HomeMy WebLinkAbout20200204092045199ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: 02/4/2020 Permit Number:
OS,
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential X
PERMIT APPLICATION FOR: Mechanical
Address: 5502 seagrape dr
Legal Description:
Property Tax ID #: 3402-609-0067-000-9 Lot No.
Site Plan Name: Block No,
Project Name: Jennifer taylor
Setbacks Front Back: Right Side: Left Side:
LIKE FOR LIKE A/C CHANGEOUT and duct work 2 ton
16 seer
5 kw
Add Yiona Iwork to be oerfornried under thispermit—c allLr= apply:
ZHVAC Gas Tank ❑Gas Piping Q Windows/Doors
_Shutters
Electric Plumbing ❑Sprinklers Generator 11 Roof F7 Roof pitch
Total Sq. Ft of Construction: 5 Ft. of First Floor:
Cost of Construction: $ 9858.00 Utilities:05ewer Septic Building Height:
0� r
10108
�0 TRq�T1 9
gpark
.«._
Name Jennifer taylor
Name: CHRIS LANGEL
Address: 5502 seagrape dr
Company: SEACOASTA/C
city: fort pierce State:fl
Address: 3108 INDUSTRIAL 31st STREET
Zip Code: 34982 Fax:
City: FT PIERCE State; FL
Phone No. 754-214-4703
Zip Code: 34946 Fax: 772448-4416
_
E-Mail:
Phone No. 772-466-2400
Fill in fee simple Title Holder on next page ( if different
E-Mall: INFO@SEACOASTAIR.COM
from the Owner listed above)
State or County License: CM0035421
If value of construction Is $2500 or more, a RECORDED Notice of Commencement is required.
Name:
Address:
City: State:
Zip: Phone:
FEE SIMPLE TITLE HOLDER:
Name:
Address:
City:
Zip: Phone: _
_Not Applicable
MORTGAGE COMPANY: Not Applicable
Name:
Address:
City: State:
Zip: Phone:
BONDING COMPANY:
Name:
Address:
_Not Applicable
I certify that no work or Installation has commenced prior to the issuance of a permit.
St. Lucie Count yy makes no representation that Is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply,
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St, Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review; room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite
before the first Inspection.,� yoSa}}ntend to obtain financing, consult with lender or an attorney fore
commencing work or recoA rig Notice of Commencement. Z/ ?
as
STATE OF FLORIDA
COUNTY 0 F sr Lucie
STATE OF FLORIDA
CO U NTY O F sr wcie
Holder
The forgoing instrument was acknowledgee��jj }�before me The forgoing instrument was acknowledged before me
this 4ULday of Jebruzify.. Y this 4th day of february zo�by
CNRIS (ANGEL 1 CHRIS LANGEL
{Name of person acknowledging) (Name of person acknowledging )
ignature of No ary Public -State of Florida )- Q (Sikhature of Notar}Public-State of Florida) �
Personally Known x OR Produced Identification Personally Known x OR Produced Identification
Type of IdontiRcatlon Produced Type of Identification Produced
Commission No. GGe405 ,o••1jti';;;••-,, JUSTI(�aItAOPKINSCONNELLY Commission No. ccsaoIt
it
4 JUSTINA , SINSCONNELLY
N MYCOMMISSIONSGG8G05S2 �' `S
,K!, i._.... .± k, MYCOMMISSIQN8GGS40ii82
Revised
07/15/20
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEA TURTLE
MANGROVE
COUNTER
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
DATE
COMPLETE
INITIALS
AHRI Certified Reference Number: 9198582 Dale : 02-03-2020 Model Stalus :Active
AHRI Type : RCU-A-CB
Series : 16 SEER AC
Outdoor Unit Brand Name: CARRIER
Outdoor Unit Model Number (Condenser or Single Package) : CA16NA024*0**A*
Indoor Unit Model Number (Evaporator and/or Air Handler) : FB4CNP025L
Region: Southeast and North (AL, AR, DC, DE, FL, GA, HI, KY, LA, MD, MS, NC, OK, SC, TN, TX, VA, AK, CO, CT, ID, IL,
Al IN, KS, MA, ME, MI, MN, MO, MT, ND, NE, NH, NJ, NY, OH, OR, PA, RI, SD, UT, VT, WA, Wv, WI, WY, U.S.
Territories)
Region Nole : Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions
until June 30, 2016. Beginning July 1, 2016 central air conditioners can only be installed in region(s) for
which they meet the regional efficiency requirement.
t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being
marketed but are not yet being produced"Production Slopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still
selling or offering for sale.
Ratings that are accompanied by WAS indicate an involuntary re -rate. The new published rating is shown along with the previous (i.e. WAS) ration.
DISCLAIMER
AHRI does not endorse the products) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for,
the products) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the
nauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and conflguratiars listed in the
directory at www,ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and
confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; AM
entered into a computer database; or otherwise utilized, in any form or manner or by any means, cept far the user's individual,
personal and confidential reference. AIR-CONDITIONING, HEATING,
CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE
The Information for the model cited on this certificate can be verified at www.ah rid irectory.org, click on "Verify Certificate" link we make life better'°
and enter the AHRI Certified Reference Number and the date on which the certificate was issued,
which is listed above and the Certificate No., which is listed at bottom right
02020Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: ,Szzs22942252G7,RR
d wrightsoW Project Summary Job:
Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 PIwre:772-4fiGfi799 EmaiI:QUICKCALCS�oIAOLCOM
For: JENNIFERTAYLOR
5502 SEAGRAPE DRIVE, FT. PIERCE, FL 34982
Notes:
Weather: Fort Pierce, FL, US
Winter Design Conditions Summer Design Conditions
Outsidedb 42 OF Outsidedb 90 OF
Insidedb 70 OF Insidedb 75 OF
Design TD 28 OF Design TD 15 OF
Daily range M
Relative humidity 50
Moisture difference 61 grAb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 15904 Btuh Structure 15204 Btuh
Ducts 2039 Btuh Ducts 1358 Btuh
Central vent (0 elm) 0 Btuh Central vent (0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 17943 Btuh Use manufacturers data n
Rate/swingq multiplier 0.95
Infiltration Equipmentsensible load 15734 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2145 Btuh
Ducts 1068 Btuh
Central vent (0 cfm) 0 Btuh
Heatingg Coolingg (none)
Area (ft') 1050 1050 Equipment latent load 3214 Btuh
Volume (ft') 8400 8400
Airchangesihour 0,45 0.23 Equipment Total Load (Sen+Lat) 18947 Btuh
Equiv. AVF (cfm) 63 32 Req. total capacity at 0.70 SHR 1.9 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make Carrier
Trade Trade CARRIER
Model Cond CA16NA02400GOA0
AHRI ref Coil FB4CNP025L
AHRI ref 9198582
Efficency 100 EFF Efficiency 13.5 EER,16 SEER
Heating Input 7.8 kW Sensible cooling 16800 Btuh
Heating output 26550 Btuh Latentcooling 7200 Btuh
Temperature rise 30 OF Total cooling 24000 Btuh
Actual air flow 800 cfm Actual air flow 800 din
Airflowfactor 0,045 cinBtuh Airflowfactor 0.048 cfm/Btuh
Static pressure 0.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.84
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
�}+- wrigntsoitn 2ozo-Fab-o46e:n:g7
��^-^^-•^ +^^^^^^--- RigM-Sule®Urvversa1201919.0.07 RSU08101 Pagel
..?DownerilslWngNsoft HJAC\TAYLOR, JENNIFER.OQ CaIc=MJB RorY.Door faces: W
wrightsoft® Duct System Summary
Entire House
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL34846PMre:772-4666799 EmaII; OUICKCALC9@AOL.COM
�Project information
For: JENNIFERTAYLOR
5502 SEAGRAPE DRIVE, FT. PIERCE, FL 34982
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual airflow
Total effective length (TEL)
Heating
0.50
in H2O
0.28
in H2O
0.22
in H2O
0.170 / 0.050
in H2O
0,080
in/100ft
800
Cfm
Job:
Date:
ey:
Cooling
0.50 in H2O
0,28 in H2O
0.22 in H2O
0.170/0.050 in H2O
0.080 in/100ft
800 cfrn
Name
Design
(Btuh)
Htg
(Cfm)
Cl9
(Cfm)
Design
FIR
Diam
(in)
H x W
(in)
Duct
Matt
Actual
Ln (ft)
FtgIE
Ln (ft)
Trunk
BATH
h 838
37
17
0,080
5.0
Ox0
V1Fx
6.3
70.0
BEDROOM
h 3040
136
133
0.080
8.0
Ox0
VIFx
10.0
70.0
BEDROOM2
In 3146
140
111
0,080
TO
Ox0
VIFx
8.5
70.0
KITCHENIDINING
c 2793
116
135
0.080
8.0
Ox0
VIFx
21.3
95.0
stl
KrrCHENAINING-A
c 2793
116
135
0.080
TO
0x0
VIFx
8.6
70.0
LIVING ROOM
c 5575
254
269
0.080
9.01
Ox0
VIFx
25.3
95.0
stl
:Supply Trunk Detail Table
Name
Trunk
Type
Htg
(c8n)
Clg
(Cfm)
Design
FIR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Duct
Material
Trunk
st1
PeakAVF
370
404
0.080
515
12.0
0 x 0
VmIFlx
Return Branch Detail Table
Grille
Htg
Clg
TEL
Design
Veloc
Diam
H x W
Stud/Joist
Duct
Name
Size (in)
(Cfm)
(cftrl)
(ft)
FR
(fpm)
(in)
(in)
Opening (in)
Matl
Tmnk
rbl
Ox0
370
404
34,5
0.144
515
12.0
Ox 0
VIFx
rb3
Ox0
173
149
35.1
0.142
391
9.0
0x 0
VIFx
rb2
Ox0
257
246
34,1
0.146
735
8.0
0x 0
VIFx
BclNrtallc values have been manualfyovenidtlen
WI'IJhY50fY' 2020-Feb-0408:11:07
Right-SU(e®UYiversa1201919.007 RSU08101 Pagel
�` ...�DoanieMs\Wn9R�fl HdAC\TAYLOR,JENNIFER.np CaIc=MJB FrarA Doolfaces: W
I� wrightsoft° Right4g) Worksheet Job:
Entire House Date:
By.
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772-466-6799 Email: OUICKCALCS@AOL.COM
1
Room name
Entire House
LIVINGROOM
2
Bposadwell
130.0 ft
38.0 ft
3
Room height
8.0 ft
8.0 it heaVowl
4
Roomdimensons
23,0 x 15.0 ft
5
Roomarea
1050.0 ft 345.0
I12
Ty
Consruaon
U-value
Or
HTM
Area (W)
Load
Area (ftj
Load
number
(BtuhAt2-°r)
(BtJM2)
or perimeter (ft)
(B1uh)
or perimeter (ft)
(BWh)
Heat
Cod
Gross
N/P/5
Heat
Cool
Gross
N/V/S
Heat
Cool
6
13A-0as
0,143
n
4,00
219
240
186
745
407
120
96
384
210
1AcHom
1.270
n
3556
3477
9
0
320
313
0
0
0
0
V
1Aciom
1.270
n
3556
34.77
24
0
853
1 835
24
0
.853
835
11D0
0.390
n
10.92
10.34
21
21
229
217
0
0
: 0
0
11
W
13A-4os
0.143
e
4.00
2.19
280
218
874
477
0
0
0
0
10B-v
0,600
a
16.80
31A5
41
2
685
1283
0
0
0
0
to-dom
1.270
a
35.56
84,36
9
1
320
759
0
0
0
0
to-clom
1.270
a
35.56
86.05
12
1
427
1033
0
0
0
0
13A-0as
0143
a
4,00
2A9
240
212
849
464
0
0
0
0
1Aclom
1.270
a
35.56
34.77
4
4
142
139
0
0
0
0
1A-mom
1270
a
35.56
34,77
24
24
853
835
0
0
0
:0
�7ljA—G
13AA s
0.143
w
4.00
2.19
280
223
893
488
184
139
557
304
LA-dom
1.270
w
35.56
86.05
36
3
1280
3098
24
2
853
2065
u--D
11DO
0.390
W
1092
10.34
21
21
229
217
21
21
229
217
C
16X190m1
0.408
1.59
1.13
1050
1050
: 1665
:1189
345
345
::547
391
F
22A-td
0,989
-
2769
0.00
1050
130
3600
0
345
38
1052
0
6
c)AEDexa.rson
0
475
Envelopeloss/gain
13965
11753
4476
4407
12
a) Infiltration
1939
531
567
155
b) Roomventilation
0
0
0
0
13
Internal gains Ccoupants@ 230
4
920
2
460
Aoplian¢srother
2000
0
Subtotal(Imes6 to 13)
15904
15204
6043
5112
Lessextemal load
0
0
0
0
Lesstrander
0
0
0
0
Redistribution
0
0
9
6
14
Subtotal
15904
15204
5052
5118
15
Ductloads
13%
9%
2047
1363
130/6
9%
650
459
Total room load
17950
16567
5703
5577
Air required(dm)
840
840
267
283
Calculations approved bVACCA to meet all requirements of Manual J Sth Ed.
'I" wrlgiitsoR^ 202PFeb-03 t2:08:03
�'�`�-p Ri9Fh-SuIeNJ Uriversa1201919.0.07 RSU08701 Page 1
...\DoaanentMWrigltsoRWAC\TAYLOR,JENNIFER.rW Calc=MJ8 Frort Ewrfaces: W
wrightsoW Right-J® Worksheet Job:
Date:
Entire House
By:
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, FL34946Phow 772A66-6799 Emall:OtRCKDAL(i$@AOL.COM
1
Room name
BEDROOM
BEDROOM2
2
Expo dvell
23.0 ft
24.0 It
3
Roam height
8.0 it heaVcooi
8.0 ft heaNmol
4
Roomdimenslons
12.0 x 11.0 ft
12.0 x 12.0 ft
5
Roomarea
132.0 In
144.0 IF
Ty
Consbucaon
U-value
Or
HTM
Area (ft0
Load
Area (ft0
Load
number
(BtuhM'--°F)
(BtUW
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Stuh)
Heat
Cool
Gross
NIPS
Heat
Cool
Gross
NPIS
Heat
Cool
6
t
13A-4ors
0.143
n
4.00
219
0
0
0
0
0
0
0
0
0��-(DC`
1A-clom
1.270
n
35.56
3477
0
0
0
0
0
0
0
D
1Aclom
1.270
In
35.56
34.77
0
0
0
0
0
0
0
0
11D0
0.390
n
10.92
10.34
0
0
0
0
0
0
0
0
11
W
13A-4ocs
0.143
a
4.00
2.19
0
0
0
0
96
84
336
184
1013-v
0.600
a
16.80
31 A5
0
0
0
0
0
0
0
0
IA -Glom
1.270
a
35.56
94.36
0
0
0
0
0
0
0
0
to -Glom
1270
a
35.56
86.05
0
0
0
0
12
1
427
1033
W
13AA=
0,143
s
4,00
2,19
88
76
304
166
96
84
336
184
IA-ctom
1.270
s
35.56
34.77
0
0
0
0
0
0
0
O
1A-ctom
1.270
s
35.56
34.77
12
12
427
417
12
12
427
417
13A-4=
0.143
w
4.00
2.19
96
84
336
184
0
0
0
0
1Aclom
1.270
w
3556
86.05
12
1
427
1033
0
0
0
0
11DO
0.390
w
1092
10.34
0
0
0
0
0
0
0
0
C '.
16X19-0ml
0.408
1.59
1.13
132
132
209
' 149
144
144
`.:228
163
F
22A-Ipl
0.989
-
2769
0.00
132
23
637
0
144
24
665
0
6
) AED e=rdon
241
-199
Enwlopelos4gain
2340
2191
2419
1781
12
a) Infiltration
343
94
358
98
b) Roomventlaton
0
0
0
0
13
Internal gains Ocwpanis@ 230
1
230
1
230
Appllznoesbiher
0
0
Subbtal(lines6tol3)
2683
2515
27T7
2109
LesseAemal load
0
0
0
0
Lesstransfer
0
0
0
0
Redistribution
12
8
12
8
14
Subtotal
2695
2522
2789
2117
15
Ductloads
13°/a
9%
347
226
13%
9%
359
190
Total room load
3042
2748
3147
2306
Air required (dm)
142
139
147
117
Calculations approved bVACCAto meet all requirements of Manual J Sth Ed.
• �' wrl9i�tsoR^ 2020-Feb-0312:08:03
�� ""-"'•'^ RIgM-Sdte®Uhversa1201919.0.07 RS1108101 Paget
...tDom nts\WnghlsoftWAC\TAYLOR,JENNIFER.nQ CaIc=MJ8 Front Doorfaces: W
wrightsoft' RighW@ Worksheet Job
Entire House Date:
By:
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772466-6799 EmalI: QUICKCALCS@AOLCOM
1
Room name
IOTCHEN/DINING
BATH
2
ENrosecimll
38.0 it
7.0 it
3
Room height
8.0 it heat/cool
8.0 it hez7000l
4
Roomdlmensions
23.0 x 15.0 ft
7.0 x 7.0 it
5
Room area
345.0 ft2
49.0 11
Ty
Construction
U-value
Or
HTM
Area (IN)
Load
Area (It')
Load
number
(Bfu11M'--°F)
(Btuh&2)
or perimeter (it)
(Btuh)
or perimeter (f)
(But)
Heat
Cool
Gross
NOS
Heat
Cool
Gross
N/P/S
Heat
Cool
6
%h13A-4ors
0.143
It
4.00
2.19
120
90
360
197
0
0
0
0
1A-clom
1.270
It
35.56
34.77
9
0
320
313
0
0
0
0
to-clom
1270
It
35.56
34.77
0
0
0
'0
0
0
0
0
11D0
0.390
It
10.92
10.34
21
21
229
217
0
0
0
0
11
W
13A-4c s
0.143
a
4.00
2.19
184
134
537
294
0
0
0
0
10B-v
0.600
a
16.80
31A5
41
2
685
1283
0
0
0
0
IA-ciom
1.270
a
35.56
84.36
9
1
320
759
0
0
0
0
IA-clom
1.270
a
35.56
86,05
0
0
0
0
0
0
0
0
13A-4=
0.143
s
:400
2.19
0
0
0
0
56
52
208
114
1Aclom
1270
s
3556
34.77
0
0
0
0
4
4
142
139
1A-clom
1.270
S
35.56
34,77
0
0
0
0
0
0
0
0
UN
13A4as
0.143
w
4.00
2.19
0
0
0
0
0
0
0
0
IA-ctom
1.270
w
35.56
86.05
0
0
0
0
0
0
0
0
LI-GG
11D0
0,390
w
10.92
10.34
0
0
0
0
0
0
0
0
C
16X19-Oml
0.408
1.59
1,13
345
345
547
391
49
:.. 49
78
55
F
22A Ipl
0,989
-
27.69
0.00
345
3B
1052
0
49
7
194
0
6
c)AED excursion
484
'29
Envelopeloss/galn
4052
2969
622
270
12
a) Infiltration
567
155
104
29
b) Roommentilation
0
0
0
0
13
Internal gains O=pants@ 230
0
0
0
0
Applianoesblher
2000
0
Subtotal(lines6 to 13)
4619
5124
726
308
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redisbibuton
7
5
16
11
14
Subtotal
4625
5129
743
318
1151
Dualoads
130/.
9%
595
460
130/.
91%
96
29
Total room load
5221
5588
838
347
Air required(dm)
244
283
39
18
Calculations approved bvACCAto meet all requirements of Manual J Sth Ed
-r�+- wrrgncsore- zozo-Feb-o3lz:oe:o3
�A """""°"""•""""^•'_°"' Po9H-SUIe®Unversa1201919.0.07 RSU08101 Pa9e3
..)Downenls\WdgMSOR M/AC\TAYLOR,JENNIFER.np CaIc=MJB Fronl Door laces: W
wriyntsoft° RighW@ Worksheet Job'
Entire House Date:
aY:
QUICK CALCSr INC.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phow: 772A66-6799 EmaiI:QUICKCALCS@AO .
1
Room name
HALL
2
Expo dwall
0 ft
3
Room height
8.0 IF heagmol
4
Roomdimendons
5.0 x 7.0 ft
5
Room area
35.0 ft'
Ty
Construction
1-1-value
Or
HTM
Area (113
Lead
Area
Load
number
(BtuhAt' °F)
(Btuh&)
or perimeter (ft)
(Btuh)
or perimeter
Heat
Cool
Gross
NIPS
Heat
Cool
Gross
NrP/S
Heat
Cool
6%h
13A-4=
0.143
in
4.00
2,19
0
0
0
0
1Aolom
1.270
n
35.56
34,77
0
0
0
0
1Aclom
1.270
n
35.56
34.77
0
0
0
0
11DO
0,390
n
10.92
10.34
0
0
0
0
11
w
13A-4ocs
0.143
a
4.00
2.19
0
0
0
0
I--G
10B-v
0.600
a
16.80
31A5
0
0
0
0
1Aaiom
1.270
a
35.56
84.36
0
0
0
0
II---CGi
1Aciom
1.270
a
35.56
86.05
0
0
0
0
13A4ocs
0.143
s
4.00
2,19
0
0
0
0
1Aciom
1.270
s
35.56
34.77
0
0
0
0
1Actom
1270
s
35.56
34.77
0
0
0
0
lRJ
13A-0as
0.143
w
4.00
2.19
0
0
0
0
1Aciom
1.270
w
35.56
86.05
0
0
0
0
11DO
0.390
w
1092
10.34
0
0
0
0
C
16X19-oml
0A08
1.59
1.13
35
35
;.55
40
F
22A-tPI
0.989
-
27.69
0.00
35
0
0
0
6
) ADD exairdon
-3
Envelope losstgain
55
36
12
a) Infiltration
0
0
b) Roomvenuation
0
0
13
Internal gains O=pants@ 230
0
0
Aopliano:slother
0
Subtotal(ines6 to 13)
55
36
Leaselemaiload
0
0
Leas transfer
0
0
Redistribution
-55
-36
14
Subtotal
0
0
15
Ductloads
13%
9%
0
0
Total room load
0
0
Air required(cfm)
0
0
Calculations approved bvACCAto meet all requirements of Manual J 8th Ed
_ �.r .�..�lynesore- zozo-Feb-9312:oe:o3
�� ^"""' "• -^ "'^ Ri9h<-Sule®Unversa1201919.0.07 RSU08101 Page4
..}DaanierAs\WngHsofl FNAC\TAYLOR,JENNIFER.np CaIc=MJB Frort Uoorfaces: W
Performed for:
JENNIFERUOLg2
5502SEAGRME DPAE
Fr.PIERCE;R.34032
QUICK CALCS, INC..
317 ST. LUCIE LANE
FORT PIERCE, FL34946
QUCKCALCS@AOLCOM
Scale: 1 : 60
Page 1
RIgM-Suik®UnNersal2019
19.0.07RSU08101
2020-Feks040SO004
_hisoftFNACMYLCR,JENNIFERrUp