HomeMy WebLinkAboutWind Load Calculation Florida Window & Door Co.1125 N.Dixie Hwy Tel.(561)848-4900 LLLake Worth,FL 33460 floridawindowanddoor.co ffing J
Property Information Building Information
Owner: Arthur Whitmarsh Wind Zone: 160 MPH.
Address: 2 Guava Lane Exposure Category: C
Port Saint Lucie,FL 34952 1 Minimum Building Dimension: 30 ft.
Mean Roof Height: 12 ft.
Risk Category: Id
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 End 37 56 7 32.7 -43.2
2 End 37 56 7 32.7 -43.2
3 End 72 80 7 30.5 -38.8
4 End 53 56 7 31.9 -41.7
5 End 53 56 7 31.9 -41.7
6 End 53 56 7 31.9 -41.7
r P Y
Prepared in accordance with:ASCE 7-]0,Chapter 30.Wind Loads-Components and Cladding.61h Edition(2017)Florida Building Code.