HomeMy WebLinkAboutProduct Approval �-,�-Wim•----��----�- , - F - ���` � �f r�r�.. �` . , ,,q.
WEI,
�-.�.we'. __.�...) i�t�''.a'c'.�•a'�z.�i*�ry '+uz.{e�-�,,.�4°p.�'p-'w`"r""'.
dbBCIS Home Log In i User Registration Hot Topics Submit Surcharge Stats&Facts ; Publications Contact Us BCIS Site Map Links SearchG
::�Product Approval
i"
USER:Public User
Product Aooroval Menu>Product or Do cation Search>Application List>Application Detail
y FL# FL11842-R6
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived ❑
Product Manufacturer MFM Building Products Corp.
Address/Phone/Email 525 Orange St.
P.O.Box 340
Coshocton,OH 43812
(740)622-2645
wcroft@mfmbp.com
Authorized Signature James Buckner
jimmy@cbuckinc.net
Technical Representative Whit Croft
Address/Phone/Email PO Box 340
Coshocton,OH 43812
(740)622-2645 Ext 118
wcroft@mfmbp.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed James L. Bucker,P.E.@ CBUCK Engineering i 1�slypZ�
the Evaluation Report `�
®�
Florida License PE-31242 [��® ��
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 12/02/2021 gklve:� c®ot9�,���
Validated By Steven M. Urich,PE l�
D Validation Checklist-Hardcopy ,01)e C,tl: �®
Certificate of Independence FL11842 R6 COI CertificateOflndep.pdf ° '5 GG
Referenced Standard and Year(of Standard) Standard Year
ASTM D 1970 2015
TAS 103 1995
Equivalence of Product Standards i1e C®
Certified By Florida Licensed Professional Engineer or Architect
FL11842 R6 Eauiv FL11842 R6 Test Standard Enuiv.odf
Sections from the Code
r=
Product Approval Method Method 1 Option D
Date Submitted 02/22/2019
Date Validated 02/28/2019
Date Pending FBC Approval 03/01/2019
Date Approved 04/16/2019
Summary of Products
FL# Model,Number or Name Description
11842.1 1-"IB3","IB3 StormStopper","IB3 Self-Adhered Roof Underlayments attached to Plywood Deck
StormStopper FSU","IB3 Shingle
Starter","IB4 StormStopper"&
"Shingle Starter"(R5)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11842 R6 II 1 I63Family EVALREPORT RS.odf
Approved for use outside HVHZ:Yes Verified By:James L. Buckner,P.E. @ CBUCK,Inc P.E.
Impact Resistant:N/A #31242
Design Pressure: N/A Created by Independent Third Party:Yes
Other:Refer to Evaluation Report for Limitations and Evaluation Reports
Conditions of Use.Refer to Manufacturer's Installation FL11842 R6 AE 1 IB3Family EVALREPORT R5.odf
Instructions as a supplemental guide for attachment. Created by Independent Third Party:Yes
11842.2 2-"Peel&Seal"(R4) Self-Adhered Roof Underlayment attached to Plywood Deck
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11842 R6 II 2 PS EVALREPORT R4.pddf
Approved for use outside HVHZ:Yes Verified By:James L. Buckner,P.E. @ CBUCK,Inc P.E.
Impact Resistant:N/A #31242
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to Evaluation Report for Limitations and Evaluation Reports
Conditions of Use.Refer to Manufacturer's Installation FL11842 R6 AE 2 PS EVALREPORT R4.pdf
Instructions as a supplemental guide for attachment. Created by Independent Third Party:Yes
11842.3 3-"Ultra HT Wind&Water Self-Adhered Roof Underlayment attached to Plywood Deck
Seal"(R4)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11842 R6 II 3 UltraHT EVALREPORT R4.pdf
Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E. @ CBUCK,Inc P.E.
Impact Resistant:N/A #31242
Design Pressure: N/A Created by Independent Third Party:Yes
Other:Refer to Evaluation Report for Limitations and Evaluation Reports
Conditions of Use.Refer to Manufacturer's Installation FL11842 R6 AE 3 Ultra HT EVALREPORT R4.odf
Instructions as a supplemental guide for attachment. Created by Independent Third Party:Yes
11842:4 4-"Premium HT Tile&Metal"(R6) Self-Adhered Roof Underlayment attached to Plywood Deck,
with option to use with ICP Polyset AH160 or Dow TILE BOND
Roof Tile Adhesive
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11842 R6 II 4 Premium HT EVALREPORT R6.pdf
Approved for use outside HVHZ:Yes Verified By:James L. Buckner,P.E. @ CBUCK
Impact Resistant:N/A Engineering P.E. #31242
Design Pressure:+N/A/-52.5 Created by Independent Third Party:Yes
Other:Refer to Evaluation Report for Limitations and Evaluation Reports
Conditions of Use.Refer to Manufacturer's Installation FL11842 R6 AE 4 Premium HT EVALREPORT R6.odf
Instructions as a supplemental guide for attachment. Created by Independent Third Party:Yes
11842.5 5-"STS"(116) Self-Adhered Roof Underlayment attached to Plywood Deck
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11842 R6 II 5 STS EVALREPORT R6.pdf
Approved for use outside HVHZ:Yes Verified By:James L. Buckner,P.E. @ CBUCK
Impact Resistant:N/A Engineering P.E. #31242
Design Pressure: N/A Created by Independent Third Party:Yes
Other:Refer to Evaluation Report for Limitations and Evaluation Reports
Conditions of Use.Refer to Manufacturer's Installation FL11842 R6 AE S STS EVALREPORT R6.pdf
Instructions as a supplemental guide for attachment. Created by Independent Third Party:Yes
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please click hem.
Product Approval Accepts:
LP559 W--1 ::—
Credit Card
Safe
CBUCK N 11
E'nq1nPPr1nq
SpL=C1aff-Lj Struc:tura9 E=ng1ral=er1nc2 CBUCK,Inc.Certificate of Authorization#8064
Evaluation Report
"Ultra HT Wind & Water Seal7M11
Roof Underlayment
Manufacturer:
MFM Building Products Corp.
525 Orange Street
Coshocton, Ohio 43812
(740) 622-2645
for
Florida Product Approval
## FL 11842.3 R4
Florida Building Code 6th Edition (2017)
Method: 1 - D
Category: Roofing
Sub - Category: Underlayment
Product: "Ultra HT Wind &Water Seals"
Description: Self-Adhered Underlayment
Facsimile of digital copy signed by
Prepared by: James L.Buckner,P.E.
Electronically signed and sealed documents shall
James L. Buckner, P.E., SECB comply with the provisions of FAC Rule 61G15-23.
Florida Professional Engineer#31242 `� ,BUll,// ,
Florida Evaluation ANE ID: 1916 �S .• " " ti
Project Manager: Diana Galloway ;
Report No. 17-131-UHT-ER = * No 31242
(Revises 15-115-UHT-ER,FL11842.5 R3)
= LU=
Date: 07/09/17 0,�'• STATE OF
i�•• •F ORID �
Contents:
Evaluation Report Pages 1—5
2017.08.28 14:49:18-04'00'
CBUCK,Inc.dba CBUCK Engineering
Phone:(561)491-9927-Email:cbuck@cbuckincnet-website:www.cbuckinc.net
Business:1374 Community Dr.,Jupiter,FL 33458-Corp/Mailing:2637 E.Atlantic Blvd,#34069,Pompano Beach,FL 33062
FL#: FL 11842.3 R4
Date: 07/09/17
ll��
i C-.nq1ne=L=r1r1qReport No.: 17-131-UHT-ER
4
Page 2 of 5
Spsslaittj Structural Englf snaring CBUCK,Inc.Certificate of Authorization#8064
Manufacturer: MFM Building Products Corp.
525 Orange Street
Coshocton,Ohio 43812
(740) 622-2645
www.mfmbp.com
Product Name: "Ultra HT Wind &Water Sea ITM11
Product Category: Roofing
Product Sub-Category Underlayment
Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d)
Product Description: "Ultra HT Wind &Water SeaITM" is self-adhering membrane composed of a white,
non-slip cross-laminated polymer film, laminated to a rubberized asphalt adhesive
with a split release liner designed for use as a roof underlayment in high
temperature conditions.
Product Material/ Material Type: Styrene Butadiene Styrene(SBS)
Standards: Material shall comply with ASTM D 1970 per Florida Building Code FBC 6th Edition
(2017), Chapter 15.
Product Dimension(s) Roll Size:36 in.x 67 ft. rolls
Thickness:45 mils (nominal)
Substrate(s): "Ultra HT Wind & Water SeaITM" has been evaluated for application to the
following substrates (Design of support is outside the scope of this evaluation):
• Plywood
• Dens Deck
Installation: General Installation Instructions:
"Ultra HT Wind &Water SeaITM"shall be installed in accordance with the attached
installation method and in compliance with applicable code sections of the FBC
6th Edition (2017), subject to the Limitations and Conditions of Use listed in this
Evaluation Report.
Refer to installation details at the end of this report. Refer to manufacturer's
installation instructions as a supplemental guide for attachment.
FL#: FL 11842.3 R4
Date: 07/09/17
1nr1� Report No.: 17-131-UHT-ER
Il d Page 3 of 5
SpL =csil-y Structural E=ngirlP�r1nQ CBUCK,Inc.Certificate of Authorization#8064
Performance Standards: The product described herein has demonstrated compliance with:
• ASTM D 1970-15a — Specification Self-adhering Polymer Modified
Bituminous Sheet Materials Used as Steep Roof Underlayment for Ice Dam
Protection
Standards Equivalency: The ASTM D 1970-01 standard version used to test the product meets the
prescribed standards in ASTM D 1970-15a standard version adopted by the
Florida Building Code 6+th Edition (2017)for use as evaluated in this report.
Code Compliance: The product(s) described herein have demonstrated compliance with the
performance standards listed above as referenced in the current Florida Building
Code.
Evaluation Report Scope: This product has been evaluated in compliance with the building envelope
requirements of the Florida Building Code, as related to the scope section to
Florida Product Approval Rule 61G20-3.001.
Product Limitations and • Deck shall be in compliance with applicable building code.
Conditions of Use: • Minimum slope shall be 2:12 or greater.
• Installation is limited to use with approved roof coverings that are
mechanically fastened through the underlayment and is attached to the
sheathing or rafters.
• Not to be applied over active solvents or sealants, EPDM rubber or products
containing silicone.
• Do not expose product to direct sunlight for more than 60 days.
General Limitations and . Scope of"Limitations and Conditions of Use"for this evaluation:
Conditions of Use: This evaluation report for "Optional Statewide Approval' contains technical
documentation, specifications and installation method(s) which include
"Limitations and Conditions of Use" throughout the report in accordance with
Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is
the authority to approve products under"Optional Statewide Approval'.
• Option for application outside"Limitations and Conditions of Use"
Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific
approval by the local authorities having jurisdiction in accordance with the
alternate methods and materials authorized in the Code". Any modification of
the product as evaluated in this report and approved by the Florida Building
Commission is outside the scope of this evaluation and will be the
responsibility of others.
• This report is a building code product evaluation per FLPE rule (FAC) 61G15-36
to comply with Florida product approval rule (FAC) 61G20-3. This evaluation
report is part of the Florida Building Commission approval for the listed code
related criteria. This report by James Buckner, P.E. and CBUCK Engineering is
FL#: FL 11842.3 R4
Date: 07/09/17
ffTna 001-99Report No.: 17-131-UHT-ER
�J Page 4 of 5
SpeclaitIy Structural Enginserdr'i g CBUCK,Inc.Certificate of Authorization 118064
not a design certification of code compliance construction submittal
documentation, per FBC section 107, for any individual structure, site specific
or permit design.
• Design of support system is outside the scope of this report.
• Fire Classification is outside the scope of Rule 61G20-3, and is therefore not
included in this evaluation. `
• This evaluation report does not evaluate the use of this product for use in the
High Velocity Hurricane Zone code section. (Dade& Broward Counties)
Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.0005 (3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity through Keystone Certifications, Inc. (FBC Organization ID#QUA
1824).
Referenced Data: 1. ASTM D 1970-01 Test
By PRI Construction Materials Technologies, Inc.
(FBC Organization ID#TST 1556)
Report No. MFM-039-02-01, Date: 8/15/13
2. Equivalency of Test Standard Certification
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization#ANE 1916)
3. Quality Assurance
Keystone Certifications, Inc. (FBC Organization ID#QUA 1824)
MFM Building Products Corp. Licensee#335
4. Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization#ANE 1916)
FL M FL 11842.3 R4
Date: 07/09/17
CSUCK ``-® q1n r1 Page Report No.:5 -1351-UHT-ER
SPP8�11dn'tj Sf•r�.ear�1g1r1��:•llnr� CBUCK,Inc.Certificate of Authorization#8064
MFM Building Products Corp.
Ultra HT Wind & Water Seal
Self-Adhered Roofing Underlayment
General Installation Instructions:
• Product to be applied directly to a clean dry surface.
• Prime any weathered surfaces. Dens Deck must be primed with asphalt base primer.
• Starting at the low point of the deck, peel back 12"of the release liner, align the membrane and press into
place onto roof deck.
• Adhesive is pressure-activated,so press firmly into place using uniform pressure with a 2-3" heavy steel or
rubber roller to seams and overlap.
• Overlap end laps a minimum of 6".Side laps must be a minimum of 3".
• Store product in the carton in a dry place until ready to use. Keep product out of direct sunlight.
• Apply membrane only in fair weather when the air, surface and membrane are at a minimum temperature
of: 50° F
• Not to be applied over active solvents or sealants, EPDM rubber or products containing silicone.
• Do not expose product to direct sunlight for more than 60 days.
"Ultra HT Wind & Water SealT""" shall be installed in accordance with the attached installation method and in
compliance with applicable code sections of the FBC 6th Edition (2017), subject to the Limitations and
Conditions of Use listed in this Evaluation Report.
Refer to installation details at the end of this report. Refer to manufacturer's installation instructions as a
supplemental guide for attachment.
Product Illustrations
;:;ULTRA HT
WIND&WATER SEAL
gg��F��i
�f
y--
v
j -
,y YY
tl
'r _ iLLI t
PaBCIS Home Log In i User Registration i Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search
CY s
f:17' : Product Approval
��USER:Public User
r
Product Approval Menu>Product or Application Search>Application List>Application Detail
"4t .
FL# FL17022-R7
Application Type Revision
Code Version 2017
lm
Application Status Approved
Comments 08/18/2017v.date reapply 08/21/17
Archived ❑
Product Manufacturer Extreme Metal Fabricators,LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City,FL 34990
(772)872-8034
Flvalidation@yahoo.com
Authorized Signature Richard McKuhen
Flvalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City,FL 34990
(772)872-8034
richard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed LOCKE BOWDEN
the Evaluation Report
Florida License PE-49704 III/ '20L6
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/22/2024 "1
Validated By Zachary R. Priest,P.E.
❑ Validation Checklist-Hardcopy Received
Certificate of Independence FL17 22 R7 COI FL17022.1 5 V CR ao
df%00"r it A
Referenced Standard and Year(of Standard) Standard _®® if-
116A
� �®
TAS 125 5 ° �2003�000
UL 1897 2012
UL 580 2006
Equivalence of Product Standards ° ®��
Certified By l�
Sections from the Code
L: 1
Product Approval Method Method 1 Option D
Date Submitted 08/18/2017
Date Validated 08/25/2017
Date Pending FBC Approval 08/28/2017
Date Approved 10/10/2017
Summary of Products
um ear or Name Description
17022.1 - nmp a steel 3 8"rib height,24"wide lapped roo pa
mechanically attached to 15 p ywoo or oo
fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions. Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.odf
assembly in compliance with the installation method listed in Created by Independent Third Party:Yes
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.2 2-"5V Crimp"(116) 0.032"Aluminum,3/8"Rib height,21"wide lapped roof
panel,mechanically attached to 15/32"plywood or Wood
Deck with exposed fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 IT FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pdf
Approved for use outside HVHZ:Yes. Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions.Install the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032
assembly in compliance with the installation method listed in ALUM ssr.odf
this report and applicable code sections of FBC. Refer to Created by Independent Third Party:Yes
manufacturer's installation instructions.
17022.3 3-"1.5"Mechanical Seam"(115) 1.5"rib height, 16"wide,24 gauge steel,standing seam roof
panel mechanically attached to 15/32"plywood or wood deck
with clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022.3 1.5 MECHANICAL
Approved for use outside HVHZ:Yes seam 24ga ssr.odf
Impact Resistant:No Verified By: Locke Bowden,P.E.49704
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other:Refer to evaluation report for conditions and Evaluation Reports
limitations of use.Install the assembly in compliance with FL17022 R7 AE FL 17022.3 1.5 MECHANICAL
the installation method listed in this report and applicable seem 24ga ssr.pdf
code sections of FBC.Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
17022.4 4-"1.5"Mechanical Seam"(115) 1.5"rib height, 16"wide,0.032"aluminum,standing seam
roof panel mechanically attached to 15/32"plywood or Wood
Deck with clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022.4 MECHANCIAL SEAM
Approved for use outside HVHZ:Yes ALUMINUM ssr.odf
Impact Resistant:No Verified By: Locke Bowden,P.E.49704
Design Pressure: +N/A/-Table A Created by Independent Third Party:Yes
Other:Refer to evaluation report for conditions and Evaluation Reports
limitations of use.Install the assembly in compliance with FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
the installation method listed in this report and applicable ALUMINUM ssr.pdf
code sections of FBC.Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
17022.5 5-"1 in. Nail Strip"(115) 1"rib height, 16"wide,26 gauge steel,standing seam roof
panel mechanically attached to 15/32"plywood or wood deck
with fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.odf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.odf
limitations of use.Install the assembly in compliance with Created by Independent Third Party:Yes
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.6 6-"1 in.Nail Strip"(115) 1"rib height, 16"wide,0.032"aluminum,standing seam
roof panel mechanically attached to attached to 15/32"
plywood or Wood Deck with fasteners,
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032
Approved for use outside HVHZ:Yes _ALUM ssr.Ddf
Impact Resistant:No Verified By: Locke Bowden,P.E.49704
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other:Refer to evaluation report for conditions and Evaluation Reports
limitations of use.Install the assembly in compliance with FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032
the installation method listed in this report and applicable ALUM ssr.pdf
code sections of FBC. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
17022.7 7-"1.5 in. Nail Strip"(115) 1.5"rib height, 19"wide,26 gauge steel,standing seam roof
panel mechanically attached to 15/32"plywood or wood deck
with fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.0df
limitations of use.Install the assembly in compliance with Created by Independent Third Party:Yes
the installation method listed in this report and applicable
code sections of FBC.Refer to manufacturer's installation
instructions.
17022.8 8-"EMAX Rib"(115) 29 gauge steel,lapped roof panel mechanically attached to
15/32"plywood or wood deck with exposed fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 177022.8 EMAX Rib ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 177022.8 EMAX Rib ssr.Ddf
limitations of use.Install the assembly in compliance with Created by Independent Third Party:Yes
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.9 9-"PBR MAX"(115) 26 gauge steel,lapped roof panel mechanically attached to
15/32"plywood or wood deck with exposed fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022.9 PBR RIB ssr.odf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other: Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.9 PBR RIB ssr.Ddf
limitations of use.Install the assembly in compliance with Created by Independent Third Party:Yes
the installation method listed in this report and applicable
code sections of FBC.Refer to manufacturer's installation
instructions.
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please click here.
Product Approval Accepts:
z-z---j
Credit Card
Safe
i •
Report. i
-
3tors LLC
2160 SW Poma Drive
Palm City, FL 34990
772)872-8034
Florida Product Approvat# 17022.1 5- -V Crimp NON HiVHZ
Compliant with Florida Building Code 2017 (6th ed.) `
Compliant with Florida Product Approval Rule#61G20-3 _
Compliant: Keystone Certifications
s
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1 (Method 1 Attachment): #9 x 1-1/2" Hex-Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, &4 Attachment): #10 x 1-1/2" Hex-Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
See Fastener attachment specifications above
Install Details: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4
DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF
ROW SPACING 16"o.c. 16" o.c. 8"o.c. 6"o.c.
FASTENER SPACING (ALONG Panel width) 12" o.c. 12"o.c. 12"o.c. 12"o.c.
FASTENER SIZE 1 #9 #10 #10 #10
Reference Data: ARCHITECTURAL TESTING, INC.TST ID#: 1527
UL 580-06& 1897-041 Test Report X893.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-1? *Design pressure margin of safety 2:1
C 0. 80L�..''%
Locke Bowden,P.E.does not have,not will acquire a financial in U. qkm facturing or distributing products
under this evaluation. "
Locke Bowden,P.E.is not owned,operated,or controlled by a&coon paOornbbafaatureo,ordistributing products under this
report.
9
• _� r �'�J
STAT r:C4
f
r • �� &/
a
Ife
'�..�+'0NAL
I
FL17022.1 5V Crimp (26GA Steel), 24" Wide Roof Panel - Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7.This report does not imply warranty, installation, recommended product use outside of this report.
Fasteners-
#9 x 1-1/2"Min. or
#10 x 1-1/2"Min.per Table'A'for Row 5-V Crimp Roof Panel
Spacing and Design Pressures
Hex Washer Head Wood Screws
Q
1�v
Deck:
15/32"or greater Plywood,or
Wood plank
24"
12" 73J13"
OPTIONAL STRIATION.^-,
Panel Profile
Nominal 12" Nominal 12"
D.C. O.C.
Fasten
k9 x 1-1/2"Min. or #10 x 1-1/2"Min.per
-fable"A" Hex Washer Head Screw
Spaced 12"o.c.across the Panel Width
Panel Refer to Table"A"for Spacing Along Panel
Overlap Length
Deck-15/32"or greater
Plywood,or
-Wood plank