HomeMy WebLinkAboutProduct Approval (2) 2/1/2020 Florida Building Code Online
• ProfessionalRegulation
rZ
BCIS Hpme I Login I User Registration I Hot T pies I Submit Surcharge I Stats&Facts I Publications I Contact Us I SCIS Site Map I Links I Search I
Florida
Product Approval
t,, q USER:Public User ---" -
.� REEIVD
Product Approval Menu>Product or Application Search>APpt`kation UsL>ApD1' on Detail
• FL# FL15216-R5
FEB 0 4 2020
Application Type Revision ST. Lucie County, Permitting
Code Version 2017
Application Status Approved
Comments -
AW
Archived r' FILL. LAU,
Product Manufacturer Owens Coming Roofing-and Asphalt, LLC
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43645
(740)321-6345
Greg.Keeler@owenscoming.com
Authorized Signature Keeler Greg
Greg.Keeler@owenscoming.com
Technical Representative Greg Keeler
Address/Phone/Email 2790 Columbus Road
Granville,OH 43023
(740)321-6345
greg.keeler@owenscoming.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
LJ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity Intertek Testing Services NA,Inc.-QA Entity
Quality Assurance Contract Expiration Date 12/31/2020
Validated By John W.Knezevich,PE
!f Validation Checklist-Hardcopy Received
Certificate of Independence FL15216 R5 COI 2019 01 COI NIEMINEN.Ddf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970(tear) 2015
ASTM D226(physicals) 2009
TAS 117(B) 1995
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.floridabuilding.0rg/pr/pr app dfl.aspx?param=wGEVXQwtDgv3yVVKJZ1QRAdhyl2u8kQGTzrShrNGklil7tbzoVhOww%3d%3d 1/2
2/1/2020 Florida Building Code Online
v
Product Approval Method Method 1 Option D
Date Submitted 04/19/2019
Date Validated 04/22/2019
Date Pending FBC Approval 04/25/2019
Date Approved 06/18/2019
Date Revised 12/16/2019
Summary of Products
FL# Mo , umber or Name Description
15216.1 RhinoRoof U20 and ABC Pro Guard Synthetic roof underlayments
20 Roof Underlayments
Limits of Use Installation Instructions
Approved for use i HVHZ:Yes F 1 216 R5 H 2019 4 FINAJ ER OWEN
Approved for use o tside HVHZ:Yes CORNIN RHIN R F FL1521 -R p)f
Impact Resistant:N Verified By: Robert Nieminen E-59166
Design Pressure: N/A Created by Independent ' d Party:Yes
Other:See ER Section 5 r Limits of Use. Evaluation Reports
FL1521 R5 AE 20 04 FINAL ER OWENS
RNING RHIN OF FL15216-R5.pdf
Created b ependent Third Party:Yes
Back Next
Contact Us:;2601 Blair Stone Rodd.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Cogvright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emals
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
wa- ® OCIZ
Credit.Card
Safe,
https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgv3yVVKJZ1QRAdhyl2u8kQGTzrShrNGkl il7tbzoVhOww%3d%3d 212
r -
r
MEMO l etc.
Certificate ofAuthorization X32455
353 Christian Street, Unit#13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
REPORTEVALUATION
Owens Corning Roofing and Asphalt,LLC Evaluation Report 140510.02.12-R5
One Owens Corning Parkway FL15216-R5
Toledo,OH 43659 Date of Issuance:02/17/2012
(740)321-6345 Revision 5:04/18/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert-Nieminen,
P.E.for use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products
described herein have been evaluated for compliance with the 6t'Edition(2017)Florida Building Code sections noted
herein.
DESCRIPTION:.RhinoRoof U20 and ABC Pro Guard 20 Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE:'This Evaluation Report is valid until such time as the named-products)changes,the referenced
Quality Assurance documentation_changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.ofany changes to the
product(s),the Quality Assurance or the production facility location(s). NEMO J etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors-and shall be available for inspection at the job-site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 4.
Prepared by:
Robert J.M.Nieminen P.E.- - -
; o
Ec� The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCA ANE1983 �'!�i; ;; ; •�`"~ Nieminen,P.E.on 04/18/2019.This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not awned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a finpncial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any-other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO Ietc.nor Robert Nieminen,P.E.are,in anyway,the Designer of Record for any project
on which this Evaluation Report,or previous versions thereof,is/was used for permitting-or design,guidance unless retained-specifically
for that purpose.
r '
✓r
O. NEMOJetc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub-Category: U nderlayment
Compliance Statement: RhinoRoof U20 and ABC Pro Guard 20 Roof Underlayments, as produced by Owens
Corning Roofing and Asphalt, LLC, have demonstrated compliance with the following sections of the 6u' Edition
(2017) Florida Building Code through testing in accordance with applicable sections of the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section 'Properties Standard "Year
1507.1.1,R905.1.1 Exception, Unrolling,Breaking Strength,Pliability ASTM D226 2009
1518.4
1507.1.1,R905.1.1 Exception Tear Strength ASTM D1970 2015
TAS 110 Pull-through resistance TAS 117(8) 1995
3. REFERENCES:
Entity' Examination Reference : Date
ITS(TST1509) Physical Properties 100539395COQ-006 10/27/2011
ITS(TST1509) Physical Properties 100539395COQ 002 10/27/2011
ITS(TST1509) Physical Properties 100539395COQ-006 03/14/2014
PRI(TST5878) ASTM D1970;Tear strength OCF-330-02-02 10/03/2017
PRI(TST5878) TAS 117(8);Pull-through OCF-422-02-01 04/03/2018
ITS(QUA1673) Quality Control Service Confirmation 09/30/2017
4. PRODUCT
u' Spe,cification Plan (s) Description
4.1 RhinoRoof U20 FBC 1507.1.1& Qingdao, Multilayered polymer woven coated
R905.1.1(Exception) China synthetic roof underlayment
4.2 ward 20 FBC 1507.1.1& Qingdao, Multilayered polymer woven coated
R905.1.1(Exception) China synthetic roof underlayment
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen, P.E.are,in anyway,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 Fire Classification is not part of this Evaluation Report;referto current Approved Roofing Materials Directory for fire
ratings of this product.
5.3 RhinoRoof U20 and ABC Pro Guard 20 Roof Underlayments may be used with any prepared roofcover where the
product is specifically referenced within FBC approval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for approval based,on this evaluation combined with supporting data for the prepared
roof covering.
5.4 Allowable Roof Covers:
TABLE 1:'ROOF COVER OPTIONS
nderlayment AEPhalt. Wood Shakes Slate or
Shingles. Tile 'Metal Shingles Simulated slate
—� RhinoRoof U20 Yes No Yes Yes No
BC Pro Guard 20 Yes No Yes Yes No
NEMO ETC,LLC Evaluation Report 140510.02.12-RS
Certificate of Authorization#32455 a EDITION(2017)FBC NON-HVHZ AND HVHZ EVALUATION FL15216-RS
RhinoRoof U20 and ABC Pro Guard 20 Roof Underlayments Revision 5:-U4/18/2019
Page 2 of 4
ONEMOletc.
5.5 Exposure Limitations:
RhinoRoof U20 and ABC Pro Guard 20 shall not be left exposed for longer than 30-days after installation.
6. INSTALLATION:
6.1 RhinoRoof U20 and ABC Pro Guard 20 Roof Underlayments shall be installed in accordance with the manufacturer's
published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted
below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application.
63, RhinoRoof U20 and--ABC Pro Guard 20: .
6.3.1 NON-HVHZ Jurisdictions:
6.3.1.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table
1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed,considering the wider sheet-width for
double-layer applications.
6.3.1.2 Fasteners:
For exposure up to maximum 24 hours,corrosion resistant fasteners-may be 1-inch roofing nails with a 3/8-inch
diameter head,minimum 1-inch diameter plastic or metal cap nails or FBC-HVHZ nails-&1-5/8"diameter tin caps
(with the rough edge facing up). The use of staples is prohibited.
For exposure beyond 24 hours up to maximum 30 days, corrosion resistant fasteners shall be minimum 1-inch
diameter plastic or metal cap nails or FBC HVHZ pails&1-5/8"diameter tin caps(with the rough edge facing up).
The use of staples is prohibited.
Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: ':..except metal cap nails shall
be required where the ultimate design wind speed, V„lz equals or exceeds 150 mph."
Owens Corning Roofing and Asphalt,LLC has furnished data to permit the use of 1-inch diameter plastic cap nails
in lieu of metal cap nails for these applications,when the RhinoRoof U20 or ABC Pro Guard 20 underlayment is
installed beneath mechanically fastened prepared roof covers referenced in FBC Table 1507.1.1 or R905.1.1.
6.3.1.3 Slopes of 4:12 or ereater:
End(vertical)laps shall be minimum 6-inches and side(horizontal)laps shall be minimum 4-inches. End(vertical)
laps shall be offset from course to course not less than 6 feet.
'Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 4-inch O.C.
When batten systems are to be installed atop the underlayment, the underlayment_need only be preliminarily
attached pending attachment of the battens.
6.3.1.4 Slopes of 2:12 to less than 4:12:
End(vertical)laps shall be minimum 12-inches and side(horizontal)laps shall be minimum 22-inches. End(vertical)
daps shall be offset from course to course not less than 6 feet.
Begin by fastenirig.a 22-inch wide strip along the eaves. Place a full-width sheet over the starter, completely
overlapping the starter course. Continue upslope,maintaining minimum 22-inch side(horizontal)laps,resulting in
a double-layer application.
Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 4-inch D.C.
When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily
attached pending attachment of.the battens.
NEMO ETC,LLC Evaluation Report 140510.02.12-115
Certificate of Authorization#32455 0 EDITION(2017)FBC NON-HVHZ AND HVHZ EVALUATION FL15216-RS
RhinoRoof U20 and ABC Pro Guard 20 Roof Underlayments Revision 5:04/18/2019
Page 3 of 4
NNEMOjetc.
6.3.2 HVHZJurisdictions:
6.3.2.1 Shall be installed in a shingle fashion with minimum 4-inch wide side(horizontal) laps and minimum 6-inch wide.
end laps.
6.3.2.2 Shall be fastened with FBC HVHZ approved-corrosion resistant, 1-5/8"diameter tin-caps and 12 gauge 1.25"long
annular ring-shank nails(FBC 1517.5)spaced max.6-inch o.c.at all laps and 12-inch o.c.at three(3)equally spaced
rows in the field of the sheet.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for plants covered under Rule 61G20-3 QA requirements. Refer
to Section 4 herein for product&production locations having met codified physical properties specifications.
9. QUALITY ASSURANCE ENTITY.
Intertek Testing Services NA Inc.-ETL/Warnock Hersey-QUA1673;(604)520-3321;
peter.gildenstern@intertek.com
-END OF EVAWATtON REPORT-
NEiVIO ETC,LLC Evaluation.Report 140510.02.12-RS
Certificate of Authorization#31455 6'"EDITION(2017)FBC NON-HVHZ AND HVHZ EVALUATION FL15216-RS
RhinoRoof U20 and ABC Pro Guard 20 Roof Underlayments Revision 5:04/18/2019
Page 4 of 4