Wind Load Calculation
RECEIVED VUV JAN 302 020 HURRICANE SHUTTERS, INC. PANELS • ACCORDIONS • BAHAMAS ST. Lucie County, Permitting COLONIALS • ROLL UPS Property Information Building Information Owner: Jamie Marie Swanson Reichenbach(LF EST) Wind Zone: 170 MPH. Address: 2465 NW Lakeridge Drive Exposure Category: B Palm City,FL 34990 Minimum Building Dimension: 5 ft. Mean Roof Height: 15 ft. Risk Category: II Desi n Pressure Calculations Opening Location IF Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in)-Ir Elevation(ft) Pressure(ps fl Pressure(ps fl 1 "Int 40.25 54.75 7 30.3 -32.9 2 Int 50.5 54.75 7 29.8 -32.5 3 Int 40.25 54.75 7 30.3 -32.9 4 Int 60 32 7 30.6 -33.2 5 Int 50 60 7 29.7 -32.3 6 Int 50 60 7 29.7 -32.3 7 Int 89 60 7 28.5 -31.2 8 Int 248 133 7 24.8 -27.5 9 Int 66 72 7 28.7 -31.4 110 Int 62 36 7 30.3 -32.9 �11 Int 66 36 7 30.2 -32.8 12 Int 66 72 7 28.7 -31.4 3 Int 66 72 7 28.7 -31.4 14 Int 57 58 7 29.5 -32.1 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1