HomeMy WebLinkAboutProduct Approval EVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION `26 GA. 5V-CRIMP PANEL' FLORIDA BUILDING CODE 6TH EDITION (2017) FLORIDA PRODUCT APPROVAL FL 14645.3-R3 ROOFING METAL ROOFING Prepared For: Metal Sales Manufacturing Corporation 545 South 3rd Street, Suite 200 Louisville, KY 40202 Telephone: (502) 855-4300 Fax: (502) 855-4200 Prepared By: Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer#62240 1216 N Lansing Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 FAX: (866) 366-1543 This report consists of Evaluation Report (3 Pages including cover) `�®1j;j 111ti f C Installation Details (1 Page) e�.� SO C K... ®s6 No 62240 a • STATE OF Report No. C2182-3 O••• ,� P .• Date: 9.9.17 ®'.®FSS 0o ' •`;•���;'' O L",010-3 AL �==-- File Copy `0 f FL 14645.3-R3 C2182-3 9.9.17 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: 5V-Crimp Panel Description: 24" wide coverage with (5) 1/2" high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 19/32" plywood or min. 3/4" thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2017. Deck Attachment: 8d x 2.5" long ring shank nails or#8 x 2" long wood screws @ 6" o.c. (Minimum) in the field and @ 4" o.c. at edges. Designed as per FBC 2017. New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1. Required for new construction and optional for reroofing construction. Existing Underlayment: One layer of asphalt shingles over one layer of#30 felt. For reroofing (Optional) construction only. Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Design Uplift Pressure: 41.6 psf @ fastener spacing of 36" o.c. (Factor of Safety= 2) 74.8 psf @ fastener spacing of 16" o.c. 196.75 psf @ fastener spacing of 8" o.c. Fastener Pattern: Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener shall be of sufficient length to penetrate through the deck a minimum 5; of 3/8". At panel ends @ 6" o.c. across panel width At intermediate @ 12" o.c. across panel width Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum support spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity I FL 14645.3-R3 C2182-3 9.9.17 Page 3 of 3 Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: TAS 125 Test Reports Farabaugh Engineering and Testing Inc Project No. T181-05, Reporting Date 7/21/05 (Tests #1 & 2) Project No. T240-09, Reporting Date 9/22/09 Architectural Testing, Inc. —West Palm Beach, FL (Formerly Hurricane Test Laboratory, LLC) Project No. 0103-0712-09, Reporting Date 9/1/09 K" DRAWN BY: CNECK f BY; B.S. D.S. PLAT: DAS//13/13 NEW UNDERLAYMENT FASTENER AT PANEL FLAT 5V-CRIMP H EXISTING SHINGLES SEE DETAIL 2 SEE DETAIL 'I (REQUIRED ONLY FOR REQUIRED FOR PANEL g (OPTIONAL) /,- (PANEL OVERLAP) NEW CONSTRUCTION) ENDS ONLY. u � o EXISTING UNDERLAYMENT MINIMUM ATTACHMENTPANEL FASTENER PER ALLOWABLE : (OPTIONAL) PRESSURE TABLE ON THIS SHEET. o 8d x 2.5" LONG RING SHANK NAIL OR #8 x 2" LONG WOOD SCREWS SPACED ® 6" O.C. IN THE FIELD & d MIN. 2X- WOOD'RAFTER/JOIST/ 4" O.C. AT PLYWOOD EDGES TRUSS AT MAX. 24" O.C. a TYPICAL PANEL INSTALLATION X—SECTION . 0 N C7 UJ C-4 Z t=o DN Ln 0 #9-16 OR #10-14 WOODSCREWS ALLOWABLE UPLIFT PRESSURE �Y�I NEW UNDERLAYMENT WITH SELF SEALING WASHER AT owe (REQUIRED ONLY FOR MAXIMUM SPACING OF 36" O.C. FASTESPACNER NG PRESSURE J ro NEW CONSTRUCTION) (IN) (PSF) �zN� 5V-CRIMP 36 41 6 0O EXISTING SHINGLES MIN 26 GA. (OPTIONAL) Ri 1: 16 74.8 .0 I Z- 8 196.75 4i w C3 EXISTING UNDERLAYMENT o (OPTIONAL) PLYWOOD a a dem 19/32" THICK (MIN.) GENERAL NOTES: DETAIL 1 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE 0 FLORIDA BUILDING CODE (FBC). Z 2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.0169"). EFFECTIVE COVERING 9-16 OR 10-14 WOODSCREWS WIDTH OF PANEL = 24". :dam # # 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE ASN e NEW UNDERLAYMENT WITH SELF SEALING WASHER AT SPECIFIED ON THIS DRAWING. - w (REQUIRED ONLY FOR MAXIMUM SPACING OF 36" O.C. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS - c NEW CONSTRUCTION) PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS 0 € ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. EXISTING SHINGLES 5V-CRIMP 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA (OPTIONAL) MIN 26 GA. BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. EXISTING UNDERLAYMENT PLYWOOD (OPTIONAL) 19/32" THICK (MIN.) 282-3 DETAIL2 SHEET N. � of 1 30/30/2010 Florida Building Code Online Business & Professional Regulation i; aCIS Home Log in User Re&tra-Uon Hot Tap16 I SubmItSurcharge Stats&Facts PublimUons eontaa Us] BCIS M Map 0Pradnct�pprogpl OlER.iibfk-rJmr.': Prod%t Aooroval Menu>Product or 6pRH Von Search>epogcatlon Ust>Application DaUff NEI = FL# FL16048-R6 - Application Type Revision Code Version 2017 Application Status Approved Comments Archived ( ; Product Manufacturer 'til-Built Materials Group,LLC Address/Phone/Email PO Box 70 Rutherford,NJ 07070 (800)516-1485 david.ruiz@tribuiltmg.com Authorized Signature David Ruiz david.ruli@tribuilbmg.com Technical Representative David Ruiz Address/Phone/Email 250 Route 17 North East Rutherford,N3 07073 (201)842-2449 david.ruiz@tribuiltmateriaisgroup.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underiayments Compliance Method Evaluation Report from a Florida Registered Architect or a Ucensed Florida. Professional Engineer r� Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nleminen Evaluation Report Florida Ucense PE-59166 Quality Assurance Entity - -- -- - -------— --- Qualiity Assurance Contract Expiration Date 07/182020 Validated By John W.Knezevich,PE W Validation Checklist-Hardcopy Received Certificate of Independence FL16048 R6 COI 2017 01 COI Nieminen pd Referenced Standard and Year(of Standard) Standard year ASTM D1970 2015 . ASTM 6155 2005 FM 4474 2011 FRSA/TRI April 2012(04-12) 2012 UL 1897 2012 Equivalence of Product Standards ° Certified By � �� O https://floridabuilding.org/pr/pr app dtl.aspx7param=wGEVXQwtDgtFPmdYINDWrwipmtAnR8jvgFYHTk4FLCxogVtRhfvMw°/a3d%3d 1/2 10/30/2019' Florida Building Code Online 7 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/25/2017 Date Validated 10/01/2017 Date Pending FBC Approval 10/03/2017 Date Approved 12/12/2017 Summairy of Products 'FL# Model,Number or Name Description ;16048.1 TRI-BUILT Roof Underiayments Self-adhering,modified bitumen roof underiaymerlts .Limits of Use Installatlon Instrurotlons. Approved for use In HVHZ:No FL16048 116111-2017 OS:FINAL ER TR1- Approved for use outside HVHZ:Yes BUILT.UNDERLAYMENTS F-(,16048=R6 odf Impact Resistant:N/A Verified sy:-Robert'Niemirien PE-59166 Design Pressure:+N/A/-150 Created by Independent Third Party:Yes Other:1.)The design pressure noted herein pertains to use of Evaluation Reports. foam-on tile systems overtop the self-adhering underlayment F1�.6048 R6 AE 2017 09 FINAL ER TRI- for one particular application.See ER Section 5.6.4 for details. I�UILT UNDE AE 2017 FINALE Ddf 2.)Refer to ER Section 5 for other Limits of Use. Created by Independent Third Party.Yes - -- . aack Next .Contact Us::2601 Blair Stone Road,Tallahassee Fl.32399-�hgne:850+487-1824 The State of Florida Is an AA/EEO employer. tate-of Florida ::privacy Statement;;A_ccessibllitV Statement::Refund 5,tatement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees Iicensed'under Chapter 455,F.S.must provide the Department with an email address if they have one.The emans provided may be used for official communication with the licensee.However-emali addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,FS.,please click here. NO;t prodtircfylpjit�oval.Aeeepts: Cledd.Card Safe- https:flfloridabu.ilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgtFPmdYNDWrwipmtAnR8jv9FIYHTk4FLCxcgVtRhfvMw%3d%3d 212 1 EXTERIOR RESEARCH&DESIGN,I.I.C. Certificate of Authorization#9503 fRINITY 353 CHRISTIAN STREET,UNIT#13 QoJERD OXFORD,CT 06478 (203)262-9245 EVALUATION REPDRT TRI-BUILT Materials Group,LLC Evaluation Report A42960.10.12-R6 PO Box 70 FL16048-R6 Rutherford,NJ 07070 Date of Issuance:10/25/2012 (800),516-1485 Revision 6: 09/25/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The- products described herein have been evaluated for compliance with the 6"t Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: TRI-BUILT Roof Underlayments LASEUNG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPUANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced' Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: .'11A 3„ 1 Robert J.M.Nieminen,P.E. ,,,,r,,,�• The facsimile seal appearing was authorized by Hobert Nleminen, Florida RE No.59166,Florida DCAANE1983 P.E.on 09/25/2017.Thlsdoes not serve asanelectronirdlly-signed CERTIFICATION OF INDEPENDENCE:. 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5.. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. OTIRU.Nffy ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have demonstrated compliance with the following sections of the Sei Edition(2017)Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the installation Requirements and Limitations/ . Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2011 15043.1 Wind Uplift UL 1897 2012 1504.6 Accelerated Weathering ASTM G155 2005 1507.2.4/1507.1.1,2507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012(04-12) 2012 3. REFERENCES: Entity Examination Reference. Date ERD(TST6049) Physical Properties 540540.02.13-1 02/19/2013 ERD(TST6049) Physical Properties S40540.11.13 11/19/2013 ERD(TST6049) Physical Properties S40540.03.14 03/26/2014 ERD(TST6049) Physical Properties. S44870.04-14-2 04/02/2014 ERD(TST6049) Physical Properties 544870.04.14-3 04/02/2014 ERD(TST6049) Physical Properties S44870.04.14-1 04/10/2014 ERD(TST6049) Physical Properties 544870.04.14-4 04/10/2014 ERD(TST6049) Physical Properties S43530.02.14-1-R1 05/14/2014 ERD(TST6049) Physical Properties 543530.05.14 05/28/2014 ERD(TST6049) Physical Properties 540540.10.14 10/31/2014 ERD(TST6049) Physical Properties SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SC8520.04.15 05/27/2015 ERD(TST6049) Wind Resistance SC14045.05.17-R1 06/07/2017 UL,U.C.(QUA9625) Quality Control Multiple-Listing 816814 12/10/2015 UL,I.I.C.(QUA9625) Quality Control Service Confirmation Exp.07/18/2020 4. PRODUCT DESCRIPTION: 4.1 Tri-Built Sand-R SA Shingle Underlayment is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,with a 36-inch sheet width;meets ASTM D1970. 4.2 Tri-Built S/A HT TU Underlayment is a self-adhering, non=woven polyester fabric surfaced,SBS modified bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI April 2012. A7UUhder a my ent Is -a self-adhering, glass-mat- reinforced, flim-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use In FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,LCC. Evaluation Report A42960.10.12-R6 Certificate of Authorization#9503 6r"EDITION(2017)FBC NON-HVHZ EVALUATION F1.16048-R6 TRI-BUILT Roof Underlayments;(800)515-1485 Revision 6:09125/2017 Page 2 of 6 OTP..,1NffYjERD 5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is . specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable.Roof.Covers: Underly Asphalt Wood Shakes ymerrt Nall-On The , Foam-On Tile Metal Slate Shingles &Shingles Till Sand-R SA Shingle Underlayment Yes No No No Yes Yes Tri-Built S/A HT TU Yes Yes Yes Yes Yes Yes Underlayment See 5.5.1 Tri Bulit,Smooth HTS/A Yes No No Yes Yes Yes Underlayment 5.5.1- "Foam-On Tile"is limited to use of the following Approved tile adhesives/underlayment combinations. I` _ " Ti►11s �M ow n% �iloEnu►y�i"ENConno"s � �' __... . ... ------ Florida . Adhesive Product Approval Underiayments ICP Adhesives Polyset"AH-160 FL6332 Tri-Built S/A HT TU Underlayment Dow'I ileBorld"'' FL22525 Tri-Built S/A HT TU Underlayment 5.6 Allowable Substrates_: 5.6.1 Direct-Bond to Deck: Tri-Built Sandi SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Till Smooth HT S/A Underlayment applied to: ➢ Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural concrete. While not required over plywood,OSB or Southern Yellow Pine substrates,TRI-BUILT Materials Group,LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT Materials Group, LLC requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-adhering underlayment. 5.6.2 Bond-to-Insulation: Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board. .-€or_mstallatior>--unde--mechanicaff --attached-prepared-roof-coverings—insuiation-shall-be attaaired=per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be designed by a qualified design professional and installed based_ on testing of the insulation/underlayment system in accordance with FM 4474 Appendix pp ndix D or TAS 114,Appendix J. 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R6 CertUlcate of Authorization#9503 67 EDITION(2017)FBC NON-HVHZ EVALUATION I'L16048-R6 TRI-BUILT Roof Underlayments,(800)516-1485 Revision 6:09/25/2017 Page 3 of 6 Q0ira1N1TY1ERD 5.6.3 Bond to Mechanically Attached Base Laver. Tri-Built Sand-IR SA Shingle Underlayment,Tri-Suitt S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ ASTM D226,Type I or 11 felt. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems (Tri-Built S/A HT TU Underlayment only),base layer shall be attached per minimum requirements of FRSA/TRI April 2012(04- ii 12}. 5.6.4 Wind Resistance for Underlayment Systems in-Foam-On Tile Abolications; FRSA/TRi April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on the systems,where the underlayment forms part of the load-path. The following wind uplift limitations apply to direct=deck underlayment systems that are not addressed In FRSA/TRI April 2012(04-12)and are used in foam-on file applications. Maximum Design Pressure is the result of testing for wind load resistance.based on allowable wind loads,and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety. per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12),Appendix A,Table 1A or FBC 1609 for determination of design wind pressures. Al Maximum Design Pressure=-45.0-usf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)ASTM D41 or RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HT TU Undedayment,self-adhered. j #2 Maximum Dess`an Pressure=-67.5 psf:. I Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. _ Primer: Soprema Elastocol 600c Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered. #3 Maximum Design Pressure=-150.0 psf; Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation:Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit i adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp ` splinters and wood projections shall be removed/sanded. Primer: (Optional)RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HT TU Underlayment, self-adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and ensure there are no voids/bridging at side and end-laps. #4 Maximum Design Pressure=-60.0 Psi: In:- 9-/32=-IncTi-plywoa o meg project requirements-to satisfaction ofAuthority Having Jurisdiction. Base Sheet: Soprema Sopra-6 or Modified Sopra-G mechanically attached with halls (FBC 1517.5.1) and tin caps(FBC 1517-5.2)spaced 6-inch o.c.at the 4-Inch laps and 6-inch o.e.in three, equally spaced rows in the center of the sheet. Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered. I Exterior Research and Design,U.C. Evaluation Report A42960.10.12-R6 Certificate of Authorization#9503 6"'EDITION(2017)FBC NON-HVH2 EVALUATION FL16046-R6 TRI-BUILT Roof Underiayments;(800)5164485 Revision 6:09/2512017 Page 4 of 6 QOTPtINITYIERD 5.6.4.1 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application.Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 5.7 Exposure Limitations: Tri-Built Sand-11 SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left exposed for longer than 30-days after installation Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation. 5.8 Tile:Sli00ake:Limitations'(TAS 103 Qer FRSA/TRI Abril 2012104-121) When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. x .rnaa z rT L SLIPET! ttDEq��I N57 D SP1 ` Underlayment Tile Profile Staging Method Maximum ._Slope__ Flat Max.10-tile stack 6:12 Lugged .Max.16-tile stack 5:12 Max.10-tile stack(bottom 2-tile stack shall be inverted,followed by 8 tiles high 6:12- -..--on :12_-._on slope„as shown below) r t s Tri-Built S/A HT TU Underlayment Lugged Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R6 Certificate of Authorization#9503 67H EDITION(2017)FBC NON-HVH2 EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6.09/2S/2017 Page 5 of 6 `fRJN11Y�ER 6. INSTALLATION: 6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC published installation requirements subject to the Limitations set forth in Section S herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads; Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Tri Built Sand-R SA Shingle Underlayinent•Trl-Built SIA HT TIJ_UnderI16Lmentor Trii-Built.Smooth HT SIA 6.3.1 Shall be installed in compliance With the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be Installed. 6.3.2 Non Tile applications: While priming Is optional,TRI-BUILT Materials Group,LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 It of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane tight. Firmly roll,broom or hand-press the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below,sealed in accordance with TRI-BUILT Materials Group,LLC requirements. When installing at slopes above 8:12,TRI-BUILT Materials Group, LLC recommends back-nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut undeflayment Into 4 to 6 foot lengths.Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys,apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications(Tri-Built S/A HT TULInderlayment onlvi Reference Is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam-on tile applications,reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRl April 2012(04-12). Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to the underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile staging. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to property evaluate the Installation of this product. 8. MANUFACTURING PLANTS: Gulfport,MS 9. QUALITY ASSURANCE ENTITY: UL,LLC--QUA9625;(314)578-3406;k.chancellor@us.ul.com- END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report A42960.20.12-116 Certificate of Authorization#9503 6T"EDITION(201.7)FBC NON-HVHZ EVALUATION FLI6049-R6 TRI-BUILT Roof Underlayments,(800)516-2465 Revision 6:09/25/2017 Page 6 of 6 l Lr ! � 4 4'l _l a