Loading...
HomeMy WebLinkAboutProduct Approval 1/30/2020 Florida Building Code Online s BCIS Home I Log In I User Registration Hot Topics I Submit Surcharge I Stats&Facts I Publications I Contact Us I BCIS Site Map Links I Search 1 Florida '€ Product Approval r USER:Public User Eta,ysorai at�a'm . Product ARoroval Menu>Product or Application Search>Application List>Application Detail ty, FL# FL16107-R10 Application Type Revision Code Version 201.7 Application Status Approved Comments Archived Product Manufacturer Clopay Building Products Company Address/Phone/Email 8585 Duke Blvd. Mason,OH 45040 (513)770-6062 mwestertleld@clopay.com Authorized Signature Scott Hamilton shamilton@clopay.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email I Category Exterior Doors Subcategory Sectional Exterior Door Assemblies Compliance Method Evaluation.Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 3 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Scott Hamilton Evaluation Report Florida License PE-63286 Quality Assurance Entity Intertek Testing Services NA,Inc. -.QA Entity Quality Assurance Contract Expiration Date 12/31/2020 Validated By Gary Pfuehler Validation Checklist-Hardcopy Received Certificate of Independence FL16107 R10 COI Certification of Independence of Validation Entity_ (wry Pfuehler.W FL16107 R10 COI Statement on Indepe_n_dence of Evaluation Entity_ ScottHamilton 120424.pdf Referenced Standard and Year(of Standard) Standard Year ANSI/DASMA 108 2005 ANSI/DASMA 115 2005 ASTM E1886 2005 ASTM E1996 2009 ASTM E330 2002 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards https://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgvyf4ngAXhlO9aYpgetu2p/o2f5n8XnBD2%2fVo8JculDXOIVp/D2fA%3d%3d 1/5 1/30/2020 Florida Building Code Online Certified By Florida Licensed Professional Engineer or Architect FL16107 R10 Equiv 20170809-FBC-DASMA 108 equiv.odf FL16107 R10 Equiv 20170809-FBC-DASMA 115 equiy,pd� Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/10/2017 Date Validated' 08/14/2017 Date Pending FBC Approval 08/16/2017 Date Approved 10/10/2017 Summary of Products Go to Page Page 2/3 0 0 FL# Model,Number or Name Description 16107.21 21 W8-16 DSIE-1F471: GD2SP, Double-skin Insulated EPS(exterior skin 27 ga. min.; interior GR2SP,GD2LP,GR2LP,AR2SP, skin 27 ga. min.) Double-Car(97'to 167'wide)WINDCODE@ AR2LP,ED2SP,ED2LP,4302,HDGC, W8 Garage Door with Optional Impact-Resistant Lites 6202, MFC68,4305,HDGR,6205, SFR68,MFR68 Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16107 R10 II 104786-RevO4-signed•pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure: +46 PSF/-52 PSF Evaluation Reports Other: Max.Wind Speed(V_ult): 170 MPH.Solid doors or FL16107 R10 AE CBPC 130214-A.g_df doors'with optional impact-resistant glazing are Impact- Created by Independent Third Party: No resistant(large missile impact). 16107.22 22 W6-09 DSIE-1F171: 4400,4401, Double-skin Insulated EPS(exterior skin 27 ga. min.; interior 4301,4300,4301,4310, HDG, skin 27 ga. min.)Single-Car(up to 9'0"wide)WINDCODE@ W6 HDGL, HDGF,66, 66G,67,67G,68, Garage Door with Optional Impact-Resistant Lites SP200,SF200,SE200,6200,6201, 6203 Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16107 R10 II 101526-A-Rev20 signed.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other: Max.Wind Speed (V_ult): 170 MPH.Solid doors or FL16107 R10 AE CBPC 130214-A.Rdf doors with optional Impact-resistant glazing are impact- Created by Independent Third Party: No resistant(large missile impact). 16107.23 23 W6-09 DSIE-1F171:4400,4401, Double-skin Insulated EPS(exterior skin 27 ga.min.; interior 4300,4301,4310,HDG,HDGL, skin 27 ga. min.)Single-Car(up to 9'0"wide)WINDCODE8 W6 HDGF,66, 66G, 67,67G,68,SP200, Garage Door SF200,SE200,6200,6201,6203 Limits of Use Installation Instructions Approved for use in HVHZ: No FL16107 R10 II 101526-B-Rev20 signed•pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other: Doors with standard glazing meet the wind load FL16107 R10 AE CBPC 130214-A.pdf requirements of the building code but DO NOT meet the impact Created by Independent Third Party: No resistant requirement for windborne debris regions. 16107.24 24 W6-09 PAN-2F153: 84A,94,73, Steel Pan(min. 25 ga.)Single-Car(up to 9'0"wide) 75, 1500, 190,4RST,4RSF,4F, WINDCODEO W6 Garage Door with Optional Impact-Resistant 6RST,6RSF,48,42,55,48B,42B, Lites 55S,GD5S,GD5SV,GR5S,GR5SV, AR5S,AR5SV,ED5S, ED5SV Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16107 R10 II 101348-A-Revl7-signed.odf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other: Max.Wind Speed(V_ult): 170 MPH.Solid doors or FL16107 R10 AE CBPC 130214-A.pdf Created by Independent Third Party: No https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvyf4ngAXhl09aYpgetu2%2f5n8XnBD2%2fvo8JculDX01V%2fA%3d%3d 2/5 1/30/2020 Florida Building Code Online doors with optional Impact-resistant glazing are Impact- resistant(large missile impact). 16107.25 25 W6-09 PAN-217153: 84A,94,73, Steel Pan(min.25 ga.)Single-Car(up to 9'0"wide) 75, 1500, 190,4RST,4RSF,4F, WINDCODE@ W6 Garage Door 6RST,6RSF,48,42,55,48B,42B, 55S,GD5S,GD5SV,GR5S,GRSSV, AR5S,AR5SV, ED5S, ED5SV Limits of Use Installation Instructions Approved for use in HVHZ: No FL16107 RIO II 101348-B-Revl7-signed d Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other: Doors with standard glazing meet the wind load FL16107 RIO AE CBPC 130214-A.pdf requirements of the building code but DO NOT meet the impact Created by Independent Third Party: No resistant requirement for windborne debris regions. 16107.26 26 W6-09 PAN-2F156: 76,76V,2RST Steel Pan(min. 25 ga.)Single-Car(up to 9'0"wide) WINDCODEO W6 Garage Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16107 RIO II 101348-A-Revl7-signed.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other:Max.Wind Speed (V ult): 170 MPH.Solid doors or FL16107 R10 AE CBPC 130214-A.pdf doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No resistant(large missile impact). 16107.27 27 W6-09 PAN-2F156: 76,76V,2RST Steel Pan(min. 25 ga.)Single-Car(up to 9'0"wide) WINDCODEO W6 Garage Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL16107 R10 II 101348-B-Revl7-signed.odf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other: Doors with standard glazing meet the wind load FL16107 RIO AE CBPC 130214-A.Rdf requirements of the building code but DO NOT meet the Impact Created by Independent Third Party: No resistant requirement for windborne debris regions. 16107.28 28 W6-09 DSIE-1A171: 2050,2051, Double-skin Insulated EPS(exterior skin 27 ga. min.; interior 2053,4050,4051,4053,62, 64,65, skin 29 ga. min.)Single-Car(up to 9'0"wide)WINDCODE@ W6 62G,62LG,64G,SDP38,SFL38, Garage Door SRP38, 134, 135, 136,6130,6131, 6133 Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16107 R10 II 104814-A-RevOO-signed.ndf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure: +36 PSF/-44 PSF Evaluation Reports Other: Max.Wind Speed(V_ult): 170 MPH. Solid doors are FL16107 RIO AE CBPC 130423-A.pd impact-resistant(large missile impact). Created by Independent Third Party: No 16107.29 29 W6-09 DSIE-1A171: 2050,2051, Double-skin Insulated EPS(exterior skin 27 ga. min.; interior 2053,4050,4051,4053,62,64,65, skin 29 ga. min.)Single-Car(up to 9'0"wide)WINDCODE@ W6 62G,62LG,64G,SDP38,SFL38, Garage Door SRP38, 134, 135, 136,6130,6131, 6133 Limits of Use Installation Instructions Approved for use in HVHZ: No FL16107 R10 II 104814-B-Rev00-sig en d,pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +36 PSF/-44 PSF Evaluation Reports Other:Doors with standard glazing meet the wind load FL16107 RIO AE CBPC 130423-A.pdf requirements of the building code but DO NOT meet the impact Created by Independent Third Party: No resistant requirement for windborne debris regions. 16107.30 30 W6-09 DSIE-1F471: GD2SP, Double-skin Insulated EPS(exterior skin 27 ga,min.; interior GR2SP,GD2LP,GR2LP,AR2SP, skin 27 ga. min.)Single-Car(up to 9'0"wide)WINDCODE@ W6 AR2LP,ED2SP,ED2LP,4302,HDGC, Garage Door with Optional Impact-Resistant Lites 6202,MFC68,4305,HDGR,6205, SFR68, MFR68 Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16107 R10 II 103954-A-Rev05-signed.odf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other: Max.Wind Speed (V_ult): 170 MPH.Solid doors or FL16107 RIO AE CBPC 130423-A.pdf Created by Independent Third Party: No hftps://www.floridabuilding.org/pr/pr app_Otl.aspx?param=wGEVXQwtDgvyf4ngAXhlOgaYpgetu2%2f5n8XnBD2°/a2fVo8JculDX01V%2fA%3d%3d 3/5 1/30/�020 Florida Building Code Online doors with optional impact-resistant glazing are impact- resistant(large missile impact). 16107.31 31 W6-09 DSIE-1F471: GD2SP, Double-skin Insulated EPS(exterior skin 27 ga. min.; interior GR2SP,GD2LP,GR2LP,AR2SP, skin 27 ga. min.)Single-Car(up to 9'0"wide)WINDCODE@ W6 AR2LP, ED2SP, ED2LP,4302, HDGC, Garage Door 6202,MFC68,4305,HDGR,6205, SFR68, MFR68 Limits of Use Installation Instructions Approved for use in HVHZ: No FL16107 RIO II 103954-B-RevOS-signed.odf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other: Doors with standard glazing meet the wind load FL16107 R10 AE CBPC 130423-A.Rdf requirements of the building code but DO NOT meet the impact Created by Independent Third Party: No resistant requirement for windborne debris regions. 16107.32 32 W6-09 PAN-2F443: G4S,GS4, Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.)Single-Car GD4S,GR4S,G4SV,GS4V,GD4SV, (up to 9'0"wide)WINDCODE@ W6 Garage Door with Optional GR4SV,E4S,ED4S, E4SV, ED4SV, Impact-Resistant Lites SS4,AR4S,SS4V,AR4SV Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16107 R10 II 103488-A-RevO7-signed.odf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other: Max.Wind Speed(V_ult): 170 MPH. Solid doors or FL16107 R10 AE CBPC 130423-A.pdf doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No resistant(large missile impact). 16107.33 33 W6-09 PAN-2F443: G4S,GS4, Double-skin Insulated EPS(exterior skin 27 ga.min.; interior GD4S,GR4S,G4SV,GS4V,GD4SV, skin 27 ga. min.)Single-Car(up to 9'0"wide)WINDCODE@ W6 GR4SV,E4S, ED4S,E4SV, ED4SV, Garage Door SS4,AR4S,SS4V,AR4SV Limits of Use Installation Instructions Approved for use in HVHZ: No FL16107 R10 II 103488-B-RevO7-signed.odf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other: Doors with standard glazing meet the wind load FL16107 R10 AE CBPC 130423-A.{1df requirements of the building code but DO NOT meet the impact Created by Independent Third Party: No resistant requirement for windborne debris regions. 16107.34 34 W6-09 PAN-2F446: G4L,GL4, Gallery/Artistry/Expressions: Steel Pan(min. 24 ga.)Single-Car GD4L,GR4L,G4LV,GL4V,GD4LV, (up to 9'0"wide)WINDCODE@ W6 Garage Door with Optional GR4LV,E4L,ED4L, E4LV, ED4LV, Impact-Resistant Lites SL4,AR4L,SL4V,AR4LV Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16107 R10 II 303488-A-Rev07-5igned.odf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other: Max.Wind Speed (V_ult): 170 MPH.Solid doors or FL16107 R10 AE CBPC 130423-A.pdf doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No resistant(large missile impact). 16107.35 35 W6-09 PAN-2F446: G4L,GL4, Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.)Single-Car GD4L,GR4L,G4LV,GL4V,GD4LV, (up to 9'0"wide)WINDCODE@ W6 Garage Door GR4LV,E4L, ED4L,E4LV, ED4LV, SL4,AR4L,SL4V,AR4LV Limits of Use Installation Instructions Approved for use in HVHZ: No FL16107 RIO II 103488-B-Rev07-_s gned.odf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other: Doors with standard glazing meet the wind load FL16107 RIO AE CBPC 130423-A.pdf requirements of the building code but DO NOT meet the impact Created by Independent Third Party: No resistant requirement for windborne debris regions. 16107.36 36 W6-16 PAN-2F443: GD4S,GR4S, Gallery/Artistry/Expressions: Steel Pan(min.24 ga.)Double- ED4S,AR4S Car(9'2"to 16'2"wide)WINDCODE®W6 Garage Door with Optional Impact-Resistant Utes Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL16107 R10 II 104790-A-RevO7 signed.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure: +38 PSF/-42 PSF Evaluation Reports Other: Max.Wind Speed(V_ult): 170 MPH.Solid doors or https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvyf4ngAXhl09aYpgetu2%2f5n8XnBD2%2fVo8JculDX01V%2fA%3d%3d 4/5 1/30/2020 Florida Building Code Online doors with optional impact-resistant glazing are impact- FL16107 R10 AE CBPC 130423-A.Rdf resistant(large missile impact). Created by Independent Third Party: No 16107.37 37 W6-16 PAN-2F443: GD4S,GR4S, Gallery/Artistry/Expressions: Steel Pan(min.24 ga.)Double- ED4S,AR4S Car(9'2"to 16'2"wide)WINDCODE@ W6 Garage Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL16107 R10 II 104790-B-ReV07 signed.0ff Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +38 PSF/-42 PSF Evaluation Reports Other: Doors with standard glazing meet the wind load FL16107 R10 AE CBPC 130423-A.pdf requirements of the building code but DO NOT meet the impact Created by Independent Third Party: No resistant requirement for windborne debris regions. 16107.38 38 W6-16 PAN-2F446: GD4L,GR4L, Gallery/Artistry/Expressions: Steel Pan(min. 24 ga.) Double- ED4L,AR4L Car(9'2"to 16'2"wide)WINDCODE@ W6 Garage Door with Optional Impact-Resistant Lites Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16107 R10 II 104790-A-Rev07 signed.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure: +38 PSF/-42 PSF Evaluation Reports Other: Max.Wind Speed (V_ult): 170 MPH.Solid doors or FL16107 R10 AE CBPC 130423-A.pdf doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No resistant(large missile impact). 16107.39 39 W6-16 PAN-2F446: GD4L,GR41_, Gallery/Artistry/Expressions: Steel Pan(min.24 ga.)Double- ED4L,AR4L Car(9'2"to 16'2"wide)WINDCODE@ W6 Garage Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL16107 R10 II 104790-B-Rev07 signed.Ddf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +38 PSF/-42 PSF Evaluation Reports Other: Doors with standard glazing meet the wind load FL16107 R10 AE CBPC 130423-A.pdf requirements of the building code but DO NOT meet the impact Created by Independent Third Party: No resistant requirement for windborne debris regions. 16107.40 40 W8-09 DSIE-1F471: GD2SP, Double-skin Insulated EPS(exterior skin 27 ga. min.; interior GR2SP,GD21_P,GR2LP,AR2SP, skin 27 ga. min.)Single-Car(up to 9'0"wide)WINDCODE@ W8 AR2LP,ED2SP,ED21_P,4302,HDGC, Garage Door with Optional Impact-Resistant Lites 6202, MFC68,4305,HDGR,6205, SFR68, MFR68 Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16107 R10 II 104119-RevO4-signed.pdf Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure: +54 PSF/-60 PSF Evaluation Reports Other: Max.Wind Speed(V ult): 170 MPH.Solid doors or FL16107 R10 AE CBPC 130423-A.pdf doors with optional Impact-resistant glazing are impact- Created by Independent Third Party: No resistant(large missile impact). Go to Page Page 2/3 Back Pfext Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emaiis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: 99 Credit Card j Safe j hftps://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvyf4ngAXhl09aYpgetu2%2f5n8XnBD2%2fVo8JculDXOIV%2fA%3d%3d 5/5 i f 4 3 2 1 I 'CLASSIC'RAISED PANEL EMBOSS DOORS 'CARRIAGE HOUSE'RAISED PANEL EMBOSS DOORS SHEET, REVISIONS MODELS 24 GA 25 GA 25 GA MODELS 25 GA 25 GA 1 OF CL I AY 84A,94 73, 75 76 CLOPAY REv. N0. ZONE: DATE: ECN N0. APPVD: DESCRIPTION IDEAL 4RST,4F■ 6RST 2RST 'GALLERY' 15I15S;GRSS -- 17 - 2/I 1/13 - SH RENSEO FOR NEW LOADS. HOLMES 48.48B 142,42B -- HOLMES AR5S -- Y -- SHORT PANEL 'AR71STRY' LONG PANEL IDEAL MODEL 4F IS FLUSH •CARRIAGE HOUSE' EOSS D SHORT PANEL -LONG.PANEL SHORT PAN /FI SH MODFI S: (1) INTERMEDIATE STILE 13MVEEN EACH D EMBOSS [(3) STILES PER SECTION AT 9'0"WIDE].. EACH'INTERM. STILE OPTIONAL GLAZING MAY BE ATTACHED WITH TOG-L-LOC (TOP & BOTTOM) AND.URETHANE ADHESIVE I STANDARD OR IMPACT RESISTANT (ALONG CENTER). GLAZING. SEE SECTION B-B ON LONG.PANEL MODELS: (3) TOTAL STILES PER SECTION. (1)STANDARD SHEET 2 FOR DETAILS: INTERMEDIATE STILE BETWEEN EACH EMBOSS. EACH STANDARD INTERM. MAX, STANDARD SIZE IS STILE ATTACHED WITH TOG-L-LOC (TOP & BOTTOM) AND URETHANE 19-1/2-06". IMPACT RESISTANT ADHESINE (ALONG CENTER). EXTRA INTERM. STILES (1) PER LONG PANEL DOOR HEIGHT H OF H OF U-BARS GLAZING IS 21-5/8%14-1/8". PER SECTION,.FIELD-INSTALLED WITH (4) #8 SMS (PER STILE). SECTIONS MAX DLO SIZE IS 18-1/2"xl1 UP TO 7.0' 4 6 .. A END STILES ATTACHED TO DOOR 7'3' TO 8'9' .5 8 SKIN WITH PATENTED TOG-L-LOC 9'0' T❑.!0'6' '6 9 .SYSTEM (TOP, BOTTOM, & CENTER), 10'9' TO 12'3' 7 !1 0: t< F f6, S/ 'F SEE END HINGE 12'6' TO 14'0' 8 12 m VIEW B. C 14'3' TD 15-9' 9 14 16'G. 1D .15 - o - MAX SECTION HEIGHT: 21' o oZ , SEE INTERMED. HINGE C O VIEW C. SLIDE BOLT LOCK u N _ END ENGAGES INTO STILE. VERTICAL TRACK. ONE LOCK ON EACH SIDE OF o DOOR. THIS ODOR MEETS OR-EXCEEDS THE DESIGN LOADS FOR THE =N- i� ULTIMATE riRHO SPEEDS LISTED BELOW ACCORDING TO THE FLORIDA �_ BUILDING CODE OR THE INTERNATIONAL BUILDING CODE (BASED ON O o TWO POINT LOCKING ASCE7-10)FOR THE FOLLOWING CONDITIONS: 1)ENCLOSED ow INSIDE SLIDE BOLT BUILDING;2) DOOR HAS 2'OF WIDTH IN BUILDING'S END ZONE,3) ox _ INTO TRACK SNAP LATCH,ENGAGES LOCK OPTION. ANY ROOF SLOPE,AND 4)TESTING IN ACCORDANCE WITH �. ONTO VERTICAL TRACK. END ANSI/DASMA 108.SITE-SPECIFIC CALCULATIONS BY A OUALIFIEO �" ONE SNAP LATCH ON STILE. DESIGN PROFESSIONAL MAY DIFFER. --- -- EACH SIDE Of DOOR. B ULTIMATE WIND. T55 !60 ]7p 180 195 B ml SPEED(MPH) OUTSIDE EXPOSURE B,C,D R.C. D H.C�CB A OUTSIDE HANDLE. LOCK BAR. CATEGORY OPTIONAL OUTSIDE KEYED LOCATION OF END ENGAGES IN LOCK POSITION OPTIONAL VENT I KEYED STILE. TRACK ON MEAN.RQDF HEIGHT 25' IS' 25' MAX. DOOR WIDTH 9'-0" HANDLE' EACH SIDE INSIDE FLFVATION INSIDE HANDLE OF DOOR. 'CLASSIC' SHORT RAISED-PANEL SHOWN. LONG 'CLASSIC' OUTSIDE KEYED LOCK WITH OUTSIDE KEYED LOCK WITH AND SHORT 'CARRIAGE HOUSE' ARE ALSO APPROVED. SNAP LATCH LOCK OPTION. LOCK BAR LOCKING. ,,.. Ha. *•�' No' 63 �•4.* METAL/8" SHEET MANUFACTURING PRODUCT CODE 3 _I�l//' METAL SCREWS SHORT PANEL.,'PAN-2F153 � .O ¢ l'S .,�� O DESIGN LOADS: +38:0 P.S.F. & -44.0 P.S.F. LONG PANEL: PAN-2P156 y TEST LOADS: +57.0'P.S F. & -66.0 P.S.F. 77 PART NO.: N/A T 4 A ; ST E OF ,U 1/4"x3/4" SELF un esa Stoted Otne n -Clopay 8585 Doke 800levord WINDLOAD RATING �0�., Qi: TAPPING SCREWS Moson.OH 45040 VSA F' O R'1'Q N�.� o0 o TOLERANCES-7 Tel.No.513-770-1800 �,I! 1TI P ^( ' ��,♦ .O 2.031 8v34ny:Prodtxts Cmipn�y F"No.513-170-4853 Vy � 1J I �V I"ritNA it%,% .00= 1.015 DESCRIPTION: CLASSIC AND CH RP STEEL PAN SC +38/-44 PSF 14 CA. END HINGES 18 GA. INTERMEDATE HINGE .000 t.005 DRAWN BY: 'MW DATE: 3/15/95 SCALE: NTS A000 = t.001 DwG.D DESIGN ENGINEER VIEW "B VIEW-" D`e9iies`=-t1%a' CHECKED BY: -- DATE: -- SHEET-IOF a SIZE SCOTT HAMILTON. P.E. Umless Stnte4 Ok.—+ e FLORIDA LICENSE No..63286 DIMENSIONS ARE IN INCHES.DWG. NO.: 101348 - A/8 VER: BC 4 3 2FLOR90A PH ODMC T lappIRDWQL 16107 I 4 3 2 'CLASSIC'RAISED PANEL EMBOSS DOORS 'CARRIAGE HOUSE'RAISED PANEL EMBOSS DOORS SMEET! REVISIONS MODELS 24 GA 25 GA 25 GA MODELS 25 GA 25 GA 2 OF 4 REV_ NO. ZONE: DATE: ECN NO. APPVD: DESCRIPTION CLOPAY 84 a,94 73, 75 �222RST 76 CLOPAY IDEAL 4RST, qFr 6RS7 GALLERY. GD5S,GRSS -- 17 - - - - SEE REVISION HISTORY ON.SHEET ONE. HOLMES 48,488 42.42B -- HOLMES ARSS -- 'ARTISTRY' SHORT PANEL LONG PANEL IDEAL -MODEL 4F IS FLUSH 'CARRIAGE HOUSE' ED5S D SHORT.PAHEL LONG.PANEL D t I IMPACT—RESISTANT CONSTRUCTION: STANDARD ASSEMBLY CONSTRUCTION: SOLID DOORS(NO GLAZING) OR DOORS WITH OPTIONAL IMPACT-RESISTANT GLAZING ARE OPTIONAL DSB OR 1/8"ACYRLIC LITES AVAILABLE. OPTIONAL ACRYLIC GLAZING IS ,IMPACT-RESISTANT. OPTIONAL INJECTION-MOLDED POLYCARBONATE FRONT FRAME AND PLASKOLITE OPTIX OR LUCITE•CP APPROVED CC2 PLASTIC IN ACCORDANCE WITH IBC/FBC GLAZING IS GE LEXAN SLX2432T, AN APPROVED CC2 PLASTIC IN ACCORDANCE WITH 2606_ IBC/FBC 2606 AND AN APPROVED Cl PLASTIC IN ACCORDANCE WITH FBC 2612. THE ENTIRE DOOR ASSEMBLY INSTALLED IN COMPLIANCE WITH THIS SECTION MEETS THE THE,ENTIRE DOOR ASSEMBLY INSTALLED IN COMPLIANCE WITH THIS SECTION MEETS THE WIND LOAD REQUIREMENTS OF THE FLORIDA BUILDING CODE OR INTERNATIONAL BUILDING WIND LOAD REQUIREMENTS OF THE FLORIDA BUILDING.CODE AND INTERNATIONAL BUILDING CODE BUT.DOES NOT MEET THE IMPACT RESISTANT REQUIREMENT FOR WINDBORNE DEBRIS CODE AND IS LARGE- AND SMALL-MISSILE IMPACT RESISTANL REGIONS (REF. CHAPTER 16 FBC/IBC). _ SECTION B—B (IMPACT—RESISTANT GLAZING OPTION SECTION B—B (NON—IMPACT RESISTANT GLAZING OPTION) C DETAIL'D' C` FRONT FRAME WITH U.V. COATING ON OUTSIDE SURFACE. NOTE THAT FRONT FRAME IS NARROWER THAN Al IMPACT-RESISTANT FRAME. IB OPTIONAL DECORATIVE 225 MULTIPURPOSE HIGH BOND TAPE SNAP-IN INSERT. (BETWEEN FRAME AND FACADE). DECORATIVE FRONT FACADE. i GLAZING }� MOLDED INSIDE afee- LITE RETAINER. STRUCTURAL SILICONE'SEALANT (BSCREW ERVEEN STEEL SKIN AND FRAME). ('10 SCR PAN HEAD E). (10 SCREWS PER LITE). IUPACT RESISTANT ONE-PIECE INJECTION POLYSTYRENE RETAINER FASTENED TO FRAME VATH B MOLDED GE_LEXAN (10)p8 x 3/4"PAN HEAD MACHINE SCREWS. SLX2432T'FRONT' U FRAME&GLAZING. IMPACT—RESISTANT ASSEMBLY 'DETAILS STANDARD ASSEMBLY DETAILS DRAWING 101348-A DRAWING 10.1.348-B HAM/C�!���� E *,J• No 63/ MANUFACTURING••,.*' SHORT PRODUCT DE PANEL: PAN2FI53 � I �•'' LONG PANEL: PAN-2F156 DESIGN LOADS: +38.0 P.S.F. & -44.0 P.S.F. pAlti NO.: N/A D :,it TEST LOADS: +57.0 P:S.F. & -66.0 P.S.F. A STA E F �� UMen Stotea Olherw a 8565 Duke BoWevoE VINDLOAD RATING 0 A Rosan,OH 45040:USA TOLERANCES are c'Clapay 1 No.513-770-4809 ` / T� .0 = f.031 Cul*q F lots C.Wmy Fm 14.513-770-4a53 W 6 D R3'8 00= f.015 DESCRIPTION: CLASSIC AND CH RP STEEL PAN SC +38/-44 PSF n La ODD- m.005 DESIGN ENGINEER: - De0000-'f.001 DRAWN BY: MW DATE: 3/15/95 SCALE: NTS DW'G:D SCOTT MAILTON, P.E. 9 CHECKED BY: --- DATE: -- - SHEET 2 OF a. SIZE UNess Stolee 0", ,se FLORIDA LICENSE No. 6328 DIMENSIONS ARE IN MCHES.DWG, NO.: 101348 — A/B VER: IBC 4 3 2 FLOO BODDQ P ODD MCAT APPROOMQL 1.6107 { 4 3 2 1 f 'CLASSIC'RAISED PANEL EMBOSS DOORS 'CARRIAGE HOUSE'RAISED PANEL EMBOSS DOORS SNEER REVISIONS MODELS 24 GA 25 GA 25 Ga MODELS 25 GA 25 GA 3 OF 4 REV. N0. ZONE:I DATE: ECN NO. APPVD: .DESCRIPTION i CLOPAY 64A,94 73, 75 76 CLO GDSS,'GRSS PAY -- - - - - IDEAL 4RST, 4Fr 6RST 2RST 'GALLERY' 17 SEE REVISION HISTORY ON�SHEET ONE. { HOLIES 48, 48B 42,42B -- HOLMES ARSS -- SHORT PANEL LUNG PANEL 'ARTISTRY' -- IDEAL EDSS L-- 3" TALL U-BAR D t -MODEL 4F IS FLUSH 'CARRIAGE HOUSE' I 2"THICK 20 GA..GALV. STEEL 1 SHORT PANEL LONG PANEL I MIN, YEILD STRENGTH:.50 KSI p VERTICAL JAMB ATTACHMENT (WOOD FRAME BUILDINGS): 3/8"x3" LAG SCREWS.ON 24" CENTERS. 1-1/8" O.D. WASHER REQUIRED. LAG SCREWS MAY BE COUNTERSUNK (BUT NOT REQUIRED) TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO NOT TRANSFER LOAD. 12 GA GALV. STEEL TOP VERTICAL JAMB ATTACHMENT (C-90'BLOCK OR 2,000 PSI MIN CONCRFTF C01 UMN): ,ROLLER BRACKET. EACH 3/&x3" SLEEVE ANCHOR BOLTS ON 22" CENTERS.(2-,000 PSI MIN. CONCRETE). WASHERS BRACKET ATTACHED W/(4) INCLUDED WITH SLEEVE ANCHORS. f/ISxS/B" SHEET METAL OR SCREWS. 1/4"x3" TAPCON SCREWS ON 19" CENTERS (2,000 PSI MIN. CONCRETE) OR 10"CENTERS 25 GA. MIN. G-40 GALV. SHIP LAP JOINTS. (C-90 BLOCK). 1" O.D.WASHERS REQUIRED WITH TAPCONS. STEEL SKIN WITH A ANCHORS�MAY BE COUNTERSUNK (BUT NOT REQUIRED) TO PROVIDE A FLUSH MOUNTING BAKED-ON PRIMER AND C SURFACE: HORIZONTAL JAMBS DO NOT TRANSFER LOAD. A BAKED=QN POLYESTERTOP COAT APPLIED TO 14 GA, GALV. STEEL END HINGE OTHER JAMB CONFIGURATIONS: REFER TO DASMA TDS-161. A LICENSED DESIGN BOTH SIDES OF STEEL FASTENED TO END STILES VJ/(4) EACH CONFIGURATIONS. PROFESSIONAL MAY ALSO BE EMPLOYED TO APPROVE ALTERNATE FASTENERS AND/OR JAMB SKIN. #14x5/8" SHEET METAL SCREWS & (4) CONFIGURATIURATIONS. 1/4" SELF TAPPING SCREWS. O PREPARATION OF JAMBS BY OTHERS NOTE THE DESIGN OF THE SUPPORTING STRUCTURAL ELEMENTS SHALL BE THE RESPONSIBILITY OF THE PROFESSIONAL'OF RECORD'FOR THE BUILDING OR STRUCTURE AND �� 3" TALL x 20 GA. GALV. STEEL U-BARS IN ACCORDANCE WITH CURRENT BUILDING CODES FOR THE LOADS LISTED ON THIS DRAWING. IN A 2-1-2-1 PATTERN (I.E. TWO U-BARS ON BOTTOM SECTION, ONE 'U-BAR ON NEXT SECTION, ETC.). EACH U-BAR ATTACHED WITH (2) 1/4"x3/4" SELF TAPPING SCREWS PER STILE .LOCATION. B g 1.3 GA. GALV. STEEL BOTTOM BRACKET. ATTACHED WITH (2).#14x5/8" SHEET METAL SCREWS ALUMINUM EXTRUSION &VINYL WEATHERSTRIP. O�1 HAA4/4"" SECTION A—A (SIDE VIEW) Oj .�\GEN41 /// N fE;0!'F" / *.' MANUFACTURING PRODUCT CODE SHORT PANEL: PAN-2F153 LONG PANEL- PAN-2F156 G=w DESIGN LOADS +38.0 P.S.F. & -44.0 P.S.F. TEST LOADS +570 P.S.F & -66.0 P.S.F. PART NO.: N/A0* STtoUnless Steled Otn � 65a5 Duke Boutevdrd VINDLOAD RATING T.� Clopay "vi.OR•45040-770-➢M, '¢F` 4 0 R) P'�� TOLERANCES ore TeL.Nn.513-770 4800 W 6 D P 3 8 .O = f.031 Be�dng PeadueU C4mI'my Fox Ro.513-770-4853 o00 _01� DESCRIPTION: CLASSIC AND CH RP STEEL PAN SC +38/-44 PSF .0000 = 3.001 DRAWN BY: MW DATE: 3/15/95 SCALE: NTS DWG. DESIGN ENGINEER' Degrees =_x 1/2' CHECKED BY: -- DATE: -- SHEET 3 OF 4 ISIZIt B SCOTT HAMILTON, P.E. U.1—Stoled Otnerwts< FLORIDA LICENSE No. 63286 DIMENSIONS ARE M INCHES:DWG. NO.: 101348 - A/B VER: IBC 4 3 2 FLOIRPO PFRIODUCT APPROWAL 16107 i t 4 3 2 1 'CLASSIC'RAISED PANEL EMBOSS DOORS 'CARRIAGE HOUSE'RAISED PANEL EMBOSS DOORS SHEET, REVISIONS MODELS 1 24 GA 1 25 GA 25 GA MODELS 25 GA zs Ga 4 OF 4 REV. NO. ZONE: DATE: ECN.NO. APPVD: DESCRIPTION CLDPAY 84a, 94 73, 75 76 LT_OPaY GI)SS,GRSS 17 - - - - SEE REVISION.HISTORY ON SHEET ONE. IDEAL 4RST:4FM 6RST 2RST 'GALLERY' HOLMES 1 48, 48B 142. 428 HOLMES AR55 ( SHORT PANEL LONG PANEL 'ARTISTRY' -- • -D MODEL 4F IS FLUSH 'CARRI AGE IDEAL HOUSE' E115S -- . SHORT PANEL I LONG PANEL D 2"TRACK CONFIGURATION. FDTG TERBALANCE.SYSTEMJAMB CONFIGURATION. HORIZONTAL TRACK V.STEEL FLAC BRACKET ATTACHED-TO DOOR - SUPPORT BY DOOR (3)5/16"-X 1-5/8"LAG SCREWS HEIGHT "L" INSTALLER(TO SUIT). ACK WITH(2) 1/4"RIVETS. 6'-67 "T-0". 7 2a6 SYP WOOD JAMB, SEE OPTIONAL STOP MOULDING.BY INSTALLER TO,SUIT, !DM TRACK CONFIGURATION ( )T-6" _ "JAMB'PREPARA770N NOTE".'ABOVETHE DHE.WINEN OA DOES ING NTE 30"O:C. 8.-0_ 16 GA GALV.STEEL END STILE. N07 AFFECT THE.OOR.LOADRATING OF THIS DOOR. 0 8'-fi" 4" � J- 0 GALV. STEEL TRACK, 1CK THICKNESS: 0.683`. B,-6"1 2-V2"% 12 GA GALv,STEEL- u 10'-0" 1 TRACK BRACKETS FASTENED TO 10-6"1 8" WOOD JAMBS WITH 5/6"X 1-9/8' _ 7/16"I.D. ROUND 18 GA.GALV. SIEEL�CENTER HINGE g _L_ 11'-0" LAG SCREWS, PUSH NUT FASTENED TO INTER.STILES W/(4)EACH 1 FASTENER: 's 36"+2` g14x5/8'SHEET METAL SCREWS. C TIP. 2-1/2"X 12 GA GALV. 12'-0"13 " z STEEL TRACK BRACKETS; --6'14 " 14 GA GALV.STEEL ROLLER.HINGES FASTENED 70 END STILES W/(4)EACH y114x5/8" C W ATTACHED TO JAMS!V1I7H (t) 13'-O`14 " SHEET METAL SCREWS AND(2) 1/4"SELF TAPPING SCREWS PER END HINGE. a 5/16"x 7-5/8"LAG SCREW PER 1 4" 2"GALV.STEEL TRACK FASTENED TO TRACK BRACKET. 4'-0` 12 GA GALV STEEL TRACK BRACKETS 1 WITH EITHER(2) 1/4"DIA.RIVETS OR 2"DA.7-1/2"LONG STEM. 10 BALL STEEL ROLLER WITH STEEL OR NYLON TIRE. 10" 16'-0" (1) 1/4'%.5/8"BOLT&NUT PER SECTION C-C -3-1/2" TRACK BRACKET. ....... 16-0`1 4" PREPARATION OF JAMBS BY OTHERS LHR BRACKET(2-1/2"x 5-3/4"x 12GA) 3"TRACK IS ALSO AVAILABLE ATTACHED WITH(2) 1/4-x 3/4"SELF TAPPING SCREWS. DOUBLE TRACK LOW HEAOR001.1 OPTION DOUBLE HORIZONTAL TRACK. B B `% O�T HAA4tt 0G 4�G E N.SF:�2�•�. No.6l �,_.�• `! * MANUFACTURING PRODUCT CODE SHORT PANEL: PAN-2F153 LONG PANEL: PAN-2F156 gg DESIGN LOADS 7.0 P .S F. & -.0 P.S.F.P.S.F. PART NO.: N/A A 9:. STA-ES !� 14/� TEST LOADS +570 P.SF & -66.0 PF. A 4 . U61ese Staled Ota 's =C�apay 8585 Duke B4Vlevmd VINDLOAD RATING o'•.R P �?�` TOLERANCES e a Mosort.OH 45040 USA ... ���% .D= 3.031 B.Wq hodxts Can,enr I.Mu.513-770-485533 `1V 6 D P 3 8 ONAit .00 = 3,015 DESCRIPTION: CLASSIC AND CH RP STEEL PAN SC +38/-44 PSF 000 = t:005 DESIGN ENGINEER: - .0000= t_001 DRAWN BY: MW DATE: 3/15/95 SCALE: NTS MG.T Degrees CHECKED BY: -- DATE: -- SHEET 4 OF 4 SIZE L SCOTT HAtAILTON, P.E. Unless Stoted Dtnerase FLORIDA LICENSE No.. 63286 DIMENSIONS ARE IN i=<S. DWG. NO.: 101348 - A/B VER: IBC . 4 3 2 IGLOO RODQ PRODUCT DD UC T APPROVAL 16107 February 14, 2013 (Revised 8/10/17) Evaluation Report for Clopay Building Products Company Sectional Garage Doors, W6 through W8 I have evaluated the wind load door designs as shown on the drawings listed below. I have reviewed the test reports, which were generated by accredited independent. laboratories as required by the relevant Florida Administrative Rule, the engineering rational analysis, and the product drawings. The test reports are listed below. Assembly testing was conducted by American Test Lab North Carolina. Component testing was conducted by HETI and ETC. For the doors listed in Tables 1 through 5, Static Pressure Tests were conducted in accordance with TAS 202-1994, ASTM-E330-2002 and ANSI/DASMA 108-2005. Missile Impact and Cyclic Pressure Tests were conducted in accordance with TAS 201-1994 and TAS 203-1994 and ASTM E1886-2005 and ASTM E1996-2009 and ANSI/DASMA 115-2005.The pressures listed on the drawings are.either direct results of these tests or results obtained through engineering rational analysis based on actual tests. I have concluded that the door designs listed below in Tables 1 through 5 are in compliance with these High Velocity Hurricane Zone test requirements of the Florida Building Code and therefore are qualified as impact-resistant assemblies (large missile impact). TABLE.1: Drawings for doors with Manufacturing Product Code (MPC) PAN-2F 53: 101348-A-Rev17, max. door size 9'0"" x 1610"; +38/-44 PSF (design load) TABLE 2: Drawings for doors with ManWWcturing Product Code (MPC) PAN-21=156: 101348-A-Rev17, max. door size 9'0"" x 16'0"; +38/-44 PSF (design load) TABLE 3: Drawings for doors with Manufacturing Product Code (MPC) DSIE-1F171: 1.01..526-A-Rev20, max. door size 910"" x 16'0"; +38/-44 PSF (design load) TABLE 4: Drawincs for �dQ.Qcgwith Manufacturing Prgdurct Code (MPC) DSIU-1F171: 104778-Rev03, max. door size 16'2" x 16'0"; +46/-52 PSF (design load) TABLE 5: Drawings for doors with Manufacturing Product Code (MPC) DSIE-1E471: 104785-A-Rev03, max. door size 16'2" x 16'0"; +38/-42 PSF (design load) 104786-Rev04, max. door size 1612" x 16'0"; +46/-52 PSF (design load) For the doors in Tables 6 through 9, Static Pressure Tests were conducted In accordance with ASTM-E330-2002 and ANSI/DASMA 108-2005. The pressures listed on the drawings are either direct results of these tests or results obtained through engineering rational analysis based on actual tests. I have concluded that the door designs listed below in Tables 6 through 9 are in compliance with these test requirements of the Florida Building Code. TABLE 6: D s_for_door_s_with_Manufactur�rtg�roduct C�(MPC) PAN-2F153: 101348-B-Rev1:7, max. door size 9'0"" lx 1x'000"; +38/-44 PSF (design load) PAGE 1 OF 3 FILE: CBPC_130214-A.3 EVALUATION REPORT FOR CLOPAY BUILDING PRODUCTS COMPANY SECTIONAL GARAGE DOORS,w6^W8 TABLE 7: Drawings for doors with Manufacturing Product Code (MPQ PAN-2F156: 101348-13-Rev17, max. door size 9'0"" x 16'0"; +38/-44 PSF (design load) TABLE 8: Drawings for doors with Manufacturing Product Code (MPC) DSIE-1F1.7Ji 101526-B-Rev20, max. door size 9'0"" x 16'0"; +38/-44 P5F (design load) TABLE s for doors with Manufac urin P MPC DSIE-1F471: 104785-B-Rev03, max. door size 16'2" x 16'0"; +38/-42 Ps'F (design load) ZeSt_Reports: ATL-0107.01-13 (2/20/13), ATL-1206.01-12 (1/23/13), ATL-0801.01-12 (8/15/12), ATL-0827.01-12 (10/9/12), ATL-0115.01-13R (3/18/13), ATL-0117.01-13R (3/18/13). These reports document compliance with the TAS testing standards and are signed and sealed by David Johnson, FL PE 61915. Product Description for doors with MPC PAN-2F153: These doors consist of 2" thick steel pan sections with min. 25 ga. (0.019") skins. The steel skin is at least G40 DDS per ASTM A653. The maximum section height is 21". These doors may have optional Impact-Resistant Glazing (Molded). Optional Impact-Resistant Glazing is a one-piece injection-molded front frame and glazing, The following models are at least structurally equivalent to the tested door: 84A, 94, 98, 73, 75, 1500, 190, 4RST, 4F, 4RSF, 6RST, 6RSF, 48, 48B, 42, 42B, 55, 55S, GD5S, GD5SV, GR5S, GRSSV, AR5S, AR5SV, EDSS, ED5SV. Not all models may be shown on a given drawing, Product Description for doors with MPC PAN-2F156: These doors consist of 2" thick steel pan sections with min. 25 ga. (0.019") skins. The steel skin is at least G40 DDS per ASTM A653. Sections may have 1-5/16" insulation captured in the cavity of the pan section. The maximum section height is 21". These doors may have optional Impact-Resistant Glazing (Molded). Optional Impact-Resistant Glazing is a one-piece injection-molded front frame and glazing. The following models are at least structurally equivalent to the tested door: 76, 76V, 2RST. Not all models may be shown on a given drawing. Product Description for doors with MPC DSIE-1F171: These doors consist of 2" double-skin Insulated sections with an EPS core laminated to both skins. Both Inner and outer skins are min. 27 ga. (0.016") G40 DDS per ASTM A653:The maximum section height is 21". These doors may have optional Impact-Resistant Glazing (Molded). Optional Impact-Resistant Glazing is a one-piece injection-molded front frame and glazing. The following models are at least structurally equivalent to the tested door; 4300, 4301, 4310, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, 6200, 6201, 6203, SP200, SF200, SE200, Not all models may be shown on a given drawing. P-r-o-i_u_ct_Description for doors with MPC DSIU-1F171 These doors consist of 2" double-skin insulated sections with polyurethane insulation foamed in place between both skins. Both inner and outer skins are min. 27 ga. (0.016") G40 DDS per ASTM A653. The maximum section height Is 21". These doors may have optional Impact-Resistant Glazing (Molded). Optional Impact-Resistant Glazing is a one-piece injection-molded front frame and glazing. The following models are at least structurally equivalent to the tested door: HDP20, HDPF20, HDPL20, 7200, PAGE 2 OF 3 FILE: CBPC 130214-A.3 EVALUATION REPORT FOR CLOPAY BUILDING PRODUCTS COMPANY SECTIONAL GARAGE DOoRs,W6—W8 7201; 72031 8200, 8201, 8203, 9200, 9201, 9203. Not all models may be shown on a given drawing. Product Description for dogr5wilb MPC D5I&1F4 _ These doors consist of 2" double-skin insulated sections with an EPS core laminated to both skins. Both inner and outer skins are min. 27 ga. (0.016") G40 DDS per ASTM A653. The maximum section height is 24". These doors may have optional F Impact-Resistant Glazing (Aluminum). Optional Impact-Resistant Glazing is an j aluminum front frame and a separate polycarbonate glazing. The following models are at least structurally equivalent to the tested door: GD2'SP, GR2SP, GD2LP, GR2LP, AR2SP, AR2LP, ED2SP, ED2LP, 4302, HDGC, 6202, MFC68, 4305; HDGR, MFR68, 6205, SFR68, Not all models may be-shown on a given drawing. xmpa_ct_Resistant Glazing (Molded) The optional impact resistant glazing is an injection-molded polycarbonate front frame and glazing (GE LEXAN SLX2432T) that is an approved C1 plastic in accordance with testing required by FBC-B 2612. Approval based on review of the following tests: HETI-06-AO02 ASTM G155'; HETI-06-T566 ASTM D638 (before); HETI-06-T634 ASTM D638 (after); ETC-06-1024-17496.0 ASTM D2843, ASTM D635, ASTM D1929, Impact Resistant Glazing (Aluminum)- The optional impact resistant glazing is an aluminum front frame and a separate polycarbonate glazing that is an approved C1 plastic in accordance with testing required by FBC-B 2612. Approved polycarbonate materials are Sabic IP Lexan 9034 (Versions also approved: MR10, 9030, 90318, 90316, 90317, 90311, 90314, 90355) and Bayer Makrolon GP (versions also approved: SL, AR, 15). Approval based on review of NOA 13-0717.01 (Sabic IP, exp. 7/17/18) and NOA 12-0605.05 (Bayer, exp. 8/27/17). Limitations: The drawing(s) cited above are an explicit part of this evaluation report. The text of this report does not attempt to address all design details and relies on the illustrations and text of these drawings as well. Jambs, lintels, sills or other structural elements required to prepare openings are not covered. The design of the supporting structural elements shall be the responsibility of the professional of record for the building or structure and in accordance with current building codes for the loads listed on the drawings) referenced above. Installation requirements per the relevant Florida Administrative Rule, including attachments, are detailed on the drawing(s) listed above. Installation must be in accordance with manufacturer's installation instructions and must be as shown on the drawing(s) listed above. The manufacturer's licensed design professional listed on the drawing(s) has reviewed the'attachment details and installation requirements. Signature: lHAj'�r�i / Cb Scott Hamilton, P. E. No 6 28 Florida P. E. No. 63286 Date: aPilaI"Q ��•;, STATE OF + PAGE 3 of 3 N �� FILE: CBPC_130214-A.3 A�%J%8%