HomeMy WebLinkAboutMisc letter, architecture letter a M.A. CORSON & ASSOCIATES, Inc. ARCHITECTURE * STRUCTURAL DESIGN 412 Colorado Ave., Stuart, Fl. 34994 (772) 223-8227 * Lic. #AR91665 9-0-C t Date: January 09, 2020 anme� To: St. Lucie County -Building& Code Regulation Division `�9°e jWC1 PQ<5C Labe Re: Kathleen Viola 9900 S. Ocean Drive,Unit 209 (middle) Jensen Beach,Fl. , 34957 It is acceptable to replace existing sliding glass door opening for the address listed above as follows: 1) S.G.D -The PGT Window Systems "SH 7700A" Impact alum. sliding glass door has a Florida number NOA# 17-0420.12. The nominal wind speed is 132 mph and the ultimate wind speed is 170 mph. It has a+90/-90 design pressure and has a small missile "D" approval and HVHZ. The actual building design pressures of address listed above in Zone 44 -is +58.7/-63.7. The building has a type II classification and exposure category "D" for the 6th Edition of the FBC (2017). Worst case scenario has been calculated . I Thank you for your time and consideration. If you have any questions please call. Respectfully, Mark A._Corson.WA. CARB Presiderif 1 LE �®pY