Loading...
HomeMy WebLinkAboutProduct Approval MIAMI DADS COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F 11786)315-2599 NOTICE OF ACCEPTANCE (NOA) Tam-MJfflWdR—ft.P-0y/eWn0MJ NCI Group Inc. 14031 West Hardy Houston,TX 77060 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Ddde County Product Control Section (in Miami-Dade County)and/or the AHJ(m areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:5V Crimp Panel RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable Building Code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. UJ INSPECTION:A copy of this entire NOA shall be provided to the usq by thdrnanufacturer or its distributors and shall be available for inspection at the job site at the request of the Building OfficiA This NOA revises and renews NOA#11-0810.10 and consists of pages I through 7. The submitted documentation was reviewed by Gaspar J Rodriguez. 45 4 ADFOR- CODE COMPLIANCE ST. -LUCIE COIF TY OCC REVIEWED OC REVIEWED FOR NOA No.: 154629.04 CODE COMPLIANCE Expiration Date:02/26121 ST. LUCIE COUNTY Approval Date:10/22/15 page I of 7 BOCC ROOFING A.SSEMRLY APPROVAL: Category: Roofing : :Sub-Category: Non-Structural Metal Roofing katerishw • Steel Fire Cie"ifiention: See General Limitations#1 Maximum:Desien Pressure: -146 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions Test Specifications Product Description 5V Crimp Roof Panel Length:various TAS 125 Corrosion resistant, Width:261/s" galvalume,performed, (Coverage width: 24") standing seam,coated,pre- Thickness : 0.0217 finished,metal panels. MANUFACTURING LOCATION: 1. Houston,TX 2. Adel,GA EVIDENCE SUBNMTED: Test Agency Test Identifier Test Name/Reyort Date Farabaugh Engineering and T139-08 TAS-100 03/13/08 Testing,Inc. Force Engineering& 07-293T-06A-C TAS-125 01/16/06 Testing,Inc. Underwriters Laboratories, File R8116 Standard Requirements for Metal 06/97 Inc Project 97RT4520 Roofing Systems Miami-Dade County TAS-125 Center for Applied MTS Job No.257829 Wind Driven Rain 10/96 Engineering, Inc. Miami-Dade County TAS-100 Underwriters Laboratories, File R11609 UL 580 02/02 Inc. Project 01RT10456 TAS-125 MBC-003-02-01 Wind Driven Rain 11!01 PRI AsphaltTecluiologies, TAS 100 Inc. i N0ANo.:15-0629.04 ExpirationDate,02126121 A4gtoval Dat-p ge 22017^`—_ CD1lN�'� 1 � L SYSTEM DESCRIPTION SYSTEM A-1: "5V-Crimp"26 Ga. Metal Panel Deck Type: Wood,Non-insulated Deck Description: 1-9/32"or greater plywood or wood plank. Slope Range: 2":12"or greater Maadmum Uplift The maximum allowable design pressure for the 24"wide panel shall be Pressure: —90 psf. (See General Limitation#2) Deck Attachment: In accordance with applicable Building Code,but in no case it shall be less than #6 x 2"screws or 8d common annular ring shank nails spaced at 6"o. c. In re- roofing,where deck is less than 14/32"thick(minimum 15/32")the above attachment method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be a ASTM D 226 Type Il installed with a minimum 4"side-laps and 6"end-laps. Underlayment shall be fastened with corrosion resistant tin-caps and 11/4"annular ring-shank nails, spaced 6"o.c. at all laps and two staggered rows 12"o.c.in the field of the roll. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with NCI Group's current published installation instructions. Fire Barrier Any approved fire barrier having a current NOA. Refer to a current fire directory Board: listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation# 1. Metal Panels and Install the "5V-Crimp Panels" including flashing penetrations, valleys, and Accessories: accessories in compliance with NCI Group's current published installation instructions and in compliance with the minimum requirements detailed in Roofing Application Standard RAS 133. NCI Group 115V-Crimp Panels" shall be installed with a minimum#14 corrosion resistant fasteners with sealing washers of sufficient length to penetrate 5/1611through the sheathing. Fasteners shall be spaced in accordance with fastener detail herein as follows: 1. Panel side ribs shall be fastened along side of the panel inside ribs,one fastener at the overlap and one fastener at the underlap. Center panel rib shall be fastened with two fasteners at the each side of center panel. 2. All fasteners at center rib,underlap rib,and overlap rib shall be spaced at a maximum of 36 inches o.c.parallel to the roof slope. See Detail A herein. NOA No.:1S-0629-04 Expiration Date:02126121 �ps,DECotM't� Approval Uate:1012211S page 3 of I 5V CRIMP PANEL DETAIL A 12" y 0.5" 24"COVERAGE PANEL OVERLAP FASTENER w/WASHER . . . . . . . . . . SUBSTRATE PANEL UNDERLAP J FASTENING PATTERN AT FIELD, SAVE & RIDGE OF PANEL Fastener w/Washer Spaced at 36"o.c. 5V Panel NOA No.:I5-0629.04 Expiration Date-02126121 Approval Date* 10/22115 page 4 of 7 SYSTEM A-2: i°5V-Crimp"26 Ga.Metal Panel Deck Type: Wood,Non-insulated Deck Description: 19/32"or greater plywood or wood plank. Slope Range: 2":12"or greater Maximum Uplift Pressure: See Table B Below.(See General Limitation#2) Deck Attachment: In accordance with applicable Building Code,but in no case it shall be less than #6 x 2"screws or 8d common annular ring shank nails spaced at 6"o.c. In re-roofing,where deck is less than 14/32"thick(minimum 15/32")the above attachment method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be a ASTM D 226 Type II installed with a minimum 4" side-laps and 6"end-laps. Underlayment shall be fastened with corrosion resistant tin- caps and P14"annular ring-shank nails,spaced 6"o.c.at all laps and two staggered rows 12"o.c.in the field of the roll. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with NO Group current published installation instructions. Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation# l- Metal Panels.and Install the "SV-Crimp Panels" including flashings penetrations, valleys, and accessories Accessories: in compliance NO Group's current published installation instructions and in compliance with the minimum requirements detailed in Roofi$g Application Standard RAS 133. NO Group"5V-Crimp Panels"shall be installed with a minimum#10-15 corrosion resistant fasteners with sealing washers of sufficient length to penetrate 3/16"through the sheathing. Fastener shall be spaced at a maximum of 12"o.c.perpendicular to the slope, in rows spaced as noted below in Table B running parallel to the slope of the roof. Fastener shall be placed at high points of panel ribs. See Detail B herein. TABLE B MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corner' Malamum Pressures —74.75 PSF —146 PSF 11auimnm Fastener S 1&0 24"OC 12"OC 1. EjdmolpAon shall not be allowed NOA No.:15-0629.04 Expiration Date:02126121 N ,ui Approval Date:10/22/15 page 5 of 7 5V CRIMP PANEL DETAIL B 12" 0.5" 24"COVERAGE PANEL OVERLAP —FASTENER wl WASHER SUBSTRATE PANEL UNDERLAP FASTENING PATTERN At FIELD, SAVE &RIDGE OF PANEL #10-15 Fastener-wl Washer spaced as noted in Table B. astener Spacing 5V Panel as perTable B Spacing as per Table B NOA No.: 15-0629.04 Expiration Date:e2/26121 MAM Approval Date:10122i15 page 6 of 7 LIMITATIONS 1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones(i.e.field, perimeters,and corners). Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e.perimeters,extended comers and corners). 3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in Roofing Application Standard RAS 133 4. All panels shall be permanently labeled with the manufacturer's name and/or logo,and the following statement: "Miami Dade County Product Control Approved" or with the Miami-Dade County Product Control Seal as seen below. All:.lips shall be permanently labeled with the manufacturer's name and/or logo,and/or model. MiAMI•�ADE O�1"M ,...O ,D S. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 15-0629.04 Expiration Date:02/26121 Approval Date, 10/22/15 •••• page 7of7 K Gertificafe ofAuthamation Na. 29824 CREE17520 Edinburgh Drive Tampa,FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,C EDITION(2017) Manufacturer; TAMKO BUILDING PRODUCTS, INC. Issued October 19, 2017 P.O.Box 1404 Joplin,MO 64802 CO TRACTOR COPY (417)624-6644 I► 1\I httmilwww.tamko.com Quality Assurance; UL LLC(QUA9625) REVIEWED FOR SCOPEIn Category: Roofing -�-� L `.r E COUNTY Subcategory: Underlayments Code Sections: 1507.1.1 BOCC Properties: Physical properties PRODUCT DESCRIPTION TAMKOS ASTM State ASTM D 6380,Class M,Type 11 underlayment constructed from organic felt saturated Surfaced Roll!Roofing with asphalt and coated on both sides with asphalt and surfaced with granules. TAMKO@ ASTM Tile ASTM D 6380, Class M,Type 11 underlayment constructed from an organic felt saturated Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules. TAMKO@ Master ASTM D 6380,Class S,Type tV underlayment constructed from an organic felt saturated Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For use in non-HVHZ oniv. TAMKOV MolstLre Self-adhered, ASTM D 1970, fiberglass reinforced, modified.bitumen sheet membrane Guard@ with a mineral surfacing and a removable release film on the adhesive side and removable selvedge release tape. TAMKO@ No.15 ASTM ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt TAMKO@ No.15 UL ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt TAMKO@ No.30 ASTM ASTM D 226,Type It underlayment constructed from a non-perforated organic felt that is AsptMlt Saturated saturated with asphalt r an ic Felt TAMKO®No.30 UL ASTM D 226,Type it underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt Organic Felt TAMKO*TW Metal and Self-adhered,flexible,ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side. TAMKO9 TW Self-adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a Undedayment polymer film on the surface and a removable release film on the adhesive side. FL12328-R8 page 1 of 4 Tiap14001.4 approval under Rule 811320-3. The manutacturer shall notify CREEK This evaluation report is Provided for State of Florida product Technics{Services.LLC of any product changes or quality assurance changes throughout the duration for which this report is valid- product ali . _— This evaluation report does not express not imply warsantil.installation,recommended use,or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODCUTS,INC. CREEK TAMKO Underlayments TECHNICAL SERVICES, LLC TAMKO@)TAM-FELT Alternate to ASTM D 226,Type I and Type 11 underlayment constructed from a non- perforated organic felt that is saturated with asphalt. APPLICATION METHOD Installation shall be in accordance with the published manufacturers installation instructions, the FSC, and the requirements below. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to undedayment application. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting joints. The minimum application temperature shall be 50°F except as follows: a) The minimum application temperature of TAMKO@)TW Metal and 1-fle Underlayment and TAMKO@ 1W Undedayment shall be 40*F. b) The minimum application temperature of TAMKO@)Moisture Guard(&shall be 35°F. The minimum roof slope shall be in accordance with FBC requirements except as follows: a) The minimum slope of TAMKO@ ASTM Slate Surfaced Roll Roofing shall be 2:12. Underlayments shall be exposed in accordance with the manufacturer's recommendations, but it no case shall exposure exceed 30 days. Exception. TAMK08 TW Metal and-rile Underlayment may be exposed for a maximum 90 days. Self-adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ. All roof coverings shall be mechanically fastened through the underlayment to the roof deck. Allowable Roof Coverings: Metal Roof Mineral WWW Asphalt Panels and Surfaced Roll Shingles and Siake Clay and Underl"ment Shingles- Shingles Roofing Shakes Shin les i Conenift Tile TAMKO@ ASTM Slate Y1 N N N N Y Surfaced Roll Roofing TAMKO0 ASTM Tile N N N N N Y Underlayment TAMKOV Master Smooth Y1 N N N N N TAMKO@ Moisture Guard@) Y N N N N N TAMKOV No. 15 ASTM Asphalt Saturated Organic Y Y Y Y2 N N Felt TAMKOS No.15 UL Asphalt Y Y Y y2 Y N Saturated Organic Felt ­"ted Organic 0. 0 ASTM Asphalt Saturated Organic Y Y Y Y Y Saturated e it ft 0Y OS TAMKOS No.30 UL—Asphalt Y N Saturated 4 W 0 al Y Y Y N Saturated Organic Felt Metal and rile Y Y N N N Y T =ym;TW Zndiie TAMKov Tw Undenayment Y Y N N TAMKO@ TAM-FELT Y N N Notes: i)Open valley applications per 1507.2.9.2 2)wood shingles only Page 2 of 4 FL12328-R8 ....... .. ................. i—all—no�ftfiCREEK TSP14001.4 The martulactule!s' This evaluation report is provided for State 01Florida product approval under �tuie 61G20-3- th port is va LLC of any product changes or quality assurance changes throughout the duration for which Is re "d' Technical Services, imply warranty,Installation,recommended use,or other product attributes that are not This evaluation report does not express no' specifically addressed herein. TAMKO BUILDING PRODCUTS,INC. CREEK TAMKO Undwtayments TECHNICAL SERvicEs, LLC Umtunoms I) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance in not within scope of this evaluation. 3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacUrer's published application Insuvictions. Where discrepancies exist between these sources. the more restrictive and FBC compliant installation detail shall prevail. 4) Contact the manufacturer when installing at temperatures below the minimum application temperature. 5) Unless otherwise stated,the minimum roof slope shall be in accordance with FBC requirements. 6) All underlayments shall be installed with the roll length parallel to the eave,starting at the eave,and lapped in successive courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturees application instructions. 7) The underlayment may be used as described in other current FBC product approval documents. 8) The undeflayment shall not be installed over existing roof coverings. 9) Contact the manufacturer regarding specific exposure limits for each underlayment 10) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies(TST6049) TAP-192-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-193-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-214-02-01 ASTM D 4869 2016 PRI Construction Materials Technologies(TST6049) TAP-215-02-01 ASTM D 226 2009 PFU Construction Materials Technologies(TST6049) TAP-216-02-03 ASTM D 6380 2003(2013) PRI Construction Materials Technologies(TST6049) TAP-217-02-DIREV ASTM D 6380 2003(2013) PRI Construction Materials Technologies(rST6049) TAP-218-02-01 ASTM D 226 2009 PRI Construction Materials Technologies(TST6049) TAP-21 9412-01 ASTM D 226 2009 PF;U Construction Materials Technologies(TST6049) TAP-220-02-01 ASTM D 6380 2003(2013) PRI Construction Materials Technologies(TST6049) TAP-222-02-01 ASTM D 4869 2016 PPJ Construction Materials Technologies(TST6049) TAP-245-02-01 TAS 103 1995 ASTM D 4798 2011 PRI Construction Materials Technologies(TST6049) TAP-311-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) TAP-319-02-01.1 ACC 188 2012 PRI Construction Materials Technologies(TST6049) TAP-387-02-01 ASTM D 1970 2EP 1 Sa PRI Construction Materials Technologies(TST6049) TAP-388-02-01 ASTM D 1970 2015a UL LLC(TST9628) 13CA12269 ASTM D 226 2009 TBP14001.4 FL12328-R8 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this reporl:is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. a TAMKO BUILDING PRODCUTS,INC. CREEK TAMKO Undertayments TECHNICAL SERviCES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,6Edition(2417)as evidenced in the referenced documents submitted by the named manufacturer. `ttJ111lllllt Wf R. p'r-*, ......., R, 2017.10.19 • No 74421 12:15:58 -� Iz Z -041001 � 3 STATE OF :4U: i1'.�'�•••;�4p P.:�2. Zachary R.Priest, P.E. ''� irslCaRegistration No.740 NpL , OrganFlorida zation No.ANE9641 21 filllll� CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services.LLC is not owned.operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product END OF REPORT TBP14001.4 FL12328-R8 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. i