM]BEAD ,7, L DURASEAL O ®SPACER O XL EDGE SPACER //1N I 11177 72 73 A.LYNN MILLER,RE. P.E.0 58705 II t t TABLE 11: #n' PGT Part# Description Material 51 ASSEMBLY DETAILS FOR 1 sazool Head,Flange um.6053-T6 FLANGE FRAMES 2 624017 Head,Integral Fin Alum.6063-T6 (OTHER FRAME TYPES SIMILAR). 3 624028 Head,Equal-leg Alum.6063-T6 a 4 624004 Jamb,Flange Alum.6063-T6 4 4A Jamb,Flange(Used For Alternate Radius Top Head) Alum.6063-T52 1 0 5 624020 Jamb,Integral Fin Alum.6063-T6 U_\ 1 t�provaG to comptyiag wNt+re. SA Jamb,Integral Fin(Used ForAltemate Radius Top Head) Alum.6063-752 D k E ��a 4c 6 624031 Jamb,Equal-leg Alum.6063-T6 &9t6a e�r�oductCosttra 6A Jamb,Equal-leg(Used For Altemate Radius Top Head) Alum.6063-T52 40 HEAD 7 624002 Sill,Flange Alum.6063-T6 010 p . 8 624018 Sill,Integral Fin Alum.6063-T6 INTERIOR 41 9 624029 Sill,Equal-leg Alum.6063-T6 , JAMB 10 624003 Sill,Hi-Rise,Flange Alum.6063-T6 11 624019 Sill,Hi-Rise,Integral Fin Alum.6063-T6 12 624030 Sill,Hi-Rise,Equal-leg Alum.6063-T6 0-11 14 a 13 624006 Sash Top Rail Alum.6005A-T61 14 624005 Fixed Meeting Rail Alum.6005A-T61 INTERIOR 15 624012 Sash Bottom Rail-Hi-Rise Alum.6063-T6 JAMB co Y 16 624068 Sash Bottom Rail Alum.6063-T6 W 3 7- 17 rq 17 s24007 Sash Side Rail Alum.6063-T6FIXED MEETING RAIL � _ w v p "n1a 18 624051 Head Anchor Co%er Alum.6053-T6 p o 19 624015 Sash Stop Alum.6063-T6 > W o a�o O 25A 624009 IG Bead Alum.6053-T50 v F w CO Z O 25B 624011 IG Snap Bead Alum.6063-T5 O-1 O w o 28 624013 5/16"Lam!Beading Alum.6063-T6 Z Li- m m n SASH BOTTOM RAIL = "' r` 27 624026 7/16"Lanni Beading Alum.6063-T6 C)U o ©� 're 30 6TP247 Glazing Bead,Bulb Vinyl for#624023 Vinyl SASH EW-z co < J uMo,o oN 31 6TP248 Glazing Bead,Bulb Vinyl for#624009&#624011 Vinyl 4 SIDE rL.—T on> -� oxo 32 724046 Sweep Latch(@ Tap Rail) Cast Zinc RAIL Z °��' o Z 33 624049 Bottom Latch(@ Sill) Alum.6053-T6 JAMB 34 Setting Block(1/8"X 1/2"X4") Neoprene r Z 0 35A IG Setting Block(1/6'X3/4"X4") Neoprene 359724014 IG Snap Setting Block Vinyl �' W W 36 724044 Bottom Rail Weatherstrip Extension 37 724053 Sill Gasket Polyethylene 37Z W ;d145 38 724054 Sash Top Rail Gasket Polyethylene c U) Z39 724055 Sash Bottom Rail Gasket Polyethylene LL O40 724057 Head Gasket Polyethylene Z U41 724063 Meeting Rail Gasket Polyethylene w 242 612260 Sash Bottom Rail Bulb Vinyl Polyethylene 39 E�\RIOR Q m rn 43 Weatherstrip,.270"x.187",Fin Seal(@ MR) 1�r,1 ,sa0 s, 44 67S16G Weatherstrip,.170"X.270",Fin Seal(@ Sash Side Rail) 45 46 varies Balance with Cover&Tn'r11atherstrip,.170" 1 Fin Seal(@ Top Sash Rall) Rigid Vin) `t1Y1 LYNA///�''�, g y SILL TABLE 10:MATERIAL PROPERTIES USED 51 781 PSQX #8 X 1"PH SMS(Assembly) Stainless Steel 51 FOR ANCHORAGE CALCULATIONS: ` _�•.• L�CENSF •,(� 55 7834AA #8X3/4"Ph.PN SMS(Balance) Stainless Steel 7 Material Min.Fy Min.F. Q 63 Alum.Screen with Fiberglass Mesh Varies Steel Screw 92 ksi 120 ksi _* No.58705 70 - K0 meriing Kodispace 4SG TPS INTERIOR 18$Screw 60 ksi 95 ksi See Sheet 410 Screw 90 ksi 110 ksi (� 71 Quanex Super Spacer nXT 10 for 51 0 g ;.� Elco UltraCorr� 155 ksi 177 ksi 72 - Quanex Duraseal Spacer Materials O '•. SAT OF 73 - Cardinal XL Edge Spacer NOTES: 410 SS Elco CmteFlex® 127.4 ksi 189.7 ksi T ''•,,F(ORIO P.•'.�_� 6063-75 Aluminum 16 ksi 22 ksi iS' NA 74 - Dow 791,899 or GE 7700 Backbedding Silicone 1)ALL CORNERS TO USE GASKET AND/OR SEALANT. A36 Steel 35 ksi 58 ksi ��, �� �. 2)SOME PARTS/OPTIONS NOT SHOWN ON DRAWING FOR CLARITY. Gr.33 Steel Stud 33 ksi 45 ksi //r I I I r A.LYNN MILLER,P,E. P.E.#58705 7,