HomeMy WebLinkAboutBuilding Permit ApplicationAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: 1/21/2020 Permit Number:
,v wJ t�r ~
4.� — Building Ptrmit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential
PERMITTVPEVATER HEATER REPLACEMENT
POSED IMPROVEMENT LOCATIO.
Address: 11 NETTLES BLVD JENSEN BEACH FL 34957
Property Tax ID N: 4502-501-0197-000-8 Lot No.
Site Plan Name """' '""""`"°"'°""«'""""' Block No.
Project Name: LINDHOUT WATER HEATER
DETAILED DESCRIPTION:.OF W
,,. � - :�.
Replacing 30gal electric lowboy water heater in attic space in guest bedroom
INSTRUCTION INFORMATIO.-
Additional work to be performed under this permit —check all that apply:
_Mechanical _Gas Tank _Gas Piping _Shutters —Windows/Doom
_Electric X Plumbing _Sprinklers _Generator _Roof Pitch
Total Sq. Ft of Construction: Sq. Ft. of First Floor:
Cost of Construction:$ 2400.00 Utilities: _Sewer _Septic Building Height:
OW N ERALESSEE: ONTRACTOR:
NameSharon K Lindhout Name: MATTHEW BLACK
Address: 8335 SW Ridgestone DR Company: BENJAMIN FRANKLIN PLUMBING
City: Byron Center State: FL Address: 1631 SW SOUTH MACEDO BLVD
Zip Code: 49315 Fax: City: PORT ST LUCIE State: FL
Phone No.772-871-9494 Zip Code: 34984 Fax: 772-871-9069
E-Mail:PERMITS@BENFRANKLINPLUMBER.COM Phone No772-871-9494
Fill in fee simple Title Holder on next page (if different E-MailPERMITS@BENFRANKLINPLUMBER.COM
from the Owner listed above) State or County License
If value of construction is $2500 or more, a RECORDED Notice of Commencement is required.
H value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
DESIGNER/ENGINEER:
Name:
Not Applicable
MORTGAGE COMPANY:
Name:
x Not Applicable
Address:
Address:
City:
Zip: Phone
State:_
City:
Zip: Phone:
State:
FEE SIMPLE TITLE HOLDER:
Name:
A Not Applicable
BONDING COMPANY:
Name:
_;Not Applicable
Address:
Address:
City:
City:
Zip: Phone:
Zip: Phone:
OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the Issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in c.ntYlict with any applicable Home Owners Association rules, bylaws or antl covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessary uses to another non-residential use
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
TWICE FOR IMPROVEMENTS TO YOUq"OPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND
POSTED ON THE JOB SITE BEFORE TIfEF7R5T INSPECTION. IF YOU INTEND TO OBTAIN FINANCIMfpCONSULT
c yr avmmrn.cmrnr. -
Signature of Owner/ Lessee/Contractor as Agent for Owner Signature of Contractor/License Holder
STATE OF FLORIDA STATE OF FLORIDA
COUNTY OFST L. COUNTY OFsT wcie
The forgoing instrument was acknowledged before me
The forgoing instrument was acknowledged before me
this yRL day of tan 20�RC)by
this p&/day of _Na! .2020by
/);&, . ,R/oel
fik�, /31-dZ
Name of person making statement.
Name of person making statement.
Personally Known V OR Produced Identification _
Personally Known Z,� OR Produced Identification
Type of Identification
Type of Identification
Produced
Produced
No.
REVIEWS
N Haga
M502
PLANS
REVIEW
8R4DFA WHITE"
W A T E R H E A T E R S
J
t„N
Photo is of
RE240LN6
Residential Lowboy
Electric Water Heater
Copper Screw Type Immersion Element
QNCOLON pye im rsMW eemem avic b e yes request
Ineeek Immek „-�
The Lowboy ElecMc Models Feature.
■ Blanketed & Non -Blanketed Models Available —Non -Blanketed models
(RE1201-6, RE230LN6, RE240LN6, RE25011,16) help to decrease overall
installation time and are perfect for new construction applications. Blanketed
models (RE1301-6, RF2301.6, & RE24016) provide more Installation flexibility
and are ideal for replacement applications.
■ Low Restrictive Brass Drain Valve —Durable tamper proof design.
■ Fully Automatic Thermostat Controls —Fast acting surface -mount
thermostat with high limit energy cut-off (manual reset) for safety.
■ Direct Heat Transfer with Immersed Elements —Transfers heat directly
and efficiently to the water. Screw -in style.
■ Factory -Installed Hydrojete Total Performance System Sediment
reducing device that also increases first hour delivery of hot water while
minimizing temperature build-up in tank.
■ Vitraglas• Liningi exclusively engineered enamel formula that provides
superior tank protection from the highly corrosive effects of hot water. This
formula (Vitraglas' is fused to the steel surface by firing at a temperature of
over 1600°F (871 °C).
■ Insulation System—Non-CFC foam covers the sides and top of the tank,
reducing heat loss. This results in less energy consumption, improved
efficiencies, and jacket rigidity. Blanketed models additionally use a supplied
flexible fiberglass insulation blanket.
■ Water Connections—W (19mm) NPT factory -installed true dielectric fittings
extend water heater life and simplify water line connections.
■ Factory -Installed Heat Traps —Design incorporates a flexible disk that
reduces heat loss in piping and eliminates the potential for noise generation.
(Except for RE120L6).
■ Protective Magnesium Anode Rod —Provides added protection against
corrosion for long-term, trouble -free service.
■ Non -Simultaneous Operation —Nan -Simultaneous operation indicates only
one heating element will operate at a time and is standard construction from
the factory. Simultaneous Operation indicates both heating elements have the
potential to operate at the same time and is available as an option (must be
specified when ordering).
■ Voltages Avallable-120V, 208V, 240V, 277V, 480V.
■ Single Phase or Three Phase Operation Available-120V & 277V may
only be wired for single phase operation.
■ T&P Relief Valve —Installed, side T&P is standard. Optional top T&P location
is available.
■ Design evaluated by ETL in accordance with Part 280.707(rl) of HUD
Mobile Home Construction and Safety Standards for Energy Efficiency.
6 or 10-Year Limited Tank Warmn6es / 6 or 10-YearLimited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhke.com
For pwoocc Irsovedln USA, Cannv,, antl Puerto Riro. Some states tiv not allow IimRations on warrentles. See complete
coov of Yre warre pv inchioad with the heater.
12e3-0-1118
Residential Electric Water Heater
Lowboy Models
C.E.C. Listed
Mssl
Mutant
RrmwryN
A
8
C
0
E
G
Agra.
Mrstair
Gel.
BGE
ON Mae•
F,an,to
ads
Rash
CAN
fiowto
aid
Sly Inp
Cii iry
Raad
Hat
3q of
ola.
Water
WA,
TV
Coaa.
us
6knpe
Xoul
ban om
NeNer
Cone.
Com.
C.D.
XP3
U.S. Imp.
Volume
E.
9nR
U.S. Intoo.
Gal. Gal
(Gel4
(Calf
Rdar
GPN• EPN•
N.
IN.
IN.
in.
E.
in.
Is.
Roast
19 16AW
18
2Pla
is
25^lu
8
IM.125a1e
W
65
RE13GL8"
28 n
25
13
29 W,e
20
31Vi,
8
2YM1d31'l,.
N
99
R29LN6
28 H
9
10
294,e
23
31Wr
9
23r1,e131Lw
Vr
102
RE230L8"
20 x
25
18
29"1
22
31'Vn
8
2T4nI81Wn
Vr
19
AF210LN8
3y 31
34
18
Vhr
24'h
3411,r
8
23Va)MVa
Vr
IN
BR40LV
389
35
18
329r
24
34%
8
23-M1d34W,
w
1W
RE291H6
I5 31
43
IB
9rlu
�
96'In
8
2IVnl9V,a
VI
1T3
MWeI
Xmmlnel
ft.
A
8
0
E
S
Ammr.
Namcel
Lller
00F
60't Rlw•
Row10
4mMN
CAs
Rowla
Wakr
sAlr➢Im
CapaaiW
Rekp
Flat
iWN
01a.
Wakr
T&P
(onn.
WepAl
NIN,
Haul
U.N.
HBNaI
CON.
C.D.
XW
Volume
Ramp
assy'
LAeM
ditenf
Want
fads
Raw
NO.
mm.
DO.
as.
In.
RFIEOL
T2
9
821
WS
29
401I652
19
a
RE130i
IN
9
159
0RE
W
751
98
I
203
59A95
19
45
RMU16
IN
9
19
0.92
9
751
94
29
Wind
19
45
RF23,ILE—
I9
9
15S
ON
RJ
751
99
203
5291808
19
49
RROUI6
1W
in
171
0.9
N
814
622
20
591632
19
51
RE240LE"
144
132
19
0.91
9
H2
610
203
RE1819
19
m
FE291M6
ix
19
231
0.9
W
BW
fi9
x3
6181916
19
10
'Models ini supplied insulation blanket l2' thick).
Dimensions In charts above do not include blanket
thickness.
For 10 year models, change suffix "6" to "10".
Based on 45004/4601 Non -Simultaneous
operation.
All models available with optional top TBP location
(Plugged].
T Exempt from ASHRAE 90.1b (currant standard(.
Uniform Energy Factor and First Hour Rating is
based on the latest AHRI directory Ratings.
A(GPH based on NanSimultaneous
operation, when Simultaneous
operation the GPH will approximately
double.(
. = Not available on RE130L and
RE230LN6.
W
B
e•
o—
G �®
®[�[]O_
0,ei Mona
�a Cron (REt3GL6. RE230LNe.
RE240LN6, 8RF uhfa Doty)
•"E" dimension listed as side/top,
General:
Meete NAECA Requirements.
All models ETL listed. These heaters are wired inter-locong(Non-Simultaneous, Single Phase) 240V with two 450OW elements, unless otherwise specified.
All water and electrical connections are 3/4' (19mm) NPT. All models certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPe)
Dimensions and specifications subject to change without notice In accordance with our policy ofcantinuous poxhuct Improvement.
— aaa ro o For hold service. cemact your professbr,alimleller or local Bradford While sales represxmerte.
o a wxss,s— Styes 600523.2901 m F. 215-641.1612
AMERICAN BBAowRDkW m' T" 1111111 Technical Support 800.339-9398s Email techservpbratllortlwhita.com
STRONG- ranger, re Warranty IROIF631-2111 a Email wananty®brsdfordwhitacom
Intemefienal: Tdepham 1-215-M1-M m Email intemaSonalobmdforderhfie.com / www.wandfordwhiexone
Built to be the Best'-
1203-C-111B 0201 S. Bradford MR. Corporation. Al rights reserved Ptlnted In U.S.A