HomeMy WebLinkAboutProduct Approval metal t' -
1 � • k
1
IYJ •i -pr .... }
BCIS Home Log In i User Registration i Hot Topic ( Submit Surcharge I Stats&Faces ( Publications Contact us I BCIs Site Map ( Links Search
drbProduct
APPiliroval
roti: � USER:public User
Product Approval Menu>Product or Application Search>Application List>Application Detail '
G FL# FL20484-R1
Application Type Revision
Code Version 2617 {
Application Status Approved
Comments
Archived {�
Product Manufacturer UNION CORRUGATING COMPANY
Address/phone/Email 701 S.KING ST.
FAYETTEVILi.E,NC 28301
(910)483-0479 Ext 256
jstieby@unioncorrugating.com
Authorized Signature John Stieby
jstleby@unioncorrugating.com
rte Technical Representative )60/-P60L
!G sf ., .G�� Address/Phone/Email �����o
X +�R
° `PCODE: c� An�c:dOQuality Assurance RepresentativeAddresslPhonelEmati S 1 . L. C[ NTY
Category Roofing u BOC ire
Subcategory Metal Roofing V�✓1or
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional'Engineer
I.—i Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Bala Sockalingam
the Evaluation`'Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration pate 09/07/2027
Validated By Yoosef Lavi,P.E.
E.3 Validation Checklist-Hardcopy Received
Certificate of Independence FU0484 R1 COI Certificatelndependence pdf
Referenced Standard and Year(of Standard) Standard Year
FM 4470 2012
TAS 125 2003
UL 1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code File Cod-'
https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgsT9a49YAgX... 10/12/2019
1'1i3Itt1[i I3Ullulll�' t.Vuc vtuui�.
i
t
Product Approval Method Method 1 Option D
Date Submitted 08/23/2017
Date Validated 08/28/2017
Date Pending FBC Approval 09/01/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description
20484.1 5V Min 26 ga.,24"wide through fastened panel over 15/32"
thick plywood
Limits of Use Installation Instructions i
Approved for use in HVHZ:No Ft20484 R1 ii EvaluationReportC2175 1 pdf
Approved for use outside HVHZ:Yes Verified By:Bala Sockaiingam,P.E.62240
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-169 Evaluation Reports j
Other.Uplift load of 71.0 psf @ fastener spacing of 24"o.c. FL20484 R1 AE EvaluationReportC2175 1 pdf
&169.0 psf @ fastener spacing of 6"o.c. Created by Independent Third Party:Yes
i
20484.2 Advantage-Lok II Min 26 ga,,16"wide concealed fastened panel over 7/16"
thick OSB&15132"&thick plywood
Limits of Use InstallationInstructions.
Approved for use in HVHZ:No FL20484 RI II EvaluationReportC2175 2 pdf
Approved for use outside HVHZ:Yes Verified By:Bala Sockalingam P.E.62240
Impact Resistant:NIA Created by Independent Third Party:Yes
Design Pressure: +N/AI-116 Evaluation Reports
Other:Maximum uplift load of 116.0 psf @ seam fastener FL20484 R1 AE EValuationRenortC2175 2,gdf
spacing of 4-5/8"o.c,along seam Into min. 15/32"thick APA Created by Independent Third Party:Yes
rated plywood with retainer strap.
i
20484.3 Aluminum Advantage-Lok II Max 16.375"wide,nom 0.032"thick(min.)aluminum
concealed fastener roof panel over min 15/32"thick plywood
deck or 7/16"thick OSB.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20484 RI II EvaluationReportC2175 3 pdf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam P.E.62240
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-93.5 Evaluation Reports
Other:Uplift load of 22.5 psf at fastener spacing of 18.5" FL20484 R1 AE EvaluationReportC2175 3.0
o.c.and 86.0 psf at fastener spacing of 4.63"o.c.in 15/32" Created by Independent Third_Party:Yes
plywood or 7/16"OSB.Uplift load of 93.5 psf at fastener
spacing of 4.63"o.c.with structural sealant in 15/32"
plywood.
20484.4 Aluminum SL150 Max 16"wide,nom 0.032"thick(min.)aluminum snap-lock
standing seam metal panel over min 15/32"thick plywood
deck or 7/16"thick OSB
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20484 R1 II EyaivationReportC2175 4 pdf
Approved for use outside HVHZ:Yes Verified By:Bala Sockalingam P.E.62240
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-86 Evaluation Reports
Other:Uplift load of 45.0 psf at clip spacing of 24"o.c,and FL20484 R1 AE EvaluationReportC2175 4.pdf
78.5 psf at clip spacing of 6"o.c.in 15/32"plywood or 7/16" Created by Independent Third Party:Yes
OSB.Uplift load of 86.0 psf at clip spacing of 6"o.c.with
structural sealant in 15/32"plywood.
20484.5 MasterRib Min 29 ga.,36"wide through fastened panel over 15/32"
thick plywood or 7/16"thick OSB
Limits of Use installation Instructions
Approved for use in HVHZ:No EL20484 RI II EvaluationReportC2175 5 odf
Approved for use outside HVHZ:Yes Verified By.Bala Sockalingam,P.E.62240
Impact Resistant:NIA Created by Independent Third Party:Yes
Design Pressure:+N/A/-124 Evaluation Reports
Other:Uplift load of 56.0 psf @ fastener spacing of 24"o.c. FL20484 R1 AE EvaluationRenortC2175 5 pdf
&124.0 psf @ fastener spacing of 6"o.c. Created by Independent Third Party:Yes
20484.6 MasterRib Min 29 ga.,36"wide through fastened panel over 15/32"
thick plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20484 R1 II EvaluationReoortC2175 6 pdf
Approved for use outside HVHZ:Yes Verified By:Bala Sockalingam,P.E.62240
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-$8.5 Evaluation Reports
Other:Uplift load of 56 psf for Fastening System 1.Uplift EI-20484 RI AE Eva luationReportC2175 6.13d
load of 88.5 psf for Fastening System 2. Created by Independent Third Party:Yes
https://www.floridabuilding.org/pr/pr app__dtl.aspx?paraln--,wGEVXQwtDgsJ9a49YAgX... 10/12/2019
Florida'Building Code OnlinePage 3 of 3
20484.7 ML250 Max 16.5"wide,min 24 ga.steel standing seam panel over
15/32"thick plywood
Limits of Use Installation Instkuctions
Approved for use in HVHZ:No FLZ0484 RI 11 Evaluation ReportC2175 7.vd
Approved for use outside HVHZ:Yes Verified By:Bala Sockalingam,P.E.67240
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/Al-124 Evifluation Reports
Other:Maximum uplift load of 124 psf @ clip spacing of 6" FL20484-111 AE EvaluaticinpecortC2175 7.pd
o.c.with 180 seam,self-adhering membrane and fixed clip. Created by independent Third Party.Yes
20484.8 PBR or R Panel Min 26 ga.,36"wide through fastened panel over 15/32"
-thick plywood
Limits of Use installation Instructions
Approved for use in HVHZ.No FC20484 R1 IT EvaluationllenortC2175 8.pd
Approved for use outside HVHZ:Yes Verified By:Bala Sockalingam P.E.62240
Impact Resistant:N/A CtLated by Independent Third Party:Yes
Design Pressure:+NIAI-161.5 Evaluation Reports
Other:Uplift load of 30.0 psf at fastener spacing of 48"D.C. FL20484 R1 AE EvaluationikeportC2175 8,Qd
and 161.5 psf at fastener spacing of 6"D.C. Created by Independent Third Party:'Yes
20484.9
Max 18"wide,min 24 ga.,snap-lock standing seam metal
panel over 15/32"thick plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20484 R1'IT Eva luat1onReg9rtC2175 9.pdf
Approved for use outside HVHZ:Yes Verified By:Bala Sockalingam,P.E.62240
Impact Resistant:N/A Created by Independent Third Party:Yes
.Design pressure:+NW-93.5 Evaluation Reports
Other:Uplift load of 39.8 psf @ clip spacing of 36"o.c.and Fb0484 R1 AE EvaluationReportC2175 9:pd
78.6 psf @ clip spacing of 8"o.c with felt.Uplift load of 93.5 Created by Independent Third Party:Yes
psf @ clip spacing of 12"o.c.with self-adhering membrane.
Back FN..tl
Contact Us::2691 Blair Stone Road,Tallahassee FL 32.399 Phone:859-487-1824
The State of Florida is an AA/EEO employer.Cgovdahl 2007-2013 State of Florida,::Privacy Statement::Accessibility Statement::RefundStatement
I
Under Florida-law,email addresses are public records.If you do not want your e-mail address released in response to a publlc-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,'F.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click here_.
Product Approval Accepts:
Credit Card
Safe
10 1
littps://www.floiidabuilding.org/prip r� app dti.aspx?param=wGEVXQWtDqsl9a49YALrX... 10/12/2019
EVALUATION REPORT OF
UNION CORRUGATING COMPANY
`26 GA.5V PANEL'
FLORIDA BUILDING CODE 6TH EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 20484.1-RI
ROOFING
METAL ROOFING
Prepared For:
Union Corrugating Company
701 S.King St.
Fayetteville,NC 28301
Telephone: (910)483-0479
lFax: (910)483-1091
Prepared By:
Bala.Sockalingam,Ph.-D., P.E.
Florida Professional Engineer#62240
1216 N Lansing Ave.,Suite C
Tulsa,OK 741:06:
Telephone: (918)492-8992
FAX: (866)366-1543
This report consists of
Evaluation Report(3 Pages including cover)
Installation.Details (I Page)
Load Span Table(I Paige)
XASE
co LU
Report No. 02175-1 0
Date: 8.23.2017
� 22.
FL 20484.1-RI
C2175-1
8.23.2017
Page 2 of 3
Manufacturer: Union Corrugating Company
Product Name: 5V Panel
Panel Description: 24" wide coverage with.(5) 1/2"high ribs
Materials: Minimum 26 ga., 80 ksi steel. Galvanized coated steel (ASTM A653)
or Galvalume coated steel (ASTM A792) or painted steel (ASTM
A755).
Deck Description: Mmim 15/32" thick APA rated plywood or min. W thick wood plank
(min SG of 0.42) for new and existing constructions. Designed by
others and installed as per FBC 2017.
New Underlayment: Minimumunderlayment as per .FBC 2017 Section 1507.4.5.1.
Required for new construction.
Existing Underlayment: One layer of asphalt shingles over one layer of#30 felt. For reroofing
(Optional) construction only.
Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2
Design Uplift Pressure: 71.0 psf @ fastener spacing of 24" o.c.
(Factor of Safety=2) 169.0 psf @ fastener spacing of 6" o.c.
Panel Attachment: #10-15 x 2" tong wood screw with washer
At interior @ max 12" o.c. across panel width through panel rib
At panel ends @ max 6" o.c. across panel width through panel flat and rib
Test Standards: Roof assembly tested in accordance with LTL580-06 'Uplift Resistance
of Roof Assemblies' & ULI897-04 'Uplift Tests for Roof Covering
Systems'.
Test Equivalency: The test procedures in UL 1897-04 comply withtest procedures
prescribed in UL 1897-12.
Code Compliance: The product described herein has demonstrated compliance with FBC
2017 Section.1-507.4.
Product Limitations: Design wind loads shall be determined for each project in.accordance
with, FBC 2017 Section 1600 or ASCE 7-16 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. The design pressure for reduced fastener spacing may be
computed using rational analysis prepared by a Florida Professional
Engineer or based on Union load span table. This evaluation report is
FL 20484.1-R1
C2175-1
8.23.2017
Page 3 of 3
not applicable in High gh Velocity Hurricane Zone.Refer to current NOA
for use of this product in High Velocity Hurricane Zone. Fire
classification is not within scope of this Evaluation Report. Refer to
FBC 2017 Section 1505 and: current approved roofing materials
directory or ASTM E108/UL790 report from an accredited laboratory
for fire ratings of this product.
Supporting Documents: UL580&UL1897 Test Reports',
Farabaugh Engineering and Testing Inc.
Project-No" . T197-16,Reporting;Date 5/12/16
PANEL OVERLAPPANEL FASTENER
II Q m-
nm: w1c
NEW UNDERLAYMENT
ROOF PANEL SEE DETAIL 2 SEE DETAIL 'I SPACING PER ALLOWABLE
^ r UPUFT LOAD TABLE
I
7EXISTINGMENT EXISTING SHINGLES DECK AITACIiMEPTf AND PLYW(OPTIONAL) SUPPORTS MUST BE
15/32" THICK (MIN.)
'DESIGNED AND INSTALLED
BY OTHERS
MIN. 2X,. WOOD RAFTER/JOIST/
TRUSS AT MAX, 24" O.C.
TYPICAL PANEL INSTALLATION X—SECTION
d o
#10-15 X 2" LONG WOOD F Nv-
SCREW WITH WASHER �z 4
coz9"e7
Yj
MSN 26 GA. PANEL 011 o
NEW UNDERLAYMENT j
z n��
_ xZ) 8.
EXISTING SHINGLES:
(OPTIONAL)
EXISTING UNDERLAYMENT 6 �_
(OPTIONAL) PLYWOOD - d
15/32° THICK (MIN.) x m
DETAIL 1 z s=
GENERAL NOTES: > a AVS
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE 5
x#10-15 X 2" LONG WOOD FLORIDA BUILDING CODE (FBC).
SCREW WITH WASHER 2. ROOF PANELS SHALL BE MINIMUM 26 CA. EFFECTIVE COVERING WIDTH OF - 5N
PANEL = 24" ; »
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING:&STRUCTURE AS
NEW UNDERLAYMENT MIN 26 GA. PANEL SPECIFIED ON THIS DRAWING,
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT,
THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN
WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOAD TABLE.
5, ALL FASTENERS MUST BE IN.ACCORDANCE WITH THIS DRAWING & THE FLORIDA
BUILDING CODE IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
EXISTING SHINGLES REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL.
(OPTIONAL) 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
VD REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS,
EXISTING UNDERLAYMENT
(OPTIONAL) D ETAI L 2 PLYWOOD5 /3" THICK (MIN.)
C2175N 1 tV.
511££7 NO.
1 of 1
UNION CORRUGATING COMPANY
5V Panel Uplift Loads
(J' W 26 ga.)
Description Fastener Spacino, Allowable Uplift
along Panel Length ; Load
(in)
Coverage width: 24" 6 169.0
8 158.1
Panel Fasteners 10 147.2
#10-15 hex head screws with 12 136.3
sealed washer 14 121.7
16 106.5
Panel fasteners spaced at 1211 18 94.7
o.c. across panel width ---------85.,2
through ribs. 29 77.5
24 71.0
Notes:
1. The hold numbers indicate design loads calculated from.test data with safety factor of 2.
2. Panels must be installed as per Evaluation Report FL 20484.1 and Union current installation procedure.
— 0
......A4,1
BBQ
rb?.VP
cr, a.
L 0
'S I MA
1216 N Lansing Ave.,Suite C
Bala Sockalingam,Ph.D.,P.E.
Tulsa,Ok 74106 FL 62240