HomeMy WebLinkAboutProduct approvals i
i RECEIVED
FEB 16 2016
�►'�®T,aADE pER"dI TTI PIG MIAMI-DADS COUNTY
St.Lucie County, FL PRODUCT CONTROL SECTION
DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY 11805 SW 26 Street,Room 208
AFFAIRS(PERA)
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315L2599
NOTICE OF ACCEPTANCE OA w%vw.ml8,mldade:eov/building
Sun-Dome by Daylighting Technologies,Inc, ((��D ° 'I3612 Reese Avenue ST.LUC COUNTY BUILDING DIVISIO.
West Palm Beach,FL 33404 REVIEWED FOR C _
REVIEWED BY
SCOPE: DATE
P ANS PER T MU 'I'BE T O h'uc ton materials.
This NOA is being issued under the applicable rules & 010 %P1
The documentation submitted has been reviewed and accepte y tamr-Dade County PERA-Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ). i
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section(In Miami Dade County)and/or the A14J(in areas other than Miami Dade County)reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform
in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their'jurisdiction. PERA reserves the
right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this
product or material fails to meet the requirements of the applicable building code.
,%NCEAS FAS i EfiRS OR ATTAGR i S
This product is approved as described herein,and has been designed to:comp lyAvw{�th o.Ci��a�Bn' dUJnf,F,C;ode,
including the High Velocity Hurricane Zone. �p((� a U►� �cfLl l I r��I
DESCRIPTION: Sun-Dome Skylight CONTRAMB OF RECORD li
APPROVAL DOCUMENT: Drawing No. 1,titled"Sun-Dome/Tubular Skylight",prepared by Daylighting
Technologies Inc,dated 11/07/01,with last revision dated 12/05/11,sheet 1 of 1,signed and sealed by Terrence
Earl Lunn,P.E.,on 12/05/11 bearing the Miami-Dade County Product Control revision stamp with the Notice of
Acceptance number and the expiration date by the Miami-Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and the
following statement: "Miami-Dade County Product Control Approved or MDCPCA",unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product. {
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in
the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement oflany
product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,I hen
it shall be done in its entirety.
INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA#11-0817.13,and consists of this page 1,evidence submitted pages E-1 &c E-2,as,well
as approval document mentioned above.
The submitted documentation was reviewed by Helmy A.Makar,P.E.,M.S.
PRO POSED WORK IJ NOA No.11-1212
' CORRECTIONS Ex it
REQUIRED BY FIEIP INSPECTORS TPM o 1 fm Ao l , a at : 1
�.
MAYBE NECESSARY-IN ORDER TOP.: e
COMPLY WTH ALS APPLICABLE CODES..
i
Sun-Dome by Dayliehting Technologies,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#07-0917.03
A. DRAWINGS
1. Drawings prepared by Daylighting Technologies, Inc., titled "Sun-DomelTI bular
Skylight", Drawing Nal, Sheet I of 1, dated 11/07/01, with last revision dated
10122/07, signed and sealed by Terrence E. Lunn, P.E.
B. TESTS
1. Test reports on 1)Air Infiltration Test,per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test,per FBC, TAS 202-94
4)Large Missile Impact Test per FBC, TAS 201-94
S) Cyclic Wind Pressure Loadingper FBC, TAS 203-94
along with marked-up drawings and installation diagram of tubular dome,prepared
by Hurricane Test Laboratory, LLC, Test Report No. 0454-0903-06, dated 01/16/07,
signed and sealed by Viny J. Abraham, P.E.
C. CALCULATIONS
1. Anchor calculations letter issued T.E. Lunn, P.E., LLC, dated 10/30/07, signed and
sealed by Terrence E. Lunn, P.E.
D. QUALITY ASSURANCE
1. Miami Dade Building Code Compliance Office (BCCO).
E. MATERIAL CERTIFICATION
1. None.
F. STATEMENTS
1. Test Compliance letter issued by Hurricane Test Laboratory, LLC, issued on 01/16/07,
signed and sealed by Vinu J. Abraham, P.E.
2. Code compliance letter issued by T.E. Lunn, P.E., LLC, dated 10/30/07, signed and
sealed by Terrence R Lunn, P.E.
3. No financial interest letter issued by T.E. Lunn, P.E., LLC, dated 10/22/07, signed and
sealed by Terrence E. Lunn, P.E.
2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#11-0817.13
A. DRAWINGS
1. None.
elmy A.Makar,P.E.,M.S.
PERA,Product Control Unit Supervisor
NOA No.11-1212.04
Expiration Date: 12/15/11016
Approval DO—. . WA
E-1 .001 VA
i
I
i
i
Sun-Dome by Daylighting Technologies,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami-Dade County Building and Neighborhood Compliance Department(BNC).
E. MATERIAL CERTIFICATION
1. None.
F. STATEMENTS
1. Code compliance letter issued by T.E. Lunn, P.E., LLC, dated 07/29/11, signedand
sealed by Terrence E. Lunn, P.E.
2. Letter issued by T.E. Lunn, P.E., LLC, dated 07/29/11, signed and sealed by Terrence E.
Lunn, P.E., certify that he is still in the engineering business.
i
3. NEW EVIDENCE SUBMITTED
A: DRAWINGS
1. Drawing No. 1, titled "Sun-Dome/Tubular Skylight'; prepared by Daylighting Technologies
Inc, dated 11/07/01, with last revision dated 12/05/11, sheet 1 of 1, signed and sealed by
Terrence Earl Lunn, P.E., on 12/05/11.
B. TESTS
1. None.
I
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami-Dade County Department of Permitting, Environment, and Regulatory Affairs
(PERA).
E. MATERIAL CERTIFICATION
1. Addendum letter prepared by HTL, dated 12/05/11; signed and sealed by Finu J.
Abraham, P.E., stating the correct weather seal.
4� w
4ffeimy A.Makar,P.E.,M.S.
PERA,Product Control Unit Supervisor
NOA No. 11-126.04
Expiration Date: 1211 0
E-2 App, D@%:
i
PILE WEATHER SEAL POLYCARBONATE DOME (1/8" NOMINAL THK
(SCHLEGEL 0.36"x 0.26") VAC. FORMED) GE LEXAN XL-10 DADS CO.
APPROVED
RUBBER/5.5. WASHER DARK FOAM TUBE SEAL
DOME FASTENER-#8 x I"5TAINLE55
4 - RUBBER O-RING5 STEEL SCREW AT 9"O.C.
ROOFING DETAILS SHALL COMPLYWITH
CHAPTER 15 OF THE FLORIDA BUILDING ADJUSTABLE TOP TUBE
CODE. 4" MIN. CLEARANCE FROM DOME LIP
TO ROOF SURFACE FOR SHINGLE�BUR W!O
INSULATION. FOR IN5ULATION AND TILE
" 0.040 ALUMINUM ROOF FLASHING
ROOF: ADD THE TILE HEIGHT AND THE MIN. 4
INSULATION THICKNE55 TO 4". (ASHLEY-3105 ASTM 8209)
ROOFING SYSTEM
ROOF SHEATHING
RING SHANK FLASHING NAIL
7/1 G`O HD x 1-1/2" LG.
DESIGN PRESSURE j
RATING: +/- 100 F5
I
SUN-DOME CONNECTION DETAILS
APPROVED FOR USED IN
PRODUCTREVISM AND OUTSIDE HVHZ.
as complying with the Florida
Building Code
Acceptance No — O
2. Q ° ° ° ° o
hxpi tion Date=ctntrol
o j(y
&i D °
C # uXu
A ° g
RING SHANK NAIL I 1 GA.
x7116" HDx 1-112" L
° I
I
1-1/2"TYP.
B
ROOF FLASHING DIMENSIONS SUN-DOME DIMENSIONS
ROOF FLANGE DIMENSIONS DOME FOR BCCO USE
MODEL Y DIA. X RISE A B C FA5TENER5
21" 22" 9.5" 21.5" 29.0" 5 5PACE5 +J-G" 8
13" 14" G.75" 13.5" 23.5" 4 SPACE5 +/-5'1 5
10, JI- 6.0" 10.5 20.0" 3 5PACE5 +/-5-1 4
ENGINEERING �0 REV15ION: 10.22.07 ADDED REG NO. AND NAILING
2213 22nd LANs ������1C;,.E i��� 12-5-1 1 TO SCHLEGEL 5EWAL
PALM BEACH GARDENS,
FLORIDA 33418 �•��Q E F �`G'L TRODUCT
(561)62544M
H FL Reg.#26119 *: SUN-DOME / TUBULAR SKYLIGHT
SCALE: 12"= P-0" )JUMINUM CURB/PC DOME
DATE: 10/22/07'
CAD DWG FILE: .�o�Z;�r4t OF �AYLIGHTING TECHN 5
CHCKI;D BY: TEL ��i�`•''��O R`p Q'._'61 RIVIERA BEACH, FLDWN BY: TEL I F
.
- - - - - - -
FEB-- 1 ,6.2016 1 -
- - St 1 l
ucie Count� FL
Y
f
o
�I
4° _
_ lo� �` I.
FILE COP
'
I .
u
i
,i
2016.09.28 10:41 AMCORAp INC 5614392184 PAGE. 1/ 1
RSun-Dome by Daylighting Technologies,Inc.
3612 Reese Ave
SUNT SEP 2 8 2016 West Palm Reach,FL 33,404
info@sun-dome.com
PERIAITTING P. 561-840-0095
nrn,u,,u:PTINu'fhcnKui.uc:uM1lnr. St. Lucie county, FL F: 561-840-7606
I
NERC
COm liance esults j
Prime Series Sun-Dome: 10",13"and 21"sizes with Convex Diffuser j
TEST RESULT TESTING DATE TESTING LOCATION TEST TECH MIN.FOR ENERGY STAR
NFRC 102:U»Value 0.40 Startod: Intertok/ATI Ryan Moser Northern;<0,55
5/30/2016 x$0 Merry Court North-Central:<0.58
Completed: York,P 8auth centilah 5 0.5u
5/3'1/201G A 17406 Southum.,<.0.66
NFRC 201:SHGC 0.33 Started: IntertekATI
12/7/2015 / Jerry Northern:Any
2524 C Jensen Ave Bontilao North-Central: 0,3$
Completoch Fresno,CA y3706 South Central:-c0,20
12/14/2015 Southern;<0 28
NFRC 203:Visible started: Intertek/ATI Jerry
Transmittance Complutucl: 2524 E Jensen Ave Dontilao
Fresno,CA 93706
NFRC 400:Air Infiltration 0.13 Started;7/18/2016 Intertek/ATI Kyle Ruth 030
Completed; 130 Derry Court
7.26/2016 York,PA 17406
I
Prime Series Sun-Dome; 10",13"and 21"sizes without Convex Diffuser
TEST RESULT TESTING DATE TESTING LOCATION TEST TECH MIN,FOR ENERGY STAR
NFRC 102:U-Value 0.48 Started: Intertek/ATI Ryan Moser Northern:i 0.55
5/30/2016 x.30 Derry Court NocCli•Cattcrul:<0,58
cmrplotod; York,PA 17OG south Cont'rul:a 0.58
5/31/2016 Southern: 0.66
NFRC 201:SHGC 0,42 StarLod: Intertek/ATI Jerty Northern:Any
12/15/2015 2524-E Junsesn Ave Bontilao North-Contralc a 0.35
Complotod; Fresl�o,CA 93706 south Central:K 0.28
12/30/2015 Southern:<0.28
NFRC 203:Visible Started, Intertek/AT[ Jerry
Transmittance Complotodc 2524 E Jensen Ave Bontllao
Fresno,CA 43706
NFRC 400:Air Infiltration 0.25 Started:d/u%///2016 Intertek/ATI Kyle Ruth 0.30
Complet '130 Derry Court
York,PA 17406
O I
I
I
I
i
Results should be posted on the NFRC website within 60 days 8-12=2016
I
I
I