HomeMy WebLinkAboutEngineering Architectonic Inc—
St.Lucie County Building Department
Planning&Development Services
Building&Code Regulation Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Code Case#99902
January 2,2020
RE: Country Cove LLC
Pool House Door
4026 N US Highway 1, Ft.Pierce,FL 34946
To Whom It May Concern:
Our office has performed design pressure calculations for the above referenced project and herby certify
that the proposed Door are incompliance with the 2017 Florida Building Code, 160 mph wind zone,
exposure "C", risk category II.
Exposure "C" Multiplier for 15' mean roof height is 1.21
Wind Zone 4 29.82 x 1.21=38.08
Wind Zone 5 36.21 x 1.21=43.81
Required Design Pressures: +/-43.81
Product:Fleming Baron,Swinging exterior hollow metal doors and frame product, FL#14237.1
{
Product Pressures: +/-60
Fasteners: 3/8"0 x 6"expansion bolts @ 6",24"and 6"o.c. per product approval
espectfully�gbtftitte�r'
i el Seal,AIA .,�(� Fyle
copy
AR "`L
Ar I
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com
Fort Pierce,Florida 34950 Fax: 772 460 4244 FL Reg#AA26003348 1 of 1