HomeMy WebLinkAboutProduct Approvals BCIS Home { Log In User Registration Hot Topics Submit Surcharge ( Stats&Facts it Publications { FBC Staff I BCIS Site Map Links Search {
b
.'r Product Approval
{USER:Public User
r{Me.r�ra�
spr ,
fN'�s':.r91'aryum
Product Approval Menu>Product or Application Search>Application List>Application Detail
• a FL# FL17022-R7
Application Type Revision
Code Version 2017
Application Status Approved
Comments 08/18/2017v. date reapply 08/21/17
JAN
Archived 0
°SAN 2'2 20Ao Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive
Permitting DeP3Trllq.n Palm City, FL 34990
S
:
t.Luc' r., . �. 772 872-8034
flvalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidation@yahoo.com REVIEWED FOR
Technical Representative Richard McKuhen Oma®®E COMPLIANCE
Address/Phone/Email 2160 SW oma Dr'
Palm City,PFL 34990 ST. LUCIE COUNTY
(772)872-8034 �a
richard@emfab.net BOCC
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineee or Architect Name who developed the LOCKE BOWDEN
Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E.
WJ Validation Checklist-Hardcopy Received
Certificate of Independence FL17022 R7 COI FL 17022:1 5 V CRIMP ssr.pdf
Referenced Standard and Year(of Standard) Standard Year
TAS 125 2003
UL 1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
I
i
0
f
r
4
Product Approval Method Method 1 Option D
Date Submitted 08/18/2017
Date Validated 08/25/2017
Date Pending FBC Approval 08/28/2017
Date Approved 10/10/2017
Summary of Products
FL# Model,Number or Name Description
17022.1 1-"5V Crimp" (116) 26 Gauge steel,3/8"rib height, 24"wide lapped roof panel
mechanically attached to 15/32"plywood or Wood Deck with
fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other: Refer to evaluation report for conditions.Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.pdf
assembly in compliance with the installation method listed in Created by Independent Third Party:Yes
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.2 2-"5V Crimp"(R6) 0.032"Aluminum,3/8" Rib height,21"wide lapped roof panel,
mechanically attached to 15/32"plywood or Wood Deck with
exposed fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other: Refer to evaluation report for conditions.Install the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pdf
assembly in compliance with the installation method listed in Created by Independent Third Party:Yes
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.3 3-"1.5" Mechanical Seam"(115) 1.5"rib height, 16"wide,24 gauge steel,standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022.3 1.5 MECHANICAL
Approved for use outside HVHZ:Yes seam 24ga ssr.pdf
Impact Resistant: No Verified By: Locke Bowden,P.E.49704
Design Pressure: +N/A/-Table A Created by Independent Third Party:Yes
Other: Refer to evaluation report for conditions and Evaluation Reports
limitations of use. Install the assembly in compliance with the FL17022 R7 AE FL 17022.3 1.5 MECHANICAL
installation method listed in this report and applicable code seam 24ga ssr.pdf
sections of FBC. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
17022.4 4-"1.5" Mechanical Seam"(R5) 1.5"rib height, 16"wide,0.032"aluminum,standing seam
roof panel mechanically attached to 15/32"plywood or Wood
Deck with clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022.4 MECHANCIAL SEAM
Approved for use outside HVHZ:Yes ALUMINUM ssr.pdf
Impact Resistant: No Verified By: Locke Bowden, P.E.49704
Design Pressure: +N/A/-Table A Created by Independent Third Party:Yes
Other: Refer to evaluation report for conditions and Evaluation Reports
limitations of use.Install the assembly in compliance with the FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
installation method listed in this report and applicable code ALUMINUM ssr.pdf
sections of FBC. Refer to manufacturer's installation Created by Independent Third Party: Yes
instructions.
17022.5 5-"1 in. Nail Strip"(RS) 1"rib height, 16"wide,26 gauge steel,standing seam roof
panel mechanically attached to 15/32"plywood or wood deck
with fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other: Refer to evaluation report for conditions and
I
\
Oroduct Report
2160 SW Poma Drive
. I
Palm City, FL 34990
772)872-8034
-
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule#61G20-3
Compliant: Keystone Certifications
Product: -Crimp 26GA�Sfeel Roof Panel FBC;Sec. 1507:4:2
i Yield strength:.50 ksi min. ;Attached-to min 1S/
42"- Wood:-
"D ck w/ min.0.42 specific gravity with screws. 24" Coverage
--
Corroslon Resistant Compliant. FBC Sec. 1507.4.3 J
Fastener 1 (Method 1 Attachment):#9 x 1-1/2" Hex-Washer Head wood screw*to penetrate
3/16" min.thru deck or 5/8"embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, &4 Attachment):#10 x 1-1/2" Hex-Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
See Fastener attachment specifications above
;t .Install Details: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4
' DESIGN PRESSURE* - &PSF . : -93.5 PSF -101 PSF -228 PSF
. 120W SPACING 16"o c: 16"o.c. 8"O.C. 6"o.c.
-FASTENER'SPACING (ALONG--Panel width), -.12"o.c 12"o.c. 12"o.c. 12"o.c.
__
ENERSIZE _ _ 49.- �___; #10 #10 #10
FAST
Reference Data: ARCHITECTURAL TESTING,INC.TST ID#: 1527
UL 580-06& 1897-041 Test Report X893.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
-EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-1r t r r *Design pressure margin of safety 2.1
Locke Bowden,P.E.does not have,not will acquire a financial int 4�n Q+facturing or distributing products
under this evaluation. •�
Locke Bowden,P.E.is not owned,operated,or controlled by a&coarpar(#prnb%d attures,or distributing products under this
report. * :�
j�
` ANAL �•
I �
I
I �:
Y
Y
FL17022.1 5V Crimp (26GA Steel), 24" Wide Roof Panel - Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code(FBC)2017 61h ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7.This report does not imply warranty, installation, recommended product use outside of this report.
Fasteners-
#9 x 1-1/2°Min. or
#10 x 1-1/2 Min,perTab/e A'for Row 5-V Crimp Roof Panel
Spacing and Design Pressures
Hex Washer Head Wood Screws
rm
0
f
Deck:
15/32°or greater Plywood,or
Wood plank
24-
12'
318"
oPnoNAL STRA110W..,
Panel Profile
Nominal 12" Nominal 12"
O.C. O.C.
Fasten
Y9 x 1-1/2"Min. or #10 x 1-1/2"Min.per
Table"A" Hex Washer Head Screw
Spaced 12"o.c.across the Panel Width
Panel Refer to Table"A"for Spacing Along Panel
Overlap Length
Deck-15/32"or greater
Plywood,or
-Wood plank
e - a
BCIS Home Log In I User Registration Hot Topics I Submit Surcharge j Stats&Facts Publications j Contact Us BCIS Site Map I Links I Search I
Florida
Product Approval
USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
o - FL# FL16048-R6
a Application Type Revision
Code Version REeENFo 2017
Application Status Approved
2 �I11b
Comments Per",tt;r79 D -
Archived St. Lucia ep�Rrn,a '
Product Manufacturer Tri-Built Materials Group, LLC
Address/Phone/Email PO Box 70
Rutherford,NJ 07070
(800)516-1485
david.ruiz@tribuiltmg.com
Authorized Signature David Ruiz
david.ruiz@tribuiltmg.com REVIEWED FOR'
Technical Representative David Ruiz CODE COMPLIANCE PLIANC
Address/Phone/Email 250 Route 17 North
East Rutherford, NJ 07073ST° LU C I E 0"U N TY
(201)842-2449 ®
david.ruiz@tribuiltmaterialsgroup.com ®®CES¢�
Quality Assurance Representative
Address/Phone/Email
Category Roofing File Copy
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
O Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/18/2020
Validated By John W. Knezevich,PE
,i Validation Checklist-Hardcopy Received
Certificate of Independence FL16048 R6 COI 2017 01 COI Nieminen.pdf
li Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM G155 2005
FM 4474 2011
FRSA/TRI April 2012(04-12) 2012
UL1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
v
Product Approval Method Method 1 Option D
Date Submitted 09/25/2017
Date Validated 10/01/2017
Date Pending FBC Approval 10/03/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description
16048.1 TRI-BUILT Roof Underlayments Self-adhering,modified bitumen roof underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16048 R6 II 2017.09 FINAL ER TRI-
Approved for use outside HVHZ:Yes BUILT UNDERLAYMENTS FL16048-R6.pdf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-150 Created by Independent Third Party:Yes
Other: 1.)The design pressure noted herein pertains to use of Evaluation Reports
foam-on tile systems overtop the self-adhering underlayment FL16048 R6 AE 2017 09 FINAL ER TRI-
for one particular application.See ER Section 5.6.4 for details. BUILT UNDERLAYMENTS FL16048-R6.pdf
2.) Refer to ER Section 5 for other Limits of Use. Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Etatement::Accessibility Statement::Refund Statement
Under Florida taw,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
ECMck -aet
Credit Card
Safe
i
l [
EXTERIOR RESEARCH&DESIGN,LLC.
Certificate of Authorization 119503
` TRBN1-1YJER® 353 CHRISTIAN STREET,UNIT#13
OXFORD,CT 06478
- (203)262-9245
EVALUATION REPORT
TRI-BUILT Materials Group,LLC Evaluation Report A42960.10.12-116
PO Box 70FL16048-R6
Rutherford,NJ 07070 Date of Issuance:10/25/2012
(800)516-1485 Revision 6: 09/25/2017
SCOPE:
This Evaluation Report is issued under.Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
zDESCRIPTION: TRI-BUILT Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED'COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes;the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to.notify Robert Nieminen, P.E.-if the product
changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words,"Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall,be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1.through 6.
Prepared by:
1z X
y�o saa'gs'
Robert J.M.Nieminen,P.E. •,'r cs��v\?t The facsimile seal appearing was authorized hyRobert Nieminen,
�Ji..nunan
Florida Registration No.59166,Florida DCA ANE1983 P.E.on 09/25/2017.This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial'interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
�I
f �
►� TRINI-rY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: _ Underlayment'Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have
demonstrated compliance with the following sections of the 6t'Edition(2017)Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/
Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Resistance FM 4474 2011
1504.3.1 Wind Uplift UL 1897 2012
1504.6 Accelerated Weathering ASTM G155 2005
1507.2.4/1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015
1507.3.3 Physical Properties FRSA/TRI April 2012(04-12) 2012
3. REFERENCES:
kntfty Examination Reference Date
ERD(TST6049) Physical Properties 540540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties 540540.11.13 11/19/2013
ERD(TST6049) Physical Properties 540540.03.14 03/26/2014
ERD(TST6049) Physical Properties 544870.04.14-2 04/02/2014
ERD(TST6049) Physical Properties S44870.04.14-3 04/02/2014
ERD(TST6049) Physical Properties S44870.04.14-1 04/10/2014
ERD(TST6049) Physical Properties 544870.04.14-4 04/10/2014
ERD(TST6049) Physical Properties S43530.02.14-1-R1 05/14/2014
ERD(TST6049) Physical Properties S43530.05.14 05/28/2014
ERD(TST6049) Physical Properties 540540.10.14 10/31/2014
ERD(TST6049) Physical Properties SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SC8520.04.15 05/27/2015
ERD(TST6049) Wind Resistance SC14045.05.17-R1 06/07/2017
UL,LLC.(QUA9625) Quality Control Multiple-Listing R16814 12/10/2015
UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.07/18/2020
4. PRODUCT DESCRIPTION:
4.1 Tri-Built Sand-11 SA Shingle Underlayment is a self-adhering, glass-mat reinforced, sand-surfaced, SBS
modified bitumen roof underlayment,with a 36-inch sheet width;meets ASTM D1970.
4.2 Tri-Built S/A HT TU Underlayment is a self-adhering, non-woven polyester fabric surfaced, SBS modified
bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI April 2012.
4.3 Tri-Built Smooth AT S/A Underlayment is a self-adhering, glass-mat reinforced, film-surfaced, SBS
modified bitumen roof underlayment;meets ASTM D1970.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R6
Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-116
TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/2S/2017
Page 2 of 6
t
A
---
`f RINIIY J ER®
5.4 TRI-BUILT Roof Underlayments may be used with any, prepared roof cover where the product is
specifically referenced within,FBC approval documents. if not listed, a request may be made to the
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1:.ROOF COVER OPTIONS
Asphalt Wood Shakes
Underlayment Shingles Nail On Tile Foam-On Tile Metal &Shingles Slate
Tri-Built Sand=R SA Shingle
Underlayment Yes No No No, Yes Yes
Tri-Built S/A HT TU Yes
Underlayment Yes Yes See 5.5.1 Yes Yes Yes
Tri-Built Smooth HT S/A
Underlayment Yes"„ No No Yes , Yes
5.5.1 "Foam-On Tile"is limited to use of the following Appioved the adhesives/underlayment combinations.
TABLE 1A:ALLOWABLE TILE'ADHESIVE/UNDERLAYMENT COMBINATIONS)
Adhesive Florida Product Approval Underlayments
ICP Adhesives Polyset®AH-160 FL6332 Tri-Built S/A HT TU Underlayment
Dow TileBond- FL22525 Tri-Built S/A HT TO Underlayment'
5.6 Allowable Substrates:
5.6.1,' Direct-Bond to Deck:
Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41
primed Southern Yellow.Pine;ASTM D41 primed structural concrete.
While not required over plywood,OSB or Southern Yellow Pine substrates,TRI-BUILT Materials Group,LLC
recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note:
TRI-BUILT Materials`Group, LLC requires tongue-and-groove board decking be covered with plywood or
OSB prior to installation of the self-adhering Underlayment.
5.6.2 Bond-to-Insulation:
Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board.
.For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on tile systems. (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be
designed by a qualified design professional and installed based on testing of the insulation/underlayment .
system_in accordance with FM 4474,Appendix D or TAS 114,Appendix J.
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R6
Certificate of Authorization#9503 6'EDITION(2017)FBC ION-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017
Page 3 of 6
i
5.6.3 Bond to Mechanically Attached Base Laver:
Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ ASTM D226,Type I or II felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on the systems (Tri-Built S/A HT TU
Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012(04-
12).
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where
the underlayment forms part of the load-path. The following wind uplift limitations apply to direct-deck
underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12),Appendix A,Table 1A or
FBC 1609 for determination of design wind pressures.
#1 Maximum Design Pressure=-45.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional)ASTM D41 or RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered.
#2 Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Soprema Elastocol 600c
Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered.
#3 Maximum Design Pressure=-150.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove. dust and.debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp
splinters and wood projections shall be removed/sanded.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A HT TU Underlayment, self-adhered, shall be thoroughly roll using hand
roller and/or weighted roller to ensure there are no voids, and ensure there are no
voids/bridging at side and end-laps.
#4 Maximum Design Pressure=--60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)
and tin caps(FBC 1517.5.2)spaced 6-inch o.c.at the 4-inch laps and 6-inch o.c.in three,
equally spaced rows in the center of the sheet.
Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered.
Exterior Research and Design,.LLC. Evaluation Report A42960.10.12-116
Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017
Page 4 of 6
N
II� '
-,`-,j TR1N1- 1Y j ER®
5.6.4.1 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case,.Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional,to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPRI WD1, FM Losse Prevention Data Sheet 1=29 and Roofing
Application Standard RAS 117. Assemblies marked with'an asterisk* 'carry the limitations set forth in
Section 2.2.10:1 of FM Loss Prevention Data Sheet-1-29(January 2016)for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Tri-Built Sand-R SA Shingle Underlayment or Tri-Built.Smooth HT S/A•,Underlayment shall not be left
exposed for longer than 30-days after installation
Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12)):.
When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
TABLE 2:TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS'
Underlayment Tile Profile Staging Method Maximum
Slope
Flat Max.10-tile stack 6:12
Lugged Max.10-tile stack 5:12
Max.10-tile stack(bottom 2-tile stack
shall be inverted,followed by 8 tiles high 6:12
on slope,as shown below)
Tri-Built S/A HT TU r
Underlayment
Lugged
r
i
Exterior Research and Design,U.C. . Evaluation Repoit A42960.10.12-R6
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017
Page 5 of 6
i
I'
TRINrry(ER®
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC
published installation requirements subject to the Limitations set forth in Section 5 herein and the
specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Tri-Built Sand-It SA Shingle Underlayments Tri-Built S/A HT TIU Underlavment or Tri-Built Smooth HT S/A
Underlavment:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile applications:
While priming is optional,TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof
cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the
membrane tight. Firmly roll,broom or hand-press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below,sealed in accordance with
TRI-BUILT Materials Group,LLC requirements.
When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back-nailing in the
overlap area at the top of the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys,apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications(Tri-Built S/A HT TU Underlavment only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam-on tile applications,reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012(04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile
staging.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Gulfport,MS
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R6
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-116
TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017