Loading...
HomeMy WebLinkAboutProduct Approval �-,�-Wim•----��----�- , - F - ���` � �f r�r�.. �` . , ,,q. WEI, �-.�.we'. __.�...) i�t�''.a'c'.�•a'�z.�i*�ry '+uz.{e�-�,,.�4°p.�'p-'w`"r""'. dbBCIS Home Log In i User Registration Hot Topics Submit Surcharge Stats&Facts ; Publications Contact Us BCIS Site Map Links SearchG ::�Product Approval i" USER:Public User Product Aooroval Menu>Product or Do cation Search>Application List>Application Detail y FL# FL11842-R6 Application Type Revision Code Version 2017 Application Status Approved Comments Archived ❑ Product Manufacturer MFM Building Products Corp. Address/Phone/Email 525 Orange St. P.O.Box 340 Coshocton,OH 43812 (740)622-2645 wcroft@mfmbp.com Authorized Signature James Buckner jimmy@cbuckinc.net Technical Representative Whit Croft Address/Phone/Email PO Box 340 Coshocton,OH 43812 (740)622-2645 Ext 118 wcroft@mfmbp.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed James L. Bucker,P.E.@ CBUCK Engineering i 1�slypZ� the Evaluation Report `� ®� Florida License PE-31242 [��® �� Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 12/02/2021 gklve:� c®ot9�,��� Validated By Steven M. Urich,PE l� D Validation Checklist-Hardcopy ,01)e C,tl: �® Certificate of Independence FL11842 R6 COI CertificateOflndep.pdf ° '5 GG Referenced Standard and Year(of Standard) Standard Year ASTM D 1970 2015 TAS 103 1995 Equivalence of Product Standards i1e C® Certified By Florida Licensed Professional Engineer or Architect FL11842 R6 Eauiv FL11842 R6 Test Standard Enuiv.odf Sections from the Code r= Product Approval Method Method 1 Option D Date Submitted 02/22/2019 Date Validated 02/28/2019 Date Pending FBC Approval 03/01/2019 Date Approved 04/16/2019 Summary of Products FL# Model,Number or Name Description 11842.1 1-"IB3","IB3 StormStopper","IB3 Self-Adhered Roof Underlayments attached to Plywood Deck StormStopper FSU","IB3 Shingle Starter","IB4 StormStopper"& "Shingle Starter"(R5) Limits of Use Installation Instructions Approved for use in HVHZ: No FL11842 R6 II 1 I63Family EVALREPORT RS.odf Approved for use outside HVHZ:Yes Verified By:James L. Buckner,P.E. @ CBUCK,Inc P.E. Impact Resistant:N/A #31242 Design Pressure: N/A Created by Independent Third Party:Yes Other:Refer to Evaluation Report for Limitations and Evaluation Reports Conditions of Use.Refer to Manufacturer's Installation FL11842 R6 AE 1 IB3Family EVALREPORT R5.odf Instructions as a supplemental guide for attachment. Created by Independent Third Party:Yes 11842.2 2-"Peel&Seal"(R4) Self-Adhered Roof Underlayment attached to Plywood Deck Limits of Use Installation Instructions Approved for use in HVHZ:No FL11842 R6 II 2 PS EVALREPORT R4.pddf Approved for use outside HVHZ:Yes Verified By:James L. Buckner,P.E. @ CBUCK,Inc P.E. Impact Resistant:N/A #31242 Design Pressure:N/A Created by Independent Third Party:Yes Other:Refer to Evaluation Report for Limitations and Evaluation Reports Conditions of Use.Refer to Manufacturer's Installation FL11842 R6 AE 2 PS EVALREPORT R4.pdf Instructions as a supplemental guide for attachment. Created by Independent Third Party:Yes 11842.3 3-"Ultra HT Wind&Water Self-Adhered Roof Underlayment attached to Plywood Deck Seal"(R4) Limits of Use Installation Instructions Approved for use in HVHZ: No FL11842 R6 II 3 UltraHT EVALREPORT R4.pdf Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E. @ CBUCK,Inc P.E. Impact Resistant:N/A #31242 Design Pressure: N/A Created by Independent Third Party:Yes Other:Refer to Evaluation Report for Limitations and Evaluation Reports Conditions of Use.Refer to Manufacturer's Installation FL11842 R6 AE 3 Ultra HT EVALREPORT R4.odf Instructions as a supplemental guide for attachment. Created by Independent Third Party:Yes 11842:4 4-"Premium HT Tile&Metal"(R6) Self-Adhered Roof Underlayment attached to Plywood Deck, with option to use with ICP Polyset AH160 or Dow TILE BOND Roof Tile Adhesive Limits of Use Installation Instructions Approved for use in HVHZ: No FL11842 R6 II 4 Premium HT EVALREPORT R6.pdf Approved for use outside HVHZ:Yes Verified By:James L. Buckner,P.E. @ CBUCK Impact Resistant:N/A Engineering P.E. #31242 Design Pressure:+N/A/-52.5 Created by Independent Third Party:Yes Other:Refer to Evaluation Report for Limitations and Evaluation Reports Conditions of Use.Refer to Manufacturer's Installation FL11842 R6 AE 4 Premium HT EVALREPORT R6.odf Instructions as a supplemental guide for attachment. Created by Independent Third Party:Yes 11842.5 5-"STS"(116) Self-Adhered Roof Underlayment attached to Plywood Deck Limits of Use Installation Instructions Approved for use in HVHZ: No FL11842 R6 II 5 STS EVALREPORT R6.pdf Approved for use outside HVHZ:Yes Verified By:James L. Buckner,P.E. @ CBUCK Impact Resistant:N/A Engineering P.E. #31242 Design Pressure: N/A Created by Independent Third Party:Yes Other:Refer to Evaluation Report for Limitations and Evaluation Reports Conditions of Use.Refer to Manufacturer's Installation FL11842 R6 AE S STS EVALREPORT R6.pdf Instructions as a supplemental guide for attachment. Created by Independent Third Party:Yes Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click hem. Product Approval Accepts: LP559 W--1 ::— Credit Card Safe CBUCK N 11 E'nq1nPPr1nq SpL=C1aff-Lj Struc:tura9 E=ng1ral=er1nc2 CBUCK,Inc.Certificate of Authorization#8064 Evaluation Report "Ultra HT Wind & Water Seal7M11 Roof Underlayment Manufacturer: MFM Building Products Corp. 525 Orange Street Coshocton, Ohio 43812 (740) 622-2645 for Florida Product Approval ## FL 11842.3 R4 Florida Building Code 6th Edition (2017) Method: 1 - D Category: Roofing Sub - Category: Underlayment Product: "Ultra HT Wind &Water Seals" Description: Self-Adhered Underlayment Facsimile of digital copy signed by Prepared by: James L.Buckner,P.E. Electronically signed and sealed documents shall James L. Buckner, P.E., SECB comply with the provisions of FAC Rule 61G15-23. Florida Professional Engineer#31242 `� ,BUll,// , Florida Evaluation ANE ID: 1916 �S .• " " ti Project Manager: Diana Galloway ; Report No. 17-131-UHT-ER = * No 31242 (Revises 15-115-UHT-ER,FL11842.5 R3) = LU= Date: 07/09/17 0,�'• STATE OF i�•• •F ORID � Contents: Evaluation Report Pages 1—5 2017.08.28 14:49:18-04'00' CBUCK,Inc.dba CBUCK Engineering Phone:(561)491-9927-Email:cbuck@cbuckincnet-website:www.cbuckinc.net Business:1374 Community Dr.,Jupiter,FL 33458-Corp/Mailing:2637 E.Atlantic Blvd,#34069,Pompano Beach,FL 33062 FL#: FL 11842.3 R4 Date: 07/09/17 ll�� i C-.nq1ne=L=r1r1qReport No.: 17-131-UHT-ER 4 Page 2 of 5 Spsslaittj Structural Englf snaring CBUCK,Inc.Certificate of Authorization#8064 Manufacturer: MFM Building Products Corp. 525 Orange Street Coshocton,Ohio 43812 (740) 622-2645 www.mfmbp.com Product Name: "Ultra HT Wind &Water Sea ITM11 Product Category: Roofing Product Sub-Category Underlayment Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) Product Description: "Ultra HT Wind &Water SeaITM" is self-adhering membrane composed of a white, non-slip cross-laminated polymer film, laminated to a rubberized asphalt adhesive with a split release liner designed for use as a roof underlayment in high temperature conditions. Product Material/ Material Type: Styrene Butadiene Styrene(SBS) Standards: Material shall comply with ASTM D 1970 per Florida Building Code FBC 6th Edition (2017), Chapter 15. Product Dimension(s) Roll Size:36 in.x 67 ft. rolls Thickness:45 mils (nominal) Substrate(s): "Ultra HT Wind & Water SeaITM" has been evaluated for application to the following substrates (Design of support is outside the scope of this evaluation): • Plywood • Dens Deck Installation: General Installation Instructions: "Ultra HT Wind &Water SeaITM"shall be installed in accordance with the attached installation method and in compliance with applicable code sections of the FBC 6th Edition (2017), subject to the Limitations and Conditions of Use listed in this Evaluation Report. Refer to installation details at the end of this report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. FL#: FL 11842.3 R4 Date: 07/09/17 1nr1� Report No.: 17-131-UHT-ER Il d Page 3 of 5 SpL =csil-y Structural E=ngirlP�r1nQ CBUCK,Inc.Certificate of Authorization#8064 Performance Standards: The product described herein has demonstrated compliance with: • ASTM D 1970-15a — Specification Self-adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roof Underlayment for Ice Dam Protection Standards Equivalency: The ASTM D 1970-01 standard version used to test the product meets the prescribed standards in ASTM D 1970-15a standard version adopted by the Florida Building Code 6+th Edition (2017)for use as evaluated in this report. Code Compliance: The product(s) described herein have demonstrated compliance with the performance standards listed above as referenced in the current Florida Building Code. Evaluation Report Scope: This product has been evaluated in compliance with the building envelope requirements of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Product Limitations and • Deck shall be in compliance with applicable building code. Conditions of Use: • Minimum slope shall be 2:12 or greater. • Installation is limited to use with approved roof coverings that are mechanically fastened through the underlayment and is attached to the sheathing or rafters. • Not to be applied over active solvents or sealants, EPDM rubber or products containing silicone. • Do not expose product to direct sunlight for more than 60 days. General Limitations and . Scope of"Limitations and Conditions of Use"for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval' contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under"Optional Statewide Approval'. • Option for application outside"Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to comply with Florida product approval rule (FAC) 61G20-3. This evaluation report is part of the Florida Building Commission approval for the listed code related criteria. This report by James Buckner, P.E. and CBUCK Engineering is FL#: FL 11842.3 R4 Date: 07/09/17 ffTna 001-99Report No.: 17-131-UHT-ER �J Page 4 of 5 SpeclaitIy Structural Enginserdr'i g CBUCK,Inc.Certificate of Authorization 118064 not a design certification of code compliance construction submittal documentation, per FBC section 107, for any individual structure, site specific or permit design. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. ` • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade& Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.0005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization ID#QUA 1824). Referenced Data: 1. ASTM D 1970-01 Test By PRI Construction Materials Technologies, Inc. (FBC Organization ID#TST 1556) Report No. MFM-039-02-01, Date: 8/15/13 2. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) 3. Quality Assurance Keystone Certifications, Inc. (FBC Organization ID#QUA 1824) MFM Building Products Corp. Licensee#335 4. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) FL M FL 11842.3 R4 Date: 07/09/17 CSUCK ``-® q1n r1 Page Report No.:5 -1351-UHT-ER SPP8�11dn'tj Sf•r�.ear�1g1r1��:•llnr� CBUCK,Inc.Certificate of Authorization#8064 MFM Building Products Corp. Ultra HT Wind & Water Seal Self-Adhered Roofing Underlayment General Installation Instructions: • Product to be applied directly to a clean dry surface. • Prime any weathered surfaces. Dens Deck must be primed with asphalt base primer. • Starting at the low point of the deck, peel back 12"of the release liner, align the membrane and press into place onto roof deck. • Adhesive is pressure-activated,so press firmly into place using uniform pressure with a 2-3" heavy steel or rubber roller to seams and overlap. • Overlap end laps a minimum of 6".Side laps must be a minimum of 3". • Store product in the carton in a dry place until ready to use. Keep product out of direct sunlight. • Apply membrane only in fair weather when the air, surface and membrane are at a minimum temperature of: 50° F • Not to be applied over active solvents or sealants, EPDM rubber or products containing silicone. • Do not expose product to direct sunlight for more than 60 days. "Ultra HT Wind & Water SealT""" shall be installed in accordance with the attached installation method and in compliance with applicable code sections of the FBC 6th Edition (2017), subject to the Limitations and Conditions of Use listed in this Evaluation Report. Refer to installation details at the end of this report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Product Illustrations ;:;ULTRA HT WIND&WATER SEAL gg��F��i �f y-- v j - ,y YY tl 'r _ iLLI t PaBCIS Home Log In i User Registration i Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search CY s f:17' : Product Approval ��USER:Public User r Product Approval Menu>Product or Application Search>Application List>Application Detail "4t . FL# FL17022-R7 Application Type Revision Code Version 2017 lm Application Status Approved Comments 08/18/2017v.date reapply 08/21/17 Archived ❑ Product Manufacturer Extreme Metal Fabricators,LLC Address/Phone/Email 2160 SW Poma Drive Palm City,FL 34990 (772)872-8034 Flvalidation@yahoo.com Authorized Signature Richard McKuhen Flvalidation@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City,FL 34990 (772)872-8034 richard@emfab.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed LOCKE BOWDEN the Evaluation Report Florida License PE-49704 III/ '20L6 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 04/22/2024 "1 Validated By Zachary R. Priest,P.E. ❑ Validation Checklist-Hardcopy Received Certificate of Independence FL17 22 R7 COI FL17022.1 5 V CR ao df%00"r it A Referenced Standard and Year(of Standard) Standard _®® if- 116A � �® TAS 125 5 ° �2003�000 UL 1897 2012 UL 580 2006 Equivalence of Product Standards ° ®�� Certified By l� Sections from the Code L: 1 Product Approval Method Method 1 Option D Date Submitted 08/18/2017 Date Validated 08/25/2017 Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 Summary of Products um ear or Name Description 17022.1 - nmp a steel 3 8"rib height,24"wide lapped roo pa mechanically attached to 15 p ywoo or oo fasteners Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.pdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions. Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.odf assembly in compliance with the installation method listed in Created by Independent Third Party:Yes this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.2 2-"5V Crimp"(116) 0.032"Aluminum,3/8"Rib height,21"wide lapped roof panel,mechanically attached to 15/32"plywood or Wood Deck with exposed fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 IT FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pdf Approved for use outside HVHZ:Yes. Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions.Install the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 assembly in compliance with the installation method listed in ALUM ssr.odf this report and applicable code sections of FBC. Refer to Created by Independent Third Party:Yes manufacturer's installation instructions. 17022.3 3-"1.5"Mechanical Seam"(115) 1.5"rib height, 16"wide,24 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.3 1.5 MECHANICAL Approved for use outside HVHZ:Yes seam 24ga ssr.odf Impact Resistant:No Verified By: Locke Bowden,P.E.49704 Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes Other:Refer to evaluation report for conditions and Evaluation Reports limitations of use.Install the assembly in compliance with FL17022 R7 AE FL 17022.3 1.5 MECHANICAL the installation method listed in this report and applicable seem 24ga ssr.pdf code sections of FBC.Refer to manufacturer's installation Created by Independent Third Party:Yes instructions. 17022.4 4-"1.5"Mechanical Seam"(115) 1.5"rib height, 16"wide,0.032"aluminum,standing seam roof panel mechanically attached to 15/32"plywood or Wood Deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.4 MECHANCIAL SEAM Approved for use outside HVHZ:Yes ALUMINUM ssr.odf Impact Resistant:No Verified By: Locke Bowden,P.E.49704 Design Pressure: +N/A/-Table A Created by Independent Third Party:Yes Other:Refer to evaluation report for conditions and Evaluation Reports limitations of use.Install the assembly in compliance with FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM the installation method listed in this report and applicable ALUMINUM ssr.pdf code sections of FBC.Refer to manufacturer's installation Created by Independent Third Party:Yes instructions. 17022.5 5-"1 in. Nail Strip"(115) 1"rib height, 16"wide,26 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.odf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.odf limitations of use.Install the assembly in compliance with Created by Independent Third Party:Yes the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.6 6-"1 in.Nail Strip"(115) 1"rib height, 16"wide,0.032"aluminum,standing seam roof panel mechanically attached to attached to 15/32" plywood or Wood Deck with fasteners, Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032 Approved for use outside HVHZ:Yes _ALUM ssr.Ddf Impact Resistant:No Verified By: Locke Bowden,P.E.49704 Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes Other:Refer to evaluation report for conditions and Evaluation Reports limitations of use.Install the assembly in compliance with FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032 the installation method listed in this report and applicable ALUM ssr.pdf code sections of FBC. Refer to manufacturer's installation Created by Independent Third Party:Yes instructions. 17022.7 7-"1.5 in. Nail Strip"(115) 1.5"rib height, 19"wide,26 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssr.pdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.0df limitations of use.Install the assembly in compliance with Created by Independent Third Party:Yes the installation method listed in this report and applicable code sections of FBC.Refer to manufacturer's installation instructions. 17022.8 8-"EMAX Rib"(115) 29 gauge steel,lapped roof panel mechanically attached to 15/32"plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 177022.8 EMAX Rib ssr.pdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 177022.8 EMAX Rib ssr.Ddf limitations of use.Install the assembly in compliance with Created by Independent Third Party:Yes the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.9 9-"PBR MAX"(115) 26 gauge steel,lapped roof panel mechanically attached to 15/32"plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.9 PBR RIB ssr.odf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other: Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.9 PBR RIB ssr.Ddf limitations of use.Install the assembly in compliance with Created by Independent Third Party:Yes the installation method listed in this report and applicable code sections of FBC.Refer to manufacturer's installation instructions. Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: z-z---j Credit Card Safe i • Report. i - 3tors LLC 2160 SW Poma Drive Palm City, FL 34990 772)872-8034 Florida Product Approvat# 17022.1 5- -V Crimp NON HiVHZ Compliant with Florida Building Code 2017 (6th ed.) ` Compliant with Florida Product Approval Rule#61G20-3 _ Compliant: Keystone Certifications s Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood Deck w/ min. 0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1 (Method 1 Attachment): #9 x 1-1/2" Hex-Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, &4 Attachment): #10 x 1-1/2" Hex-Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. See Fastener attachment specifications above Install Details: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4 DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF ROW SPACING 16"o.c. 16" o.c. 8"o.c. 6"o.c. FASTENER SPACING (ALONG Panel width) 12" o.c. 12"o.c. 12"o.c. 12"o.c. FASTENER SIZE 1 #9 #10 #10 #10 Reference Data: ARCHITECTURAL TESTING, INC.TST ID#: 1527 UL 580-06& 1897-041 Test Report X893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-1? *Design pressure margin of safety 2:1 C 0. 80L�..''% Locke Bowden,P.E.does not have,not will acquire a financial in U. qkm facturing or distributing products under this evaluation. " Locke Bowden,P.E.is not owned,operated,or controlled by a&coon paOornbbafaatureo,ordistributing products under this report. 9 • _� r �'�J STAT r:C4 f r • �� &/ a Ife '�..�+'0NAL I FL17022.1 5V Crimp (26GA Steel), 24" Wide Roof Panel - Details Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7.This report does not imply warranty, installation, recommended product use outside of this report. Fasteners- #9 x 1-1/2"Min. or #10 x 1-1/2"Min.per Table'A'for Row 5-V Crimp Roof Panel Spacing and Design Pressures Hex Washer Head Wood Screws Q 1�v Deck: 15/32"or greater Plywood,or Wood plank 24" 12" 73J13" OPTIONAL STRIATION.^-, Panel Profile Nominal 12" Nominal 12" D.C. O.C. Fasten k9 x 1-1/2"Min. or #10 x 1-1/2"Min.per -fable"A" Hex Washer Head Screw Spaced 12"o.c.across the Panel Width Panel Refer to Table"A"for Spacing Along Panel Overlap Length Deck-15/32"or greater Plywood,or -Wood plank