Loading...
HomeMy WebLinkAboutProduct Approval (2) •1'S -._. .,.rv.d.i.-vl..--�.�_e•...._..G yf.'-.i.:Jl�c-.+v=:+'_..�+.i��w+n.ri3 C.'.� ...r�'•ti.So,a.x_. r.l:''N!L4-yh-.-f<"'��ri'..-_.J._'j�:`at=:R����1'�� .F.i�°�h'K^'h!?G BW Home 1=_][n User Registration ro:Tc�Olcs Submit Surcharge StatsaL Fars PubBtaftm tan=Us BGrS Site Map unks Search Product Approval x USER:Public User *-.v.'t=A'•-•. Si Mena> -a'c•;c cr s==-cadx+S_2zr=> L�>AppfiCation Detail FL FL2569-1116 Application Type Revision Code Version 2017 RECEIVED Application Status Approved JAN 2 3 2020 Comments Archived ST. Lucie County, Permitting Product Manufacturer Soprema,Inc.(Canada) Address/Phone/Email 1640 rue Haggarty Drummondville,NON-US 00000 (819)478-2400 memathieu@soprema.ca Authorized Signature Marc-Etienne Mathieu memathieu@soprema.ca REVNEWED FOR Technical Representative Marc-Etienne Mathieu C�®ECJ s®7 MPWn/'�f,�FlCE Address/Phone/Email, 1688 Jean-Berchmans-Mictrau L=�li Z7 Drummondville,NON-US Oo�� L U D U E COUNTY (819)478-2400 Ext 3327 tf memathieu@soprema.ca BOCC Quality Assurance Representative Jean-Francois Cote,Ph.D. Address/Phone/Email 1640 rue Haggarty Drummondville 7�8)811-314S e@soprema.ca .dt'He copy Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Praltssional Engineer lEaaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert J.M.Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 07/18/2020 Validated By J61 n W.Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL2569 R_6 Cp: 2019 01 Cpl NIEMiNEN odf Referenced Standard and Year(of Standard) Standard year ASTM D1970 2015 ASTM D4798 2011 ASTM D6163 - 2008 FM 4474 2011 FRSA/TRI April 2012(04-12) 2012 UL 1897 2012 Equivalence of Product Standards Certified By Sections from the Code . - Date Submitted 05/28/2019 Date Validated 06/05/2019 Date Pending,FBC Approval 06/10/2019 Date Approved 08/13/2019 Date Revised 08/14/2019 Summary of Products f FL S Mode[,Number or Name i Descrlptlon 2569.1 j Soprema Roof Self adhering roof underiayments I Undedayments i €Limits of Use F Installation Instructions Approved for use in HVHZ:No FL2559 P16 H 2019 05 FINAL ER SOPREMA CA LJHDERd livML-;V'+S =22569- ; Approved for use outside HVHZ:Yes I R!6. Impact Resistant:N/A Verified By: Robert Nieminen,P.E.PE-59166 Design Pressure:+N/A/-150 Created by Independent Third Party:Yes I Other.1.)Refer to ER Section 5 for limits of 1 Evaluation Reports Use.2.)The design pressure noted herein FL2569 R25 AE 20=9 05 FINAL ER SOPREFFI . CA UNDE2LAYMST17S F-1.256,9- pertains to underlayment systems used RI6.7>dn t beneath adhesive-set tile systems. Refer to Created by Independent Third Party:Yes ER Section 5.6.4 for details. i I Contact Us::2601 Blair Stone Road,Tallahassee R.32399 Phone:8.50-487-1824 The State of Florida is an AA/EEO employer,Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a pubic-records request,do not send electronic mal to this entity.Instead,contact the office by phone or by traditional-mail.If you have any questions,please contact 850.487.1395.'Pursuantto Section 402755(1). Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must;provlde the.Department with awemail 0ddressM they have one.The emaiis provided may be used for official communication with the licensee.Howeveremal addressesarepubUc record.If you do not wish to supply a personal address,please provide the Department with an.emal address which can be made available to the public To determine if you are a licensee under Chapter 455,FS.,please dirk her . ' Pr�oProduct Approval Accepts: Credit Card Safe . I 3 Certificate of Authorization#32455 353 Christian Street,Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALIJATLON .e• Soprema,Inc. Evaluation Report 518010.06.09-1114 1640 rue Haggerty FI-2569-1116 Drummondville,Quebec J2C SP8 Canada Date of Issuance:06/15/2009 (819)478-2400 Revision 14:05/28/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The.documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products described herein have been evaluated for compliance with the 61'Edition(2017)Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.of any changes to the product(s),the Quality Assurance or the production facility location(s). MEMO I etc.requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded by the words "NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. j Prepared by: ,t.,.,.,,,,_— r^ jam.. Robert J.M.Nieminen P.E. 3 =`' The facsimile seal appearing was authorized by Robert Florida Registration No.59166,Florida DCA ANE1983 Nieminen,P.E.on 05/28/2019.This does not serve as an electronically signed document. CmmFicATIoN OF INDEPENDENCE: 1. NEMO ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product 5. This is a building code evaluation. Neither NEMO 1 etc,nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. I . j ONEMOJetc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments,as produced by Soprema, have demonstrated compliance with the following sections of the 61'Edition(2017)Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth herein. 091-11-r Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.1.1,1507.2.9.2,R905.1.1, Physical Properties ASTM D1970 2015 R905.2.8.2 1507.3.3,R905.3.3 Physical Properties FRSA/TRI April 2012 2012 FRSA/TRI April 2012(04-12) Physical Properties ASTM D6163 2008 TAS 110 Accelerated Weathering ASTM D4798 2011 3. a Enti Examination Reference Date ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD(TST6049) ASTM D1970/TAS 110(QC) 531370.03.10-1-R1 04/07/2010 ERD(TST6049) FRSA/TRI 04-12(OH) 511150.05.09-112 10/05/2010 'ERD(TST6049) ASTM D1970(OH) 537210.11.11 11/09/2011 ERD(TST6049) ASTM D1970(MS) S37210.12.11 12/01/2011 ERD-(TST6049) ASTM D1970(MS) 540540.02.13-1 02/19/2013 ERD(TST6049) FRSA/TRI 04-12(MS) 543530.02.14-1-R1 02/21/2014 ERD(TST6049) ASTM D1970(13C) 544870.04.14-2 04/02/2014 ERD(TST6049) ASTM D1970(QC) 544870.04.14-3 04/02/2014 ERD(TST6049) ASTM D1970(OH) 544870.04.14-1 04/10/2014' ERD(TST6049) ASTM D1970(MS) 544870.04.14-4 04/10/2014 ERD(TST6049) ASTM D1970(OH) 540540.10.14 10/31/2014 ERD(TST6049) Tensile Adhesion/Long Term Aging SOPC-SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015 ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017 M-D(CER1592) HVHZ Compliance 18-0329.03 06/28/2018 ICC-ES(EVL2396) 20151BC Compliance ESR-1524 03/01/2017 NEMO(TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-R1 04/25/2018 MEMO(TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018 PRI(TST5878) ASTM D1970(MS) SOP-064-02-01 12/03/2013 Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL,LLC(QUA9625) Quality Control MLA File No.R27605 05/08/2019 UL,LLC(QUA9625) Quality Control Service Confirmation 07/18/2017 Product Specification Plant(s) Description 4.1 Lastobond TU HT ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric surfaced, FRSA/TRI April 2013 SBS modified bitumen roof underlayment 4.2 Lastobond Shield ASTM D1970 ' Drummondville,QC self-adhering,woven polyethylene surfaced,SBS modified bitumen roof underlayment available in two widths;36 and 45 inch NEMO ETC,LLC Evaluation Report S18010.06.09-1114 Certficate ofAvthorizotion#32455 6T'EDi BION(2017),-BC NON-MV13Z EVALU.'MON FM69-1116 Soprema Roof Underlayments Revision 14:05/28/2019 Page 2 of 8 i NFM®J etc. Product Specification Plant(s) Description 4.3 RESISTO SA SMOOTH PLY ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS 40 modified bitumen roof underlayment 4.4 Lastobond Shield HT ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high temperature,SBS modified bitumen roof underlayment 4.5 Lastobond Pro HT-N ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS modified bitumen roof underlayment available in two widths;36 and 45 inch 4.6 Lastobond Pro HT-S ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high temperature,SBS modified bitumen roof underlayment 4.7 EnviroShield: ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high temperature,SBS modified bitumen roof underlayment 4.8 Lastobond 195 ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-surfaced, Wadsworth,OH SBS modified bitumen roof underlayment 4.9 Lastobond Eaves ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-surfaced, Protection Sheet Wadsworth,OH SBS modified bitumen roof underlayment 4.10 Lastobond Eco ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced, Gulfport,MS SBS modified bitumen roof underlayment Wadsworth,OH 4.11 Lastobond Smooth Seal ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-surfaced, HT Wadsworth,OH SBS modified bitumen roof underlayment 4.12 PdmeSource Grip-Rite ASTM D1970 Gulfport,MS self-adhering,glass-mai reinforced,film-surfaced, Smooth Seal HT Wadsworth,OH SBS modified bitumen roof underlayment 4.13 RESISTO LB1236 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced, Gulfport,MS SBS modified bitumen roof underlayment Wadsworth,OH 4.14 PrimeSource Grip-Rite ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced, Eave&Valley Protector Gulfport,MS SBS modified bitumen roof underlayment Wadsworth,OH 4.15 RESISTO LB1244 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced, Gulfport,MS SBS modified bitumen roof underlayment Wadsworth,OH 4.16 Colphene FR GR ASTM D1970 and Gulfport,MS self-adhering,fiberglass reinforced,granule- FRSA/TRI April 2012 Wadsworth,OH surfaced,SBS modified bitumen roof underlayment 4 5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report;refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed,a request may be made to the Authority HavingJurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. NEMO ETC,LLC Evaluation Report S18010.06.094U4 Certificate of Authorization x132455 67"EDITION(2017)FSC NON-HVHZ EVALUATION FLZS69-R16 Soprema Roof Underlayments Revision 14:05/28/2019 Page 3 of 8 NNEMO ecce 5.5 Allowable Roof Covers: Wood or Slate or Asphalt Nail-On Foam-On Metal Composite Underlayment Shingles Tile Tile Shakes& Composite Slate Shingles Lastobond TU HT Yes Yes Yes Yes Yes Yes See 5.5.1 Lastobond Shield/Pro HT-N/ Yes No No No Yes Yes RESISTO SA SMOOTH PLY 40 Lastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes EnviroShield Yes No No Yes Yes Yes Lastobond Eaves Protection Sheet/ Yes No No No Yes Yes Lastobond 195 Lastobond ECO /RESISTO LB1236, Grip-Rite Eave&Valley Protector/ Yes No No No Yes Yes RESISTO LB1244 Lastd orid Smooth Seal HT/Grip- Yes No No Yes Yes Yes Rite Smooth Seal HT Colphene FR GR Yes Yes No No Yes Yes 5.5.1 "Foam-On Tile"is limited to use of following Approved the adhesives/underlayment combinations. • •> » • Adhesive Florida Product Approval Underlayments Dow TileBond— FL22525 Lastobond TU HT ICP Adhesives PolyseV AH-160 FL6332 Lastobond TU HT 5.6 Allowable Substrates: o• . Underlayment Primer Substrates Lastobond Shield,Lastobond Pro HT-N,RESISTO SA (Optional)ASTM D41, plywood,OSB,Southern Yellow SMOOTH PLY 40,Lastobond Shield HT,Lastobond Pro HT-S, Elastocol Stick,Elastocol Stick EnviroShield,Lastobond TU HT,Lastobond Eaves Protection Zero Pine(SYP) Sheet,Lastobond 195,Lastobond ECO,RESISTO LB1236, Grip-Rite Eave&Valley Protector,RESISTO LB1244, ASTM D41 structural concrete Lastobond Smooth Seal HT or Grip-Rite Smooth Seal HT Colphene FR GR (Optional)ASTM D41 Plywood ASTM D41 structural concrete Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT,Lastobond Pro HT-S, Dens Deck Prime;SECUROCK EnviroShield,Lastobond TU HT,Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond ECO,RESISTO LB1236, (Optional)Elastocol Stick Zero Gypsum-Fiber Roof Board; Grip-Rite Eave&Valley Protector,RESISTO LB1244, ASTM D226,Type I or II fall; Lastobond Smooth Seal HT,Grip-Rite Smooth Seal HT or Sopra-G;Modified Sopra-G Colphene FR GR 'Refer to 771le Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC,LLC Evaluation Report S18010.06.09-1114 Certificate of Authorization#32455 6''9EDMON(20"1 FSC NON-FIVHZEVALUATION FUS69-1116 Soprema Roof Underlayments Revision 14:05/28/2019 Page 4 of 8 I �NNEMO I ietC. 5.6.1 Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. 5.6.2 Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-adhering underlayment i 5.6.3 For installation under mechanically attached prepared roof coverings,insulation or c&erboard shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile systems(Lastobond TU HT only),insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix D,Testing Application Standard TAS 114,Appendix or UL1897. 5.6.4 For installations under mechanically attached prepared roof coverings,base sheet shall be attached per minimum codified requirements. For installations under foam-on tile systems(Lastobond TU HT only),base sheet shall be attached in accordance with FRSA/TR1 April 2012(04-12)or Section 5.6.5 herein. 5.6.5 wind Resistance for Underlayment'Systems in Foam-On Tile Applications: FRSA/TRI April 2012(04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on the applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12)or FBC 1609 for determination of design wind pressures. #1 Maximum Design Pressure=-45.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)Elastocol Stick,Elastocol Stick Zero or RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT,self-adhered;thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end-laps. #2 Maximum Design Pressure=-67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol Stick Zero Underlayment: Lastobond TU HT,self-adhered;thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end-laps. #3 Maximum Design Pressure=-120.0 psf: Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation:Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional)RESISTO EXTERIOR PRIMER Base Ply: RESISTO SA SMOOTH PLY 40,self-adhered;thorough lyj rolled using hand roller and/or weighted I roller in accordance with Soprema requirements to ensure no voids no bridging at side and end- laps. Underlayment: Lastobond TU HT,self-adhered;thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end-laps. MEMO E C,LLC Evaluation Report S38010.06.09-1134 Certificate of Authorizzation#32455 6'14 EDITION(2017)FSC NON-HVHZ EVALUATION FL2569-R16 Soprema Roof Underlayments Revision 14:05/28/2019 Page 5 of 8 y NNEW I etC. #4 Maximum Design Pressure=-150.0 psf: Deck: Min. 15/32-inch APA-rated B,CX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation:Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional)RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT,self-adhered;thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end-laps. #5 Maximum Design Pressure=-60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC 1517.5.2)spaced 6-inch o.c.at the 4-inch laps and 6-inch o.c.in three(3),equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT,self-adhered;thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging afside and end-laps 5.6.5.1 All other direct-deck, adhered Soprema underlayment systems beneath foam-on the systems carry a Maximum Design Pressure of-45 psf. 5.6.5.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A. Alternatively,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case,Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM'Loss Prevention Data Sheet 1-29 (January 2016)for Zone 2/3 enhancements. 5.7 Exposure Limitations: Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT,Grip-Rite Smooth Seal HT,RESISTO LB1236,Grip-Rite Eave&Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after installation. Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT,Lastobond Pro HT-S or EnviroShield shall not be left exposed for longer than 90-days after installation. Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation. NWO ETC,LLC Evaluation Report 518010.06.09-R14 Certificate ofAuthorkationR32455 6'EDITION(2017)FBC NON-HVHZ EVALUATION F11569-1116 Soprema Roof Underlayments Revision 14:05/28/2019 Page 6 of 8 NNEMOetc, 5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12)): When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. YABLEI TL�,5-uppA.@?Il�nqATEkra—sr-oltDiR-Ec--T=L3E(xfLE,Irq5rA4ATIcFNs Underlayment Tile Profile Staging Method Maximum 7Slope Flat Max.10-tile stack 6:12 Lugged Max.10-tile stack 5:12 Max.10-tile stack(bottom 2-tile stack shall be inverted, 6:12 followed by 8_tiles high on slope,as shown below) Lastobond TU HT 5Q Lugged t Colphene FR GR Flat Max.10-tile stack 5:12 Lugged Max.10-tile stack 6:12 0 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate with Elastocol Stick,Elastocol Stick Zero or.RESISTO EXTERIOR PRIMER(if applicable). 6.3 Lastobond TU HT, Lastob'ond Shield, Lastobond Pro HT-W, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,EnviroShield,Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond Eco,Lastobond Smooth Seal HT,Grip-Rite Smooth Seal HT,RESISTO LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Colphene FR GR: 6.3.1 Non-Tile Applications: Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covaring to be installed,and Soprema published requirements. 6.3.2 Tile Applications(Lastobond TU HT or Colphene FR GR only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual for Self-Adhered Membrane,and Soprema published requirements. For mechanically fastened tile roofing over a 2-ply system,consisting of Base Sheet and Self-Adhered Membrane, fastening of the ASTM D226,Type it base sheet shall be in accordance with Soprema requirements,but not less than that the densities set forth in FRSA/TRI April 2012(04-12),'Table 1. For foam-on tile applications(Lastobond TU HT only),reference is made to Section 5.6.5 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012(04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 3 herein,and Soprema published requirements for tile staging. NEMO ETC,LLC Evaluation Report 518010.06.09-R14 Certificate o/Authodzation'R32455 6-EDITION(2017)roC NON-HVHZ'EVALUATfON FL2569-R16 Soprema Roof Underlayments Revision 14:05/28/2019 Page 7 of 8 Zhu]EM®�etc. l3QlLD,lPJ9,PERMlTo As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MAN Rl Contact the noted QA agency for information on product locations covered for F.A.C.61G20-3 QA requirements. Refer to Section 4 herein for product&production locations having met codified physical properties specifications. UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- 1 NEMO ETC,LLC Evaluation Report 518010.06.09-1134 Certificate ofAuthorization 432455 6-EDITION(2017)FSC NON-HVHZ EVALUATION ' FL2569-R16 Soprema Roof Underlayments Revision 24:05/28/20]9 Page 8 of 8