Loading...
HomeMy WebLinkAboutWind Load Calculation Florida Window & Door Co.1125 N.Dixie Hwy Tel.(561)848-4900 LLLake Worth,FL 33460 floridawindowanddoor.co ffing J Property Information Building Information Owner: Arthur Whitmarsh Wind Zone: 160 MPH. Address: 2 Guava Lane Exposure Category: C Port Saint Lucie,FL 34952 1 Minimum Building Dimension: 30 ft. Mean Roof Height: 12 ft. Risk Category: Id Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 End 37 56 7 32.7 -43.2 2 End 37 56 7 32.7 -43.2 3 End 72 80 7 30.5 -38.8 4 End 53 56 7 31.9 -41.7 5 End 53 56 7 31.9 -41.7 6 End 53 56 7 31.9 -41.7 r P Y Prepared in accordance with:ASCE 7-]0,Chapter 30.Wind Loads-Components and Cladding.61h Edition(2017)Florida Building Code. Page 1 of 1