HomeMy WebLinkAboutEngineering . CORSON & ASSOCIATES Ing.
RECEIVE. CHITECTURE * STRUCTURAL DESIGN
412 Colorado Ave., Stuart,Fl. 34994
JAN ?02.0 (772)223-8227 * Lic. #AR91665
ST. "W. �4�(iFiS�t"Br�tt�t1F!9
Date: January 21,2020
To: St. Lucie County -Building&Code Regulation Division
Re: Miriam McCue Residence
11000 S. Ocean Drive,Unit 5-B
Jensen Beach,Fl. , 34957
It is acceptable to replace existing sliding glass door openings for the address
listed above as follows:
1) S.G.D -The International Bldg. Products L.L.C. Series "Titan 90" Alum.L.M.I.
sliding glass door has a Florida number NOA- #18-0412.01. It has a+90/-90
design pressure and has a large missile "D" approval and HVHZ .
The actual building design pressures of address listed above in Zone 4 -is+50.51-54.8.
The building has a type II classification and exposure category "D" for the 6th Edition of
the FBC (2017). Worst case scenario has been calculated.
Thank you for your time and consideration. If you have any questions please call.
Respectfully,
f c Mark A� rson,,-.,-NCARB
Presdei%t FrA._ Y' 1le Copy
A
REVIEWED FOR
CODE COMPLIANCE
Cga
ST'® LUC@E C®� �,`�'�
BOCC '�a��1.oZ0