Loading...
HomeMy WebLinkAboutProduct Approval 11/512019. Florida Building Code Online iiuk SCIS Name # Lag In { User Registration i HOtTopics { Submit Surcharge £ Stats&Facts { Publicat+ons Contact Us i BOTS Site Map { [.mks ; Search ;~ Product Approval `'' USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail r JAN 2 7 2020 r.= V_r-=-: FL.4 FL10674-RIS SF. Lucie County, Permitting Application Type Revision Code Version 2017 Application Status Approved Comments Archived FILE "OPO"tf Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscoming.com Authorized Signature Greg Keeler greg.keeler@owenscoming.com Technical Representative Mei Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo,OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation'Report-Hardcopy Received Florida Engineer or Architect Name.who developed the Robert J.M.Nleminen Evaluation Report Florida License PE-59166 Quality Assurance Entity PRI Construction Materials Technologies,LLC. Quality Assurance Contract Expiration Date 04/2012020 Validated By John W.Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R15 COI 2019 01 COI NIEMTNEN pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 Equivalence of Product standards Certified By Sections from the Code https://florldabililding.org/pr/pr app dtl.aspx?param=wGEVXQwtDqtBNbEY5V%2boQT%2b6w7ahReglCQ8ucR6lxEDL76gG32Q9MA/e3d%3d 1/2 � r 09115/2019e Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 08/15/2019 Date Validated 08/15/2019 Date Pending FBC Approval 08/21/2019 Date Approved 10/15/2019 Summary of Products FL# Model,Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge shingles Shingles and Starters 'Limits of Use Installation Instructions Approved for use in HVHZ:No FL10674 R15 II 2019 08 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10.674-1115.pdf Impact Resistant:N/A Verified By:Robert J.M.Nieminen PE-59166 Design Preassure:Ai/A Created by Independent Third Party:Yes Other:Refer to ER,Section 5. Evaluation Reports FL10674 R15 AE 2019 OB FINAL ER OC ASPHALT SHINGLES FL10674-R15.Ddf Created by Independent Third Party:Yes • i'ra.ta s�'ert Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:950-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::PrivacyStatement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.;Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter45S,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication vilth the licensee.HoweVer email addresses are public record.If you do not wish to supply a personal address,please provide the Departmentwith an email address vihich can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: `t r its: Credit Card Safe https://floridabuilding.org/prlpr app dti.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT°/g2b6w7ahReglCQ8ucR6ixEDL76gG32Q9MA%3d%3d 2/2 tr Certificate of Authorization#32455 4> �. 353 Christian Street, Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EvALuATE TEST CONSULT CEP.iIFy rK ON"01 IN 11111 Owens Corning Evaluation Report 037940.02.12-R10 One Owens Corning Parkway FL10674-1115 Toledo,OH 43659 Date of issuance:02/0612012 (740)404-7829 Revision 10: 08115/203.9 SCOPE: This Evaluation Report is issued under Rule 63.020-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product underthe Florida Building Code and Florida Building Code,Residential Volume. The products described herein have been evaluated for compliance with the 6tt,Edition(2017)Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be' in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.3./R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s),the Quality-Assurance or the production facility'location(s). NEW I etc, requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then itshall be done in its entirety. iNSPEcriON:Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection atthe job site atthe request of the Building Official. This Evaluation Report'consists of pages 1 through 10. Prepared by: Robert3.M.Nieminen P.E. The facsimile seal appearing was authorized by Robert Nieminen,P.E.on 08/15/2019.This does notserve as an O, J'��;. Florida Registration No.59166,Florida DCA ANE1983 '.•r'dane:,;i�+��� elearonically signed document. CERTIFICATION OF INDEPENDENCE? 1. NEMOI etc. does not have, nor does it intend to acquire, or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO I etc.is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor-will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO Ietc.nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018,NEMO ETC,LLC ' . t i O (ROOFING SYSTEMS EvAwAmON. p> Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 61 Edition(2017)Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. Section ProloertV Standard Year 1507.2.4,R905.2.3 Physical Properties ASTM D1970 2015 1507.2.5,R905.2.4 Physical Properties ASTM'1)3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 Entitv Examination Reference Bate Owens Corning Declaration Equivalency Declaration 08/06/2019 PRI(TSTS878) ASTM D1970 OCF-382-02-01 10/24/2017 UL LLC(CER9626) Physicals&Wind Resistance File 82453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 ULLLC'(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various PRI(QUA9110) Quality Control Service Confirmation 04/05/2020 +�Ix °•4D D o 4.1 ACCESSORY STARTERS. 4.1.1 Starter Strip Shingle,Starter Strip Plus and SRS TopShield Starter are starter strips for asphalt roof shingles. Meets ASTM D3462. 4.1.2 Starter Shingle Roll is a mineral-surfaced,fiberglass-reinforced,self-adhering SBS modified bitumen starter strip, nominal 7.2-inch wide x 33-ft 4-inch long roll,for use with asphalt shingles. Meets ASTM D1970. 4.2 ASPHALT SHINGLES: 4.2.1 Classic and Supreme"are fiberglass reinforced,3-tab asphalt roof shingles.Meets ASTM D3462. 4.2.2 Berkshire'are fiberglass reinforced,4-tab asphalt roof shingles. Meets ASTM D3462. 4.2.3 Duration,TruDefinition'Durationo, Duration*Premium Cool,TruDefinition Duration'Designer Color Collection, TruDefinition°Oakridge, Oakridge and WeatherGuard" HP are fiberglass reinforced, laminated asphalt roof shingles.Meets ASTM D3462. 4.3 HIP&RIDGE SHINGLES: 4.3.1 Berkshire'Hip&Ridge Shingles with Sealant,DuraRidge°Hip&Ridge Shingles with Sealant,ProEdge°Hip&Ridge Shingles and WeatherGuard*HP Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. Meets ASTM D3462. MEMO ETC,LLC Evaluation Report 037940.02.12-R10 Certificate ofAuthorization#32455 6'H EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-RIS Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 2 of 10 NNEMOle-kC. 5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 53 . Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire.ratings of this product. 5.4 'Wind Classification: 5.4.1 The Owens Corning asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating acceptable use in all wind zones up to Vagd=150 mph(V„It=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Note: Classification by ASTM D7158 applies only to exposure category B or C,as defined in FBC 1609.4.3,and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.2 Starter Strip Shingle,Starter Strip Plus and SRS TopShield Starter noted in Section 4.1.1 and the Owens Corning hip ridge shingles noted in Section 4.3 are Classified in accordance with FEC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating acceptable use in all wind zones up to Vagd=150 mph(Volt=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. 0 G.J. GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof(tear-off) or recover applications,subject to the limitations set forth in FBC Section 1511 or R908 and published installation instructions. 6.2 ACCESSORYSTARTERS4 6.2.1 Installation of Starter Strip Shingle,Starter Strip Plus and SRS TopShield Starter shall comply with the Owens Corning current published instructions,using minimum five(5)nails per strip. Felt undeilaynient Deck Feltundrdayment 0ed: Sei'adhutd I yl tF.eraek: s. Self•adheied. untler6ynen: ' I � lyeatherhstk° Andeslayrrent rL. Dripdo. Utnedge VAIslotated V- 2%3•from cave 2'-3"frons esve tnstaU firs! Selfaealin adhesive '• SaG°vaHngadhesivc 9 hstaH GntStarterStrip Phe pu5donrd:�ing cave SlaRerStrtyy - •-• positioned.long cave wnhsranoved ' 6"removed eserahanascvesndnkc:7f4'•-3li' ' St2rter5idpahingie overhangs eavesand ml:es 151—W' St. Figure 1:Minimum Nailing,Starter8trip Figure 2:Minimum Nailing,Starter Strip Plus NEIMO ETC,LLC Evaluation Report 037940.02.12-R10 certificate o}Autharizationl132455 6TH EDITION(2017)FBC NON-HVHZ EVALUATION F119674-R15 Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 3 of 10 1 6.2.2 Installation of Starter Shingle Roll shall comply with-the Owens Corning current published instructions. Deck Underlayment Drip edge ^: Drip edge Starter Shingle Roll adhered directly to underlayment and primed drip edge Self-sealing adhesive positioned along eaves Figure 3:Starner Shingle Roll 6.3 ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four(4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions: 9 Berkshire'shingles require minimum five(5)nails per shingle. 9 WeatherGuard@ HP shingles require minimum six(6)nails per shingle. Where the roof slope exceeds 21 units vertical in 12 units horizontal,special methods of fastening are required Referto Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Classic°&Supreme: o¢¢roal mansarai or ,Area para Normal Mansard or Area para Wind Areas High Wand desvanes y Wind Areas High Wind desvanes y Area para vrentps normales Areas vientos Mertes Area para Wentos normalas Areas vienfos fararres 2" 1131 i 7727 ,�(A) 727 �~ r7. 5°Exposure 5918°exp®sur® Exprosici6n Exposieian Figure 4:Minimum Nailing,Classic&Supreme figure 5:Minimum Nailing,Classic&Supreme (Standard Size) (Metric Size) NEPAO ETC,LLC Evaluation Report 037940.02.12-1110 CertifcateofAuthorizotion!132455 6n{EDITION(2017)FBC NON-HVHz EVALUATION FL10674-R25 Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 4 of 10 MEMO &tC" 6.3.1.2 Berlcshire°: Sealant strip Sealant strip I La lira deseJladu J La lira desella4ur E r.r3 4--� a �-i ------------ 9�1" 91:" RYi `` 8riz" exit' 8?h 3?2' Jd 1 c c A Figure 6: 5-Nail Pattern,Berkshire Figure 7: 6-Nail Pattern,Berkshire 4 Sealant strip to Sia desANadar 004x_...-_. `05 3© 0'4—�'!O4-��lfl 8 Jz" 816" 8 V< c A 1 r'3 i Qr�bd 2" Asphalt roGring cement Cea:enta da techo da asFfla Figure 8: Mansard or Steep Slope Pattern,Berkshire MEMO ETC,LLE Evaluation Report 037940.02.12-1110 Certificate of Authorization#32455 6-EDITION(2017)FBC NOAI-}iVHZ EVALUATION FL10674-1115 Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 5 of 10 �NNEMO etC. 63,1.3 Duration®,TruDefinition°Duration Duration°Premium Cool&TruDefinitiono Duration°Designer Color Collection: 4-Nall Fastening Pattern SureNail®fastening amavridth Nail,Typieal 1„ 42" 12" q, QnzaacemingSureTlade!. �;.{;t.'.vnSociwb�sat::p :0 '•Diams cwbasiii r+• .:63' ' expppwa Figure 9!Standard 4-Nail Pattern,Duration 6-Nail Fastening Pattern SureNail®fastening area vAdth IYaR,Typioal !+ 3" 42" 12" 1" '--'�^ 4rrEnsCo:nia3 Sur�.'z7e1 p _pa,angauna Ei 0.' 6-118" 5-sl9" expnsweF1 Figure 10: 5-Nail Pattern,Duration Fastening for Slopes Greater Than 21:12 SureNailO fastening area width Nail,typical 1„ 92" � 12„ I„ a,rren•,tomig75um7...9� `A ,Q7gtam5 au;fuu7sua.ld t1 O O:,al4C�ina Suti:alt7 'O 6-119" 5.518" exp6swe ' Four9"Spots ofAsphalt Roofing cement Figure 11: Mansard.or Steep Slope Pattern,Duration WNW ETC,LLC Evaluation Report 037940.02.12-R10 CerticateofAuthorization#32455 6TH EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 6 of 10 -t NEMO j e Co 6.33..4 TruDefinition°Oakridge°,Oakridge°: 4 Nei!Pattens ,Esquema coni claws V ,FF ii 12" fl 1*� v. YI L 5 518"Cxposure Nails 5 679"Exposule &7raslydA,.tde-alspatg. Gtr�flas F.xpasira612de6618pu1g Figure 12:Standard 4-Nail pattern,Oakridge 6 Nail Pattern Esguema con S ciauos r 5 619"Fxposute ails 5 519"ex ole Glarus expos xposleffin do5518puts. lxposicfm da 65jigp:s7_o. Figure 13:6-Nail Pattern,Oakridge Fastening for Slopes Greater Than 21:12 Sur.Naltl rst.ntog ore.ivtath fj'Nall,ljpica! IF JZ, 6 t/8''5wesw - t t © 7j2 Fours"Spots ofAsphatt Roofing Cement Figure 14:Mansard or Steep-Slope Pattern,:Oakridge MEMO 9rC,LLC Evaluation Report 037940.02.22-RIO certi}icate ofAuthorization#82455 6'R EDITION(2017)FBC NON-HVHZ.EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 7 of 10 o MEMO -&C. 6.3.1.5 Weath&GuairdO HP: 12" 12, 12 Flo, p:19 12pdg. Figure 3.5;6-Nall Pattern,WeatherGuard HP Esquerria con 6 clavos Nall 6113°from bottom of shingle Clove a 6 118julj.de In 6 6 616"Exposure Nen sters putg inleflar a is tqa ExpasiGIN do 5 518 pulg. 6 sojeledoras UP4 four 1'Spots of Asphalt Mal Cement Cuntrojountios dV4:vm@z10 de facha dassfieffa do I pv&da Figure 16:Mansard or Steep-Slope Pattern,WeatherGuard HP 6.4 Hip&RIDGE SHINGLES? 6.4.1 Installatlibn of asphalt shingles shall comply with the Owens Corning current published instructions. > Berkshire*Hip and Ridge Shingles with Sealant and DuraRidgeO Hip& Ridge Shingles with Sealant require minimum two(2)nails per shingle. > WeatherGuard' HP Hip and Ridge Shingles and ProEdgeO Hip &Ridge Shingles require minimum four(4) nails per shingle. Refer to Owens Coming published information on wind resistance and installation limitations. MEMO ETC,LLC Evaluation Report 037940.02.12-RI0 Certificate of Authafizotion#32455 01 EDITION f2017)Fi3C j)ION-HVHZ EVALUATION FI-10674-R15 Owens Corning Asphalt Roof shingles Revision 10,08115/2019 Page 8 of 10 04NEMO�OtC- 6.4.1.1 Berkshires Hip&.Ridge with Sealant and DuraRidg&Hip Ridge Shingles with Sealant: Fig. A Fig. B Prevailing Wind Direction Top View �—Direcci6.n del viento predolninante Alin Vista superior V,I¢� 4 Nail 2$/s, ClawNails A 5/ o Owens Corning SurbM' a Clavos 4 I l p l� I 1 j Ml F I I I I n o Jl l �tirpo iEonde$pulg �i a 1211 4 I Figure 17:Isometric View,Berkshire and DuraRidge Figure 18:Plan View,Berkshire and DuraRidge 6.4.1.2 Weatherftard®HP Hip&Ridge Shingles: Fig.A Fig.C Hip&Ridge Shingle Fastening PrevalflagY;gnd TopVWei, `E-o1redlon Nalls T q A i I Netts 140119 A I I 7" 2 2 I I V 1 1. Expo urs s Exposure 12" 1 Figure 19:Isometric View,WeatherGuard HP Hip&.Ridge Figure 20:Plan View,WeatherGuard HP Hip&e Ridge MEMO ETC,LLC Evaluation Report 037940.02.12-R10 Certificate of Authorization#32455 6TH EDITION(2017)F13C NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 9 of 10 ONEMOILg�° 6.4.1.3 ProEdge®Hilo&Ridge Shingles: 4°rov Uing Standard ildirnd Direction tine Fast+enin-9 Seohirit Strip �" Pattern T 9 f S4! ant sten 771° 79/=i TExposure Cover Exposed Fasteners�TaItb Roof Gement Figure 21:Isometric View,ProEdge Figure 22• Plan View,ProEdge 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 J R905.2.6.1. 07 e io o As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. W U 0 Contact the named QA entity for information on which plants produce products covered by Florida Rule 61620-3 QA requirements. PRI Construction Materials Technologies,LLC—QUA9110'; 813 621-5777;bwilson@pricmt.com END OF EVALUATION REPORT- MEMO ETC,LLC Evaluation Report 037940.02.12-R10 Certificate of Authorization 1132455 6TH EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 10 of 10 ,r -10/24/2019 Florida Building Code Online 4i !{ 1 f I � 91 BCIS Home Log In User Registration Hot Topics I Submit Surcharge Stats&Facts f Publications Contact Us SCIS Site Map Links Search d,b�,,"O`dpr , PER:Pubicct User vol USER:Public User Product Approval Menu>Product or Application Search>Application Lis t>Application Detail FL# FL9777-R11 - ------- Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscoming.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the.Zachary R.Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden P.E. ' Validation Checklist-Hardcopy Received Certificate of Independence FL9777 R11 COI OCR14002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D 1970 2015 ASTM D 226 2009 ASTM G 155 2005 TAS 103 1995 UL 1897 2012 Equivalence of Product Standards Certified By Sections from the Code https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtgkcMG.blcW71%2fZr7gdugvKEIMFg53ndV601883S636Kw%3d%3d 1/3 10/24/2019 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 10/11/2017 Date Validated 10/11/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 9777.1 Weatherlock G Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ:No FL9777 R11 II OCR14002.8a 2017 FBC Evaluation Report Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ.pdf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL9777 R11 AE OCR14002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.pdf Created by Independent Third Party:Yes 9777.2 Weatherlock G(High Tear) Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ:No FL9777 R11 II OCR14002.8a 2017 FBC Evaluation Report Approved foruse outside HVHZ:Yes Weatherlock Non-HVHZ.pdf Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL9777 R11 AE OCR14002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.pdf Created by Independent Third Party:Yes 9777.3 Weatherlock MAT Waterproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL9777 R11 II OCR14002.8b 2017 FBC Evaluation Report Approved for use outside HVHZ: No Weatherlock HVHZ.pdf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL9777 R11 AE 0CR14002.8b 2017 FBC Evaluation Report Weatherlock HVHZ.pdf Created by Independent Third Party:Yes 9777.4 Weatherlock MAT Waterproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL9777 R11 II 0CR14002.8a 2017 FBC Evaluation Report Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ.pdf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL9777 R11 AE OCR14002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.pdf Created by Independent Third Party:Yes 9777.5 WeatherLock Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ:No FL9777 R11 II 0CR14002.8a 2017 FBC Evaluation Report Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ.pdf Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL9777 R11 AE OCR14002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.pdf Created by Independent Third Party:Yes 9777.6 WeatherLock Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL9777 R11 II OCR14002.8b 2017 FBC Evaluation Report Approved for use outside HVHZ: No Weatherlock HVHZ.pdf Impact Resistant: N/A' Verified By: Zachary R. Priest PE-74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtgkcMGbIQW71%2fZr7gdugvKE1 MFg53ndV601883S636Kw%3d%3d .2/3 10/24/2019 Florida Building Code Online FL9777 R11 AE OCR14002.8b 2017 FBC Evaluation Report Weatherlock HVHZ.pdf Created by Independent Third Party:Yes 9777,7 WeatherLock Specialty Tile&Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL9777 R11 II OCR14002.8a 2017 FBC Evaluation Report Approved for use outside FIVHZ:Yes Weatherlock Non-HVHZ.pdf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design pressure, +0/-142.5 Created by Independent Third Party:Yes other:See evaluation report for limits of use. Evaluation Reports FL9777 R11 AE OCR14002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.pdf Created by Independent Third Party:Yes ' C9:-Cit it?e-rt Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your a-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: WON E9 E Credit Card Safe https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtgkcMGb[cW71°/a2fZr7gdugvKEIMFg53ndV601883S636Kw%3d%3d 313 ( REE 0 K Certificate of Authorization No. 29824 1752 Tampa, FL 333647 T F—C mvnC AL SE RIAC ES9 LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11, 2017 1 Owens Corning Parkway Toledo, OH 43657 (800)438-7465 www.owenscornifi.g.com Manufacturing Location: Brentwood, NH Houston,TX Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategoey: Underlayments Code Sections: 1504.3.1, 1507.1.1 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies(TST5878) NEI-039-02-01 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) NEI-042-02-01REV2 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) NEI-045-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST5878) NEI-045-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST5878) NEI-053-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST5878) NEI-053-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST5878) NEI-093-02-02 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF-213-02-01 ASTM D 1623 2009 PRI Construction Materials Technologies(TST5878) OCF-237-02-01 UL 1897 2012 PRI Construction Materials Technologies(TST5878) OCF-252-02-01 ASTM D 4798 2001 PRI Construction Materials Technologies(TST5878) OCF-252-02-01 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF-253-02-02 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF-272-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST5878) OCF-296-02-02 ICC-ES AC 188' 2012 ICC-ES AC 48 2012 PRI Construction Materials Technologies(TST5878) OCF-297-02-01.1 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF-318-02-01 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF-320-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST5878) OCF-320-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST5878) OCF-321-02-01 ASTM D 1623 2009 PRI Construction Materials Technologies(TST5878) OCF-322-02-01 UL 1897 2012 PRI Construction Materials Technologies(TST5878) OCF-355-02-01 UL 1897 2012 'Determined to be equivalent to ASTM D 226-09,Type I and II OCR14002.8a FL9777-R11 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. . /�� OWENS CORNING ROOFING AND ASPHALT LLC i�C"`�S � ;�. WeatherLock®Self-Sealing Ice to Water Barriers 9 Ii;.,cHNICAL.SF-RVICES, LLC PRODUCT DESCRIPTION AND LIMITS OF USE WeatherLock®G WeatherLock®G is an ASTM D 1970 self-adhesive underlayment constructed from SBS (Brentwood, NH) modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq.rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock® G is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock®Mat WeatherLock® Mat is an ASTM D 1970 self-adhesive underlayment constructed from (Brentwood, NH or SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1- Houston, 7X) sq.rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock® Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock®Metal WeatherLock®Metal is an ASTM D 1970 self-adhesive underlayment constructed from (Brentwood, NH) SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The product is supplied in 2.0 sq.rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock®Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 90 days. WeatherLock® WeatherLock® Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment Specialty Tile&Metal constructed from SBS modified asphalt and surfaced with a non-woven polyester fabric. (Brentwood, NH or The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft. Houston, 7X) WeatherLock® Specialty Tile & Metal is permitted to be used as prescribed in FBC Section 1507.1.1. WeatherLock® Specialty Tile & Metal is permitted to be used with adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (ICP Adhesives and Sealants, Inc.)or TILE BONDTM Roof Tile Adhesive (The Dow Chemical Company). Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete tile installations without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stack. WeatherLock®G(High WeatherLock®G(High Tear)is a self-adhered, underlayment used as an alternative to Tear) ASTM D 226,Type I or Type II roofing felt and ASTM D 1970 self-adhering polymer (Houston, TX) modified bitumen underlayment. The underlayment is composed of SBS modified asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal dimensions of 3-ft x 65-ft. WeatherLock® G (High Tear) is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. OCR14002.8a FL9777-R11 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. . . CREEK [��N8��RNN8ROOF�GAND AOPHA�'�C �=*�~��8����"2�� -'-- ---' oeatbmgock@ Self-Sealing Ice&Water Barriers TFcHmXCAL SERwcEs,KLC PRODUCT APPLICATION Min. Roof Slope: 212|naccordance with the F8C Application: All undarlaymsmtsshall beinstalled/naccordance with the FB(l Deck substrates shall be clean, and free from any irregularities and debris. All application. Prior to beginning installation, the —.-_-,—_^ shall be unrolled and allo wed torelax for aminimum of3-5minutes. The undadaymentshall boinstalled 4iththe release backer removed and pressed into p�oetoensure uom complete contact with thedeck. Th d d firmly ' with the "ux /oogm panmno/ to the mave' starting at the eave, and with minimum 3" side laps and minimum O"end| Additionally, if applying uk@ Specialty Tile & Metal, end kypn shall be primed with ASTM D 41 primer orsealed With asphalt roof cement dminimum of3-4inches across the width ofthe lap. Kispermissible toback nail the unded ent12-inoh on-center oeneeded(nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the o n ' Additionally, VVeotherLnck@Specialty Tile & Metal shall beback nailed when installed mnroof slopes greater than 3:12. Min.Application 40"F; Contact the manufacturer when installing at temperatures below the minimum Temperature: application temperature. WIND RESISTANCE The Maximum Design Pressures shown below were calculated using e2:1 margin ofsafety per F8CSection 1504.9. Underlayment System No.I —Weatherl-ock Specialty Tile&Metal Onlv Roof-Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24"o.c. Undedoymont W*atharLmck@ Specialty Tile & Metal aho|| be applied in oocondonoa with .manufacturers installation instructions hothe fastened deck and buckneUed along the selvage with minimum 12ge,' 1-1/4-inch galvanized ring shank roofing nails through optionally primed, 32ga, x 1-5/0-inoh 0 tin uope spaced 12" o.c. The applied underbyment shall be rolled with a minimum 751b mbem| roller immediately following . application. Maximum Design -142.5pof Pressure: ' 0CR14002.8a FL9777-R11 Page 3 of 4 II OWENS CORNING ROOFING AND ASPHALT LLC I �. WeatherLock®SelfSealiingIce&Water Barriers . . GENERAL LIMITATIONS 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck. 7) The underlayment may be used as described in other current FBC product approval documents. 8) Design wind Toad pressures shall be determined for components and cladding in accordance with FBC 1609. 9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads determined for the roof assembly. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 6th Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. eeaeeaeseoo�o�oo 0 R p9ee oe ®OPP G ►vsF��s® -. .2017.10011 m No 7402112,eG09006.29 b G v � mm 0ycry.Yaegi.cm,0.Pont �-� • ¢C -04'00' o�••, STATE OF .'4410 ��T••.� P =4o Zachary R. Priest, P.E. eo°ods.,< p R t O,.• N®0o Florida Registration No.74021 °e4*NA�� �®® Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned, operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E.does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process,of the product. END OF REPORT OCR14002.8a FL9777-R11 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule.61G20-3. The manufacturer shall notify CREEK, Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not specifically addressed herein.