Loading...
HomeMy WebLinkAboutRevisions OFFICE USE ONLY: DATE FILED: l c�- PERMIT# I t REVISION FEE: �. b C) RECEIPT PLANNING&DEVELOPMENT SERVICES BUILDING&CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE,FL 34982-5652 (772)462.1553 APPLICATION FOR BUILDING PERMIT REREV PROJECT INFORMATION LOCATION/SITE ADDRESS: 41 DETAILED DESCRIPTION OF PROJECT REVISIONS: AZ L CONTRACTOR INFORMATION: STATE of FL REG./CERT. ST.LUCIE CO CERT.#: BUSINESS NAME: ��� 12o�FLNh �- 4 1- N_S >c ' QUALIFIERS NAME: ADDRESS: Zt<- �, &)da-r¢1,J AW9 CITY: STATE: re-- ZIP: �2's a; PHONE(DAYTIME�L d1�2(a -Z)4" FAXr&4Q1 42-6, 44-2- - OWNER/BUILDER INFORMATION: NAME: &4W L`/nJ/J 4 VJL.69 ADDRESS: a-7 V,%VA CITY: pEr, FT,657Zr-�,5 STATE: L ZIP: 34-q`a W- PHONE(DAYTIME:(''rz13s� eii2,6 FAX: ARCHITECT/ENGINEER INFORMATION: NAME: s b:a ADDRESS: CITY: - STATE: ZIP: PHONE(DAYTIME): FAX: R SLCCC:9/23/09ED RECEIV ED Revised 06/30/17 JAN !!2 ozo Permitting Department St. Lucie County, FL J1 j ST 4 l METAL ROOFINO UFILE COPY Knowledge—Sertiice—Selection Since 1998 P - 5 1q q -17-2020 To whom it may concem, V Coast:Metal Roofing Supply Florida product approval io section paragraph?references re-roofing applications shall be installed in,accordanee with the 2017 Florida Building Codes Section 1507.4& 151 1-for the re-covering over existing roofs., 4'Ve approve our product over existing roof and the use of`Ultra HT Wind&Water Seal's under the "roof covering system (optional whet `there is Secondary water barrier existing). y Sincerely, Customer Service t " Dots REVI F FOR C�®ECO MPLIANCE STa E.IJCI — U 'Y BOA G' w : 'E 'V 1 " ION t .N CBUCK .-Engineering SpeEiaf J Structural Engineerinq CBUCK,Inc.Certifrcate of Authorization#8064 Evaluation Report "Peel & SealT,,,v, Roof Underlayment REVIEWED FOR CODE COMPLIANCE . Manufacturer: ST. LUCIE COUNTY MFM Building Products Corp. BOCC 525 Orange Street. Coshocton, Ohio 43812 (740) 622-2645 opyFlfor JIli copy- Florida orida Product Approval ` # FL 11842.2 R4 Florida Building Code 6th Edition (2017) Method: 1 - D• Category: Roofing Sub - Category: Underlayment Product: "Peel &SealTM" Description: Self-Adhered Underlayment Prepared b Facsimile of digital copy signed by P y James L Buckner,P.E. James L. Buckner, P.E.,SECB Electronically signed and sealed documents sl Florida Professional Engineer#31242 comply With the prof sjo,►;f FAC Rule e1GI5- Florida Evaluation ANEID: 1916 .�`� L. B(J •O>=NS F Project Manager: Deana Galloway `���.:• v F -.-p Report No. 17-131-PI&S-ER = * No 31242 •' (Revises 15415-P&S-ER,FL11842.1 r3) Date: 07/09/17 X70. LU %01. i(� STATE OF '•.FGOR... Contents: �S+�ONAL����� Evaluation Report Pages 1—5 ' '�J., CBUCK,Inc.dba CBUCK Engineering 2017.08.18 11:42:11 -04'00' Phone:(561)491-9927•Email:cbuck@cbuckinc-net•Website:www.cbuckinc.net Business:1374 Community Dr.,Jupiter,FL 33458•Corp/Mailing:2637 E.Atlantic Blvd,434069,Pompano Beach,FL 33062 L _ . FL#: FL 11842.2 R4 v �� Date: 07/09/17 RepoPage rt No.:2 of 51-P&S-ER CSUCK Engineering � . N Spe claltlj Structural Englmnerinq caucK,inc.Certificate of Authorization#9064 Manufacturer: - MFM Building Products Corp. 525 Orange Street Coshocton,Ohio 43812 (740)622-2545 http://www.mfmbo.com/ Product Name: "Peel&Sea"" Product Category: Roofing Product Sub-Category Underlayment Compliance Method:. State Product Approval Rule 61G20-3.005 (1) (d) ProdUCjr Description: 45-mils thick (nominally), self-adhering, foil-faced, non-reinforced membrane with rubberized asphalt,and a release liner. Roll size: 36"wide x various lengths Surface colors:Aluminum,Almond, Granite Gray&White Product Material/ Material Type: Styrene Butadiene Styrene(SBS) Standards. Material shall comply with ASTM D 1970 per Florida Building Code FBC 6th Edition (2017),Chapter 15. Substrate(s): Plywood Deck (Design of support is outside the scope of this evaluation) Installation: General Installation Instructions: • Product to be applied directly to a clean dry surface. • . Dust, dirt, ail, grease, moisture, .debris and other loose materials or contaminants must be removed prior to application. • Check that all nails in deck are not protruding and re-fasten any loose decking panels. • Prime Substrate with asphalt base primer. • Cut the membrane to appropriate length. • Peel back the release sheet,align the membrane and press into place onto roof deck. • Apply with selvedge on upward slope. • Overlap end laps a minimum of 6".Side laps must be a minimum of 3". • Apply membrane perpendicular to roof slope on slopes15,3:12 and parallel on slopes>3:12, • After installation roll entire surface with a heavy weighted roller. Roll all side and end laps. • Store product in the carton in a dry place until ready to use. Keep product out of direct sunlight. q Protect membrane from damage during construction. • Apply membrane only in fair weather when the air, surface. and membrane are at a minimum temperature of: 55" F J S j 3 FL#: FL 11842.2 R4 Date: 07/09/17 CSUCK Engineering Report No.:3 17-13 51 -ER PageSP1E=CIdifLJ Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 installation shall comply with this report, applicable code sections of FBC 6th Edition (2017) (subject to the Limitations and Conditions of Use .listed in this Evaluation Report) and man.ufacturer's installation instructions as a supplemental guide for attachment. Performance Standards: The product described herein has demonstrated compliance with: • ASTM D 1970-15a — Specification Self-adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roof Underlayment for Ice Dam Protection Standards Equivalency: The ASTM D 1970-01 standard version used to test the product meets the prescribed standards in ASTM D 1970-15a standard version adopted by the Florida Building Code 6th Edition (2017)for use as evaluated in this report. Code Compliance: The product(s) described herein have demonstrated compliance with the performance standards listed above as referenced in the current Florida Building Code. Evaluation Report Scope: This product has been evaluated in compliance with the building envelope requirements of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G203.001. Product Limitations and . Deck shall be in compliance with applicable building code. Conditions of Use: • Installation is limited to use with approved roof coverings that are mechanically fastened through the underlayment and is attached to the sheathing or rafters. • Minimum slope shall be 2:12 or greater. • Not to be applied over EPDM rubber or urethane or urethane composite insulations. General Limitations and o Scope of"Limitations and Conditions of Use"for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval" contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under"Optional Statewide Approval'. • Option for application outside"Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code".Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to comply with Florida product approval rule (FAC) 61G20-3. This evaluation report is part of the Florida Building Commission approval for the listed code J 1 T FL#: FL 11842.2 R4 Date: 07/09/17 CSUCK Engineering Page Report No.:4 - 51-P&S-ER SpecialFy Structural Engineering CBUCK,Inc.Certificate of Authorization/8054 related criteria. This report by James Buckner, P.E. and CBUCK Engineering is not .a design certification of code compliance construction submittal documentation, per FBC section 107, for any individual structure, site specific or permit design. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade&Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.0005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone-Certifications, Inc. Referenced Data: 1. ASTM D 1970=01 Test By PRI Construction Materials Technologies, Inc. (FBC Organization ID#TST 1556) Report No. MFM-005-02-01, Date: 8/29/05 2. ASTM D 1970-01 Test By PRI Construction Materials Technologies, Inc. (FBC Organization ID#TST 1556) Report No. MFM-006-02-01, Date: 8/29/05 3. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ C8UCK Engineering (FBC Organization#ANE 1916) 4. Quality Assurance Keystone Certifications, Inc. (FBC Organization ID#QUA 1824) MFM Building Products Corp. Licensee#335 S. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) FL M FL 11842.2 R4 Date: 07/09/17 �E3U�'� Engin��rinq Pagert No.:5 o51-P&S-ER SpeclaltLj StrUCturdl Engineprinq ceucx,Inc Certif�cnte of Authorization u805a MFM Building Products Corp. Product Illustrations 'c r%. Jr 4 u PeeM Sea ITM lechnical Information MFM Building Products Corp.manufactures awide range of ♦♦ PREMIUM HT innovative waterproofing products for the building industry.With more than .�. TILE Sc METAL" 57 years of field experience.MFM products are engineered for superior performance and ease of installation. DESCRIPTION PRODUCT DATA Premium HT Tile&Metall'"is a self-adhering roof underlayment composed Installation Temperature Range >50'F<250"F . of a high-grade,reinforced polyester fabric laminated to high-temperature asphalt adhesive system rated to 250"F.It also features a.fiberglass- Material Color White reinforced core.A release liner protects the adhesive and is removed Roll Size/Rolls'per Carton 36'x 67 ft-1 Roll per Carton during installation.Product features.a 3"selvedge edge to ensure a secure, monolithic seal.The surface fabric offers excellent traction for good footing Carton Weight 66 lbs and for stacking files during construction. Gross Area per Carton 200 ftz USES Cartons per Pallet 30 Premium HT is intended to be used as a whole-roof underlayment It will withstand the high temperatures created by metal roofing and bonds well TECHNICAL SPECIFICATIONS with foam adhesive systems and traditional nail-down tile roofs.It may also Property Test Method- Result be used underneath cedar shakes,and synthetic and asphalt shingles. Material Thickness ASTM D 5147 60 Mls nom. INSTALLATION Maximum Load MD ASTM D 2523/1970 >60 Ibffin-w Premium HT installs directly to wood,OSB,metal or insulated roof deck, where allowed by code.The roof deck surface must be clean and dry.It Maximum Load CMD ASTM D 523/1970 >40 Ibffin-w will adhere best to a surface primed with an MFM-approved primer. Low Temperature Flextblity ASTM D 1970 Pass Corroded metal,OSB and masonry must be primed.See website for approved primers. Thermal Stability ASTM D1204/1970 Pass • Instal in a shingle-like manner so that water flows over the seams Dimensional Stability TAS 103 Pass • Starting at the eave,unroll horizontally with the selvedge edge at the top Tear Strength MD ASTM D4073/1970 >90 Ibf • Remove 12"-18"of the protective release liner,align and stick in place Tear Strength CMD ASTM D4073116970 >55 Ibf • Continue removing the release liner by pulling from underneath the roll Vapor Permeance ASTM E 96 50.1 perms and press Premium HT into place as you go • Position the next course of Premium HT so that it will cover the selvedge Nail Sealability• ASTM D 97017349 Pass edge on the first course and install membrane Elongation MD ASTM D.2523/1970 >20% • All edge laps must be a minimum of 3'or cover the selvedge edge and Elongation CMD ASTM D 2523/1970 >25% 6'for end laps • Roll entire membrane with a targe push roller,paying special attention Adhesion to Plywood(4175"F ASTM D 903/1970 Z12 Ibf/ft-w to all overlaps and seams Adhesion to Plywood Q 40'F ASTM D 903/1970 >2 lbf/ft-w • Cover within 180 days ■ Metal drip edge,valley and wall flashings should be installed under the Accelerated Aging TAS 103 Pass Premium HT membrane Ultraviolet Resistance TAS 103 Pass ■ For vertical surfaces,it should extend up the walla minimum of 3"and Puncture Resistance TAS 103 Pass the exposed edge protected by metal flashing—Premium HT may also be installed vertically on roofs with a.very steep pitch Wind Uplift TAS 103 Pass • Depending upon the pitch,roll membrane either from the ridge or eave Tile Slippage Resistance TAS 103 Pass • Minimum slope is 3:12 pitch unless limited by local codes *Some results listed may be the test method criteria and not actual test results. ■ For valleys,roll Premium HT the entire length of the valley—lap the field Premium HT over the valley membrane a minimum of 3"prior to PRODUCT NUMBER I UPC CODE the installation of the valley metal or self-adhering flashing 36'-47201 7 25799 47201 1 RE-ROOFING OVER PREMIUM HT TILE&METAL Premium HT does not have to be removed for re-roofing.Make sure APPROVALS the original membrane is clean and smooth.If recovering with a self- Premium'HT Tile.&Metal meets the requirements of ASTM D 1970, adhering product,prime the entire roof with an MFM-approved primer TAS 103-95,Florida Building Code 11842 and Miami-Dade County before applying new membrane.Mechanically-attached undedayments approved.Product is currently being evaluated for other approvals. may be installed directly over-the existing Premium HT membrane. WARNINGS II • Premium HT must be installed in accordance with local building codes • When loading roof tiles,do not exceed a maximum stack of 8 files on 30-YEAR LIMITED WARRANTY a 6:12 pitch—loading boards may be used on-top of underlayment MFM Building Products Corp.(MFM)warrants materials to be free from • Premium HT is a vapor barrier—allow for proper roof ventilation leaks caused by defects in material or manufacturing for a period of thirty (30)years from the date of purchase when applied according to directions. • DO NOT install over EPDM or TPO rubber roofing ■ DO NOT install over silicone caulking,or uncured solvents For the most current installation Instructions,Warranties,Technical or sealants. Specifications and Approvals,visit www.mfmbp.com. • Installer is responsible for compatibility with all caulks,sealants and primers71.euraoiew:enooucrsconvl 525 Orange Street,PO Box 340,Coshocton,Ohio 43812•Tel 800-882-7663•Fax 740-622-6161•www.mfrnbp.com TDS-Premium HT 07/19. �r �9 t'R r GT META I ROOFING PPLY: Knowledge—Service-Selection: Since 199& 1-17-2020 To whom it may coaccm, 141 Coast Metal Roofing Supply 1~lorida.productapprova in section paragraph?references re-roofing applications shall be installed in accordance Oith the 2017 Florida Building Cortes Section 1507.4& 1.511 for the.re-covering ovi r evasting rgds. We approve our product over existing roof and the use of`T3ltra HT Wind&--Water Seal"under the roof covering system (optional when`there is Secondary%vater barrier existing). Sincerely, Customer.Service i- yy�'a��� €-� ,�,E'�" �Yi" �„ __ S6, COAST . METAL ROOFING SUPPLY FILE COPY Knowledge.Service R Selec•lion Since 1998 GALVALUME 25 YEAR WARRANTY IIO"T DIPPED ALUMINUM-ZINC COATED SHEET STEEL.WiTH A COATING WEIGHT OF AZ55,SOLD FOR USE AS UNPAINTED STEEL BUILDING• ROOFING AND SIDING PANELS, IF ERECTED WITHIN THE CONTINENTAL UNITED STATES, WILL NOT RUPTURE, FAIL STRUCTURALLY OR PERFORATE WITHIN A PERIOD OF 25 YEARS AND 6 MONTHS AFTER SHIPMENT FROM MILL AS A RESULT OF CORROSION CAUSED BY EXPOSURE -TO NORMAL ATMOSPHERIC CONDITIONS. We are pleased to present you,with our twenty-five(25)year limited Warranty,which is below. EXCLUDED ATMOSPHERIC CONDITIONS This limited warranty DOES NOT APPLY'to sheet exposed at any time to corrosive or aggressive atmospheric conditions.including but not limited to: I. Areas subject to saltwater marine atmospheres or to constant spraying of either salt of fresh water. 2. Areas subject to fallout or exposure to corrosive chemicals,fumes,ash,cement dust or animal waste. 3. Areas subject to water runoff from lead or copper flashings or areas in metallic contact with lead or copper. 4. Conditionslcircuntstances where corrosive fumes or condensates are generated or released inside the building. OTHER EXCLUDED SITUATIONS this limited warranty DOES NOT APPLY in the event of A.Bends less than 2T for sheet thickness 0.030"and thinner and less than 4T for sheet thickness 0.031'"and thicker. B.Slopes of the roof or sections of the roof flatter than''IA:12. C.Mechanical.chemical or other damage sustained during shipment,storage,forming fabrication or during or after erection. D.Forming which incorporates severe reverse bending or which subjects coating to alternate compression and tension. E.Failure to provide free drainage of water,including internal condensation,ftom.overlaps on all other surfaces of the sheets or panels. F..Failure to remove debris from overlaps and all other surfaces of the sheets or panels. G.Damage caused to the metallic coating by improper roll forming,scouring or cleaning procedures.) H.Deterioration of the panels caused by contact with green or wet lumber or wet storage stain caused by water damage or condensation. L Presence of damp insulation or other corrosive materials in contact with or close proximity to the panel. J.This warranty does not apply in the event of deterioration to the panels caused directly or indirectly by panel contact with fasteners.Selection of suitable long-lasting Fasteners to be used with ALUMINUM-ZINC sheet roofing and siding panels rests solely with the Buyer. - i EXCLUSIVE REMEDIES Buyer's exclusive remedy and Seller's sole liability for breach of this limited warranty shall be limited exclusively to the cost of either repairing nun-conforming panels,or at Seller's sole option,of furnishing FOB Buyer's plant sufficient sheet product to enable Buyer to fabricate replacement panels for the tion-conforming panels. LIMITATION OF DAMAGES THE LIABILITY OF SELLER SHALL NOT EX"PEND TO PERSONAL INJURY,PROPERTY DAMAGE.AND LOSS OF PROFIT. DEL-AN' OR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE FAILURE OF ANY SHEET TO CONFORM TO THE PROVISIONS OF THiS LIMITED WARRANTY. OTHER WARRANITES,INCLUDING MERCHANTABiLITh I TFIERE ARE NO WARRANTIES.PROMISES OR AFFIRMATIONS OF FACT.INCLUDING WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR j A PARTICULAR PURPOSE.OTHER THAN THOSE EXPRESSLY SET FORTH HEREIN. THE CONDITIONS OF LIABILITY,RiGHTS,OBLIGATIONS AND REMEDIES OF THE PARTIES RELATING TO CLAIMS ARISING FROM ANY.NON-CONFORMING SHEET SHALL.BE GOVERNED EXCLUSIVELY BY THE TERMS SET FORTH HEREIN. INSPECFION AND NOTICE OF CLAIM Buyer shall exercise diligence in inspection of material as received from Seller prior to utilization so as to mitigate expense involved in repairing.repainting or replacing non-conforming sheets.Claims for any breach of warranty must be made within the period of this limited warranty and within 30 days after Buyer discovered the non- conforming sheet:Buyer must give Seller a reasonable opportunity to inspect the material. DUTIES OF BUYER IN PRESENTING CLAIMS As a condition precedent to Seller's liability hereunder,Buyer must present with his claim such records so to enable Seller to establish Seller's order number.Seller';coil ( number:date of shipment by Seller and the date of installation I the font of building panels for the claimed non-conforming sheet.Buyer shall also present such evidence I` that establishes any claimed non-conformance was due to a breach of the limited warranty stated herein. 1.1 MTR4\SFERS.REPRESENTATIONS AND ASSIGNMENTS This limited warranty is extended to Buyer as the original purchaser from Seller and is non-transferable I and non-assignable.No rights against Seller shall be created by any purported transfer of assignment.nor shall any rights against Seller survive any transfer or assignment. y Buyer or its agents or representatives shall not claim,represent or imply nor permit its customers.distributors.applicators or contractors to claim,represent or imply that Y this limited warranty extends or is available to parties other than the Buyer,and to the limit of its legal right to do so,Buyer shall cause any party to cease and desist in any such misrepresentation.This condition shall constitute a material term of this limited warranty and its violation by Buyer shall excuse Seller from its obligations hereunder. WAIVER OR MODIFICATIONS OF SELLER'S RIGHTS No terms or conditions.other than those stated herein,.and no agreement or understanding,oral or written,and no course of conduct or performance,in any way purporting to modify this limited-warranty or to waive Seller's rights hereunder,shall be binding on Seller unless the same be clearly set forth in a writing that expressly refers to x this limited warranty,and is signed by the authorized representative of Seller. TERMINATION I Seller reserves the right to terminate this limited warranty,except with respect to orders which it has already accepted,upon the giving of written notice thereof ; ENTIRE AGREEMENT Jj The provisions set forth herein are in lieu of and expressly supersede any other provisions irrespective of where contained:All proposals.negotiations and representations, j i f am,made prior to or with reference hereto are merged herein. WARRANTY IS NON-TRANSFERRABLE r 1' Customer Name: Lynn Hawley Address:4707 Regina Dr. Fort Pierce,Florida.34982 . !' installer: RSS Rooting Services and Solutions Date of Installation:January 12t1,2020 1 (� Jame Purchased: October 10i1,2019 Invoice Number: 70374 i; I Color: G<alvalume Gauge:26 1 �. Ist Coast Metal Roofing Supply Authorized Signature ls1 Co Metal Rooting Supply g i 186 State Road 207,East Palatka FI 32131 , .1 Ph 386.32 .0242 Fax 386.326.4260 www.Istcoastmrs.com :1 i 1 1 �! 1 52 (1 r i. i 1 5 2 l.. 11 !� i I! l 2 f� t f �; r 9 Metal Roof Certification & Listing Program KAY Certification Report ` GEiTTIFICAT10N5.'INC. ill----�� 11030-004-KCI s06� f1.45'limekiln Road;Suite 1006 Issue Dated. - , 6/19/2018• New Cumberland,PA 17070 _ Revision Date: 6/19/2018 { www.keystonecerts.com , . Expiration Date: 6/19/2023 . REVIEWED FOR F le Copy CODE-COMPLIANCE �.. ST. L_UCIE COUNTY Construction Specifications Institute(CSI)Category: ®CC Division: 07 00 00-Thermal&.Moisture Protection Section: 07 4113-Metal Roof Panels • 2017 Florida Building Code-Building,6th Edition, 1. Program Licensee: Section 1504.3.2. • Florida Product Approval Rule 61G2G-3. Properties Evaluated: ST • Wind Uplift Resistance ' COAST This Certification Report was used to qualify METAL. R00FIN8 SUPPLY Florida Product Approval FL 24397. 1st Coast Metal Roofin Su I 4. Evaluated Roof System Description: ~ g PP y 186 SR 207 4.1. Roof Covering: Armour Loc 26 Ga. metal roof East Palatka, FL 32131 panels are cold roll-formed from minimum 26 gauge 386-325-0242 ASTM A792 Grade 50 steel sheet. The panels are http://www.lstcoastmrs.com/ aluminum-zinc alloy coated per ASTM A792 (A750),_and shall be installed in accordance with the manufacturer's � _ •.:�.a=es �-'� — -- --- - ---- —�^g�Fub`I'._-_ - - S=CgTt - p(JC� C�rwul a.uvclnlg. -- - 1�Co s MetarRoo ng uppiy's Model-�our Loc 26 ¢� Roa Deck:Arrnour-LoG26 Ga.metal roof-panels Ga. non-structural 'nailstrip standing seam metal roof are certified for use over solid or closely-spaced,nominal panels installed over plywood sheathing roof deck for 15/32".B-C 4 ply CDX.plywood sheathing complying with use in new construction and re-roofing applications. 2017 Florida Building Code, Section 2303.1.5, with a minimum slope of 2%(1/4:12). 3. Scope of Certification: 4.3. Anchorage: Armour Loc 26 Ga. metal roof This Certification Report provides technical data panels shall be fastened to the roof deck using ST substantiating that the use of the certified roof covering Fastening System ST Clip Screws#12 x 1" pancake-head and the evaluated roof systems are in compliance with wood screws (or equivalent)through the nailstrip at the following: from each end, then spaced 4-3/4" OC as specified in Table 1 and illustrated in Appendix 1, Refer to www.kaystonecerts.com to ascertain the ongoing status of this Certification Report.Approval of building products and/or materials can only be granted,by the building official having jurisdictional legal authority. Keystone Certifications,Inc.does not endorse or make warranties with respect to product performance or suitability of a product for a given use. Metal Roof Certification & Listing Program � YSTONZ Certification Report Cv_RTsFI CATsoN s. IN=. 11030-004-KCI Q �= Page 2 of 4 6.1. Wind Resistance S. Installation The allowable design uplift pressures for Armour Loc 26 Armour Loc 26 Ga.metal roof panels in new construction Ga.anchored as illustrated in Appendix 1,when tested in applications shall be installed in accordance with the accordance with the referenced standards with an 2017 Florida Building Code Section 1507.4, the applied safety factor of 2.0 are found in Table 1. manufacturer's. published installation instructions and Table 1 this Certification Report. Max Armour Loc 26 Ga. metal roof panels in re-roofing Anchor Anchor Design applications shall be installed in accordance with the Description Man'f& Pattern Uplift 2017 Florida Building Code Sections 1507.4& 1511,the Model Pressure manufacturer's published installation instructions and � „ Over At From ST Fastening this Certification Report. 15/32"4 Each End System ST 96.0 psf The manufacturer's installation instructions shall be Ply and 4-3/4" Clip Screws made available at the time of installation. If there are Plywood O.C. #12 x 1" differences between this report and the manufacturer's 7. Conditions of Use P installation instructions this report shall take cedence. Armour Loc 26 Ga. metal roof panels must be insulated - - pre ---- - -- -— - - -- -- ----- --- --_ _ 6.—Qroduct-PerformanCe _ lead,-copper-and-treated-lumber-that-contains_corrosive The performance of the Armour Loc 26 Ga. metal roof materials. panels described. in this Certification Report has been determined in accordance with: 8. Limitations of Use Armour Loc 26 Ga.metal roof panels are not qualified for • UL 580=06, Tests for Uplift Resistance of Roof use in the High Velocity Hurricane Zone (HVHZ). Assemblies. As tested & reported by the following independent Fire classification, shear diaphragm design, roof deck accredited laboratory: design & attachment to supporting members are not within the scope of this Certification Report. Laboratory Report Ref: Intertek 12151.03-450- 44-R1 Roof support framing shall comply with 2017 Florida Building Code Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading. Refer to www.keysto;ecerts.com to ascertain the ongoing status of this Certification Report Approval of building products and/or materials can only be granted by the building official having jurisdictional legal authority. Keystone Certifications,Inc does not endorse or make warranties with respect to product performance or suitability of a product for a given use. • Metal Roof Certification & Listirig Program , ( TON� Certification Report C ERl'1 Fr CA'TI ONS.1 NC. 11030-004-KCI 10612 N Page 3 of 4 2018.06..1 9. Licensed Manufacturing Facilities (� - This Certification Report is applicable only to Armour Loc 08:56:45 26 Ga. nailstrip standing seam metal roof panels -04'0-0' manufactured at the following locations: 1st Coast Metal Roofing Supply 186 State Rd 207 Aaron Shultz East Palatka, Florida 32131 Validations Manager Each licensed facility is subject to periodic inspection by . Keystone Certifications to verify conformance with Keystone Roof Covering Certification & Listing Program requirements. 10. Identification Armour Loc 26 Ga.metal roof panels represented bythis report shall be identified with Keystone. Roof Covering -_:-----Cectfication:-&-listing--Pro _ification labeling -- - - - - Illustrated-below,-to-he_appli-ed_to_individual _panels,_-_ packaging,invoicing or bills of lading:- keystonecerts com . CERTIFIED � f. 11030-004-KCI Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report.Approval of building products and/or materials can only be granted by the building official having jurisdictional legal authority. Keystone Certifications,Inc.does not endorse or make warranties with respect to product performance or suitability of a product for a given use. Metal Roof Certification & Listing Program. E,YSTON Certification Report CERT?FI CATIONS.l NC. l ----11 11030-004-KCI Page 4 of 4 Appendix 1 Note:In all cases(new construction and re-roofing),the anchors shall fully penetrate thie plywood roof deck. 18' id 40ne row of ST Fastening Systems'ST 16132"4-Ply.CDX Gip Screw 412 x 1"pancake headat Plywood Sheathing U2"from each end and max 4314"O.C. Refer to www.keystonecerts.com to ascertain the ongoing status of this Certification Report.Approval of building products and/or materials can only be granted by the building-official having jurisdictional legal authority. Keystone Certifications,Inc.does not endorse or make warranties with respect to product performance or. suitability of a product for a given use. j—�--` Metal Roof Certification & Listing Program YYSTO, Certification Report ' ER7'IFiCAT10N5.INC. • • +• l---jam 11030-004-KCI f145.I.imekiln Road,Suite 1006-: Issue Dated:. 6/19/2018 New Cumberland,PA 17070 Revision Date:. 6/19/2018 wwuv.keystonecerts.com Expiration.Date:' •6/19/2423 Certificate Revisions Rev# Date Description 0 6/19/2018 Initial issuance. i I� Refer to www.kevstonecerts.com to ascertain the ongoing status of this Certification Report.Approval of building products and/or materials can only be granted by the building official having jurisdictional legal authority. Keystone Certifications,Inc.does not endorse or make warranties with respect to product performance or suitability of a product for a given use. V..5 � I i II • I 1 D=Slgn Env.topelD:EAABBBAS•E1394DOD•8995-CC3BF2C2AIC1 � , i *** STANDING SEAM *** n 16, V 16* 1' 16' Panel Cutting List Summary X 16:.1• 36' r _ _ I 16, t• t, t, Matetiat lsl Cbast MRS,PA•ISS•HD•18.24,Amx a Loc,Galvaft%26.00,16.0 y 7b' t• 16" r o' 16' 1' 1142'11",1/2T1(r,28/17'1",28/161x',18/151", 1/1611".1/1510", 16,.1. k' I. 11168",1115'T', 21155",1114'S",1114'4", 2/14"1",211311",1/12'11" 1 •_� e t b: t 1/1Z10",2/12'T',3/12"5,1112'3",1/11'V',1111'4".2/111" 3/19111j. 1/109,1/10',1/910,1/98,1/9'7", 3/95,.10/89",1/8'T',1/86, t 4 V.7",2/3' Indlo' 1218'5", 2/8`4`; 2/8'•2", 1151",2/7'11';4C/'S', VT1".1/T,3/510", 216'8". 2/6'5',4/5,1715'9",115•T',115'5',215'8',1/5'4", 215'2", 7/5'1",2/4'11", 714'5',114'3,114'1",114, 21311", 3/31Q, �s ! r t e to' tr Io '11' ' E , § __ 2/38", 1/3' a ^°•, 7• 1 ?•..1'1' a'5' PanelACCes=in 8'9' - 6'S' 6'5' -to --- - B•5• Fasteners Mmfmum Panel Length Bteakdown B 9' ,r :•l to� �-.:9,.. .' . 1/4711'above made up of 7/3, 1/710,1177,172'6",2/75,3/Z4".1l2`12". o toyN. ti e 5 1/27'10 abovamadeupcf1/2'7',112'1", 217,7/1'5',1/1'4",1/11",3/0'11", Wr 9N R 6 o b b b o IT 1' ..10. Z. Total Panel Length:2390'.6" Selected Panel.Lenglhd23 5' I '^ 6 J7 r tt ID' IB TotalPanelAl Area:rea:3l07.34t Selected Pane3187. wt IT 1' 185 i` 1 .17 5 1' •S 1 Total Roof Awe:2980.7 sglt Panel Atea/Roof Area(Estimated Waste):6.46% IT 1 17. 1' PanelAllowances;Used:<DEFAULT> IT r 1.• 1"�:. IT 1' ,r_17' 1'•: 17. 1' 171' oe.ep..�yt Expod to Ro'llf. r Delete 17 •a•T T T.P'' P O.P P N N A S• "iiy,{lypµ{Ci.. Eltpolt CSV (3tarlge Maty I OK 1 '� �In ro In rr 0' 10/7/2029 7 I ' I - i ,