Loading...
HomeMy WebLinkAboutProduct Approval (6) L. Roberto Lomas7R-ECEIVED r-i' 1432 Woodford Rd. Manufacturer: Masonite Lewisville,NC 27023 Report#: 514008 434-688-0609 N 30 '2020 Date: 05/01/2017 rllomasCaD-lrlomaspe.com Test Report: N/A ST. Lucie county, Perm l Ing Product. Double Do ood frame) Scope: This analysis provides calculations,quantities,and spacing requirements for installing product to substrate,and it applies only to th� roduct described herein.These calculations comply with requirements of the Florida Building Code. 'arz,capacity in shear condition: i members w/6 w/out gap: With threads present in shear plane Fastener type:#10 wood screw (NDS 2012,TR12) Nominal diameter: D: 0.190 in Gap: g: 0.0000 in Root diameter: Dr: 0.152 in Moment arm: 0.0000 in Minimum required penetration: p: 1.140 in Screw bending yield strength: Fyb= 80,000 psi Side member: Douglas Fir-Larch(6=0.50) Main member: Spruce-Pine-Fir(6=0.42) Side member thickness: t,- 1.000 in Main member thickness: tm= 1.500 in Side member dowel bearing strength: F.= 4,650 psi Main member dowel bearing strength: F•„= 3,350 psi Side member dowel bearing length: Is= 1.000 in Main member dowel bearing length: Im= 1.140 in ModeQ I,,, Mode I, Mode II Mode III., Mode III, Mode IV qm= 636.5 lbs/in qs= 884 lbs/in A: 0.0007 A: 0.00096 A: 0.00107 A: 0.0014 P= 725.61 lbs P= 884 lbs B: 1.07 B: 0.57 B: 0.5 B: 0.000 Ko= 2.400 Ko= 2.400 C: -427.67 C: -253.62 C: -267.7 C: -93.6 Z,,,= 302 lbs Z,= 368 lbs P= 331 lbs Ms= 46.8 in-lbs Mm= 46.8 in-lbs KD= 2.400 P= 297 lbs P= 319 lbs P= 263 lbs Min.Design value: Z= 110 lbs Z= 138 lbs Ko= 2,400 KD= 2.400 Ko= 2.400 Duration Factor: CD= 1.6 Z= 124 lbs Z= 133 lbs Z= 110 lbs Allowable Design Value(ZCD): Z'= 175 lbs/anchor Solid members w/d w/out gap: a. With threads present in shear plane Fastener type:#1O wood screw (NDS 2012,TR12) Nominal diameter: D: 0.190 in Gap: 9: 0.0000 in Root diameter: Dr: 0.152 in Moment arm: 0.0000 in Minimum required penetration: p: 1.140 in Screw bending yield strength: Fyb= 80,000 psi Side member: Douglas Fir-Larch(6=0.50) Main member: Steel strap/clip Side member thickness: t,= 1.000 in Main member thickness: t.,= 0.048 in Side member dowel bearing strength: F.= 4,650 psi Main member dowel bearing strength: F,,,,= 61,850 psi Side member dowel bearing length: I,= 1.000 in Main member dowel bearing length: Im= 1.140 in Mode I., Mode I, Mode 11 Mode III, Made III, Mode IV qm= 11752 lbs/in qs= 884 lbs/in A: 0.0003 A: 0.00059 A: 0.00033 A: 0.0006 P= 13397 lbs P= 884 lbs B: 1.07 B: 0.57 B: 0.5 B: 0.000 KD= 2.400 KD= 2.400 C: -4038.9 C: -3864.9 C: -267.7 C: -93.6 7„_ , 5582 lbs Z,= 368 lbs P= 2287 lbs Ms= 46.8 in-lbs Mm= 46.8 in-lbs KD= 2.400 P= 2126 lbs P= 420 lbs P= 392 lbs Min.Design value: Z= 163 lbs Z= 953 lbs Ko= 2.400 Ko= 2.400 KD= 2.400 Duration Factor: Co= 1.6 Z= 886 lbs Z= 175 lbs Z= 163 lbs Allowable Design Value(ZCD): Z'= 262 lbs/anchor Fastener type: 1/4"ITW Tapcon N.O.A.16-1222.06 Substrate: Hollow block Minimum embedment: 1.25 in Edge distance: 4.00 in Tabulated shear design value: Z= 202 lbs Edge distance: 2.00 in Tabulated shear design value: Z= 161 lbs Actual edge distance: 2.50 in Reduction factor: 0.85 Spacing: 4.00 in Tabulated shear design value: Z= 202 lbs \�� 0 Spacing: 2.00 in Tabulated shear design value: Z= 164 lbs `� •iA�.1, x Actual spacing: 3.00 in Reduction factor: 0.91 *N V •`�j E IV S••w'/�� Allowable Design Value(ZfAN): Z"= 155 lbs/anchor ` • Minimum anchor capacity: 155 lbs/anchor 51 •� Note:Anchors with the least capacity Is used for calculations to qualify anchor;with higher capacity. TAT O P lh* , ZA.,, F 0 R1ORMDP• i . 11(I11� Luis R. Lomas P.E. FL No.: 62514 1 of 3 5/2/2017 L. Roberto Lomas P.E. i432woodlo,dRd. Manufacturer: Masonite Lewisville,NC 27023 Report#: 514008 434-688-0609 Date: 05/01/2017 rllOmas(a)Irlomaspe.com Anchor calculations,minimum reouired anchors 36.38 . 36.38 Design pressure: 60.0 psf --- --~ Area Load Ind. Max. Anchor Ir Al 71 Zone z O.C. Cap. Qty Load Result 79.25 (ff) (lbs) (in) (in) (lbs) (lbs) Al Al J Al 2.3 138 N/AN/A 155 1 138 OK AZ 7.7 463 6.00 21.00 155 5 93 OK 72.75 A3 7.7 463 N/A N/A 1 155 3 154 OK 37.50 36.38 36.38 37.50 Design pressure: 60.0 psf Max. Anchor AreaLoad Ind. Al A4 A4 Al Y Y (ft Zone z O.C. Cap. Load Result Y A2IY� ) (lbs) (in) (in) Obs) Q'�' (lbs) Al 2.4 146 NIA N/A 155 1 146 1 OK A Aa Al P3 A5 P3 79 25 AZ 7.9 473 6.00 2100 155 5 95 OK A, 7.8 468 N/A N/A 155 4 117 OK 147.75 A4 2.3 138 N/A N/A 155 1 138 OK A5 7.7 463 N/A N/A 155 3 154 OK Anchor Locations: Double door 36.38 36.38 6.00 TYP. 6.00 TYP. 18.19 TYP. 3.00 TYP. 6.00 13.45 MAX.O.C. 79.25 1�ti'\,�C E NS9••`r/- 6.00 4- TAT' 51 4F • �� w �0.c�•. OR OV" ••'�'�� s/0NAL,0����� Luis R. Lomas P.E. FL No.: 62514 2 of 3 5/2/2017 L. Roberto Lomas P.E. 1432 woodrord Rd. Manufacturer: Masonite Lewisville,NC 27023 Report#: 514008 434-688-0609 Date: 05/01/2017 rllomas(a)lrlomaspe.Com Double door with sidelites ---37.50 --- -- -36.38----�-- –36.38 37.50 --18.757YP. 6.00TP.-i-- 16.00TW.- r--18.19TYP.– 3.00 TYP. -�-----6.00-- i 13.45 MAX.O.C. i 79.25 6.00 Installation instructions: 1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE#10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4"MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2"MINIMUM EDGE DISTANCE.LOCATE ANCHORS AS SHOWN BELOW. 2. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16"TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4"MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE.LOCATE ANCHORS AS SHOWN BELOW. 3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE#10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL WITH 1/2"MINIMUM EDGE DISTANCE.LOCATE ANCHORS AS SHOWN BELOW. 4. ALL FASTENERS TO BE CORROSION RESISTANT. 5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN ``, SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: ��� a A.WOOD:MINIMUM SPECIFIC GRAVITY OF G=0.42 ` //j/ B.CONCRETE:MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. \� •�! E At C.MASONRY:HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PS1 MINIMUM. �\0 D.METAL STRUCTURE:STEEL 18GA(.048")FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KS1 ` • .052"THICK MINIMUM *• Os 51 •�► = 6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE '— DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN. TAT OF ; N. FS OR tOP• � ///S ZONAL E0G��\ /11111 Luis R. Lomas P.E. FL No.: 62514 3 of 3 5/2/2017