HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2
Business & Professional Regulation
SCIS Home Log In User Registration Hot Topics Submit Surcharge I Stats&Facts I Publications Contact Us I BCIS Site Map I Links Search
rich
r
Product Approval
USER:Public User
Product Aooroval Menu>Product or Aoolication Search>Application List.>Application Detail -
FL# FL7804-R10
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived ❑
Product Manufacturer Entegra Roof Tile,LLC
Address/Phone/Email 1289 NE 9th Avenue
Okeechobee,FL 34972
(602)515-6933
thomas.jemmett@boral.com ir1J
�� ®�p-
Authorized Signature Thomas Jemmett i ��//
thomas.jemmett@boral.com bf*jq(Z-0��
Technical Representative RE�!iE Y E® FO R
Address/Phone/Email
CODE COMPLIANCE
CODE COMPLIANCE
Quality Assurance Representative ST. L U C I E C O U N T 9/'�
Address/Phone/Email
BOV�o W
C
Category Roofing
Subcategory Roofing Tiles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies,LLC.
Quality Assurance Contract Expiration Date 11/03/2020
Validated By John W. Knezevich,PE
0 Validation Checklist-Hardcopy Received
Certificate of Independence FL7804 R10 COI 2016 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM C1492 2003
FRSA/TRI April 2012 2012
SSTD 11 1997
r _ TAS 100 1995
TAS 101 1995
TAS 102 1995
- TAS 102(A) 1995
TAS 112 1995
Equivalence of Product Standards
Certified By
+` Sections from the Code
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgiiovOj OHI%2b.:. 1/9/2020
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 10/17/2017
Date Validated 10/19/2017
Date Pending FBC Approval 10/22/2017
Date Approved 12/12/2017
Summary of Products
FL Model,Number or Name Description
7804.1 Entegra Concrete Roof Tiles(HVHZ Concrete Roof Tile
jurisdictions)
Limits of Installation Instructions
-Appfoved for use in HVHZ:Yes FL7804 RSO II 2017 10 FINAL ER ENTEGRA FL7804-
Approved for use outside HVHZ:No RIO HVHZ.pdf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER Section 5 for Limits of Use. Refer to ER Evaluation Reports
Section 6 for Installation. FL7804 R10 AE 2017 10 FINAL ER ENTEGRA FL7804-
R10 HVHZ.odf
Created by Independent Third Party:Yes
'7804.2 Entegra Concrete Roof Tiles(non- Concrete Roof Tile
HVHZ jurisdictions)
Limits of use Installation Instructions
Approved for'use in HVHZ: No FL7804 R10 II 2017 10 FINAL ER ENTEGRA FL7804-
Approved for use outside HVHZ:Yes R10 NON-HVHZ.pdf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER Section 5 for Limits of Use. Refer to ER Evaluation Reports
Section 6 for Installation. FL7804 R10 AE 2017 10 FINAL ER ENTEGRA FL7804
R10 NON-HVHZ.pdf
Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 4SS,F.S.,please
click here.
Product Approval Accepts: '
FM FM 12
nn
Safe
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquovOj OHI%2b... 1/9/2020
EXTERIOR RESEARCH&DESIGN, LLC.
Certificate of Authorization#9503
ERD
353 CHRISTIAN STREET,UNIT#13�� ERD OXFORD,CT 06478
t. ..w._... .�.__.._.._ _ (203)262-9245
" EVALUATION REPORT
.TSF Entegra Roof Tile,LLC Evaluation Report E39310.11.11-1-R4
N9 1289 NE 9th Avenue FL7804-R10
; Okeechobee, FL 34972 Date of Issuance:11/02/2011
(602)515=6933 Revision 4:10/17/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3,and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6" Edition (2017) Florida Building Code
(HVHZ)sections noted herein.
DESCRIPTION: Entegra Concrete Roof Tiles (HVHZ jurisdictions)
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) -changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trinity ERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by. �rp�tnftnirr,,�
ze� Luz
Robert J.M:Nieminen P.E. :OS••�- ' T' The facsimileseal appearing was authorized byRobert Nieminen,
9� �S• �µe,1C.t_�.• P.E.on 10/17/2017.This does not serve as an electronically signed
Florida Registration No.59166,Florida DCA ANE1983 ,.''�ui^�V at E..`t+. document.Signed,sealed hardcopies have been transmitted to the
.....+�s Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity]ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRIM Y
ROOFING SYSTEM EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Roofing Tiles r
Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section. Prope Standard Year
1523.6.5.2 Physical Properties TAS 112 1995
1523.6.5.2 Wind Driven Rain TAS 100 1995
1523.6.5.2.2 Static Uplift Resistance TAS 101 1995
1523.6.5.2.3 Static Uplift Resistance TAS 102 1995
1523.6.5.2.3 Static Uplift Resistance TAS 102(A) 1995
3. REFERENCES:
Enti Examination Reference Date
ERD(TST6049) TAS 101 P39740.02.12 02/21/2012
ATL(TST3782) Physical Properties RT0624.05-14 07/03/2014
ATL(TST3782) Physical Properties RT0624.04-14 07/07/2014
ATL(TST3782) Physical Properties RT1210.02-15 12/17/2015
ATL(TST3782) Physical Properties RT1210.03-15 12/17/2015 d
ATL(TST 3782) Physical Properties RT1103.01-15 11/07/2015
ATL(TST 3782) Physical Properties RT1103.02-15 11/07/2015
ATL(TST 3782) Physical Properties RT1103.03-15 11/07/2015
ATL(TST 3782) Physical Properties RT1103.04-15 11/07/2015
ATL(TST 3782) Physical Properties RT1103.05-15 11/07/2015
Miami-Dade(CER1592) HVHZ Compliance 14-0416.12 11/27/2014
Miami-Dade(CER1592) HVHZ Compliance 15-0721.04 11/05/2015
Miami-Dade(CER1592) HVHZ Compliance 16-0112.06 02/25/2016
Miami-Dade(CER1592) HVHZ Compliance 16-0112.07 02/25/2016
Miami-Dade(CER1592) HVHZ Compliance 16-0112.08 02/25/2016
Tile Roof Institute TAS 100,TAS 101,102,102(A) Membership Confirmation Current
PRI(QUA9110) Quality Assurance Service Confirmation Exp.11/02/2018
Exterior Research and Design,I.I.C. Evaluation Report E39310.11.11-1-R4
certificate of Authorization 119503 6?"EDITION(2017)FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 2 of 8
rs TRIhIITY ERD
4. PRODUCT DESCRIPTION:
4.1 112,Types a flat•profil WMIBERME! A Fu►r,PtAarraTlo[+r FtaT an HoR�zaN Fta7
v
_ a
Bermuda Flat Plantation Flat
1
Horizon Flat
Exterior Research and Design;I.I.C. Evaluation Report E39310.11.11-1-R4
Certificate of Authorization#9503 6T"EDITION(2017)FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 3 of 8
a
-RINITY
3 ERD
4.2 �lS 112, ype 1a{i eebcking,high-profile} Be>lta Hii "S" MENEM
�.
4
Bella High
4.3 W TAS'112TjtP lb(inte lotik'tng lowprole}. EsratE; S andHact ►oA { R
NaitX3oles, .
ti
Estate"S" Hacienda
4.3 r , yp� 2 � e ry
s
...k
ry
1
J4' f
Galena Spanish"S" Regal
Exterior Research and Design,I.I.C. Evaluation Report E39310.11.11-1-R4
Certificate ofAuthorization#9503 CH EDITION(2017)FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 4 of 8
r
��_. TRINITY: Eta
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is for use in FBC-HVHZ jurisdictions or others adopting FBC HVHZ requirements.
5.3 Fire classification is not part of this evaluation; refer to FBC 1516 or listing by an approved testing agency for
fire rating of this product.
5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed tile roof installations.
5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in
accordance with TAS 112,Appendix W.
5.6 Minimum underlayment shall comply with the RAS 118; RAS 119 or RAS 120, as applicable. Underlayment
products shall hold current Florida Statewide Product Approval or Local Approval for use in tile roof
assemblies in FBC HVHZ jurisdictions.
5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements.
5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule
61G203.
6. INSTALLATION:
6.1 . Entegra Concrete Roof Tiles may be mechanically fastened,.mortar-set or adhesive-set. Installation shall
comply with manufacturer's current published instructions, but not less than the requirements of RAS 118, -
RAS 119 or RAS 120,as applicable.
6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment-Based System' in
accordance with Roofing Application Standard RAS 127-11 using the data outlined herein.
T14lE 1 dAERQpYNA IG MUETIP Eti5; 4(fes}
Tile Batten Application Direct-Deck Application
Bermuda Flat 0.189 0.205
Plantation Flat 0.267 0.289
Horizon Flat 0.305 0.330
Bella High"S" 0.349 0.378
Estate"S" 0.267 0.289
Hacienda 0.267 0.289
Galena Spanish"S" N/A 0.235
Regal 0.287 0.311
7ABLE[2: RESTORING MOM NTxDUE TO GRAUI7 -MGi(,T LBF} �;
Roof Slope(9)
Tile 2:12<0<3:12 3:12<0<4:12 4:12<9<5:12 5:12<9<6:12 6:12<0<7:12 9>7:12
Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct
Bermuda Flat 5.22 6.43 S.17 6.37 5.09 6.27 4.98 6.15 4.86 6.00 4.72 5.83
Plantation Flat 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04
Horizon 7.60 8.32 7.52 8.24 7.41 8.12 7.26 7.95 7.09 7.76 6.89 7.55
Bella High"S" 6.19 6.89 6.11 6.80 5.99 6.67 5.85 6.51 5.68 6.33. 5.50- 6.13
Estate"S" 6.14 6.84 5.91 6,74 5.82 6.64 5.70 6.50 5.56 6.33 5.40 6.14
Hacienda 5.92 6.80 5.92 6.80 5.82 6.69 5.70 6.55 5.S6 6.39 5.41 6.22
Galena Spanish"S" N/A 6.20 N/A. 6.13 N/A 6.03 N/A 5.89 N/A 5.74 N/A 5.57
Regal 7.77 8.34 7.77 8.34 7.65 8.20 7.49 8.03 7.30 7.83 -7.10 7.61
Exterior Research and Design,I.I.C. Evaluation Report E39310.11.11-1-R4
Certificate of Authorization#9503 6T"EDITION(2017)FBC HVHZ EVALUATION FL7804-R10
c Entegra Roof Tiles Revision 4:10/17/2017
Page 5 of 8
Q- J
TRII�IIY�ERDI
' 61.E 3A:ATTA[HNfENT RESISTAN EXPRESSED AS A MiDMEN7-Mffim _
(VIECHANtCAItY- TTAGHED SYSTEMS
Fastener Direct-Deck Direct-Deck
(min.15/32" (min.19/32"
Tile Type # Size Shank Clip plywood) plywood) Battens
Nail One(1) 10d Smooth or Screw N/A 7.3 9.8 4.9
Nail Two(2) lod Smooth or Screw N/A 14.0 18.8 7.4
Nail One(1) 10d Smooth or Screw Eave 19.0 19.0 22.1
Nail One(1) 10d Smooth or Screw Field- 24.3 24.3 24.2
Bermuda Flat, Nail Two(2) 10d Smooth or Screw Eave 31.9 31.9 32.2
Plantation Flat or Nail Two(2) 10d Smooth or Screw Field 35.5 35.5 34.8
Horizon Nail Two(2) 10d Ring N/A 30.9 38.1 17.2
Nail' Two(2)' 10d' Ring' N/A 50.31 65.51 48.31
Screw One(1) #8 N/A N/A 30.8 30.8 18.2
Screw Two(2) #8 N/A N/A 51.7 51.7 24.4
1 Installation with a 4-inch tile headlap and fasteners located min.2'/:-inch from head of tile.
Nail one(1)2 lod Smooth or Screw N/A 8.82 11.8, 4.12
Nail Two(2) 10d Smooth or Screw N/A 16.4 21.9 7.1
Nail One(1)2 10d Smooth or Screw Eave 19.02 19.0, 22:12
Nail one(1)2 10d Smooth or Screw Field 24.3, 24.32 24.2,
Nail Two(2) 10d Smooth or Screw Eave 31.9 31.9 32.2
Nail Two(2) 10d Smooth or Screw Field 35.5 35.5 34.8 '
Estate"S"or Hacienda
Nail Two(2) lOd Ring N/A 27.8 37.4. _ 28.8
Nail' Two(2)' 10d' Ring' N/A 43.01 67.51 50.9'
Screw One(1)2 #8 N/A N/A 25.82 25.82 22.92
Screw Two(2) ' #8 N/A N/A 47.1 47.1 49.1
1 Installation with a 4-inch tile headlap and fasteners located min.2%-inch from head of tile.
2 For one(1)fastener installations,utilize hole that is approximately 4%-inch from the interlocking edge.
Nail One(1) 10d Smooth or Screw N/A 5.1 6.8 2.8
Nail Two(2) 10d Smooth or Screw N/A 6.9 9.2 7.3
Nail One(1) 10d Smooth or Screw Field 23.1 23.1 19.0
Nail One(1) lod Smooth or Screw Eave 29.3 29.3 24.0
Nail Two(2) 10d Smooth or Screw Field 27.6 27.6 38.6
Bella High"S",.Galena Nail Two(2) lod Smooth or Screw Eave 1 38.1 38.1 41.8
Spanish"S"or Regal
Nail Two(2) 10d Ring N/A 28.6 41.2 19.4
Nail' Two(2)1 10d' Ring' N/A 33.1' 48.1' 50.9'
Screw One(1) #8 N/A N/A 20.7 20.7 18.1
Screw Two(2) #8 N/A N/A 43.2 43.2 29.8
'Installation with a 4-inch tile headlap and fasteners located min.2'/:-inch from head of tile.
Exterior Research and Design,I.I.C. Evaluation Report E39330.11.11-1-R4
Certificate ofAuthorizotion 89503 6T"EDITION(2017)FBC HVHZ EVALUATION FL7804-RIO
Entegra Roof Tiles Revision 4:10/17/2017
Page 6 of 8
;��TRII'�I1TYERa
• � to
AS 4 ATr ENr RESISTJINGE PREssED As Ao[,rrENT-MF jfr r e
MORTAR AND NESrVE-5ET SY
tVote from Frit na Roof Tile CCrn: The pe rrr�once data ttst ! Table 4 re used en the res ct+ve adhesi e : a curers'test
reports and s f-fade N As f gm R e ttG.reties upon he d eslve ufacturer v e these va es far aur i us O
/n this F8C N(%FtZ Evaluation Report. Please ult the in i ttlu t adhesive a ufocturer o in o anon on product approv l
tittaita#ons,revlsans or other 1' r otton for tntng wind aart andaye, rtt/n' ament perfov�rmance
Tile Adhesive
Tile Product Product Approval Placement Mf(ft-lbf)
"TILE BOND'"""by Dow Chemical NOA 16-0222.01 Interdependent(2-paddy) 41
Bermuda "Touch N'Seal Storm Bond"by DAP Foam NOA 16-0421.03 _Interdependent(2-paddy) 73
Flat, "Polyset®RTA-1"by ICP Adhesives&Sealants NOA 16-0315.03 Interdependent(2-paddy) 52
Plantation '
Interdependent(2-paddy) 43
Flat or -"Polyset®AH-160",by ICP Adhesives& NOA 17-0322.03 Independent medium add
Horizon Sealants P ( paddy,
"30 g) 51
Independent(large paddy,"'45 g) 92
"TILE BOND`by Dow Chemical, NOA-16-0222.01 Interdependent(2-paddy) 44
"Touch N'Seal Storm Bond"by DAP Foam NOA 16-0421.03 Interdependent(2-paddy) 42
°'Polyset®RTA-1"by ICP Adhesives&Sealants NOA 16-0315.03 Interdependent(2-paddy) 44
Estate"S"or I ,
Interdependent(2-paddy) 50
Hacienda "Polyset®AH-160"by ICP Adhesives&
NOA 17-0322.03 Independent(medium paddy,"30 g) 37
Sealants
Independent(large paddy,"'54 g) 61
j
Mortar Various Per RAS 120 21 .
"TILE BOND`by Dow Chemical- NOA 16-0222.01 Interdependent(2-paddy) 48
ouch N'Seal StQcm Bond"by DAR Foam NOA 16-0421.03 Interdependent(2-paddy) 52
Bella High "Polyset®RTA-1"by ICP Adhesives&Sealants NOA 16-0315.03 Interdependent(2-paddy) 36
"S",Galena
Interdependent(2-paddy) 30
Spanish"S" "Polyset®'AH-160"by ICP Adhesives&
or Regal NOA 17-0322.03' Independent(medium paddy,"30 g) 49
g Sealants
Independent(large paddy,-63 g) 94
Mortar Various Per RAS 120 25
7. LABELING:
7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo,as detailed
below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance
Agency noted herein.
and/or
E N T EM R R ,
Labeling:Bermuda Flat,Plantation Flat,Estate"S",Bella High"S",Galena Spanish"S"
Exterior Research and Design,I.I.C. Evaluation Report E39310.11.11-1-R4
Certificate ofAuthorization#9503 6T"EDITION(2017)FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 7 of 8
a
p
J
PT�INITYI'ERD,
'Q' 'and/or
on ,
Labeling:Horizon Flat,Hacienda,Regal
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
? nt1 ;�� -W' . . `-Profiles ,.
M
M
Okeechobee, FL Bermuda.Flat, Plantation Flat, Estate"S",Bella High"S",Galena Spanish"S t
Ft. Myers, FL Horizon Flat,Hacienda
Deerfield Beach, FL Horizon Flat, Hacienda, Regal `
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies, LLC.—QUA9110; (813)621-5777
-END OF EVALUATION REPORT—
Exterior Research and Design,I.I.C. Evaluation Report E39330.11.11-1-R4
Certificate of Authorization#9503 C"EDITION(2017)FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 8 of 8