HomeMy WebLinkAboutWind Load Calculation Florida Window & Door Co.
fZ�G�;�i;�tyD
1125 N.Dixie Hwy
Tel.(561)848-4900 JAN 2 3 2020
Lake Worth,FL 33460 floridawindowanddo r'F-rl
ucie County, Permitting
Property Information Buildin Information
Owner: Randall Hirschfeld Wind Zone: 160 MPH.
Address: 5000 Fort Pierce Blvd Exposure Category: C
Fort Pierce,FL 34951 Minimum Building Dimension: 30 ft.
Mean Roof Height: 12 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) IF Pressure(psf) Pressure(psf)
1 End 37 80 7 31.9 -41.7
2 End 37 63 7 32.4 -42.7
3 End 37 63 7 32.4 -42.7
4 End 37 63 7 32.4 -42.7
5 End 37 63 7 32.4 -42.7
6 End 37 38 7 33.5 -44.8
7 End 70 80 7 30.5 -38.9
8 End 37 38 7 33.5 -44.8
9 . End 90 63 7 30.5 -38.9
F m-'I LEEw C
0 P Y
Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(1017)Florida Building Code.
Page 1 of 1