Loading...
HomeMy WebLinkAboutEngineering Architectonic Inc St. Lucie County Planning& Development Services Building&Code Regulation Division 2300.Virginia Ave. Fort Pierce, FL 34982 January 28, 2020 RE: 3810 Selvitz Road,St.Lucie County Garage Door Replacement To Whom It May Concern: Our office has performed design pressure calculations for the above referenced project and herby certify that the proposed garage doors are in compliance with the 2017 Florida Building Code, 160 mph wind zone,exposure"C",risk category II. From Table 1609.3.1: Vint= 160mph Va,d= 124mph From Table 1609.7(1) 12'w x 20' h, 160 mph=+23.81/-26.4 From Table 1609.7(2): 24' mean roof height,exposure C=1.21 Required Design Pressures: 23.81 x 1.21=28.8 -26.4x1.21 =31.9 Product:Janus International Corp 26 ga.Series 3100 Door Assembly FL#12765.3 Product Pressures: +36.0&-41.0 e ert ,,l Nuli 5. •,'Qs® OkCH EL JS 1.7 File COPY m a 9689,9 ED FOR 1Chael eal,AIA 'G- REVIEWED A s,89�8 ......• �� CODE COMPLIANCE ST. LUCIE Co N�� BOCCW 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg#AA26003348 1 of 1