LEGEND
A/C - AIR CONDITIONER FND. - FOUND i
`CONC. —'CONCRETE COV'D — COVERED
ESS 4
I P - IRON PIPE I.D. — IDENTIFICATION
IM =-•IRON-BAR E.O.P. ECGE OF PAVEMENT j
OF O.H.W. - OVERHEAD WIRE LB — LICENSED BUSINESS /+ I
R/W — RIGHT-OF—WAY N. & W. - NAIL & WASHER UC
( C M CONCRETE MONUMENT P.B. - PLAT BOOK PG. - PAGE
N . NORTH ,'E - EAST W - WEST S - SOUTH i
IE N.A.V:D. 88 = NORTH AMERICAN VERTICAL DATUM'1988 SYMBOLS , j
I N G V,D. 29 — NATIONAL GEODETIC VERTICAL DATUM 1929 a !
SET I:B: — SET 5/8'-IRON BAR CAP #4459 p — CABLE TV BOX EARLE R
BY (P) .•DENOTES DISTANCE, ANGLE OR BEARING BY FURNISHED 3
ID 'DESCRIPTION 4 ® — WATER METER REGIS "
(F) —'DENOTES MEASURED-DISTANCE-, ANGLE OR-BEARING t — CENTERLINE SURVEY NOS,
(C> — DENOTES CALCULATED DISTANCE, ANGLE OR BEARING RAISED SEAL OFF..
SLAB - THICKENED EDGE FOOTING SIZES
General Notes:
1. 6"x6" 10/10 WWM or Fibermesh added concrete
2. 6 MIL Visqueen vapor barrier required on termite treated soil when next to
living space or under habitable space.
3. Compaction test required when fill exceeds 18", 95% minimum compaction
required.
SLAB/FOOTING USED
4"THICK SLAB MIN 4"THICK SLAB MIN
18"
45 DEGREES 8" 45 DEGREES
811
2-#5 REBARS •
12"
4"THICK SLAB MIN I 4"THICK SLAB MIN
8"
45 DEGREES • 4" NON STRUCTURAL
1-#5 REBAR 8" (NO FUTURE BUILDING)
Slab/Footing updated 12/16/14 tjv