Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Wind Load Calculation
Property Information Building Information Owner: Cj &Norm Janelle Wind Zone: 160 MPH. Address: 21 Villa Blanca Exposure Category: B Ft Pierce,F134951 Minimum Building Dimension: 30 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone JL Width(in) Height(in) Elevation(ft) 11 Pressure(psf) Pressure(psf) 1 End 53 55 7 26.3 -34.4 .---..........--- -.._..- ....... ----..—.- -- ....._._.. _—___.._....—---.---_.._.._..--- -..................._...._.. —. _- -..._.. -.._._-......_.._._._...---.—_.._. 2 Int 27 47 7 27.6 -29.9 3 Int 27 47 7 27.6 -29.9 4 Int 74 63 7 25.5 -27.8 5 End 53 55 7 26.3 -34.4 ...............-._..._____—__......_......_.......____�_._......_..___._.._..... ..._.....-_....._.__._._ _. __......_.. 6 Int 53 55 7 26.3 -28.7 7 Int 37 55 7 27.0 -29.3 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1