HomeMy WebLinkAboutProduct Approvals "Product Report _ 2160 SW Portia Drive Palm City, Fl. 34990 772;)8724034, Florida Product Approval R ECEIVED i, Compliant with Florida Building Code 2017 (6" ed.) Compliant with Florida Product Approval Rule #61G20-3 1R� .2 3.1a1a I Compliant: Keystone Certifications Perm►ttme Depavtrne"t f St.Lucie County Ill'j Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2 7,,!90(,oq-51 Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood Deck w/0.42 specific gravity with 16" Cover OVED FOR 1 Rib Height 1" ��®� �® ������� Corrosion Resistant Compliant: FBC Sec. 1507.4.3 ST �p , �� Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penefr a ; % i .,IhTuy ® bottom of support. C c�o Adhesive/Sealant : Bostik 91571" Chem-Chalk one component, polyurethane adhesive with 3/16" continuous bead application along base of male rib vertical flange at each panel seam. 1 Underlayment: To be compliant with FBC Sec 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. CONT CT Install Details:- Table-A Allowable Loads__ METHOD 1.. _ ..,.,. . .M,ETHOD.:2 ...,,._,. ._:. i. DESIGN PRESSURE* -86 PSF Mainfield -97.25 PSF Perimeter FASTENER SPACING 6"O.C. 6"O.C. _ -- -- ------- .SEAM --SEAM ADHESIVE Not required3/16 can bead (see details) Reference Data: ARCHITECTURAL TESTING, INC.TST ID#: 1527 UL 580-06&UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen#1'&#2 'EQUIVALENCY:UL1897-04 isuivalent a ,to Test Standard UL1897-12. 4_ _ . ...:. . .,._Desi n.Pressure margin of safe ...,2.,1 Certificate of Independence: Locke Bowden,P.E.does not have,not will acquire a financial iripnattbhefflyeiompany manufacturing or distributing products under this evaluation. 5-- 1: Locke Bowden,P.E.is not owned,operated,or controllejpmR� dlanylocturer,or distributing products under this report. seal STATE OFslo •:l` �i a. I� I I i Limitations: 1.Underlayment to be compliance with current Florida Building Code(FBC)2017 6"'ed.. 2.Minimum slope to be compliant with Florida Building Code 2017 6"'ed.,and per with Manufacturer's installation reference. 3.Products are compliant for State of Florida product approval per Rule 61G20-3.Compliance Method:1-D 4.Engineering analysis for"project specific approval by local authorities wrJurisdiction is allowed by other registered engineers. 5.Fire classification is not part of this acceptance.Shear diaphragm values are outside this report. 6.Support framing in compliance w/FBC 2017 6t'ed.,Chapter 22 for Steel,Chapter 23 for Wood and Chapter 16 for Structural Loading. 7.This report does not imply warranty,installation,recommended product use outside of this report. FL 17022.5 1.0 Nail Strip(26GA Steel), 16"Wide Roof Panel -Details 16" 3/4�— Panel Profile 16" O.C. Deck: 15/32"or greater Plywood,or -Wood plank Integral Snap Lock I� For METHOD 2: Apply 3/16"Bead Bostik 915Tm Sealant Continuous Along Male Rib Vertical Flange Fastener #10 X 1"Min. per Table"A" Pancake Head Wood Screw (Typical Fastening Pattern Across Width) II 4 =f FL 17022.5 1.0 Nail Strip(26GA Steel), 16"Wide Roof Panel -Details Fastener #10 X 1"Min. per Table"A" Pancake Head Wood Screw 1"Nail Strip Roof Panel w Seam Adhesive Application: Deck: For Method 2 -15/32"or greater Plywood,or Apply 3116"Bead Bostik 915Tm Sealant -Wood plank Continuous Along Male Rib Vertical Flange (Refer to Table"A") Isometric View I'