EVALUATION REPORT
TRI-BUILT MtatiarTals Group, HC
PO Box 7C
Rutherford, NJ 07070
(800) 536.14a5
EXTERIOR RESEARCH & DESIGN, LLC.
Cerullo re of AvtharTivtlon #9503
353 CHJRJSTJAN STREL7, UNIT 913
OXFORD, CT 06478
(203) 262-9245
Eva luatton Report A42960.10.12-115
FL16048-R6
Date of Issuance:10f2Sf2012
Revision 6; 12512017
SCOPE;
This Evaluation Report Is issued under Rule 63620-3 and the applicable rules and regulations governing the use of
construction materials in the State of l=lorlda, The documentation submitted has been reviewed by Robert Merril nen,
P.E. for use of the product under the Florida Buiiding Code and Florida Building Code, Residential Volurne. The
products described herein have been evaluated for compliance with the a Edition (2E17� Florida rauilding Cade
sections noted herein_
DESCRIPTION: TRI-BUILT Real' U riderlayments
LABELING; Labellrg shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein,
CONTINUEDCompunrtct: This Evaluation Report is valid until such time asthe named products) changes, the referenced
Quality Assurance documentation changes, cr provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes ar the referenced Quality Assurance documentation changes. Trinity ERD requires a complete review of this
Eva Iua#ion Report relative to updated Code requirements with each Code Cycle,
ADVEwreEwitmt The Evaluation Report number precede i# by the words 'Wnity � ERD tvaaluato-6' may be displayed in
advertising fiterature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
MpEcnoji: Upon request, a copy of this entire Evacuation Report shall be provided to the user by the manufacturer or
itsdistributora and shall be available for inspection atthejob site at the request of the Building off ccial,
Thl5 Evaluation Report consists of pages 1 through 6.
Prepared by;
Robert J.M. Nieminen, P.E.
FloridD Regmtrution No. 54166, +=lefidu 0G4 ANSI-
Say rr, rF}u,
x
T �W4L T?*WsArle uN mppw" wu i6lh�arked by RAW Nkm7xn,
P.F_da 09fd M1I. Thk diet Bm turn iL in dKviv Alt Mped
d-ft
CERirFicATiori or IfVpEPwDocz:
1, Trinity M does not haver nor does it Intend to acqulre or will It acquire, a flnanciaf interest in any company manufacturing or
d istributing products it eva I uates.
2. TrIaltyI ERD is not awned, apErated or Controlled by arty company manufacturing or dfstributinE products it evaluates.
3. Robert Nieminen, P.E. does not have nor WRI acqu€re, a ffnaflcfai interest In any company manu€acturing or distributing products for
whlchthe evaluation reports are being Issued.
4. Robert Nleminen, P.E- &es not have, nor wFli acqufre, a financleI interest in any other entity iwolved fn the eDprcvaI process of the
product.
S. This fs a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.C. are, lh any way, the Designer of Record For any
project on which thIS Evaluation Report;, a previous versions thereof, Isfwa# used for permittln8 or desfgn gurdance unless retained
speelfirally for that pu rpose.
TRINITY ERD
ROOFLNG COMPONENT EVALUATION'
I. SCOPE:
Product Category: Roofing
Sub -Category. Underlayrnent
Compliance Statement: TRI-BUILT Rout Underlayrtlents, as produced by TRI-BUILT Materials Group, LLC, have
demonstrated compliance with thefollcwing sectiolls of the a Edition j2017) Fludda Building Cade through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations 1
Conditions of Use set forth herein.
2. STANDARDS:
Section
2504-3.1
1504.3-1
1504,E
1507,ZA / 1507.1,1,1507.2.4, 2
150733
3. REFERENCES:
Entity
ERG (TST54A9)
E RO {TST&349 i
ERD (T50049)
flab (T5T6049)
ERD (TST60491
ERD (T5T60491
E RD (TST6449)
ERG [TSTW49)
ERD MT60491
ERD (T5T60491
ERD (M6049)
ERO (TST6049)
ERG (TST60491
UL, LLC, (QUA9625)
UL, LLC. (QUA9625�
Property
Wind Rnista rice
Wind Uplift
Acceleratiad Weathering
Physical Properties
Physical Propertles
Exdmfnation
Physical Properties
ghYslcal Properties
Physical Propertie5
Physleal Properties
Physical Properties
RnyskaI Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
PfrySical Properties
Accelerated Weathering
Wind Resistance
Quality Colttrol
auatlty Control
Standard
year
FM 4474
2811
t1L 1897
2012
ASTM C155
2005
ASTM 01970
2015
FRSA/TRI April W12 (04.12)
2012
Reference
sans4G.02.13.1
S40540,11A3
540540.09.14
544870.04.14.2
SAdm70.04,14.3
S44870.0A.14.1
S44870,04,14-4
543530.02.14.1-R1
543530.05.14
5A0540.10.14
SC7645,02.15
SL8520.04.15
5C1404FPMA74;Z1
Ntultlple-Listing A16814
5ervite Confirmation
Date
02/19}]813
11f 39nola
03/26/2014
04102/2014
04/02/2014
04110j2014
04/1W2014
05114J2014
05f28f20kA
10131/2024
02119/2015
05/2712015
06f07/2017
12/1012015
Exp,07f1Sf2020
q, tkCr7ESCRIPTIOM:
4.1 TrFf3ullt Sand-R SA Shingle Underlayn►errt Is a self -adhering, glass -mat reinforced, sand -surfaced, SBS
modified bitumen roof underlayment, with a 36.1nch sheet width; meets AVM D1970.
4.2 Trl-guilt SJA HT TU 1Jnderlayment Is a self -adhering, non -woven polyester fabric surfaced, SBS rnodif-d
bitumen roof underlayment; meets ASTM D2970 and FRSA/TRI April 2012.
43 Tr#-Bu[it 5mooO fT S/A Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, 5B5
modified bitumen roof underlayment, meetsASTM 01970.
5, LIMITATIONS:
5-1 This Is a building code evaluation. Neither Trin[WIERD nor Robert Mervinen, P.E. are, In any way, the
Designer of Recofd for any project cn which this Evaluation Report, ar previous versians thereof, 1Slwa5
used for perrniitthig or design guidance unless retained spedfically for that purpose.
5.2 Thls Evaluatiorl Report is not for use In rBC EiVH2! jurasdicdons.
5.3 Fire Glasslflcation is not part of this EvaluatiOrl Report; refer to current Approved Roofing Materials
❑irectory far fire ratings of this product,
ExterWr Research and Design, LLC. Evaluatlon depart A42960.10, l t-Rfi
CertJfrcam Of AvOloybutiW 09503 G "EDMON I20171 FaC RDN-i4VHZ EVALIATIDR FL1GMA6
TAI•BUILT Roof underlayments; lR&3 516-IABS Revision 6; OWZWO17
Page 2 of 6
TRINITY ERa
5.4 TwBUILT Roof Undgdnments may he used with any prepared roof cover where the product Is
Specifically referenced within FUC approval documents, if not listed, a request Ina be data for the
de to the
Authority Hawing 3urisdickion for approval based on this evaluation cornrnlnad With sLppr}
prepared roof covering.
5,5 Aiinwnhlp Roof C +rer
TA81E 1: RaOrt QpvEFL op noNs
Wand Shakes skate
Asphalt NaiWnTile imam-onTlle Metal &Shingles
Underiayrnent Shingles
No Yes Yes
TrI Wit Son" 5A ShingYe I Yes 140 No
Undertgyment Yes
Yes Yes Yes
Trl-aulIt SfA HTTU Yes Y25 See 55,1
Underlayment I yes
NO Yes Yes
Tri-built Smooth HT SfA Yes No �.
Underlayment
5,51 "Foam -On Tile" islimYted to use of the followLng Approved titre adhesives / underlayment comlaIrla:ion5
TAjpL1E xA: AUMAZLETILE ADHSSSLVE I UNoERLAYMEwrCOM6LNAT16N51
t]nder]ayments
Adhesl+re Florkda product AP?*k
ICP AdheslVes polyset' AH460
FLb332 ` Tri•Buill 5fA FIT TU Unde layment
pav! T11e6ond2"
FL22545 Trl-fSvit#$IAHTTUUnderlayrnent
5,6 Allowable $bstratey
5A.1 Direct- *nd to Deck;
;T1�BuQt Sand-R 5A 54ring9e Underlaylnent, Tr'i�8ulkt Sf A HTTU lVrtrderlayrnent or Trl-Y3uilt Slt#ooth HT S/A
Underlayment applied to:
41
plywood: ASTM D41 primed plywood; MR, ASdI rD ct1+pr primal ed
0crke{ SoLftl+ern yellow Pine; ASTIR 0
primed Southern Yellow Pine, ASTM 441 p
ri While not required over plywood, 056 or Southern Yellow Pine substrates,
TRI-BUILT Materials GMUP, LL1C
recommends Pedals i3roup LLC requires l
TRI BtJILY I�rlatto g e and -groove board decking be Cvered with plrywaod Or
VSB priorta Inssallatlon of theself-adhering underlaymt-nt.
5,6.2 —Bond -ta-lnsu Ati n:
Trk-su>ilt Sand -A 5A Shingle Undellayment, Tri-Built 5/A HT TU Underlayme nt or Trl•8uikt Smooth HT 5 A
Underiayment applied to-
➢ Dens Deck Prime, SFGUROCK Gypsum -Fiber ROof BOard,
ared roof
For instalk2tYonu ant of he prepared rse attached pef
of covering manufaCtufersProduct tApprovalen lb l, ForInstallations
Tn
minimum reclulre
under foam -on tile systems {Tr�BuYlt SJA mT TU Undarlayment only}, Insulation attachment shall e
designed by a qualified design professlian and
Dln!S;t l orTM Sbased14, n te5dng of the insuYatYanfur-derlaYment
systerrr in auordante with FM 4474, Appendix
`Refer to Tie Nlan*ceLprers or AdheSlve M... jecturees Foar da Product 4p rouoJ far �verturrtl+rp fpmeAt ir¢slsCagtepOrfarmOrrcC,
EVp]uatlarn Rtpevt A429W,10.12-M
F L160A5-R6
Exterior Research and pesign. LLC. s"" EPrrION 12017] MC NON.HYN2 EVALUATION Mylswn rx O) Sf3017
Z%"ppw f o f Au#hwirorlon #9SR3 7RL_WJL7 Roof UndedaYMEMS. 00 515-1485 yap 3 of 6
TRINITY ERD
5.6.3 Bond to Mocha riically Attached Base Layer:
Trw3ufit Sand -RSA Shingle Undariayment, Trl-Etuilt S/A HT TU Underlayment or Tri-quilt Smooth HT S/A
Underlayment applied to:
>- ASTM D225, Type 1 or II felt.
For installations tinder mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -on the systems {Tri-quilt S/A HT TU
Undarlayment only), base layer shall be attached per minimum requirements of €RM/TRI April 2012 [D4-
12}.
5.6.4 wind Resistance for tired rla ment terns [ roam -On Tile A II atlons: FRSA/TRI Aptli 2012 (04-32
does not addr7ess wind uplift resistance of all underlayrnent systems beneath foam -on tile systems, v+-dec
k
the underiayment farms part of the load -path. The foilowing wind uplift limitations apply to direct dec
undedayment systems that are not addressed in FRSA/TRI April 2012 (04-121 and are used in foam -on the
applications. maximum Design Pressure is the result of testing for wind load resistance based on
allowable w[nd loads, and reflects the ultlmate passing pressure diM sled by 2 (the 2 to 1 margin of safety
per FBG 1504.9 has already been applied I. Refer to FRWTRI April 21112 {04-12jr Appendix A, Table 1A or
F13C 160D for determ[nati on of deslgr► wind pres cures.
#1 -Maxirngm Design
Pressure = -45.0 s '
requirements to satisfaction of Authority
Deck:
Min. 15/32-1nch plywood to meet project
Having Jurisdiction,
Primer,
(Optlonai) ASlfw+l D41 or FtESISTO INTERIOR PRIMER
Underlayment:
Tri-Built S/A HT TU Underlayment, self -adhered,
#t2 Maximum Pesi n
Deck.
prqssure =- . Sf:
Structural concrete to trivet project requirements to satlstaction of Authori#y Having
Jurisdiction.
Primer.-
5oprema Elastocol 50Cc
Underlayment;
Tri•BualtS/AHTTU U n d e r I ay rn e nt, self-adhered-
#3 Magimurn Desi en Press re = -15 4 sf:
Deck; Min, 15f32-inch APA-rated BCX plywood (may be Installed C €[de up1 to meet Project
requirements to satisfactlOn of Authority Hawing J u risd ictlon.
Deck Preparation, Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners shall be dr[ven flush with the surface. All sharp
spl[nters and wood projections shall be removed{sanded.
Primer' (nptional) RESISTO EXTERIOR PRIMER
Underlayment; Tt9-Wl t S/A HT TU Underlayment, self -adhered, shall be thoroughly roll using hand
roller and/or weighted roller to ensure there are no voids, and ensure there are no
volds/bridging at side and end -laps.
C.
#4 ximurn oval n Pre ure = - s
Deck, Min, 19J32-inch plywood to meet project requirements to satisfaction of Authority
Having JurlsdicNon.
Base Sheet: Soprema 5opra-G or modified 5epra-G mechanically attached with nails (F8C 1517,5,1}
and tin caps (I SC 15-17.5,2) spaced 5-inch o.c, atthe 4-inch laps and 6-inch o.c. in three,
equally spece-d rows In the center of the sheet.
Underiayment. Tr1-BulitS/AHTTUUndedaymentself-adhered.
Exterior RMAreh and Design. LLC, Ezra=uation Report AIZ960.10.12•R6
cimPart gFA4dhor nM03 hex f[]1TION 12o17i FBC NON-HVHZ EVALUATION FL16048-IRG
IA"UIL7 Roof Underlaymants; 19001 516-1465 Revision 6; p9j26/2017
page 4M6
TRINITY ERE)
5.6.4.1 For mechanically attached Base Sheet, the maximum design pre Table
1Athe cted assembly shall meet
r exceed that required under FRSA[rRi April Z012 (04-IZj, Append
Alternatively, the maximum design pressure for the selected assembly shall Meet Dr exceed the Zane 1
deslgrr pressure determined in accordance with ualified d sign professional to resist the elevated, zDne5 2 and �press'ure criteria.
attachment density designed by a a
Communly used rnethods are ANS115PRt WDi, FM Loss prevention Data Sheet 1-29 and Rooflin9
Applicaoon Standard RM 117, Assem4iles marked with an asterisk* tarry the 11mitations set forth In
Section 7.2,10,1 of FM Loss prevention Data Sheet 1-29 (January 2al6l for Zorte 2/9 enhancements.
5.7 E nsure LirMltati ns:
Trl-Bulit Sand-R 5A Shingle UnderlayMetlt or Td.Built 5modth 1iT S/A 43nderlayment shall not be left
exposed for longer tha n 30-days after installatlon after installation.
SIARTTU Underlayrnent shall not be I eft exposed for lortgerthan VW -days
%i,8
lie a Llmitat ns A5 1}3 r FR r A ri
5l 2 12 OBE-12
When loading roof tile$ on the underlayment in di rect-deck V 2 assemblies, the maximum roof slope sha
ll
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tl les.
Underlayrnent
irl-Built WA RT TI7
underlayment
fxterlor ResC0rt@ arnd 6e5�gn, LLCM
Certl ,Wr of Avthor&iNdOn #9503
TA81 E 2. TILE SUppAGE LkMrrnTk0XS FOR 111REa DECK tLE lHVAUA 20N5 malmum
Tile Profile Staging Method S101M
Flat stack Max.10-Llle 5112
egged
max. 10- ile stack 5:12
Max. 14tlle stack (bottom 241le stack
shall be Inverted, followed bV S tlle5 hlgh 6.72
on slope, as shown below)
Lugged
Eualuatlen Report A32960.10AZ-R6
FL1804 B-R 6
6"EOrnoN faovl rat ffn-tiVIiZN 516 in Revision 6: W2512017
TRl-BUILT Roo Undeftymmts, Wo, page 5 of 6
TRINITY ERD
G. INSTALLATION:
6.1 TRI-BUILT Roof Llnderleyments shall be Installed in accordance with TRI-RU&T Materials Group, LLC
published im5tallatlon requirements subject to the Limitations set forth in Section 5 heFgln and the
&petifics noted belnw_
61 Re -fasten any Ioo5e decking panels, and cherk for protruding nail heads. Sweep the substrate Ihorn ughay
to rem ave any dust anti debris prior to application, and prime the Substrate (if applicable).
6.3 T_ri Built Sand R SA Shingle UnderlaNfment Tri-Sulit.51A HT TU Untferlaument or Tri'§UL SmODth_I�T 51A
Underlayrnent•
6.3.1 Shall be installed in compliance with the requirements for ASTM ❑3970 underiayment in FOC Table
15071,1 for the type of prepared roof covering to be installed.
6-3-2 NQn-Tile aAuli€ations:
while prirning is optional, TRI-BUILT materials Group, LIC recamrnends priming the deck if the final roof
cower is not slated for instaIlaticn kwithIn 24 hours_
Apply cheat parallel tc the roof edge- Roll au[ approximately 10 ftof membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll tl+e remaining membrane asfar as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Flrmly roll, broom or nand -press the membrane into place to achleve a bond.
Horizontal seams Should be minimum 3-Inches, contlgured to shed water. Vertical seams should be 5-
Inche5 and staggered not less than 241 from vertical seams in the course below, sealed in accordance with
TRI-BUILT MateriaJs Group, LLC requirements.
When installipg at slopes above 8;32, TRI-BUILT Materials Group, LLC recommends back -nailing In the
overlap area at the top of the sheet at 12-inch o,G.
For Valleys and Rldges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and renter sheet
over valley er ridge_ brape and press sheet Into place, working from the center of the valley or ridge in
each directions. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications Tr -Built S A HT TU t nderlayment.4flY1=
Reference is made to FRSAITRE April 2012 (04-12) installation Manual and Table 1 hereinr using the
instructions noted above as a guideline,
Farfaam-,on rile applications, reference is ^fade to 5ectIon 5.6.4 herein far wind resistance (imitations that
fail outside the scope of FRSAITRI April 2012 (04-12).
Tile shall be landed and staged in a manner that prevents the slippage and/or damage to the
underlayment. See Table 2 herein, and TRI-BUILT Materlals. Group, LLC published requirements far the
staging.
7, BUILD114GPERMIT REgUIREMENTS:
As required by the Buileng Officlal or Authority Having Jurisdiction in order to properly evaluate the instal.latlon of
this product.
0. MANUFACTURING PLANT5:
Gulfport, MS
9. QUAUTY ASSURAFlc€ ENTITY:
UL, LLC— Qt1A9625, (314) 578-3406; k.chancellor@us.ul.com
END OF EVALUATION REPCRT-
Exterior Rrscore h and de sign, U Q- EWalua#ipn Report IU42960.10.12-R6
Certyk4lenfAurfror1zffUDn#9503 6`' EDIT 10412017iF&CROV-HVH7.FVALUATLON EL16018-RO
TRI B U ILT Roof Unde rlayme nts; tSXl 516-1485 RevISIVn 6: 09}2512017