HomeMy WebLinkAboutArchitect letter ASSOCIATE Inc. M.A. COI�SOl�T & SS ARCHITECTURE * STRUCTURAL DESIGN 412 Colorado Ave., Stuart,Fl. 34994 (772) 223-8227 * Lic. #AR91665 SFr A Date: January 09, 20202�1�o ��90 R CSP P,O To: St. Lucie County - Building&Code Regulation Division Re: Kimberly Johnson 9940 S. Ocean Drive Unit 1105 (Middle) Jensen Beach,Fl. , 34957 It is acceptable to replace existing sliding glass door& single hung window openings for the address listed above with these units as follows: 1) S.G.D -The International Bldg. Products L.L.C. Series "Titan 90" Alum. L.M.I. sliding glass door has a Florida number NOA- #18-0412.01. It has a+90/-90 design pressure and has a large missile "D" approval and HVHZ . 2) S.H. -The PGT Systems Inc. Series "SH 7700A" L.M.I. alum. single hung window has a Florida number NOA-#18-0430.06. The nominalwind speed is 132 mph and the 'I ultimate wind speed is 170 mph. It has a+80/-110 design pressure and has a large missile "D" approval and HVHZ . The actual building design pressures of address listed above in Zone 4 is+58.7/-63.7 The building has a type II classification and exposure category "D" for the 6th Edition of the FBC (2017). Worst case scenario has been calculated . Thank you for your time and consideration. If you have any questions please call. Respectfully, I M A.,=Orson A.I.A.,NCARB P"resident' - - I ',