HomeMy WebLinkAboutProduct Approval (3) i ♦ ° 1 1 a � t /
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications I Contact Us I E
Florida
Ow
Product Approval r (i USER: Public User
Product Approval Menu > Product or Application Search >Application List>Application Detail
FL# FL14605-R8
Application Type Revision
Code Version _ 2017
Application Status RECEIVED Approved
*Approved by DBPR. Approvals by DBPR shall be
JAN 14 9120 POC and/or the Commission if necessary.
Comments 5TH 6.�i 1 Ounty.Permitting
Archived u
Product Manufacturer Eastern Architectural Systems
Address/Phone/Email 16341 Domestic Ave.
Ft. Myers, FL 33912
(800) 432-2204 Ext 4305
jflesher@easternmetal.com _
Authorized Signature James Flesher
jflesher@easternmetal.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Sliding Exterior Door Assemblies
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation &Management Institute
Validated By National Accreditation &Management Institute
Referenced Standard and Year(of Standard) Standard
AAMA/WDMA/CSA 101/I.S.2/A440
ANSI/HAMA/NWWDA 101/I.S.2
ASTM E1886
ASTM E1886
ASTM E1996
TAS 201
TAS 202
TAS 203
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architec
FL14605 R8 Equiv FL14605.9,-Q., .11 and .15-
Product Approval Method Method 1 Option A
Date Submitted 09/17/2019
Date Validated 10/10/2019
Date Pending FBC Approval
Date Approved 10/17/2019
Sunimar
y of Products _.
FL.:# Model;Number.'®r Name Description
14605.1 Series 623 Impact Vinyl SGD Series 623 Impact Vinyl SGD
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL14605 R8 C CAC NI011134-R1.pi
Approved for use outside HVHZ: Yes Quality Assurance Contract Expira,
Impact Resistant: Yes 05/31/2021
Design Pressure: +50.0/-50.0 Installation Instructions
Other:.Maximum Size: 144" x 96" 3 Panel Bypass, 2-Track. FL14605 R8 II 08-01671A.p
FRAME MATERIAL TO BE RIGID PVC FROM DECEUNINCK NORTH Verified By: Luis R. Lomas, P.E. 6251,t
AMERICA AAMA CERTIFIED (DEP-1) Created by Independent Third Party:
Evaluation Reports
FL14605 R8 AE 512351A.pdf
Created by Independent Third Party:
14605.2 Series 623 Impact Vinyl SGD,., Series 623 Impact Vinyl SGD
Limits of Use Certification Agency Certificate
Approved for use in HVHZ;No FL14605 R8 C- CAC NI011134,01-R.
Approved for use outside HVHZ: Yes Quality Assurance Contract Expira-
Impact Resistant:Yes 05/3.1/2021
Design Pressure: +50.0/-50:0 Installation Instructions
Other: Maximum Size: 192":X-96"96" 4 Panel Bypass, 2- „ FU4605 R8 II'08-01670Apd
Track..FRAME MATERIAL TO BE RIGID PVC FROM DECEUNINCK Verified By: Luis R. Tomas, R E.'62514
NORTH AMERICA°HAMA CERTIFIED (DEP-1) Created by Independent ThirdParty:'
Evaluation Reports
FL14605 R8 AE 512350A.pa
Created by Independent Third Party:
14605.3 Series 623 Non-Impact Vinyl SGD Series 623 Non-Impact Vinyl SGD
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL14605 R8 C CAC NI011134.02-R:
Approved for use outside HVHZ: Yes Quality Assurance Contract Expira,
Impact Resistant: No 04/30/2021
Design Pressure: +50.0/-50.0 Installation Instructions
F..
Other: Maximum Size: 144" x 96" 3 Panel Bypass, 2-Track. FL14605 R8 II 08-01673A.p
FRAME MATERIAL TO BE RIGID PVC FROM DECEUNINCK NORTH Verified By: Luis R. Lomas, P.E. 6251, f
$- AMERICA AAMA CERTIFIED (DEP-1) Created by Independent Third Party:
Evaluation Reports
FL14605 R8 AE 512353A.pd
Created by Independent Third Party:
14605.4 Series 623 Non-Impact Vinyl SGD " Series 623 Non-Impact Vinyl SGD
Limits of Use Certification Agency Certificate
Approved for use in HVHZ .No PL14605 R8 C. CAC- N1011134,03-11
Approved
Approved for use outside HVHZ: Yes Quality Assurance Contract;Expira'"