Loading...
HomeMy WebLinkAboutProduct Approval FLA h9anufae;ured BWdrg Prcgrrn gushes �'� 119:0 forth monrcesireet Swe 90A, Profesna I Telahassee. Ronda 32389-6772 RIC—i,. y_ Pbrone 850 48T 11824• fax 050 4-5.'8436 Ken Lawson,SecreWy Rick Scott,Govemor February 28,2019 Tom Saurey Tuff Shed,Inc.. 1777 South Harrison Street,Suite 600 Denver,CO 80210 RE: Manufacturer Certification,ID MFT-7686; Expiration Date: February 14,2022 Dear Tom Saurey It is my pleasure to inform you that Tuff Shed,Inc.., located at 1919 NW 19th Street,Suite 301, Store 530, Ft. Lauderdale, FL 33311,has been approved under the Manufactured Buildings Program,as provided for under Chapter 553, Part I, Florida Statutes,to manufacture Storage Sheds for installation in Florida. Construction or modification on a manufactured building cannot begin until the Third Party Agency has approved the plans in accordance with the current Florida Building Code. Your Third Party Agency is a contractor for the Department and has statutory authority and responsibilities that must be met to maintain approved status.You may expect and demand quality plans review and inspections. Each Code change will make your plans obsolete until they have been reviewed,approved and indicated[on the cover page of the plans)for compliance with the Code by your Third Party Agency for plans review. Please ensure that your plans are in compliance and are properly posted on our website.All site-related installation issues are subject to the local authority having jurisdiction. The Department's contractor will make unannounced monitoring visits at least once each year. You must grant complete access to your manufacturing facility and records to remain in compliance with the rules and regulations of this program. Your certification is approved for three years from this date. You will receive a renewal notice by Email generated by the BCIS(www.floridabuilding.org)for online renewal.If you have questions you may contact Robert Lorenzo at 850-717-1835 or our FAX at 850-414-8436. Please visit our website at www.florid abuildinU.orn to see valuable information on the Florida Manufactured Buildings Program.A copy of this letter must accompany applications for local building permits. Sincerely, Robert Lorenzo Manufactured Buildings Program cc:Top Line Engineering, LLC CONTRACTOR COPY aOL 1/31/2020 Florida Building Code Online •�`� lit ' BCIS Home Log In User Registration Hot Topics ( Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map' Links I Search, b ,- a t rl Manufactured(Modular)Buildings USER:Public User 7.kr�.•lL'Fi'v'bfi: Manufactured(MDAujkr)_Lujjdjngs Menu>Plan Search>Plan L st>Plan Detail Plan Tracking# 34889 Code Version 2017 Building Type Storage Sheds Municipal Jail No Manufacturer Tuff Shed,Inc.. Agency Top Line Engineering, LLC Agency Plan# TSR7-812S 160 MPH School District Contract Agency Construction Type V-B Fire Protection B Fire Suppression System No Occupancy Utility-Mist. Allowable#of Stories 1 Wind Velocity 160 mph Exposure C Fire Rating of Exterior Walls 0 hrs Area Live-psf Dead-psf Maximum Floor Load 55 55 10 Alternate Maximum Floor Load Roof Load 30 10 "R" Rating of Floor,Wall,and Roof 0,0,0 Modules per Building 1 Square Footage 150 Sq. Ft. Approved for Hurricane Protection Usage No Designed for use as a Hurricane Public Shelter No Comments Residential Lawn Storage Shed New Construction for submittal please.W. Neary,III Plans Examiner(SMP-51). Thank you! Original Plan Tracking# Date of Agency Approval 03/04/2019 Date Submitted 03/05/2019 Date Accepted 03/12/2019 Status Accepted Date Attached File 03/05/2019 PlanID 34889 TSR7-8125 160 MPH COVER LETTER-a8283361.Ddf 03/11/2019 PlanID 34889 TSR7-812S 160 MPH-9661aab3 Pdf Cancel Plan Reviews Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your a-mall address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Manufactured(Modular)Buildings Accepts: ® .e_Check hftps://www.floridabuilding.org/mb/mb_pub_Plan_dtl.aspx?param=OgQwMGULGpxldgyl5JSEA4B3nl Q%a2f2OGXBCZzCvIKUWhQgX1 Ffk6%2bT3faG... 1/2 I >]ETOP LINE ENGINEERING LLC STRUCTURAL ENGINEERS March 4, 2019 Mr. Thomas Campbell Florida Department of Business and Professional Regulation 2601 Blair Stone Road Building C Tallahassee, Florida 32399-6563 RE: Plan Approval Tuff Sheds, Inc. Plan #TSR7-812S 160 MPH Dear Mr. Campbell, Per the requirements of the Florida Department of Business and Professional Regulations,the above referenced plans have been reviewed for compliance with: 2017 Florida Building Code, 6th Edition 2014 National Electrical Code (NFPA-70) These plans comply with Florida Product Approval Rule 61 G20-3.006 (FAC) A signed and sealed set of plans are maintained on file with Topline Engineering, LLC. All mandatory comments have been satisfied and plans are approved for construction by a currently approved modular building manufacturer. If you have any questions or require my assistance in any way, please do not hesitate to contact me. Thank you. Respectfully, William E. Neary, III Business Partner Topline Engineering, LLC BILL.TLE@yahoo.com 10649 Oakview Pointe Terrace a Gotha• FL 34734• Phone(407)421-4037• Projects.TLE@yahoo.com FL Certificate of Authorization 31785 MANUFACTURED STORAGE SHED bErTwc uMINU ER}LLC FOR SHEDS UP TO 8'X12' FOOTPRINT AND UP TO T WALL HEIGHT William E.Neary,III ROOF PITCH BETWEEN 2:12 AND 6:12 SMP-51,SMI-79,ICC 5185040 10649 Oakview Pointe Terrace MIAMI-DADE NOA AND FL Gotha,Florida 34734 PRODUCT APPROVAL WITH HVHZ DESIGN REQUIREMENTS SHEET INDEX MIAMI-DADE NOA: BUILDING CODE 2017 FBC 6TH EDITION ELECTRICAL CODE 2014 NEC NFPA 70 SHEET 1-GENERAL DESIGN REQUIREMENTS 1. PRIMESOURCE BUILDING PRODUCTS RING SHANK NAILS-MIAMI BUILDING TYPE RESIDENTIAL LAWN STORAGE SHED DADE NOA#17-0821.08 OR APPROVED EQUIVALENT. MANUFACTURER TUFF SHED INC. SHEET 2-FLOOR DESIGN 2. ECO WINDOW SYSTEMS,LLC WINDOWS-MIAMI-DADE NOA AGENCY TOPLINE ENGINEERING LLC #17-1102.22 OR APPROVED EQUIVALENT. AGENCY PLAN NUMBER TR57-812S SHEET 3-WALL DESIGN 3. PRIMESOURCE BUILDING PRODUCTS TIN CAPS-MIAMI-DADE NOA CONSTRUCTION TYPE V-B #16-1129.01 OR APPROVED EQUIVALENT. FIRE PROTECTION B SHEET -ROOF DESIGN 4. GAF ROOF UNDERLAYMENT-MIAMI-DADE NOA#18-0119.15 OR FIRE SUPPRESSION SYSTEM NO APPROVED EQUIVALENT. OCCUPANCY UTILITY 5. GAF STARTER STRIP SHINGLE -MIAMI-DADE NOA#15-0922.05 OR NUMBER OF OCCUPANTS 0 APPROVED EQUIVALENT. ALLOWABLE#OF STORIES 0 6. GAF ASPHALTIC SHINGLES- MIAMI DADE NOA#18-0123.06 AND WIND VELOCITY 160 MPH EXPOSURE C NOA#16-0811.11 OR APPROVED EQUIVALENT. FIRE RATING OF EXTERIOR WALLS 0 GENERAL NOTES 7. GAF RIDGE VENT-MIAMI-DADE NOA#18-0619.02 OR APPROVED FLOOR LIVE LOAD 55 PSF EQUIVALENT. FLOOR DEAD LOAD 10 PSF 1.BUILDINGS ARE APPROVED FOR RESIDENTIAL LAWN STORAGE ROOF LIVE LOAD 30 PSF ONLY FLORIDA BUILDING APPROVAL NUMBERS WITH HVHZ- ROOF DEAD LOAD 10 PSF 2.BUILDINGS ARE EXEMPT FROM THE FBC ENERGY "R"RATING OF FLOOR WALL AND ROOF R-0 R-0 R-0 CONSERVATION CODE PER SECTION R101.4.2. 1. TUFF SHED,INC DOORS-FLORIDA BUILDING APPROVAL#FL22202 MODULES PER BUILDING 1 3.BUILDINGS 0 SQ-FT TO 719 SQ-FT ARE EXEMPT OR APPROVED EQUIVALENT. SQUARE FOOTAGE 96 FT2 FROM WINDBORNE DEBRIS IMPACT STANDARDS 2. LP SMARTSIDE SIDING-FLORIDA BUILDING APPROVAL#FL9190APPROVED FOR HURRICANE PROTECTION USAGE NO 4.BUILDINGS 0 SQ-FT TO 399 SQ-FT ARE EXEMPT FROM DOOR OR APPROVED EQUIVALENT. DESIGNED FOR HURRICANE PUBLIC SHELTER IND HEIGHT REQUIREMENTS 3. SIMPSON H2.5A HURRICANE TIE-FLORIDA BUILDING APPROVAL 5.BUILDINGS 400 SQ-FT OR GREATER ARE REQUIRED TO MEET THE #FL10456 OR APPROVED EQUIVALENT. 6'$"DOOR HEIGHT 4. SMART VENT PRODUCTS,INC-FLORIDA BUILDING APPROVAL ENCLOSURE: ENCLOSED 6.ALL WINDOWS AND DOORS TO MEET THE MINIMUM LISTED #FL5822 OR APPROVED EQUIVALENT. RISK CATEGORY: 1 SPECIFICATIONS REQUIRED BY THE FLORIDA BUILDING CODE 5. GULF COAST SUPPLY&MANUFACTURING,LLC-FLORIDA 7.GUTTERS ARE TO BE SITE INSTALLED PER LOCAL AUTHORITY BUILDING APPROVAL#FL11651.23 OR APPROVED EQUIVALENT. IMPORTANCE FACTOR: 1.00 HAVING JURISDICTION AND PERMITTING 8.FOUNDATION PLANS ARE NOT PART OF THESE PLANS ARE ICC ESR REPORT WITH FLORIDA APPROVAL SUPPLEMENT WITH HVHZ- COMPONENT AND CLADDING: ROOF: -31/+19 PSF(ZONE 1) LOCALLY DESIGNED AND APPROVED BY THE AUTHORITY HAVING WIND PRESSURE(PSF)(ASD VALUES) -53/+19 PSF(ZONE 2) 1 JURISDICTION EAGLE METAL TRUSS CONNECTOR PLATES-ICC ESR-1082 FBC (BASED ON 10 SQ FT) -80/+19 PSF(ZONE 3) 9.NO ELECTRICAL PANEL IN BUILDINGS AS SUCH DATA PLATES SUPPLEMENT AND INSIGNIAS WILL BE FASTENED TO THE INTERIOR OF THE WALL: -36/+34 PSF(ZONE 4) DOOR HEADER ON ALL BUILDINGS. 45/+34 PSF(ZONE 5) INTERNAL PRESSURE COEFFICIENT: +/-0.18 MODULES PER BUILDING: 1 Drawn Ely:PK TITLE DRAWING NO. TUFF SHED-FT.LAUDERDALE THESE DRAWINGS AND THE TUFF SHED DESIGN ARE THE PROPERTY TUFF SHED,INC. w n°re nvaeam°bco-a muy°gn°a°na°°w°a `a �}Ge^W!4 TSR7-8125 1919 NW 19TH STREET OF TUFF SHED.INC.THESE ENGINEERING DEPARTMENT Eywmemwav,ve.onn°mw.now Date: 2/8/19 oiaiwsianemre. SHEET INDEX SUITE 301 DRAWINGS ARE FORA Scale:SEE DETAILS FT.LAUDERDALE,FL 33311 BUILDING TO BE SUPPLIED RICHARD J.WILLS,P.E„'^`°°`°v1B9mw:eaun°m°re mo°"m>rea e Storage Buildings&Garages a"�•"aid°a°amu°.a��re°�� - g g g NOA&FL APPROVAL REV.LEVEL 00 AND BUILT BY TUFF SHED. v°nnea°n°iy ei°ar°nm vovin. '$ •"•'° j TUFF SHED,MFG.FACILITIES ANY OTHER USE IS RWIIS.HARRI FSHED.COM DESIGN REQUIREMENTS SHEET FORBIDDEN BY BOTH TUFF 1777 S.HARRISON STREET ANAL EN N" nmuuuoa SHED AND THE ENGINEER OF DENVER,COLORADO 80210 PAGE 1 OF 4 RECORD (303)753-8833 EXT.96315 2019-03-07 TOP LINE ENGINEERING APPROVAL PLAN #TSR7-812S 160 MPH 7 MAR 2019 MAX 12'-0"LONG ^�.0 P LINE ENGIN EERING,_LlC �`' SLINE E GL ENGINEERS William E.Neary,III SMP-51,SMI-79,ICC 5185040 10649 Oakvlew Pointe Terrace Gotha,Florida 34734 TREATED 2X6 FLAT SKID,TYP o P.T 6 (NOTSTRUCTURAL- @ 24" C.MAX FOR SHIPPING 0 4 PURPOSES ONLY) Z. F- I T-0" M8'-0"MAX (2)TREATED 2X6 BLOCKABOVE SKIDS AT EACH EACH 2'-0"BLOCK MUST BE END,TYP INSTALLED WITH(2)ROWS OF 10d NAILS @ 3"O.C. ANGLE BRACKET TO BE 9 SITE INSTALLED WITH TREATED 3/4"T8G FLOOR DECKING ATTACHED ATTACH ALL FLOOR TREATED 2X6 BLOCKS TYPICAL ANCHOR WITH.113"X23/8" JOISTS TO RIM JOISTS WITH 4 CORNERS ATTACHED HOT DIPPED GALVANIZED WITH(3).113'X 3"HOT WITH D ALV113"X I HOT RING SHANK NAILS AT DIPPED GALVANIZED DIPPED GALVANIZED 6"O.C.ON THE EDGE AND RING SHANK NAILS RING SHANK NAILS WALL ASSEMBLY 12"O.C.IN THE FIELD FLOOR ASSEMBLY OWOOD SHED BASE DETAIL OBRACKET DETAIL wry THESE DRAWINGS AND THE ................ TUFF 5 H E D Drawn By: PK TITLE DRAWING NO. TUFF SHED-FT.LAUDERDALE TUFF SHED,INC. ` W, 1919 NW 19TH STREET OF TI IF SHED,INC. HESE TSR7-812S OF TUFF SHED.I .THESE ENGINEERING DEPARTMENT °r Date: 2/8/19 FLOOR FRAMING PLAN SUITE 301 DRAWINGS ARE FORA Scale:SEE DETAILS FT.LAUDERDALE,FL 33311 BUILDING TO BE SUPPLIED RICHARD J.WILLS,P.E, Storage Buildings&Garages REV.LEVEL 00 FLOOR SHEATHING&NAILING AND BUILT BY TUFF SHED. RWILLS@TUFFSHED.COM FORBIDDEN BY BOTH TUFF TUFF SHED MFG.FACILITIES ANY OTHER USE IS 'o„`t1,'s'�:..�•oa`o.\. SHEET � 1777 S.HARRISON STREET '�uunnumao° SHED AND THE ENGINEER OF DENVER,COLORADO 80210 PAGE 2 OF 4 RECORD (303)753-8833 EXT.96315 2019-03-07 TOP LINE ENGINEERING APPROVAL PLAN #TSR7-812S 160 MPH 7 MAR 2019 WALL FRAMING TO BE SPF STUD GRADE OR BETTER AT 16"O.C. DOUBLE TOP PLATE 1. ALTERNATIVE USE PRESSURE TREATED SPF IN FLOOD ZONES CRIPPLES(IF REQ.) DOUBLE TOP PLATE WALL FRAMING NAILING-REFERENCE FBC 6TH EDITION(2017)TABLE 2324.1: CRIPPLES(IF REQ.) HEADER HEADER 1. TOP OR SOLE PLATE TO STUD,END NAIL: (2)16d NAILS ING STUD 2. TOP PLATE TO TOP PLATE:16d NAILS AT 16"OC KING STUD 3. TOP PLATES,WHEN LAPPED AT CORNERS:J2)16d NAILS 4. SOLE PLATE TO FLOOR:16d NAILS AT 16"O2x4 WINDOW SILL TRIMMER SHEAR WALL NAILING NOTES: BASE PLATE P N ENGINEERING,LLC BASE PLATE 1. FOR 3/8"SMARTSIDE OR 7/16"OSB,USE 8d(0.131"0 X 2Y2")COMMON NAILS 1'K cruKAL ENGINEERS FLOOR DECKING 1.1. NAILING:EDGE-@ 3"O.C. FIELD-@ 6"O.C. William E.Neary,III FLOOR DECKING 2. FOR THERMO-PLY BLUE,USE ROOFING NAILS(MIN.0.120"0 X 1Y"WITH A%"HEAD) SMP-51,SMI-79,ICC 5185040 2.1. NAILING:EDGE AND FIELD-@3"oC O WINDOW FRAMING DETAIL O DOOR FRAMING DETAIL 3. NO SINGLE OPENING GREATER THAN 4'-0" 10649 Oakview Pointe Terrace 4. 8'WIDE X 8'-12'LENGTH BUILDINGS ARE BASED ON 3-SIDED DIAPHRAGM.THE SIDE Gotha,Florida 34734 WALL OPPOSITE OF THE WALL WITH OPENINGS MUST BE FULLY SHEATHED WITH NO OPENINGS OTHER THAN GABLE VENT AS SHOWN. DOOR/WINDOW HEADER SCHEDULE 12 WALLS A AND C END WALLS OPENINGS UP TO 4'-0"USE(2)2x4 SPF#2 OPTIONAL WINDOW MUST BE CENTERED 4'WIDE PTIONA TYP WALL SHEATHING OPTIONS: WALLS B AND D(SIDEWALLS) vnrvoow ON THE WALL, MAX 2020 3/B"SMARTSIDE IOPENINGS UP TO 3'-0"USE(2)2x4 SPF#2 PTO3 WID DOOR 3/8"SMARTSIDE WITH FOIL BACKER 7/16'OSB THERMO-PLY RED FLOOD VENTS NOTE: (IFAPPLICABLE) DOOR CENTERED ON WALLS UP TO 10'-0"LONG.12'LONG WALL FLOOD VENT INFORMATION CAN HAVE0 PTIONAL2xz STUDS S'-0'T012'-0' r WINDOWN—TODOOR. (IF APPLICABLE): SHEATHING SMART VENT PRODUCTS INC, FLOOD VENTS III WALL A ELEVATION WALL B ELEVATION FLORIDA BUILDING APPROVAL#FL5822.1-R5. SCALE.3n6•=1•-0" SCALE:3116"=1'-0" PROPOSED SHED III III 12 SIZE(SQ.FT.) 2 VENT MINIMUM III III VENT OPENING BETWEEN REQUIREMENT ADEQUATE WALL STUDS.VENT Q6 MAX 64 FOR UP TO 400 SQ.FT.PER III III SECURED TO SHEATHING 80 MANUFACTURERlSTATE III I AS PER MANUFACTURER'S WINDOW MUST BE CENTERED 96 APPROVAL III I II INSTRUCTIONS OPTIONAL ON THE WALL. OPTIONAL IF IN FLOOD ZONE,USE PRESSURE TREATED WN PT03-WID FRAMING BASE PLATE FLOOD VENTS O VENT DETAIL (IF APPLICABLE) Se",".N.L. .-TO 12'-0' r -1 r WALL C ELEVATION WALL D ELEVATION SCALE:3116'-P-0" SCALE:3/I6=1•-0" Drawn By: PK TITLE DRAWING NO. TUFF SHED-FT.LAUDERDALE THESE DRAWINGS AND THE TUFF SHED,INC. °iPRDI/ TUFF SHED OF IGNTUU SH THE PROPERTY by Rk na,6eea 0,M ate*Md edeea ea �c'iww4ls' TSR7-8125 1919 NW 19TH STREET OF TUFF SHED,INC.THESE ENGINEERING DEPARTMENT 6yl6cM1edW .PE On Ne dao No+n u,Mge Date: 2/8/19 a WALL FRAMING SUITE 301 DRAWINGS ARE FORA °p Sp 0h B' Storage Buildings&Garages Scale:SEE DETAILS BUILDING TO BE SUPPLIED RICHARD J.WILLS,P.E. mteCmem,olNbEecu mt—gt..Ide,ed g g g ELEVATIONS REV.LEVEL 00 FT.LAUDERDALE,FL 33311 TUFF SHED. eipede"d walede"d Me,1p.wreomlee TUFF SHED,MFG.FACILITIES RWILLS�a TUFFSHED.COM vadead on a,y"Iecbo1'ceeioe. AND BUILT BY T ;eek HEADER DETAILS SHEET FORBIDDEN BY BOTH TUFF 1777 S.HARRISON STREET °�l lulnll"G SHED AND THE ENGINEER OF DENVER,COLORADO 80210 VENT DETAILS PAGE 3 OF 4 RECORD (303)753-8833 EXT.96315 2019-03-07 TOP LINE ENGINEERING APPROVAL PLAN #TSR7-8125 160 MPH 7 MAR 2019 3X4 20 GA TRUSS NOTES: TOE NAIL WITH(3) 4'-0" PLATES 16d NAILS,(2)ONE 1 EACH SIDE FBC,6TH EDITION(2017) SIDE,(1)OTHER ANSI/TPI 1-2014 SIDE 12 TRUSSES TO BE SPACED @ 24"OC RAFTER 2 MIN QMATERIAL TO BE 2X4 SPF 6 MAX GRADE#2 OR BETTER PLATES ARE TO BE PRESSED IN THE 8'-0" WOOD PER TPI. j2' REP MEMBER INCREASE:YESr LIN ENGIN EEIN RG,LLC SIMPSON H2.6A a AUUCiUML ENGINEERS HURRICANE TIE AT EACH LUMBER D.O.L.:1.25 END OF TRUSS,INSTALL PER B'SPAN William E.Neary,III MANUFACTURER'S SPECIFICATIONS REACTIONS: WIND: SMP-51,SMI-79,ICC 5185040 WALL TOP PLATES MAX.VERTICAL:320 LBS. ASCE 7-10,160 mph,Exposure C,D.O.L=1.60 10649 Oakview Pointe Terrace MAX.UPLIFT:-327 LBS. Gotha,Florida 34734 SIDING MAX.DEFLECTION: STUDS VERT LL-0.06 IN VERT TL-0.08 IN 2 TRUSS TO WALL CONNECTION DETAIL s�wTs COMMON TRUSS 12'-0"MAX ROOF SHEATHING ROOF SHEATHING 7/16"OSB RUSSES I 7/16"OSB 7/16"OSB WITH FOIL ALL FASTENERS FBC 1517.5 7/16"OSB WITH FOIL ALL FASTENERS FBC 1517.5 2'-0' 4"OC M I -19/32"CDX PLYWOOD -19/32"CDX PLYWOOD CLASS'A'SHINGLES ROOF UNDERLAYMENT METAL ROOF NMOL WITH ERLAY SENT w NAIL WITH TINCAPS a CF1I _ _RIDGE 4 LINE I w HORIZONTAL PANEL a I HORIZONTAL PANEL O FLASHING I DRIP EDGE EDGEWISE BLOCKING EDGEWISE BLOCKING I I I REFco ERENCE NAILING NOTES BELOW ERENCE NAILING NOTES BELOW OF ASSEMBLY ® O F ASSEMBLY _ - - --- DETAIL FOR SHINGLES DETAIL FOR METAL O SGLLE:tLT9. BGLF.N.TS WALL TOP PLATE ROOF SHEATHING NAILING NOTES: ROOF FRAMING PLAN 1.USE 0.113"0 X 2%"HOT DIPPED GALVANIZED RING SHANK NAILS ROOF SLOPE VARIES FROM 2/12 TO 6/12 2.NAILING: FIELD-a 6"D.C. Drawn Ely: PK TITLE DRAWING NO. TUFF SHED-FT.LAUDERDALE THESE DRAWINGS AND THE ya AR1)IV, TUFF 5]{E D DESIGN ARE THE PROPERTY TUFF SHED,AR by a ha has been eb¢wnmwy m9noa end seaoa @�Q E7 e�, 1919 NW 19TH STREET ENGINEERING DEPARTMENT bywm¢bxa¢,PE.Onmeeeb¢ne«n"sense ''% Date: 2/6/19 TSR7$12S OF TUFF SHED.INC.THESE rinds§�e� TRUSS DETAIL SUITE 301 DRAWINGS ARE FORA BUILDING TO BE SUPPLIED RICHARD J.WILLS,P.E. P`nted`piesofmisdo ntommto,mdemI = ( _ Storage Buildings&Garages Scale:SEE DETAILS REV.LEVEL 00 FT.LAUDERDALE,FL 33311 19nw.nd seuledend Me dgne—,st be ROOF FRAMING PLAN AND BUILT BY TUFF SHED. RWILLS@TUFFSHED.COM veddedonany eieevonmooples. :...... TUFF SHED.MFG.FACILITIES ANY OTHER USE IS TRUSS ATTACHMENT SHEET FORBIDDEN BY BOTH TUFF 1777 S.HARRISON STREET SHED AND THE ENGINEER OF DENVER,COLORADO 80210 ROOF ASSEMBLY PAGE 4 OF7--j RECORD (303)753-8833 EXT.96315 2019-03-07 TOP LINE ENGINEERING APPROVAL PLAN #TSR7-812S 160 MPH 7 MAR 2019 EACH 2'-0" BLOCK MUST BE INSTALLED WITH (2) ROWS OF 10d NAILS @ 3" O.C. � J O z ATTACH BRACKET TO STUD Q z STUD THRU HOLE IN ANCHOR PLATE WITH o 0 3/8"0 x 6" CARRIAGE C/) q BOLT AND LOCKNUT N STUD CORNER STUD SIDING TRIM END WALL ANCHOR BRACKET TO BE FLUSH WITH EDGE OF TRIM 0 r `'r) BUILDING SIZE QTY OF ANCHORS UP TO 8X12 4 UP TO 10X15 4 iv ANCHORS INSTALLED AT EACH CORNER OF THE BUILDING AUGER ANCHOR Y OLIVER TECHNOLOGIES • PART NUMBERS: OT3644GPMP- 5/8" X 36" (36" IMBED) GALVANIZED AUGER OT17SWB - SIDEWALL BRACKET FOR USE WITH THRU BOLTS REPORT NO. LO-FJ90129-A -OR- OT24SWBSIDEWALL BRACKET FOR USE WITH THRU BOLTS REPORT NO. LO-FJ90129-B • WORKING LOAD FOR ANCHOR SYSTEM IS 3,150 LBS WITH THE MAXIMUM LOAD OF 5,080 LBS • THE ANCHORS MUST BE INSTALLED AND TESTED IN ACCORDANCE TO THE MANUFACTURER'S SPECIFICATIONS. This Item has ibeenel ctrthedalteshnedandown Basealed Pby Richard RDIW��� Digital Signature. *� No.78835 ti G Printed copies of this document are not considered signed and sealed and the signature must be oq verified on any electronic copies. Tr or °NG��� �` 111111111% ���� 1 APR 2019 Scale: NTS CUSTOMERS NAME: Tuff Shed P.O.#: TUFF SHED Tille:AUGER ANCHOR DETAIL Drawn By:PK Storage Bulidings&Garages FOR WIND SPEEDS Date Drawn:3/13/19 Checked By: UP TO 175 MPH Date Revised: TUFFSHEU 2023 St Lucie Blvd LOT 201 FORT PIERCE FL 34946 Q-376276 �NS �L L',�f YI �rKUS�ef'> �H S� 1 4 F Wail D { F �1 Wall A qWall C t Mast >�rUinl C10 4,0 a be(""-' 1411 Wall B Base Details Options Details Jobsite/Installer Details Building Size&Style High Wind Do you plan to Insulate this building after Tuff Shed TR-700-8'wide by 8'long High Wind-Miami/Dade Installs It? Door Floor and Foundation No 4'x 67"Single Shed Door,Left Hinge 64 Sq Ft 3/4"Treated Floor Decking Is there a power outlet within 100 feet of installation Placement Upgrade location? Paint Selection 64 Sq Ft PT Floor Frame in lieu of Steel Yes Base:Color Not Chosen Yet,Trim: 4 Ea Shed Anchor into Din-Auger or The building location must be level to properly install the Delicate White MR88 building.How level is the Install location? Roof Selection Vents Within 4"of level Birchwood Dimensional Premium 2 Ea 16"x8"Wall Vent-White Will there be 18"of unobstructed workspace around the Shingle perimeter of all four walls? ;Drip Edge Yes White Can the Installers park their pickup truck&trailer within approximately 200'of your Installation site? Yes Substrate Shed will be Installed on? Grass Manufactured Modular Delivery Method Trailer Delivery Customer Signature: Date: