HomeMy WebLinkAboutEngineering Architectonic Inc
St. Lucie County
Planning& Development Services
Building&Code Regulation Division
2300.Virginia Ave.
Fort Pierce, FL 34982
January 28, 2020
RE: 3810 Selvitz Road,St.Lucie County
Garage Door Replacement
To Whom It May Concern:
Our office has performed design pressure calculations for the above referenced project and herby certify
that the proposed garage doors are in compliance with the 2017 Florida Building Code, 160 mph wind
zone,exposure"C",risk category II.
From Table 1609.3.1: Vint= 160mph
Va,d= 124mph
From Table 1609.7(1) 12'w x 20' h, 160 mph=+23.81/-26.4
From Table 1609.7(2): 24' mean roof height,exposure C=1.21
Required Design Pressures: 23.81 x 1.21=28.8
-26.4x1.21 =31.9
Product:Janus International Corp 26 ga.Series 3100 Door Assembly FL#12765.3
Product Pressures: +36.0&-41.0
e ert ,,l Nuli
5. •,'Qs®
OkCH EL JS 1.7 File COPY
m a 9689,9 ED FOR
1Chael eal,AIA 'G- REVIEWED
A s,89�8 ......• �� CODE COMPLIANCE
ST. LUCIE Co N��
BOCCW
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com
Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg#AA26003348 1 of 1