HomeMy WebLinkAboutProduct Approval - tile ' 3/11/2019 Florida Building Code Online
Busihesss 1 1 . • 0 . 0
Fla
BCIS Home I Log In User Registration I Hot Topics I Submit Surcharge Stats&Facts Publications I Contact Us I BCIS Site Map I Links I Search i
FloridPr
Product Approval
pp�yy��s� ® USER:Public User -
&ArIeWW
Product Approval Menu>Product or Application Search>Application List>Application Detail
• • FL# FL28328-RO RECEDED
Application Type New
Code Version 2017 JAN 14 ?0?_0
Application Status Approved
ST. Lucie County,Permitting
Comments
Archived O
Product Manufacturer Boral Roofing LLC
Address/Phone/Email 7575 Irvine Center Drive
Irvine,CA 92618
(801) 380-6091
robinanderson@boral.com
Authorized Signature Robin Anderson
robinanderson@boral.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roofing Tiles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
O Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity PRI Construction Materials Technologies, LLC.
Quality Assurance Contract Expiration Date 11/03/2020
Validated By Locke Bowden P.E.
OO Validation Checklist- Hardcopy Received
Certificate of Independence FL28328 RO COI BOR18003 2017 FBC Eval Boral Tiles Final.pd
Referenced Standard and Year(of Standard) Standard Year
ASTM C 1492 2003
TAS 100 I I,�I�� 1995
TAS 101 11 1995
TAS 102
TAS 102(A) �'EVVE® F5
OR
TAS 112 ,00E ■v'
® PLI tOE
Equivalence of Product Standards �'�'• ��C;I E COUNT_D—
Certified By
Sections from the Code File BOCC Cop
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquiObYx6FhH7l l Lsy6vf2fOET98zvZOgRbeQ78kgVkWLg%3d%3d 1/3
3/11/2019 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 10/15/2018
Date Validated 10/16/2018
Date Pending FBC Approval 10/24/2018
Date Approved 12/11/2018
Date Revised 02/22/2019
Summary of Products
FL# Model,Number or Name Description
28328.1 Barcelona 900 (Lake Wales) ASTM C 1492/TAS 112 type 1a, high profile concrete tile
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL28328 RO II BOR18003 2017 FBC Eval Boral Tiles Final.pdf
Approved for use outside HVHZ:Yes Verified By: Zachary R. Priest PE-74021
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See evaluation report for limits of use. FL28328 RO AE BOR18003 2017 FBC Eval Boral Tiles
Final.pdf
Created by Independent Third Party: Yes
28328.2 Bermuda (Okeechobee) ASTM C 1492/TAS 112,type 3a,flat concrete tile
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL28328 RO II BOR18003 2017 FBC Eval Boral Tiles Final.pdf
Approved for use outside HVHZ:Yes Verified By: Zachary R. Priest PE-74021
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See evaluation report for limits of use. FL28328 RO AE BOR18003 2017 FBC Eva] Boral Tiles
Final.pdf
Created by Independent Third Party: Yes
28328.3 Estate"S" (Okeechobee) ASTM C 1492/TAS 112 type lb, low profile concrete the
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL28328 RO II BOR18003 2017 FBC Eva] Boral Tiles Final.pd
Approved for use outside HVHZ:Yes Verified By: Zachary R. Priest PE-74021
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other: See evaluation report for limits of use. FL28328 RO AE BOR18003 2017 FBC Eva[Boral Tiles
Final.pdf
Created by Independent Third Party: Yes
28328.4 Galena Spanish "S" (Okeechobee) ASTM C 1492/TAS 112 type 2a, high profile concrete tile
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL28328 RO II BOR18003 2017 FBC Eva] Boral Tiles Final pdf
Approved for use outside HVHZ:Yes Verified By: Zachary R. Priest PE-74021
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See evaluation report for limits of use. FL28328 RO AE BOR18003 2017 FBC Eval Boral Tiles
Final.pdf
Created by Independent Third Party:Yes
28328.5 Plantation (Okeechobee) ASTM C 1492/TAS 112 type 3a,flat concrete tile
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL28328 RO II BOR18003 2017 FBC Eval Boral Tiles Final pdf
Approved for use outside HVHZ:Yes Verified By: Zachary R. Priest PE-74021
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See evaluation report for limits of use. FL28328 RO AE BOR18003 2017 FBC Eval Boral Tiles
Final.pdf
Created by Independent Third Party:Yes
28328.6 Saxony 900 Slate,Shake and Split ASTM C 1492/TAS 112,type 3a,flat concrete tile
Shake(Lake Wales)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL28328 RO II BOR18003 2017 FBC Eva[ Boral Tiles Final pdf
Approved for use outside HVHZ:Yes Verified By: Zachary R. Priest PE-74021
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See evaluation report for limits of use. FL28328 RO AE BOR18003 2017 FBC Eval Boral Tiles
Fina].pdf
Created by Independent Third Party:Yes
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqujObYx6FhH7ll Lsy6vf2fOET98zvZOgRbeQ78kgVkWLg%3d%3d 2/3
3/11/2019 Florida Building Code Online
28328.7 Spanish"S" Nuevo(Lake Wales) ASTM C 1492/TAS 112 type 2a, high profile concrete tile
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL28328 RO II BOR18003 2017 FBC Eval Boral Tiles Final.pdf
Approved for use outside HVHZ:Yes Verified By: Zachary R. Priest PE-74021
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See evaluation report for limits of use. FL28328 RO AE BOR18003 2017 FBC Eval Boral Tiles
Final.pdf
Created by Independent Third Party: Yes
28328.8 Villa 900 (Lake Wales) ASTM C 1492/TAS 112 type lb, low profile concrete tile
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL28328 RO II BOR18003 2017 FBC Eva[ Boral Tiles Final.pdf
Approved for use outside HVHZ:Yes Verified By: Zachary R. Priest PE-74021
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See evaluation report for limits of use. FL28328 RO AE BOR18003 2017 FBC Eva[ Boral Tiles
Final.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy tatement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
Credit Card
Safe
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqujObYx6FhH711 Lsy6vf2fOET98ZVZOgRbeQ78kgVkWLg%3d%3d 3/3
CREEK
Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE EP EDITION(2017)
Manufacturer: BORAL ROOFING LLC Issued February 19,2019
7575 Irvine Center Drive
Irvine, CA 92618
(800) 669-8453
www.boralamerica.com
Manufacturing Plants: Lake Wales, FL
Okeechobee, FL
Quality Assurance: PRI Construction Materials Technologies(QUA9110)
SCOPE
Category: Roofing
Subcategory: Roofing Tiles
Code Sections: 1507.3.5, 1507.3.7, 1523.6.5, 1523.6.5.2, 1523.6.5.2.2, 1523.6.5.2.3
Properties: Physical Properties,Attachment Requirements,Wind Driven Rain, Static Uplift
Resistance
REFERENCES
Eniily Report No. Standard Year
American Test Lab of South Florida Inc(TST3782) RT0201.01-19 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0130.01-14 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0426.01-14 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0615.02-11 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0615.03-11 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0615.04-11 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0617.02-16 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0617.03-16 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0617.04-16 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0623.04-14 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0624.04-14 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0624.05-14 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT1210.02-15 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT1210.03-15 TAS 112 1995
ASTM C 1492 2003(2009)
Miami-Dade BCCO(CER1592) 14-0408.06 FBC(HVHZ) 2017
Miami-Dade BCCO(CER1592) 14-0416.12 FBC(HVHZ) 2017
Miami-Dade BCCO(CER1592) 15-0721.04 FBC(HVHZ) 2017
Miami-Dade BCCO(CER1592) 16-0112.07 FBC(HVHZ) 2017
Miami-Dade BCCO(CER1592) 16-0112.08 FBC(HVHZ) 2017
Miami-Dade BCCO(CER1592) 18-0509.15 FBC(HVHZ) 2017
Miami-Dade BCCO(CER1592) 18-0509.16 FBC(HVHZ) 2017
Miami-Dade BCCO(CER1592) 18-0509.17 FBC(HVHZ) 2017
BOR18003.1 FL28328-Rl Page 1 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
G RE E BORAL ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES, LLC
Enti Report No. Standard Year
Tile Roof Institute Membership Confirmation TAS 100 1995
TAS 101 1995
TAS 102&102(A) 1995
BOR18003.1 FL28328-R1 Page 2 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK BORAL ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
Bermuda (Okeechobee)
Profile/Description: ASTM C 1492,TAS 112 Type 3a,flat profile, interlocking,class III concrete roof tile
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 16"x 10"
I 16-
1-1/4
10'
1.
'16' _I
f
2`
10,
Figure 1. Bermuda
Plantation (Okeechobee)
Profile/Description: ASTM C 1492,TAS 112 Type 3a,flat profile, interlocking,class III concrete roof tile
Allowable Applications: For mechanically fastened(direct deck or batten), mortar set or adhesive set applications
Dimensions: 16-1/2"x 13"
-16--1/114
13�
Figure 2. Plantation
BOR18003.1 FL28328-R1 Page 3 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK BORAL ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES, LLC
Saxony 900 Slate, Shake and Split Shake (Lake Wales and Okeechobee)
Profile/Description: ASTM C 1492,TAS 112 Type 3a,flat profile, interlocking, class III concrete roof tile
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 17"x 13"x 1-5/32"(Slate)or 1-9/32"(Shake and Split Shake)
NAII,HOLES
1-5/32"(Slate)
17" COVERLOCK
13"
UNDERLOCK
Figure 3. Saxony 900 Slate
NAII.HOLES
1-9/32"(Shake)
17"
13"
Figure 4. Saxony 900 Shake
NAIL HOLES
1-9/32"(Shake)
17" 13"
Figure 5. Saxony 900 Split Shake
BOR18003.1 FL28328-R1 Page 4 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
CREEK BORAL ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES, LLC
Estate "S" (Okeechobee)
Profile/Description: ASTM C 1492,TAS 112 Type 1b, low profile, interlocking,class III concrete roof tile
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 16-1/2"x 13"
Nail Holes
•
•
Figure 6. Estate
Villa 900 (Lake Wales)
Profile/Description: ASTM C 1492,TAS 112 Type 1 b, low profile,interlocking,class III concrete roof tile
Allowable Applications: For mechanically fastened(direct deck or batten), mortar set or adhesive set applications
Dimensions: 17.0"x 13"x 2-1/8"
Mats holes
•12",
1" J•-I 4�—11/20
+G► _B
Overlock
218"
17" j
UnderloCk �t-
13"
Figure 7. Villa 900
BOR18003.1 FL28328-R1 Page 5 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
C RE E K BORAL ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES, LLC
Barcelona 900 (Lake Wales)
Profile/Description: ASTM C 1492,TAS 112 Type 1 a, high profile, interlocking,class III,'S'shaped concrete
roof tile
Allowable Applications: For mechanically fastened (direct deck or batten), mortar set or adhesive set applications
Dimensions: 17"x 13"x 3-5/8"
NAIL HOLES
OVERLOCK
3 M"
17"
13"
:.
UNDERLOCK
Figure 8. Barcelona 900
Galena Spanish "S" (Okeechobee)
Profile/Description: ASTM C 1492,TAS 112 Type 2a, high profile, interlocking, class III 'S'shaped concrete
roof tile
Allowable Applications: For mechanically fastened (direct deck), mortar set or adhesive set applications
Dimensions: 17"x 10"x 2.7"
Fastener Holes
17"
10"
Figure 9. Galena Spanish "S"
BOR18003.1 FL28328-R1 Page 6 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK BORAL ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES, LLC
Spanish "S" Nuevo (Lake Wales)
Profile/Description: ASTM C 1492,TAS 112 Type 2a, high profile, interlocking,class III 'S'shaped concrete
roof tile
Allowable Applications: For mechanically fastened (direct deck or batten),mortar set or adhesive set applications
Dimensions: 17"x 9-3/4"x 2-27/32"
Fastener Holes
17"
9-3/4"
Figure 10. Spanish "S" Nuevo
APPLICATION METHOD
Installation „
Limited to slopes 3:12 or greater in the HVHZ; Outside the HVHZ, shall be in accordance
Slope: with the recommendations of the FRSA/TRI Florida High Wind Concrete and Clay Roof
Tile Installation Manual, Fifth Edition Revised or RAS 118, RAS 119, or RAS 120, as
applicable.
Solid or closely fitted min. 15/32-inch plywood sheathing for new and existing construction
Roof Deck: at max. 24 in.span; In the HVHZ, new construction shall be min. 19/32 in. plywood at max.
24 in.span; Designed by others in accordance with FBC requirements.
Underlayment: Installed in accordance with FBC requirements. In the HVHZ, the minimum underlayment
shall be installed as described in RAS 118, RAS 119,or RAS 120,as applicable.
BOR18003.1 FL28328-R1 Page 7 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GREEKBORAL ROOFING LLC
(� Concrete Roof Tiles
TECHNICAL SERVICES, LLC
Data for°Attachment Calculations for Dlrectryto Deck Applications
Aerodynamic
Nominal UVeight(W)ands Restoring Moments'due to,G (ft-Ibf)
Multipliers
:Dimensions(I:x w) s Direct Deck
Roof Tile .* l�(ft )
-.,Direct Deck .
W(Ibf) -"1 (ft) w(ft). aApplication,. 3 12'; ' 4":12 '5 12" 6':12 ` >T 12 '�•
Bermuda 9.7 1.33 0.833 0.205 6.97 6.86 6.71 6.54 6.35
Plantation 11.6 1.375 1.08 0.289 7.79 7.67 7.52 7.32 7.04
Saxony 900 10.9 1.417 1.08 0.315 7.62 7.5 7.34 7.16 6.95
Estate"S" 10.0 1.375 1.08 0.289 6.74 6.64 6.50 6.33 6.14
Villa 900 10.9 1.42 1.08 0.315 7.62 7.50 7.34 7.15 6.95
Barcelona 115 1.417 1.08 0.301 7.00 6.90 6.76 6.60 6.42
900
Galena 8.5 1.42 0.833 0.235 6.13 6.03 5.89 5.74 5.57
Spanish"S"
Spanish"S" 8.95 1.417 0.8125 0.233 5.93 5.83 5.70 5.56 5.39
Nuevo
Data'for Attachment'Calculations for Batten Applications
Aerodynamic` '
Nominal Weight(W)and Res_Poring MomentsLLdue to Gravity-M9(ft-Ibf)
Multipliers
Dimensions(I x w) a Direct Deck
Roof Tile \_(ft,:)
W' Ibf Batten
( ) I{ft) w(ft} 3 12 4":12 5 12" 6:12 >7"-12A
pplications
Bermuda 9.7 1.33 0.833 0.189 6.53 6.43 6.29 6.14 5.97
Plantation 11.6 1.375 1.08 0.267 6.85 6.75 6.61 6.44 6.26
Saxony 900 10.9 1.417 1.08 0.291 - 6.61 6.48 6.31 6.13
Estate"S" 10.0 1.375 1.08 0.267 5.91 5.82 5.70 5.56 5.40
Villa 900 10.9 1.42 1.08 0.291 - 6.56 6.42 6.26 6.08
Barcelona
900 11.5 1.417 1.08 0.286 6.19 6.19 6.06 5.92 5.76
Spanish"S"
Nuevo 8.95 1.417 0.8125 0.215 5.30 5.21 5.09 4.96 4.82
BOR18003.1 FL28328-R1 Page 8 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
G R E E BORAL ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES, LLC
Attachment Resistance Expressed as a Moment for Mohanically.`I=astened Applications 3
Tile Fastener, `Mr
Roof Tile -
�
Direct Deck: Direct Deck r
Type Count. - Size` Sh' Clip: (min. 15/32" (min': 19% 32" Battens
Plywood};.., plywood).,- • ,.. ;
Nail 2 10d Ring N/A 30.9 38.1 17.2
Nail 1 10d Smooth N/A 7.3 9.8 4.9
or Screw
Nail 2 10d Smooth N/A 14.0 18.8 7.4
or Screw
Screw 1 #8 N/A N/A 30.8 30.8 18.2
Bermuda, Screw 2 #8 N/A N/A 51.7 51.7 24.4
Plantation or
Saxony 900 Nail 1 10d Smooth Field 24.3 24.3 24.2
or Screw
Nail 1 10d Smooth Eave 19.0 19.0 22.1
or Screw
Nail 2 10d Smooth Field 35.5 35.5 34.8
or Screw
Nail 2 10d Smooth Eave 31.9 31.9 32.2
or Screw
Nail' 2 10d Ring N/A 50.3 65.5 48.3
Nail 2 10d Ring N/A 27.8 37.4 28.8
Nail 1 10d Smooth N/A 8.8 11.8 4.1
or Screw
Nail 2 10d Smooth N/A 16.4 21.9 7.1
or Screw
Screw 1 #8 N/A N/A 25.8 25.8 22.9
Estate ,S,,2' Screw 2 #8 N/A N/A 47.1 47.1 49.1
Villa 900
Nail 1 10d Smooth Field 24.3 24.3 24.2
or Screw
Nail 1 10d Smooth Eave 19.0 19.0 22.1
or Screw
Nail 2 10d Smooth Field 35.5 35.5 34.8
or Screw
Nail 2 10d Smooth Eave 31.9 31.9 32.2
or Screw
Estate"S" Nail' 2 10d Ring N/A 43.0 67.5 50.9
3
1
1
I
Continued on following page j
BOR18003.1 FL28328-R1 Page 9 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
1
CREEK BORAL ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES, LLC
Attachment Resistance.Expressed as a Moment for Mechanically Fastened Applications ..
. _ Tile Fastener `-',Mf(ft lbf)
Roof,Tile- Direct Deck .Direct Deck
T e Count , {` Size •Shank :. Clip"p (min 15/32" (min. 19/32 Battens;
plywood) plywood),',.
Nail 2 10d Ring N/A 28.6 41.2 19.4
Nail 1 10d Smooth N/A 5.1 6.8 2.8
or Screw
Nail 2 10d Smooth N/A 6.9 9.2 7.3
or Screw
Screw 1 #8 N/A N/A 20.7 20.7 18.1
Barcelona 900, Screw 2 #8 N/A N/A 43.2 43.2 29.8
Galena3 or
Spanish"S" Smooth
Nuevo Nail 1 10d or Screw Field 23.1 23.1 19.0
Nail 1 10d Smooth Eave 29.3 29.3 24.0
or Screw
Nail 2 10d Smooth Field 27.6 27.6 38.6
or Screw
Nail 2 10d Smooth Eave 38.1 38.1 41.8
or Screw
Nail' 2 10d Ring N/A 33.1 48.1 45.2
Notes: 1)Not for Saxony 900,Villa 900 or Barcelona 900. Installation with a 4"tile headlap and fasteners are located a min.2-1/2"
from head of tile.
2)When using only one fastener,use the hole that is approximately 4-3/4"away from interlocking edge.
3)Direct Deck applications only.
Attachment Resistance'Expressed cls"a.Nloment-for Adhe'sive"o'r Mortar Set'
Rbof Tiler Adhesive Pro tluct Approval' Paddy ,;:Average Paddy Mr(ft Ibf),
Count Weight.(grams).
Dow Chemical TILE BONDTm NOA 16-0222.01 2 13.9 31.3
Bermuda,
Planation and 2 8 31.3
Saxony 900 ICP Adhesives Polyset AH-160 NCA 17-0322.03 1 24 40.4
1 45 118.9
DAP Foam Inc.Touch N'Seal® 2 8 59.0
NOA 17-0829.12 1 24 45
Saxony 900 Storm BondTm 2 Two-Component
1 45 93
Premix Marbletite, Inc.TILE-TITE NOA 17-1016.07 N/A N/A 43.9
Dow Chemical TILE BONDTm NOA 16-0222.01 2 11.4 26.1
2 8 26.1
0
Villa 900
Estate 9or ICP Adhesives Polyset AH-160 NOA 17-0322.03 1 24 45.5
1 54 86.61
Premix Marbletite, Inc.TILE-TITE NOA 17-1016.07 N/A N/A 20.6
Villa 900 DAP Foam Inc.Touch N'Seal® 2 8 55
NOA 17-0829.12 1 30 40
Storm BondTm 2 Two-Component
1 60 70
BOR18003.1 FL28328-R1 Page 10 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
G R E E BORAL ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES, LLC
Attachment Resistance Expressed as a Moment for Adhesive or'Mortar:Set
Roof,Tile Adhesive FroducfiApproval'= Paddy ;Average Paddy
. Mf'(ft Ibf).%
Count ;Weight(grams)
Dow Chemical TILE BONDTm NOA 16-0222.01 2 10.7 29.3
Barcelona 900, 2 8 29.3
Galena Spanish ICP Adhesives Polyset AH-160 NOA 17-0322.03 1 24 38.7
"S"or Spanish
°S"Nuevo 1 63 66.5
Premix Marbletite, Inc.TILE-TITE NOA 17-1016.07 N/A N/A 24.5
2 8 66.0
DAP Foam Inc.Touch N'Seal®
Barcelona 900 NOA 17-0829.12 1 30 63
Storm BondTm 2 Two-Component
1 60 82
Notes: 1)See manufacturer's product approval for installation requirements.
LABELING
1) All tiles shall bear the identifiable marking of the manufacturer's name or logo as follows:
Manufactured in Lake Wales, FL
Manufactured in Okeechobee, FL
OR
ENTE RA
BOR18003.1 FL28328-R1 Page 11 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
I
specifically addressed herein.
CREEK BORAL ROOFING LLC
Concrete Roof Tiles
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Installation of the evaluated products shall comply with FBC Section 1507.3, FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Fifth Edition Revised and the manufacturer's published
application instructions. Installations in the HVHZ shall comply with RAS 118, RAS119 and RAS 120.
3) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
4) All product listed in this shall tested quarterly in accordance with TAS 112 Appendix A.
5) Installation of the evaluated products shall be limited to projects in areas subjected to weathering indices of
50 or greater as illustrated in ASTM C 1492-03,figure 1 (see below).
I:
I: so
50 50
WEATHERING REGIONS
••�• NEGLIGIBLE WEATHERING
s MODERATE WEATHERING
SEVERE WEATHERING
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R Priest P.E. have demonstrated compliance with the Florida Building
Code, 6th Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
11
� �P(�Y G �R��p ,
9/,
` ,,i
E N SF• 2019.02.1
No 74021 lo9 10.10.22
-05'00'
13'. STATE OF : 44/
Off. <v
' < Zachary R. Priest, P.E.
Florida tion No.Registration No.71021
Organ
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
BOR18003.1 FL28328-R1 Page 12 of 12
This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.