HomeMy WebLinkAboutProduct Approval (2) 2/13/2018 Florida Building Code Online
BCIS Home Log In I User Registration I Hot Topics I Submit Surcharge Stats&Facts I Publications FBC Staff �t BCIS Site Map Links I Search
Florida
r = lr..
...�Product Approval
p
USER,Public User
d. Product Approval Menu>Product or Application Search>Application List>Application Detail
+ + FL# FL20378-Rl
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived .i
Product Manufacturer Extreme Metal Fabricators,LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City,FL 34990
(772)872-8034
Flvalidation@yahoo.com
Authorized Signature Richard McKuhen File Colne
Flvalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City,FL 34990 R EIVI REVIE � FOR
(772)872-8034 H'� �6
richard@emfab.net
CODS CIE
Quality Assurance RepresentativeS`. LU"IE
��:"E�q""�`'
Address/Phone/Email BOCC
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the LOCKE BOWDEN
Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R.Priest,P.E.
Validation Checklist-Hardcopy Received
Certificate of Independence FL20378_Rl_COI FL 20378.1 NAILSTRIP 1.0 .032 ALUM sss.odf
Referenced Standard and Year(of Standard) Standard Year
TAS 125 2003
UL 1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
httpsl/www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquap/o2flMZ8n5CNV4ZYkew5Zoa%2fE%2fovztglbhDVU2dJO4TAA*/o3d°/`3d 1/4
2/13/2018 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 08/18/2017
Date Validated 12/18/2017
Date Pending FBC Approval 10/17/2017
Date Approved 12/19/2017
Summary of Products
FL# Model,Number or Name Description
20378.1 01-"1"Nailstrip" 0.032"Aluminum Standing Seam roof panel, 12"wide,
mechanically attached to 15/32"plywood or Wood Deck with
fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20378_RI IT FL 20378.1 NAILSTRIP 1.0 .032
Approved for use outside HVHZ:Yes ALUM_sss.pdf
Impact Resistant:No Verified By: Locke Bowden,P.E.49704
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other: Refer to evaluation report for Limitations and Evaluation Reports
Conditions of Use. Refer to manufacturer's installation FL20378_R1 AE FL 20378.1 NAILSTRIP 1.0 .032
instructions. ALUM_sss.pdf
Created by Independent Third Party:Yes
20378.2 02-"1"Nailstrip" 26-gauge Steel Standing Seam roof panel, 16"wide,
mechanically attached to 15/32"plywood or Wood Deck with
fasteners and adhesive.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378 RI II FL 20378.2 Extreme Metal Fabricators 26GA
Approved for use outside HVHZ:Yes NAIL STRIP 1.0.pdf
Impact Resistant: No Verified By: Locke Bowden,P.E.49704
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other:Refer to evaluation report for Limitations and Evaluation Reports
Conditions of Use. Refer to manufacturer's installation FL20378_R1 AE FL 20378.2 Extreme Metal Fabricators
instructions. 26GA NAIL STRIP 1.0.pddf,
Created by Independent Third Party:Yes
20378.3 03-"1.75 Snap Lock" 0.032"Aluminum Standing Seam roof panel, 18"wide,
mechanically attached to 15/32"plywood or Wood Deck with
panel clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20378_R1 II FL 20378.3 SNAP LOCK ALUM 1.75-ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for Limitations and FL20378_RI_AE FL 20378.3 SNAP LOCK ALUM 1.75-ssr.pdf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
20378.4 04-"1.75"Snap Lock" 24-gauge Steel Standing Seam roof panel, 18"wide,
mechanically attached to 15/32"plywood or Wood Deck with
panel clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_111 II FL 20378.4 1.75 SNAP LOCK 24GA-ssr.odf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No I Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for Limitations and FL20378_RI AE FL 20378.4 1.75 SNAP LOCK 24GA-ssr.odf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
20378.5 05-"Rib Panel" 29-gauge Steel exposed fastener roof panel,36"wide,
mechanically attached to 15/32"plywood or Wood Deck with
fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_El_II FL 20378.5 RIB 29GA ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for Limitations and FL20378_R1_AE FL 20378.5 RIB 29G6_5sr df
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqua°/a2fMZ8n5CNV4ZYkew5Zoa°/"2fE°/"2fovztglbhDVU2dJO4TAA%3d%3d 2/4
r _ f
i
2/13/2018 Florida Building Code Online
20378.6 06-"5V Crimp" 26-gauge Steel exposed fastener roof panel,24"wide,
mechanically attached to 15/32"Plywood or Wood Deck
w/fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_R1_II FL 20378.6_5V Crimp 52S.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other: Refer to evaluation report for Method 1 and Method 2 FL20378_91AE FL 20378.6 5V Crimp sss.Ddf
fastening. Limitations and Conditions of Use.Refer to Created by Independent Third Party:Yes
manufacturer's installation instructions.
20378.7 07-"1.5 Standing Seam" 24-gauge Steel Standing Seam roof panel, 16"wide,
mechanically attached to 15/32"plywood or Wood Deck with
panel clips,fasteners and adhesive
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL20378_R1_II_FL 20378.7 JM STANDING SEAM ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for Limitations and FL20378_91AE FL 20378.7 JM STANDING SEAM ssr.pdf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
20378.808-"Nordman Tile" 24-gauge Steel metal roof tile panel mechanically attached to
15/32"plywood or Wood Deck with fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_RI II FL 20378.8 NORDMAN TILE 24GA ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for Limitations and FL20378_R1_AE FL 20378.8 NORDMAN TILE 24GA ssr.pdf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
20378.9 09-"Nordman Tile" 24-gauge Steel metal roof tile panel mechanically attached to
Steel Deck with fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_R1_II FL 20378.9 Nordman Tile Details-ssr pdf
Approved for use outside HVHZ:Yes Verified By:James L. Buckner,P.E. @ CBUCK Engineering P.E.
Impact Resistant: No #31242
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other:Refer to evaluation report for Limitations and Evaluation Reports
Conditions of Use. Refer to manufacturer's installation FL20378_R1_AE FL 20378.9 Nordman Tile Details-ssr pdf
instructions. Created by Independent Third Party:Yes
20378.10 10-"Nordman Tile" 0.032"Aluminum metal roof tile panel mechanically attached
to 15/32"plywood or Wood Deck with fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_RI II FL 20378.10 NORD TILT.032 ALUM-ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for Limitations and FL20378_Rl AE FL 20378.10 NORD TILT.032 ALUM-ssr.odf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.copyrWht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,
please click here.
Product Approval Accepts:
Lr M ®99 0
Credit Card
Safe
https.,//www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqua°/a2flMZ8n5CNV4ZYkew5Zoa°/"2fE%2fovztglbhDVU2dJO4TAA%3d%3d 3/4
Product Report Manufacturer: Extrem,e Metal Fabricators,
2160 SW Poma Drive
Palm City, FL 34990
(."772) 872-8034
Florida / NON
Compliant with Florida Building Code 2017(6th ed.)
Compliant with Florida Product Approval Rule #61G20-3
Compliant : Keystone Certifications
Product: 5 V Crimp 26GA Metal Roofing Panel Corrosion Resistant FBC Sec. 1507.4.3
Yield strength:40ksi Steel Attached to min. 15/32" plywood or Wood Deck w/ min.
Attached 24" OA2 specific gravity with screws.24" Coverage
Coverage Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec. 1506, 1507
Fastener for Method 1 Attachment# 9-15 x 1"Hex Head w/EPDM Bonded Steel Washer
to penetrate 3/16"thru wood decking
Fastener for Method 2 Attachment#9-15 x 1"Hex Head w/EPDM Bonded Steel Washer
to penetrate 3/16"thru 15/32"min. plywood deck or 5/8" into wood plank
Underlayment: To be compliant with FBC Sec.1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
Install Details: Table A Allowable Loads METHOD 1 METHOD 2 :�FASTENER PLACEMENT
DESIGN PRESSURE* -85 PSF -114.25 PSF METHOD 11N RIB PEAKS
ROW SPACING 12"O.C. 12"O.C. METHOD 21N PANEL FLATS
FASTENER SPACING s 12" O.C. 12"O.C. "SEE INSTALL DRAWINGS
FASTENER SIZE: 1 #9 #9
*ALLOWABLE DESIGN PRESSURE MARGIN OF 2 TO 1
Reference Data: HURRICANE TEST LAB#TST ID: 1527
TAS 125-03 Test#0223-0307-01;METHOD 1 (UL 1897-04')
TAS-125-03 Test#0223-0517-06,METHOD 2
EQUIVALENCY UL 1897-04 IS EQUIVALENT TO UL 1897-12 TEST STANDARD * DESIGN PRESSURE SAFETY MARIGIN 2:1
Certificate of Independence:
Locke Bowden,P.E.does not have,not will acquire a financial interest in any company manufacturing or distributin t�rr products
S��Lc,lltr
under this evaluation. �<<a{
Locke Bowden,P.E.is not owned,operated,or controlled by any company,manufacturer,or distributlGro cts def-t�iy�
report. •` Cj' ' GE��`S.�' WIN,
2'
;e
x I
" i'P.iE OF ' 4/:.,
Compliance Statement: These products herein evaluated have demonstrated compliance with the Florida Building Code 2017
61h ed.,with referenced documents submitted.
Limitations:
1. Underlayment to be compliance with current Florida Building Code 2017 61h ed-,Section 1507.1.1
2. Products are compliant for State of Florida product approval per Rule 61G20-3
3. Compliance Method: 1-D
4. Fire classification is not part of this acceptance.Shear diaphragm values are outside this report.
5. All support framing compliant w/Florida Building Code 2017,Chapters 22 for Steel,23 for Wood and 16 for
Structural Loading.Design of support and attachment to the framing is outside the scope of this evaluation.
6. Rule 61G20-3 allows for engineering analysis by registered/licensed others for"project specific approval" by local
authorities,authorized by the code,and is the responsibility of others.
7. This report does not imply warranty,installation,recommended product use outside of this report.
Fasteners-
419-15 Hex-Head Screvs With 5V-Crimp" Roof Panel
EPDhI Bonded Steel Washers
1 �
,t- r<rr.,s:?:ter „�e?+ •.e' ..r_.._L__r,.�':_�.'.:'"'•x ..i.r ' I v,^�,t��!
Deck:
-15/32 or greater Ply%mod,or
-Wood plank,
Fasteners-
-15 Hex-Head Screws With 5V-Crimp^ Roof Panel
EPDM Bonded Steel Washers
Ja
'll -tri '•tif
ct r j I� n n rllt
I 1' 10
t�
ylil a
t T 'Tp
�—Deck:
-1513T or greater Plywood,or
Wood plank