HomeMy WebLinkAboutProduct Approval EVALUATION REPORT OF
METAL SALES MANUFACTURING CORPORATION
`26 GA. 5V-CRIMP PANEL'
FLORIDA BUILDING CODE 6TH EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 14645.3-R3
ROOFING
METAL ROOFING
Prepared For:
Metal Sales Manufacturing Corporation
545 South 3rd Street, Suite 200
Louisville, KY 40202
Telephone: (502) 855-4300
Fax: (502) 855-4200
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer#62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (866) 366-1543
This report consists of
Evaluation Report (3 Pages including cover) `�®1j;j 111ti f
C Installation Details (1 Page) e�.� SO C K... ®s6
No 62240 a
• STATE OF
Report No. C2182-3 O••• ,� P .•
Date: 9.9.17 ®'.®FSS 0o ' •`;•���;''
O L",010-3
AL
�==--
File Copy `0
f
FL 14645.3-R3
C2182-3
9.9.17
Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Product Name: 5V-Crimp
Panel Description: 24" wide coverage with (5) 1/2" high ribs
Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792) or painted steel (ASTM A755).
Deck Description: Min. 19/32" plywood or min. 3/4" thick wood plank (min SG of 0.42)
for new and existing constructions. Designed by others and installed
as per FBC 2017.
Deck Attachment: 8d x 2.5" long ring shank nails or#8 x 2" long wood screws @ 6" o.c.
(Minimum) in the field and @ 4" o.c. at edges. Designed as per FBC 2017.
New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1.
Required for new construction and optional for reroofing construction.
Existing Underlayment: One layer of asphalt shingles over one layer of#30 felt. For reroofing
(Optional) construction only.
Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2.
Requires applied lap sealant for roof slopes less than 3:12.
Design Uplift Pressure: 41.6 psf @ fastener spacing of 36" o.c.
(Factor of Safety= 2) 74.8 psf @ fastener spacing of 16" o.c.
196.75 psf @ fastener spacing of 8" o.c.
Fastener Pattern:
Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener
shall be of sufficient length to penetrate through the deck a minimum
5;
of 3/8".
At panel ends @ 6" o.c. across panel width
At intermediate @ 12" o.c. across panel width
Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard
Requirements for Metal Roofing Systems'.
Code Compliance: The product described herein has demonstrated compliance with FBC
2017 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum support spacing listed herein shall not be
exceeded. This evaluation report is not applicable in High Velocity
I
FL 14645.3-R3
C2182-3
9.9.17
Page 3 of 3
Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2017 Section 1505 and current
approved roofing materials directory or ASTM E108/UL790 report
from an accredited laboratory for fire ratings of this product.
Supporting Documents: TAS 125 Test Reports
Farabaugh Engineering and Testing Inc
Project No. T181-05, Reporting Date 7/21/05 (Tests #1 & 2)
Project No. T240-09, Reporting Date 9/22/09
Architectural Testing, Inc. —West Palm Beach, FL
(Formerly Hurricane Test Laboratory, LLC)
Project No. 0103-0712-09, Reporting Date 9/1/09
K"
DRAWN BY: CNECK f BY;
B.S. D.S.
PLAT: DAS//13/13
NEW UNDERLAYMENT FASTENER AT PANEL FLAT 5V-CRIMP H
EXISTING SHINGLES SEE DETAIL 2 SEE DETAIL 'I (REQUIRED ONLY FOR REQUIRED FOR PANEL g
(OPTIONAL) /,- (PANEL OVERLAP) NEW CONSTRUCTION) ENDS ONLY.
u � o
EXISTING UNDERLAYMENT MINIMUM ATTACHMENTPANEL FASTENER PER ALLOWABLE
:
(OPTIONAL) PRESSURE TABLE ON THIS SHEET. o
8d x 2.5" LONG RING SHANK NAIL
OR #8 x 2" LONG WOOD SCREWS
SPACED ® 6" O.C. IN THE FIELD &
d
MIN. 2X- WOOD'RAFTER/JOIST/ 4" O.C. AT PLYWOOD EDGES
TRUSS AT MAX. 24" O.C.
a
TYPICAL PANEL INSTALLATION X—SECTION . 0 N
C7 UJ C-4
Z t=o
DN
Ln 0
#9-16 OR #10-14 WOODSCREWS ALLOWABLE UPLIFT PRESSURE �Y�I
NEW UNDERLAYMENT WITH SELF SEALING WASHER AT owe
(REQUIRED ONLY FOR MAXIMUM SPACING OF 36" O.C. FASTESPACNER NG PRESSURE J ro
NEW CONSTRUCTION) (IN) (PSF) �zN�
5V-CRIMP 36 41 6 0O
EXISTING SHINGLES MIN 26 GA.
(OPTIONAL) Ri
1:
16 74.8 .0
I Z- 8 196.75
4i
w
C3
EXISTING UNDERLAYMENT o
(OPTIONAL) PLYWOOD a a dem
19/32" THICK (MIN.) GENERAL NOTES:
DETAIL 1 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE 0
FLORIDA BUILDING CODE (FBC).
Z
2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.0169"). EFFECTIVE COVERING
9-16 OR 10-14 WOODSCREWS WIDTH OF PANEL = 24". :dam
# # 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE ASN e
NEW UNDERLAYMENT WITH SELF SEALING WASHER AT SPECIFIED ON THIS DRAWING. - w
(REQUIRED ONLY FOR MAXIMUM SPACING OF 36" O.C. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS - c
NEW CONSTRUCTION) PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS 0 €
ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING.
EXISTING SHINGLES 5V-CRIMP 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
(OPTIONAL) MIN 26 GA. BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL.
6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
EXISTING UNDERLAYMENT PLYWOOD
(OPTIONAL) 19/32" THICK (MIN.) 282-3
DETAIL2 SHEET N.
� of 1
30/30/2010 Florida Building Code Online
Business & Professional Regulation
i;
aCIS Home Log in User Re&tra-Uon Hot Tap16 I SubmItSurcharge Stats&Facts PublimUons eontaa Us] BCIS M Map
0Pradnct�pprogpl
OlER.iibfk-rJmr.':
Prod%t Aooroval Menu>Product or 6pRH Von Search>epogcatlon Ust>Application DaUff
NEI = FL# FL16048-R6
- Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived ( ;
Product Manufacturer 'til-Built Materials Group,LLC
Address/Phone/Email PO Box 70
Rutherford,NJ 07070
(800)516-1485
david.ruiz@tribuiltmg.com
Authorized Signature David Ruiz
david.ruli@tribuilbmg.com
Technical Representative David Ruiz
Address/Phone/Email 250 Route 17 North
East Rutherford,N3 07073
(201)842-2449
david.ruiz@tribuiltmateriaisgroup.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underiayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Ucensed Florida.
Professional Engineer
r� Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nleminen
Evaluation Report
Florida Ucense PE-59166
Quality Assurance Entity
- -- -- - -------— ---
Qualiity Assurance Contract Expiration Date 07/182020
Validated By John W.Knezevich,PE
W Validation Checklist-Hardcopy Received
Certificate of Independence FL16048 R6 COI 2017 01 COI Nieminen pd
Referenced Standard and Year(of Standard) Standard year
ASTM D1970 2015 .
ASTM 6155 2005
FM 4474 2011
FRSA/TRI April 2012(04-12) 2012
UL 1897 2012
Equivalence of Product Standards °
Certified By � �� O
https://floridabuilding.org/pr/pr app dtl.aspx7param=wGEVXQwtDgtFPmdYINDWrwipmtAnR8jvgFYHTk4FLCxogVtRhfvMw°/a3d%3d 1/2
10/30/2019' Florida Building Code Online
7
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 09/25/2017
Date Validated 10/01/2017
Date Pending FBC Approval 10/03/2017
Date Approved 12/12/2017
Summairy of Products
'FL# Model,Number or Name Description
;16048.1 TRI-BUILT Roof Underiayments Self-adhering,modified bitumen roof underiaymerlts
.Limits of Use
Installatlon Instrurotlons.
Approved for use In HVHZ:No FL16048 116111-2017 OS:FINAL ER TR1-
Approved for use outside HVHZ:Yes BUILT.UNDERLAYMENTS F-(,16048=R6 odf
Impact Resistant:N/A Verified sy:-Robert'Niemirien PE-59166
Design Pressure:+N/A/-150 Created by Independent Third Party:Yes
Other:1.)The design pressure noted herein pertains to use of Evaluation Reports.
foam-on tile systems overtop the self-adhering underlayment F1�.6048 R6 AE 2017 09 FINAL ER TRI-
for one particular application.See ER Section 5.6.4 for details. I�UILT UNDE AE 2017 FINALE Ddf
2.)Refer to ER Section 5 for other Limits of Use. Created by Independent Third Party.Yes
- -- .
aack Next
.Contact Us::2601 Blair Stone Road,Tallahassee Fl.32399-�hgne:850+487-1824
The State of Florida Is an AA/EEO employer. tate-of Florida ::privacy Statement;;A_ccessibllitV Statement::Refund 5,tatement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees Iicensed'under Chapter 455,F.S.must provide the Department with an email address if they have one.The emans
provided may be used for official communication with the licensee.However-emali addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,FS.,please click here.
NO;t
prodtircfylpjit�oval.Aeeepts:
Cledd.Card
Safe-
https:flfloridabu.ilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgtFPmdYNDWrwipmtAnR8jv9FIYHTk4FLCxcgVtRhfvMw%3d%3d 212
1
EXTERIOR RESEARCH&DESIGN,I.I.C.
Certificate of Authorization#9503
fRINITY 353 CHRISTIAN STREET,UNIT#13
QoJERD OXFORD,CT 06478
(203)262-9245
EVALUATION REPDRT
TRI-BUILT Materials Group,LLC Evaluation Report A42960.10.12-R6
PO Box 70 FL16048-R6
Rutherford,NJ 07070 Date of Issuance:10/25/2012
(800),516-1485 Revision 6: 09/25/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The-
products described herein have been evaluated for compliance with the 6"t Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LASEUNG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPUANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced'
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
.'11A 3„
1
Robert J.M.Nieminen,P.E.
,,,,r,,,�• The facsimile seal appearing was authorized by Hobert Nleminen,
Florida RE No.59166,Florida DCAANE1983 P.E.on 09/25/2017.Thlsdoes not serve asanelectronirdlly-signed
CERTIFICATION OF INDEPENDENCE:.
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5.. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
OTIRU.Nffy ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have
demonstrated compliance with the following sections of the Sei Edition(2017)Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the installation Requirements and Limitations/
. Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Resistance FM 4474 2011
15043.1 Wind Uplift UL 1897 2012
1504.6 Accelerated Weathering ASTM G155 2005
1507.2.4/1507.1.1,2507.2.9.2 Physical Properties ASTM D1970 2015
1507.3.3 Physical Properties FRSA/TRI April 2012(04-12) 2012
3. REFERENCES:
Entity Examination Reference. Date
ERD(TST6049) Physical Properties 540540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties S40540.11.13 11/19/2013
ERD(TST6049) Physical Properties S40540.03.14 03/26/2014
ERD(TST6049) Physical Properties. S44870.04-14-2 04/02/2014
ERD(TST6049) Physical Properties 544870.04.14-3 04/02/2014
ERD(TST6049) Physical Properties S44870.04.14-1 04/10/2014
ERD(TST6049) Physical Properties 544870.04.14-4 04/10/2014
ERD(TST6049) Physical Properties S43530.02.14-1-R1 05/14/2014
ERD(TST6049) Physical Properties 543530.05.14 05/28/2014
ERD(TST6049) Physical Properties 540540.10.14 10/31/2014
ERD(TST6049) Physical Properties SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SC8520.04.15 05/27/2015
ERD(TST6049) Wind Resistance SC14045.05.17-R1 06/07/2017
UL,U.C.(QUA9625) Quality Control Multiple-Listing 816814 12/10/2015
UL,I.I.C.(QUA9625) Quality Control Service Confirmation Exp.07/18/2020
4. PRODUCT DESCRIPTION:
4.1 Tri-Built Sand-R SA Shingle Underlayment is a self-adhering, glass-mat reinforced, sand-surfaced, SBS
modified bitumen roof underlayment,with a 36-inch sheet width;meets ASTM D1970.
4.2 Tri-Built S/A HT TU Underlayment is a self-adhering, non=woven polyester fabric surfaced,SBS modified
bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI April 2012.
A7UUhder a my ent Is -a self-adhering, glass-mat- reinforced, flim-surfaced, SBS
modified bitumen roof underlayment;meets ASTM D1970.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use In FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design,LCC. Evaluation Report A42960.10.12-R6
Certificate of Authorization#9503 6r"EDITION(2017)FBC NON-HVHZ EVALUATION F1.16048-R6
TRI-BUILT Roof Underlayments;(800)515-1485 Revision 6:09125/2017
Page 2 of 6
OTP..,1NffYjERD
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is .
specifically referenced within FBC approval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.5 Allowable.Roof.Covers:
Underly Asphalt Wood Shakes
ymerrt Nall-On The , Foam-On Tile Metal Slate
Shingles &Shingles
Till Sand-R SA Shingle
Underlayment Yes No No No Yes Yes
Tri-Built S/A HT TU Yes
Yes Yes Yes Yes Yes
Underlayment See 5.5.1
Tri Bulit,Smooth HTS/A Yes No No Yes Yes Yes
Underlayment
5.5.1- "Foam-On Tile"is limited to use of the following Approved tile adhesives/underlayment combinations.
I` _ " Ti►11s �M ow
n% �iloEnu►y�i"ENConno"s � �'
__... . ... ------
Florida .
Adhesive Product Approval Underiayments
ICP Adhesives Polyset"AH-160 FL6332 Tri-Built S/A HT TU Underlayment
Dow'I ileBorld"'' FL22525 Tri-Built S/A HT TU Underlayment
5.6 Allowable Substrates_:
5.6.1 Direct-Bond to Deck:
Tri-Built Sandi SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Till Smooth HT S/A
Underlayment applied to:
➢ Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41
primed Southern Yellow Pine;ASTM D41 primed structural concrete.
While not required over plywood,OSB or Southern Yellow Pine substrates,TRI-BUILT Materials Group,LLC
recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note:
TRI-BUILT Materials Group, LLC requires tongue-and-groove board decking be covered with plywood or
OSB prior to installation of the self-adhering underlayment.
5.6.2 Bond-to-Insulation:
Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board.
.-€or_mstallatior>--unde--mechanicaff --attached-prepared-roof-coverings—insuiation-shall-be attaaired=per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be
designed by a qualified design professional and installed based_ on testing of the insulation/underlayment
system in accordance with FM 4474 Appendix pp ndix D or TAS 114,Appendix J.
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R6
CertUlcate of Authorization#9503 67 EDITION(2017)FBC NON-HVHZ EVALUATION I'L16048-R6
TRI-BUILT Roof Underlayments,(800)516-1485 Revision 6:09/25/2017
Page 3 of 6
Q0ira1N1TY1ERD
5.6.3 Bond to Mechanically Attached Base Laver.
Tri-Built Sand-IR SA Shingle Underlayment,Tri-Suitt S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ ASTM D226,Type I or 11 felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on tile systems (Tri-Built S/A HT TU
Underlayment only),base layer shall be attached per minimum requirements of FRSA/TRI April 2012(04-
ii
12}.
5.6.4 Wind Resistance for Underlayment Systems in-Foam-On Tile Abolications; FRSA/TRi April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on the systems,where
the underlayment forms part of the load-path. The following wind uplift limitations apply to direct=deck
underlayment systems that are not addressed In FRSA/TRI April 2012(04-12)and are used in foam-on file
applications. Maximum Design Pressure is the result of testing for wind load resistance.based on
allowable wind loads,and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety.
per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12),Appendix A,Table 1A or
FBC 1609 for determination of design wind pressures.
Al Maximum Design Pressure=-45.0-usf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional)ASTM D41 or RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A HT TU Undedayment,self-adhered.
j #2 Maximum Dess`an Pressure=-67.5 psf:.
I Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
_ Primer: Soprema Elastocol 600c
Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered.
#3 Maximum Design Pressure=-150.0 psf;
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation:Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
i adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp
` splinters and wood projections shall be removed/sanded.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A HT TU Underlayment, self-adhered, shall be thoroughly roll using hand
roller and/or weighted roller to ensure there are no voids, and ensure there are no
voids/bridging at side and end-laps.
#4 Maximum Design Pressure=-60.0 Psi:
In:- 9-/32=-IncTi-plywoa o meg project requirements-to satisfaction ofAuthority
Having Jurisdiction.
Base Sheet: Soprema Sopra-6 or Modified Sopra-G mechanically attached with halls (FBC 1517.5.1)
and tin caps(FBC 1517-5.2)spaced 6-inch o.c.at the 4-Inch laps and 6-inch o.e.in three,
equally spaced rows in the center of the sheet.
Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered.
I
Exterior Research and Design,U.C. Evaluation Report A42960.10.12-R6
Certificate of Authorization#9503 6"'EDITION(2017)FBC NON-HVH2 EVALUATION FL16046-R6
TRI-BUILT Roof Underiayments;(800)5164485 Revision 6:09/2512017
Page 4 of 6
QOTPtINITYIERD
5.6.4.1 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application.Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Tri-Built Sand-11 SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30-days after installation
Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation.
5.8 Tile:Sli00ake:Limitations'(TAS 103 Qer FRSA/TRI Abril 2012104-121)
When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
x .rnaa z rT L SLIPET! ttDEq��I N57 D SP1 `
Underlayment Tile Profile Staging Method Maximum
._Slope__
Flat Max.10-tile stack 6:12
Lugged .Max.16-tile stack 5:12
Max.10-tile stack(bottom 2-tile stack
shall be inverted,followed by 8 tiles high 6:12-
-..--on
:12_-._on slope„as shown below)
r t
s
Tri-Built S/A HT TU
Underlayment
Lugged
Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R6
Certificate of Authorization#9503 67H EDITION(2017)FBC NON-HVH2 EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6.09/2S/2017
Page 5 of 6
`fRJN11Y�ER
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC
published installation requirements subject to the Limitations set forth in Section S herein and the
specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads; Sweep the substrate thoroughly
to remove any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Tri Built Sand-R SA Shingle Underlayinent•Trl-Built SIA HT TIJ_UnderI16Lmentor Trii-Built.Smooth HT SIA
6.3.1 Shall be installed in compliance With the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be Installed.
6.3.2 Non Tile applications:
While priming Is optional,TRI-BUILT Materials Group,LLC recommends priming the deck if the final roof
cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 It of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the
membrane tight. Firmly roll,broom or hand-press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below,sealed in accordance with
TRI-BUILT Materials Group,LLC requirements.
When installing at slopes above 8:12,TRI-BUILT Materials Group, LLC recommends back-nailing in the
overlap area at the top of the sheet at 12-inch o.c.
For Valleys and Ridges: Cut undeflayment Into 4 to 6 foot lengths.Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys,apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications(Tri-Built S/A HT TULInderlayment onlvi
Reference Is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam-on tile applications,reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRl April 2012(04-12).
Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to the
underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile
staging.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to property evaluate the Installation of
this product.
8. MANUFACTURING PLANTS:
Gulfport,MS
9. QUALITY ASSURANCE ENTITY:
UL,LLC--QUA9625;(314)578-3406;k.chancellor@us.ul.com-
END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report A42960.20.12-116
Certificate of Authorization#9503 6T"EDITION(201.7)FBC NON-HVHZ EVALUATION FLI6049-R6
TRI-BUILT Roof Underlayments,(800)516-2465 Revision 6:09/25/2017
Page 6 of 6
l Lr
! � 4
4'l
_l
a