Loading...
HomeMy WebLinkAboutEngineering Architectonic Inc— St.Lucie County Building Department Planning&Development Services Building&Code Regulation Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Code Case#99902 January 2,2020 RE: Country Cove LLC Pool House Door 4026 N US Highway 1, Ft.Pierce,FL 34946 To Whom It May Concern: Our office has performed design pressure calculations for the above referenced project and herby certify that the proposed Door are incompliance with the 2017 Florida Building Code, 160 mph wind zone, exposure "C", risk category II. Exposure "C" Multiplier for 15' mean roof height is 1.21 Wind Zone 4 29.82 x 1.21=38.08 Wind Zone 5 36.21 x 1.21=43.81 Required Design Pressures: +/-43.81 Product:Fleming Baron,Swinging exterior hollow metal doors and frame product, FL#14237.1 { Product Pressures: +/-60 Fasteners: 3/8"0 x 6"expansion bolts @ 6",24"and 6"o.c. per product approval espectfully�gbtftitte�r' i el Seal,AIA .,�(� Fyle copy AR "`L Ar I 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce,Florida 34950 Fax: 772 460 4244 FL Reg#AA26003348 1 of 1