HomeMy WebLinkAboutWind Load Calculation Property Information F Building Information
Owner: Norm Fortier Wind Zone: 160 MPH.
Address: 19 Vera Cruz Exposure Category: B
Ft Pierce,FI 34951 Minimum Building Dimension: 30 ft.
Mean Roof Height: 15 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 End 53 55 7 31.0 -40.5
2 Int _53 55 7 31.0 -33.7
_............._ -.....................- ---................- ---........................._-----------------.._.........—--- .._...............-. -— ----..............._...
----
3 Int 53 55 7 31.0 -33.7
4 End 74 55 7 30.3 -39.1
5 Int 26 38 7 32.5 -35.2
6 Int 26 38 7 32.5 -35.2
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of 1