HomeMy WebLinkAboutProduct Approval 6/5/2019 Florida Building Code Online
,,�; r'♦moi 'E`, Y' j, � r�`�. .
f },�
�.�°�n � 2 ErA .�, "f a• rz �� d A � � � ? -� a 9 �i� �-'Y•e'1;`'...11ir r _
db
BCrS HomeI Login User Registration i Hot Topics Submit Surcharge (ats&Facts 1 Publications Contact Us 80S Site Map i Links Search
EZ
a a
(j_�
du �
vo% Proct Approval /�))
r USER:Public User d"
Product Approval Menu>Product or Anpilcatlon Search>Agpiicatlon List>Application Detail &
FL# FL10674-R13
VN~ Application Type Revision
Code Version 2017
A
Application Status Approved
G�kv 0 �O
Comments 0o;Od
RVED ECEIArchived 11>
rn�
JAN.2 3,202#Product Manufacturer Owens Corning
Perrnittin Address/Phone/Email One Owens Coming Parkway
g DePai.trrlenr Toledo,OH 43659
St.Lucle County (740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keefer
greg.keeler@owenscoming.com
Technical Representative Met Sancrant
Address/Phone/Emall 1 Owens Corning PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
. Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J.M.Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W.Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 Ria COI 2017 01 COI Nieminen.�f
Referenced Standard and Year(of Standard) standard. YAM
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2011
Equivalence of Product Standards
Certified By,
Sections from the Code'
I '
https:llwww.florldabuilding.org/pr/pr_app dU.aspx7param=wGEVXQwtDgtbNbEY5V%2boOTa/o2b6w7ahReglCQ8ucR6ixEBFhs7tvJgzewa/o3da/o3d 1/2
6/6/2019 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 10/10/2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/15/2017
Date Approved 12/12/2017
Summary of Products
FL# Modelr Number or Name Description
10674.1 Owens Coming Asphalt Roofing 3-tab,4-tab, 5-tab,laminated,starter and hip&ridge shingles
Shingles and Starters
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10674 R13 Il 2017 10 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R13.pd
Impact Resistant:N/A Verified By: Robert J.M.Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party:Yes
Other:Refer to ER,Section 5. Evaluation Reports
FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT
SHINGLES FL10574-R13.odf
Created by Independent Third Party:Yes
EE
Contact Us::2601 Blair stone Road.Tallahassee FL 32399 phone:850-407-1624
The State of Florida is an AAtEEO employer.QmyIlght 2007-2013 State of Florida.::Privacy Statement::AccessibllityStatement::Refund staiernent
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 550.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalis
provided may be used for offkclal communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 4SS,F.S.,please click here.
Product Approval Accepts:
W] 150=78M Rig E
Credit Card
Safe
I � i
https:l/www.floridabuilding.org/pr/pr app U.aspx?param=wGEVXOwtDgtBNbEY5Va/a2boQTa/a2b6w7ahRogIC08ucR6ixEBFhs7tvJgZewa/o3d%3d 2/2
EXTERIOR RESEARCH&DESIGN,LLC.
ti Certificate of Authorization#9503
N STREET,UNIT#13
'\JITRINITY'ERD 353 CHRISTIAOXFORD,CT 06478
EVALUATION REPORT (203)262-9245
Owens Corning Evaluation Report 037940.02.12-R8
One Owens Corning Parkway . F1.10674-1113
Toledo,CH 43659 Date of Issuance:02/0612012
(740)4047829 Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the Wh Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FJBC I507.2.7.1/R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance,of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code-requirements with each Code Cycle.
ADvERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature, If any portion of the Evaluation Report Is displayed,then it shall be done in its entirety.
INSPEcTiow,Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages I through 8.
Prepared by:
tr
Robert J.M.Nieminen,P.E.
The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCA ANE1983 fi.is Nieminen,P.E.on 10/0912017.This does not serve as an
CERTIFICATION OF INDEPENDENCE' electronically signed document,
1. TrinitylERD does not have, nor does it intend to acquire or will It acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD Is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen,'P.E. are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,Is/was used for permitting or design guidance unless retained
specifically for that purpose,
-11__R[WrYJERD
ROOFING SYSTEMS EVALUATION:1ON:
1. SCOPE:
Product Category: Roofing
Sub•Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated
compliance with the following sections of the e Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2-7.1,R905.2.6.1 VAnd Resistance ASTM D7158 2011
3. REFERENCES-
Entity Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol,3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-132453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance IICA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical.Properties Classification letter 02/13/2014
UL ULC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation Exp,05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shinales:
4.1.1 Classic*and Supreme•are fiberglass reinforced,3•tab asphalt roof shingles.
4.1.2 Berkshire"are fiberglass'reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire"are fiberglass reinforced,S-tab asphalt roof shingles.
4.1.4 Duration, TruDefinitfon" Durationo, Duration" Premium Cool, TruDefinition' Duration• Designer Color
Collection, Tru Definition*oakridge'. Oakridgel' and WeatherGuard. HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip&Ridge Shingles:
4.2.1 Berkshire'Hip &Ridge Shingles, High Ridge,WeatherGuard• HP Hip& Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidgell Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. -LIMITATIONS:
5.1 This is a building code evaluation. Neither TrInjtVJ ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,Is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report Is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,U.C. Evaluation Report 037940,02.12-Rg
Cerr#7cate of Authorization#9503 6'"EDITION(2027)FEC NON-HVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
Page 2 of 6
i
TRIM-Ty IERC.
i
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable
for use in all wind zones up to Vasd = 150 mph (V„It = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for use in all wind zones up to Vasd=150 mph(V„It=194 mph). Refer to Section 6 for
installation requirements.to meet this wind rating.
5.4.3 Classification by ASTM D7159 applies to exposure category B or C,as defined in FBC 1609.4.3,and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlavment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3p 1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
> Berkshire shingles require minimum five(5)nails per shingle.
WeatherGuard*HP shingles require minimum six(6)nails per shingle.
Devonshire'shingles require minimum six(6)nails per shingle. l
> Starter Strip Shingle and Starter.Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be.in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or'11905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Fell underlayment Dock Fexarderbymsnt Deck SS
dkdbered
Sell•adherad 'ndedn'n1e"t
WeatherLock's .'
-. ��. underlayment Ddp�
Drip_ Drip edge Drip
edge edge
H �
looted
!' Nails located f+ r4'tromam
2=3"from eave
install first Self-sealing adhesive S"�p�padheswe i
Starter Strip Positioned along eave With 0,tams 8tr�iwa posWohedd°n9 e
shingle whit
6"removed Starter Strip shingle overhangs eaves and rakesstarters Flys°verhertgssavesIII drakesIM-21e-
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-Rg
Certi0cate of Authorization#9503 6TH EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 3 of B
i
I "
'ITYR?INFIERD
6.2.6 Minimum;Nailing—CEassk:6&Supreme: �
Nerrtlal Wnsard or Arse pars Narmai Mansard or Aran pets
VYled Areas High V{Mnd dnvanes y Mnd Areas High Vond do-
Aran pen viontos nomseies Arses vk+rttas tarartes Awa para viOntas normal" Ants- tiierstoe fuertes
Ir
6" ispoatWorydn 6618"Upoaon
BF�Kpositi6a
6.2.7 Minimum Nailing—Berkshire":
Sentant strip SaWant strip
btttadasr9adar La*adastgodor
�o- a t- -s s r--► s r---sa a«-----.*e----►a of e_t -.•
8Vz" 9v 9 Ya" 8th
a
a
e
Standard Fastening Pattern 6-Nail Fastening Pattern
Sea6rd strip
Le tvada saitadw
aw
1"
a
� Asphah roolingoatasnt
Cs0>anta da tarJwdo astatta
Mansard or Steep Slope Fastening Pattern
i
Exterior Research and Desigi,I.I.C. Evaluation Report 037940.02.12-R8
Certificate of Aothothottan 89503 6t"EDITION(2017)FBC NON-HVH2 EVALUATION FL10674 R13
Owens Coming Asphalt Roof Shingles Revision 8;10/09/2017
Page 4 of 8
E�C�
TRINITY
6.2.8 Minimum Nailing—Devonshire"";
17� _
..". Nails
5�18'e>tposuro SeelantlotaUon "` '
EllposlAinde5.W8pull; UbkW6ndel sellalot 1,• -- s•!
Ten 1"5 ots of Asphalt Roof Cement
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6. um Nailing — Duration®, TruDefinition® Duration, Duration® Premiu & TruDefinition'
Duration Designer Color Collection:
4-Nall Fastening Pattem ediall Fastening Pattern
SuieMaaAfasrinhq arse wWN sunvta3®rasunNp eleal.f W1
Mai,7yplem Malo TWCW
1 tr t^ tr �_ Ir A'
8•Lt"6dffi" �, _�1. 8.118.698" .r
Standard Fastening Pattern 6-Nail Fastening Pattern
Fa3lening for Slopes Greater Than 21:12
0ve1L8A1rbMng a".Ntllh
.adl,7ypk.1
tr I tr. r
:ra.vr
8.113'
•' r
ra"�-spoor awipe.a xmmp e.n,rt
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RB
Certificate ofAuthorizotion#9503 bT"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13
Owens Coming Asphalt Roof Shingles Revision S.10/09/2017
Page 5 of 8
I '
I
i
I
I� i
i
V
TRINITY, IERD
6.2.1 Minimum Nailing—TruDefinition"Oakridge®,Oakridge®:
4'Nall Patton 6 Nall Pattem
Esquoina eon 4:Navos Espema con 6 clavas
1 1
1^ r
6.618 B:posun Nam
6.619 Exposum y�
EkpostcrdndebblBptdg
MOW EYpaslaibt+de56/8PLO, 6518 6rpasu� - Cls� 56f8 Exposure
8�osted;n de56/b prdg. Ezpositim da 66/BpNg,
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Stopes Greater Than 21:12
5mvW10mmbigM wide,
' Itr0.rYp�
�^ �r IV
x
roe V Span afupbae ftaa"eanM .
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard®HP:
WbW
ii�Ueer7trw�Nil flit
..s.
EiYMrwLiw�rf�dir
' I
I
i
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8
Certif/cate of Authorization#9503 6'EDITION(2017)FBC NON^HVHZ EVALUATION F1.10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 6 of 8
fi
i
i .
I
J
� 1�9I`7`Y r ERD
6.3 Hip&Ridge Shinlales:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuardo HP Hip and Ridge Shingles
and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidgelm Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand-sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
t 4 F19.2
�— PnnrdtlnalRtnd TaPViau SldaVfaw
oaedros R.
'Nails Yl Nalk
4 I I z I Toptao5-08d
V Pla:tl
4 p r'
i I 1
A I I I I I
I 1 { 1
A �I
w r I
osure 1
i
I
I
6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge:
Fig.C Hip S Ridge Shingle Fastening
Fig.A P{�wtlNy Wum 4 4 TopVuw
�`-alroelbn A
Nulls�'"�—��-----�q A
A\ i� I NaHa Halls
1'ZV 2•,1'
�posun
---� s' Eapowro
Exterior Research and Design,LLC, Evaluation Report 037940.02.12=R6
Certgkate of Authorization#9503 GP EDITION(2017)FRC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 7of8
l ;
I
I I
PTRINIIY'�RD
6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Standard
Nn d^ Diinre tion Fastening
Seaiaitt Strip Pattern
W Expowre I �� � I•g
Fa:<an 71h' 7'h' 8"Expaaiae
Cover Exposed
Fastonm with
RoolCemant i•—1Z"---
6.3.6 Minimum Nailing—DuraRidgeT'"Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published'installation instructions for their minimum requirements.
pa�www oineeon Top vipin
ew
w—Dinrtlondrmlmntedivent r wvc�.parlor I-I
Dinodbn dd vi rim prodmliisnh
.n
cf—
�
C7IM F" I i
} t G
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(631)546-2458;Kanchi.Agrawala-Doka nia@ul.com
END OF EVALUATION REPORT-
Exterior
EPORT-
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RB
Certificate ofAathorkation49SO3 6T"EDITION(2017)FBG NON-HVHZ EVALUATION F1.10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 8 of 8
I •