HomeMy WebLinkAboutNotice of Acceptance i
Miami-Dade County Building
RECEIVE®
Product Information for N.O.A. 17-1023.19
JAN 2 4 aM
Sf, Lucie County, Perrnitting
N OA 17-1023.19 I I_(library_/p roductcontrol/noa/17102319.pdf)
Superseded_By
File Status File Approved
File Classification High velocity hurricane zone
Category Roof
Subcategory Skylights- Units
Material Polycarbonate
Applicant Sun-Tek Manufacturing, Inc. (pc-result detail app.asp?app alias=101593)
Expiration—Date January/10/2021
Impact Rate Large and Small Missile Impact
Maximum_Design_Pressure_Positive 60
Maximum_Design_Pressure_Negative 60
Description Hurricane Self Flashing (HSF)Aluminum Skylight
Green—Sustainable—Attributes NONE
For a detailed description on the File Status, click the NOA File Status Key..(/building/pc-result key app.asp)
Page Last Edited: Wed Jan 25, 2017 10:40:27 AM
MIAMI.OWDE
COO
•b ��
MIAMI•DADE MIAMI-DADS COUNTY
o PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.aov/economy
Sun-Tek Manufacturing,Inc.
10303 General Drive
Orlando,FL 32824
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority '
Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County) reserve the right
to have this product or,material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may i
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER
reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
i
This product is approved as described herein,and has been designed to comply with the High Velocity
Hurricane Zone of the Florida Building Code.
DESCRIPTION:Hurricane Self Flashing(HSF)Aluminum Skylight !
APPROVAL DOCUMENT:Drawing No. HSF-002,titled"HSF",sheets 1 and 2 of 2,dated 01/27/2001,
prepared by Sun-Tek Manufacturing,Inc.,signed and sealed by James D. Wells,Jr.,P.E.,on October 06,
2017,bearing the Miami-Dade County Product Control revision stamp with the Notice of Acceptance number
and the expiration date by the Miami-Dade County Product Control Section.
MISSILE IMPACT RATING:Large and Small Missile Impact Resistant
LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city, state,
model/series and following statement: "Miami-Dade County Product Control Approved",unless otherwise
noted herein.
t
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of
any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to
comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then
it shall be done in its entirety.
INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
1
This NOA revises NOA#15-0513.07 and consists of this page 1 and evidence submitted pages E-1&E-2
as well as approval document mentioned above. 1
The submitted documentation was reviewed by H Imy A.Makar,P.E.,M.S.
NOA No.17-1023.19
MIAMIDADE COUNTY 11/ Expiration Date: 01/10/2021
...... Approval Date:02/22/2018
o2/ZZJ2.0/� Page 1
1
Sun-Tek Manufacturing,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No.HSF-002,titled"HSF", sheets land 2 of 2,dated 01/27/2001,with revision
dated 12/15/2010,prepared by Sun-Tek Manufacturing,Inc., signed and scaled by James D.
Wells,Jr.,P.E.
B. TESTS "Submitted under NOA #11-0104-09"
1. Test reports on 1)Air Infiltration Test,per FBC,TAS 202-94
2)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94
3)Water Resistance Test,per FBC,TAS 202-94
4)Large Missile Impact Test per FBC,TAS 201-94
5)Cyclic Wind Pressure Loading per FBC,TAS 203-94
6)Forced Entry Test,per FBC 24113.2.1,TAS 202-94
along with marked-up drawings and installation diagram of HSF Polycarbonate Aluminum
Fixed Skylights,.prepared by National Certified Testing Laboratories,Test Reports No.210-
3716-1,dated 11/22/2010,with a revision dated 03/07/2010, signed and sealed by Gerard J.
Ferrara,P.E.
C. CALCULATIONS "Submitted under NOA #11-0104-09"
1. Anchor calculations prepared by J&L Wells Consulting LLC,dated 01/04/2011,signed and
sealed by James D.Wells,Jr.,P.E.
D. QUALITY ASSURANCE
1. Miami-Dade Department of Permitting,Environment,and Regulatory Affairs(PERA)
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 12-0110.04 issued to Palram Americas,Inc.for their"Corrugated
and Flat Polycarbonate Panels",approved on 02/23/2012 and expiring on 01/22/2016.
2. Notice of Acceptance No. 08-0305.02 issued to SABIC Innovative Plastics for their"Lexan
Sheet Products"approved on 04/24/2008 and expiring on 07/17/2013.
3. Notice of Acceptance No. 10-0329.03 issued to Sheffield Plastics,Inc.,for their"Makrolon
Polycarbonate Sheets"approved on 07/07/2010 and expiring on 08/27/2012.
F. STATEMENTS
1. Statement letter of code conformance to 2010 FBC issued by J&L Wells Consulting LLC,
dated 04125/2012, signed and sealed by James D.Wells,Jr.,P.E.
"Submitted under NOA #11-0104-09"
2. Statement letter of code conformance with FBC 2007 and no financial interest issued by J&L
Wells Consulting LLC,dated 03/17/2011,signed and sealed by James D. Wells,Jr.,P.E. j
I
i
my A.Makar,P.E.,M.S.
Product Control Section Supervisor
NOA No.17-1023.19
Expiration Date:01/10/2021 i
Approval Date:02/22/2018 3
i
E4
1
1
Sun-Tek Manufacturing,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#15-0513.07
A. DRAWINGS
1. Drawing No. HSF-002, titled "HSF", sheets 1 and 2 of 2, dated 01/27/2001, with
revision dated 05/04/2015,prepared by Sun-Tek Manufacturing, Inc., signed and
sealed by James D. Wells, Jr., P.E.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami-Dade County, Regulatory and Economic Resources Department(RER).
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of code conformance to 2014 FBC issued by J&L Wells Consulting LLC,
dated 05105/2015, signed and sealed by James D. Wells, Jr., P.E.
3. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. HSF-002, titled "HSF", sheets 1 and 2 of 2, dated 01/27/2001,prepared
by Sun-Tek Manufacturing, Inc., signed and sealed by James D. Wells, Jr., P.E., on
October 06, 2017.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami-Dade County, Regulatory and Economic Resources Department(RER).
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of code conformance to 2017 FBC issued by J&L Wells Consulting LLC,
dated 10/06/2017,signed and sealed by James D. Wells, Jr.,P.E.
elmy A.Makar,P.E.,M.S.
Product Control Section Supervisor
NOA No. 17-1023.19
Expiration Date: 01/10/2021
Approval Date: 02/22/2018
E-2
1��1,�l1I EAlQ!/pI
�IWNID ib�l IIr
Engineer of Record: J&L Wells Consulting LLC �l �
James D.Wells,Jr.,P.E. 1453 Arbitus Circle 1%,
Professional Engineer No.53616 Oviedo,Fl,32765 1
(407)496-5489
Certificate of A uthariaation No.27162 ;Lo t�
OF
PART NAME: ISHEET 1 OF 2
DRAWN BY: L.B.REED 1 DWp.R:HSF 002
{Palrarn Palsun,SO b cE exxann 9034 orSHPOLYCARBONATE
d Makrol n) SILCON{CONT NC IU ),!l!11100
DECO CLIP,060
6063 T-6 ALUMNIUM INSULATED AIR SPACE E LF- HEAD
STI-217 DRILLING
8 PER SIDE
DECO RING.050
6063 T-5
ALUMNIUM STI-208
BUTYL SEALING TAPE INNER DOME.080
(CONTINOUS) POLYCARBONATE(Pa1rarn Palsun, FRAME.080
Sabic Lexan 9034 or Sheffield Makrclon)) 6063 T-6 ALUMNIUM
IL
STI-207 W tJ r M
CORNERS MITERED z R
INSULATION OR AND WELDED ren t j
DESIGN PRESSURE RATING AIR SPACE E5 a
+-60 PSF LL
LARGE MISSILE IMPACT RESISTANCE PVC LINER PRODUCT REVISED ��
STI-300 as complying with she Flor;dz: Z U)
STS 1000 SEALANT COMPLY WITH SECTION 2613 l3teildirtE Cade 0
CONTINOUS UNDER FRAME Acceltaartae lei 17- O�3.J
AROUND PERIMETER OF THE F.B.C. Exp' 'onDate
OVER HEADS OF SCREWS j
NOTE: By
(1)ALL ROOF DETAILS SHALL COMPLY WITH 1wt coravol
CHAPTER 15 OF THE 2017 FLORIDA BUILDING
CODE.
51- (2)4"MINIMUM DISTANCE FROM ANGLE LIP TO
ROOF SURFACE FOR SHINGLES OR B,U,R.
WITHOUT INSULATION.FOR INSULATION
Dom„ AND TILE ROOF ADD TILE HEIGHT AND
INSULATION THICKNESS TO THE 4"MINIMUM
HEIGHT. #8 X 1"PHILLIPS PAN HEAD
TIHROUGFiROOFDECK :ROOF DECK MIN 8 PER SIDE
a"THICKNESS
REVISION: REMSION; PRODUCT NAME;
u SUN-TEK MANUFACTURING, INC.
1NI; '215.10 wh DATE-01/27/01` t SCALE: tMr,No. HSF-002 10303GENERAL DRIVE ORLANDO.FI.32824
X
I&L Wells C011SUILing 11C
1.453 Arbitus Circle
Engineer of Record: Oviedo,FL 32765
James D.Wells,Jr.,P.E. (407)496-5489 53
Professional Engineer No.53616 Certificate of Authorization No.27162: t
9 QE
PART NAME: PLAN VIEW HSF 2 CII.T< A-.
I DRAWN BY: L.B.REED ---------- F-002
54.50 NOTE, V/;/ KA
400 (1)ALL ROOF DETAILS SHALL COMP64U wth I I%
675 CHAPTER 15 OF THE 2017 FLORIDA BUILDING
6.75 CODE,
4.00 MIM.
6.75 0 C) (2)4"MINIMUM DISTANCE FROM ANGLE LIP TO
0.63-- — ROOF SURFACE FOR SHINGLES OR 8.U.R. LIPTO
.001 ROOF
WITHOUT INSULATION.FOR INSULATION
AND TILE ROOF ADD TILE HEIGHT AND SURFACE
T EIGHT-
POLYCARBONATE DOME.093 THICK
32 FASTENERS FRAME TO DECK (PaIrarn Paisun,Sheffleld Makrolon or Sa4ic Lexan 9034))
cv
U?
C> U HSF 4646 POLYCARBONATE DOME,OBD THICK
(Du
It (D (PaIram PaIsun,Sheffield Makrolon or Sabic Lexan 9034)
U)(D
Q0 SYMETERICAL
32 FASTENERS D CO RING TO FRANE DESIGN PRESSURE RATING
60 PSIF
#—ELARGE MISSLE IMPACT RESISTANCE
PRODUCT RE,VISE D
FASTENER SCHEDULE FRAME TO DECK FASTENER SCHEDULE DECO RING TO FRAME as cOmPlYing'Aidl 1110 floxi0v,
#8 X 1 PHILLIPS PAN HEAD SCREWS 46 X 3/4 HEX HEAD SELF DRILLING SCREWS Building Code
MODEL PER LONG SIDE PER SHORT SIDE MODEL PER LONG SIDE PER SHORT SIDE ACceptMceN0Lj—j 0 Z'3.
ExpiqVion Dro—
4646 8 8 4646 8 8 Soj
74:V--ZO
3046 8 6 3046 8 6 By
366— 7 7 3636 7 7
2246 8 52246 8 5
.2222 5 5 12222 5 5
REVISION. REVISION: SUN-TEK 10303 GENERAL DRIVE
—1K 1141: INDUSTRIES, INC.
IL)AlE; 3F ORLANDO,FL 32824
1SCALE: I DWG No. HSF-002
.................